Back to Authors

Jadlowiec, Caroline C.

https://orcid.org/0000-0001-7860-9519

Mayo Clinic

Divsion of Transplant Surgery

Citations 74

Advances in Kidney Transplant, Machine Perfusion, and Viability Markers
Ohara, Stephanie , Chávez‐Villa, Mariana , Mao, Shennen A. , Clendenon, Jacob , Heimbach, Julie, Ryan, Randi , Kodali, Lavanya, Nguyen, Michelle C., Nateras-Nunez, Rafael, Jadlowiec, Caroline C. , Jadlowiec, Caroline , Mao, Shennen A , Ohara, Stephanie Y , Ryan, Randi J. , Clendenon, Jacob N. , Chavez-Villa, Mariana , Heimbach, Julie, Kodali, Lavanya, Nguyen, Michelle C., Nateras-Nunez, Rafael

Kidney and Dialysis | August 14, 2025 | Volume: 5 | Issue: 3 | Pages: 37

10.3390/kidneydial5030037 Get It

Despite improvements in kidney transplantation rates, the shortage of donor kidneys remains a critical issue, exacerbated by non-utilization of recovered kidneys due to quality concerns, necessitating advancements in perfusion methods to enhance graft outcomes and usage. Although static cold storage remains the default standard for kidney preservation, newer methods like hypothermic machine perfusion have shown improved outcomes, including reduced delayed graft function and better survival rates. Hypothermic oxygenated machine perfusion and normothermic machine perfusion offer some potential clinical benefits but studies to date have demonstrated mixed results. In the United States, LifePort and the XVIVO’s Kidney Assist Transport are the most popular hypothermic perfusion devices, with NMP devices mostly in trials. Combining perfusion with biomarkers such as mitochondrial flavin mononucleotide, neutrophil gelatinase-associated lipocalin, and osteopontin shows promise in assessing kidney viability and predicting post-transplant outcomes, though further research is also needed. Emphasis on repair biomarkers, such as uromodulin and osteopontin, aims to better predict graft outcomes and develop new therapies. While notable advancements have been made in the use of machine perfusion and viability testing for liver transplantation, additional research with larger sample sizes is essential to substantiate these results and enhance kidney transplantation outcomes.
Survey of Early Practices and Perceptions of Liver Machine Perfusion Among US Liver Transplant Surgeons
Nguyen, Michelle , Li, Xingjie , Ohara, Stephanie, Motamed, Mehrdad, Moss, Adyr A. , Reddy, Kunam S. , Mathur, Amit K. , Nguyen, Michelle C , Zhang, Chi , Motamed, Mehrdad, Jadlowiec, Caroline C.

Transplantation Direct | June 27, 2025 | Volume: 11 | Issue: 7 | Pages: e1841

10.1097/txd.0000000000001841 Get It

Background. Ex vivo machine perfusion (MP) has transformed organ preservation, offering significant benefits in liver transplantation (LT), particularly with high-risk donor grafts. However, adoption in the United States has been limited. We aimed to examine early adoption trends, surgeon perceptions, and barriers to implementing MP in the United States after Food and Drug Administration approval of MP platforms. Methods. A 23-question electronic survey was distributed to members of the American Society of Transplant Surgeons between October and November 2022, capturing attitudes and practices related to MP adoption. Responses from 96 surgeons representing 77 LT centers across 11 Organ Procurement and Transplantation Network regions were analyzed. Results. Forty-four respondents (48%) reported having an MP program at their institution. Adoption of MP was significantly more common in high-volume centers and those performing ≥20 donation after circulatory death (DCD) transplants annually (P < 0.001). MP utilization received strong support, with 88% endorsing its use for DCD liver allografts and 82% for donation after brain death allografts. Respondents cited MP’s ability to reduce ischemic cholangiopathy, enable graft repair, and facilitate viability assessment as key benefits. Normothermic MP was preferred for high-risk donor profiles, including DCD grafts, older donors, and steatotic livers, and was associated with an increased willingness to accept medically complex grafts compared with static cold storage. Barriers to MP utilization included program costs, personnel demands, and logistical complexities. Centers with higher proportions of privately insured patients were more likely to adopt MP. Despite these challenges, 84% of respondents expressed interest in future MP adoption. Conclusions. MP enhances graft utilization and outcomes, particularly for complex and high-risk donor livers, but widespread US adoption requires addressing financial and logistical barriers. Future efforts should focus on refining cost-effectiveness analyses, collaboration with organ procurement organizations and device companies, and developing standardized training to optimize MP integration and maximize its clinical impact on LT.
Health insurance and kidney transplantation outcomes in the United States: a systematic review and AI-driven analysis of disparities in access and survival
Valencia, Oscar A. Garcia , Wathanavasin, Wannasit , Leeaphorn, Napat , Soliman, Karim , Budhiraja, Pooja , Miao, Jing , Cheungpasitporn, Wisit , Garcia Valencia, Oscar A, Siranart, Noppachai , Soliman, Karim M , Cheungpasitporn, Wisit , Garcia-Valencia, Oscar , Miao, Jing , Budhiraja, Pooja , Wathanavasin, Wannasit , Suppadungsuk, Supawadee , Thongprayoon, Charat , Ho, Yuh‐Shan , Jadlowiec, Caroline C. , Mao, Shennen A. , Ali, Hatem Kaies Ibrahim Elsayed

Renal Failure | June 10, 2025 | Volume: 47 | Issue: 1 | Pages: No page available

10.1080/0886022x.2025.2513007 Get It

Normothermic Machine Perfusion Improves Outcomes for Donation After Cardiac Death Allografts With Extended Donor Warm Ischemia Time
Li, Xingjie , Ohara, Stephanie , Reddy, Kunam S. , Mathur, Amit K. , Nguyen, Michelle , Ohara, Stephanie Y , Jadlowiec, Caroline , Mathur, Amit , Nguyen, Michelle C , Chang, Yu‐Hui , Jadlowiec, Caroline C.

Clinical Transplantation | March 16, 2025 | Volume: 39 | Issue: 3 | Pages: No page available

10.1111/ctr.70133 Get It

ABSTRACT Introduction Donation after circulatory death (DCD) allografts are underutilized in liver transplantation (LT) due to increased risk of complications. These risks stem from ischemic injury sustained during the total donor warm ischemia time (tDWIT), historically limited to 30 min. Normothermic machine perfusion (NMP) can mitigate these risks and facilitate LT of DCD grafts with extended tDWIT. We aimed to compare outcomes of DCD allografts with extended tDWIT preserved on NMP versus static cold storage (SCS). Methods This single‐center study included adult DCD LT with tDWIT ≥ 30 from 2019 to 2023. Outcomes of NMP and SCS were compared including EAD, IC, graft survival, and patient survival. Results Among 68 DCD LT with tDWIT ≥ 30, 64.7% ( n = 44) were preserved with NMP and 35.3% ( n = 24) with SCS. No differences in donor or recipient demographics were observed. The median tDWIT was 33 min for NMP and 30.5 min for SCS ( p < 0.01). Despite longer tDWIT, the NMP group had lower rates of EAD (4.5% vs. 66.7%, p < 0.01) and IC (2.3% vs. 29.2%, p < 0.01). One‐year graft survival was higher in NMP ( p < 0.01), and 1‐year patient survival was comparable between groups ( p = 0.18). Conclusion NMP challenges traditional tDWIT constraints and can increase the pool of viable DCD allografts for transplantation.
Incisional Hernia Risk Reduction for Living Kidney Donors: Kidney Extraction Site Matters
Punukollu, Rachana , Ohara, Stephanie , Alexandru, Nica, Cosentino, Christopher P., Frasco, Peter E. , Andrews, Paul E. , Nica, Alexandru , Briggs, Logan G , Cosentino, Christopher, Frasco, Peter, Andrews, Paul , Mao, Shennen, Punukollu, Rachana , Arias, Sandra, Briggs, Logan , Nguyen, Michelle , Mao, Shennen A. , Heimbach, Julie K. , Jadlowiec, Caroline C.

Journal of the American College of Surgeons | February 13, 2025 | Volume: 241 | Issue: 2 | Pages: 195-202

10.1097/xcs.0000000000001356 Get It

BACKGROUND: Although most transplant centers preferentially offer minimally invasive approaches to donor nephrectomies, there remains less standardization specific to the kidney extraction site. This study aimed to evaluate incisional hernia occurrence in living kidney donors based on kidney extraction site location. STUDY DESIGN: This was a retrospective study of all donors who underwent minimally invasive living donor nephrectomies at the Mayo Clinic Arizona between 2011 and 2023 with a 2-year external validation cohort from Mayo Clinic Florida and Mayo Clinic Minnesota. The cohort was divided into 2 groups based on the kidney extraction site type: midline infraumbilical and Pfannenstiel. RESULTS: In the primary cohort, incisional hernia occurrence was observed in 1.2% of donors with an infraumbilical midline kidney extraction site compared with 0.1% with a Pfannenstiel extraction site (p = 0.04). Donors with an infraumbilical midline kidney extraction site were more likely to be men (50.8% vs 23.3%, p < 0.0001), have a higher BMI (mean 27.2 vs 26 kg/m2, p < 0.0001), and have current or former tobacco use (p = 0.002). There were no differences in incisional hernia occurrence when comparing minimally invasive surgical techniques (p = 0.52). In the external validation cohort, hernia occurrence was observed in 4.5% of donors with a midline incision compared with 0.0% with a Pfannenstiel incision (p = 0.09). Using combined data from the 3 sites, the use of a Pfannenstiel incision as the extraction site was associated with significantly lower odds of developing a hernia compared with the infraumbilical midline incision (odds ratio 0.06, 95% CI 0.008 to 0.456). CONCLUSIONS: Although the risk of hernia in living kidney donors is generally low, the use of a Pfannenstiel incision for kidney extraction appears to offer an additional incremental reduction in risk.
Improved Outcomes and Resource Use With Normothermic Machine Perfusion in Liver Transplantation
Zhang, Chi , Li, Xingjie , Ohara, Stephanie , Kumm, Kayla , Cosentino, Christopher P., Aqel, Bashar , Frasco, Peter E. , Nunez-Nateras, Raphael, Hewitt, Winston R. , Harbell, Jack W. , Singer, Andrew L., Moss, Adyr A. , Reddy, Kunam S. , Mathur, Amit K. , Kumm, Kayla R, Lizaola-Mayo, Blanca C, Nguyen, Michelle , Chang, Yu‐Hui , Aqel, Bashar A. , Lizaola‐Mayo, Blanca , Nunez-Nateras, Raphael, Katariya, Nitin , Jadlowiec, Caroline C.

JAMA Surgery | January 29, 2025 | Volume: 160 | Issue: 3 | Pages: 322

10.1001/jamasurg.2024.6520 Get It

Importance Normothermic machine perfusion (NMP) has been shown to reduce peritransplant complications. Despite increasing NMP use in liver transplant (LT), there is a scarcity of real-world clinical experience data. Objective To compare LT outcomes between donation after brain death (DBD) and donation after circulatory death (DCD) allografts preserved with NMP or static cold storage (SCS). Design, Setting, and Participants This single-center, retrospective observational cohort study included all consecutive adult LTs performed between January 2019 and December 2023 at the Mayo Clinic in Arizona. Data analysis was performed between February 2024 and June 2024. Outcomes of DBD-SCS, DBD-NMP, DCD-SCS, and DCD-NMP transplants were compared. Exposure DBD and DCD livers preserved on NMP or SCS. Main Outcomes and Measures The primary outcomes were early allograft dysfunction (EAD), intraoperative transfusion, and post-LT hospital resource use, including length of stay (LOS) and readmissions. Secondary outcomes included acute kidney injury (AKI) and 1-year graft and patient survival. Results A total of 1086 LTs were included in the following 4 groups: DBD-SCS (n = 480), DBD-NMP (n = 63), DCD-SCS (n = 264), and DCD-NMP (n = 279). Among LT recipients, median (IQR) age was 60.0 years (52.0-66.0); 399 LT recipients (36.7%) were female. DCD-NMP had the lowest EAD rate (17.5%), followed by DCD-SCS (50.0%), DBD-NMP (36.8%), and DBD-SCS (27.3%) ( P &amp;lt; .001). DCD-NMP had the lowest intraoperative transfusion requirement compared to all other groups. Hospital and intensive care unit (ICU) LOS were shortest in DCD-NMP (median [IQR] hospital LOS, 5.0 days [4.0-7.0]; P = .01; median [IQR] ICU LOS, 1.5 days [1.2-3.1]; P = .01). One-year cumulative readmission probability was 86% lower for DCD-NMP vs DCD-SCS (95% CI, 0.09-0.22; P &amp;lt; .001) and 53% lower for DBD-NMP vs DBD-SCS (95% CI, 0.26-0.87; P &amp;lt; .001). AKI events were lower in DCD-NMP (31.1%) vs DCD-SCS (47.4%) ( P = .001). Compared to SCS, the NMP group had a 78% overall reduction in graft failure (hazard ratio [HR], 0.22; 95% CI, 0.10-0.49; P &amp;lt; .001). For those receiving DCD allografts, the risk reduction was even more pronounced, with an 87% decrease in graft failure (HR, 0.13; 95% CI, 0.05-0.33; P &amp;lt; .001). NMP was significantly protective from patient mortality vs SCS (HR, 0.31; 95% CI, 0.12-0.80; P = .02). Conclusions and Relevance In this observational high-volume cohort study, NMP significantly improved LT clinical outcomes and reduced hospital resource use, especially in DCD allografts. NMP may enhance access to LT by addressing the challenges historically linked with DCD liver use.
Severe Non–Donor-Derived Lymphocytic Choriomeningitis Virus Infection in 2 Solid Organ Transplant Recipients
Sayyad, Leanna , Smith, K. L. , Sadigh, Katrin S. , Cossaboom, Caitlin M. , Choi, Mary J. , Whitmer, Shannon , Cannon, Debi , Krapiunaya, Inna , Morales-Betoulle, Maria , Annambhotla, Pallavi , Basavaraju, Sridhar V. , Ruberto, Irene, Kretschmer, Melissa , Gutiérrez, Nubia Silva, Zabel, Karen, Austin, Connie, Sandoval, Edith, Servellita, Venice , Foresythe, Abiodun, Sumimoto, Nanami, Aqel, Bashar , Khamash, Hasan , Jaramillo, Andrés , Grill, Marie , Montgomery, Joel M. , Shoemaker, Trevor , Vikram, Holenarasipur R. , Sayyad, Leanna E , Smith, Kami L , Khamash, Hassan , Jadlowiec, Caroline , Grys, Thomas E , Jaramillo, Andres , Grill, Marie F , Montgomery, Joel M , Shoemaker, Trevor , Klena, John D , Chiu, Charles , Vikram, Holenarasipur R. , Gutierrez, Nalleli, Sandoval, Edith, Aqel, Bashar A. , Jadlowiec, Caroline C. , Grys, Thomas E. , Chiu, Charles Y.

Open Forum Infectious Diseases | January 3, 2025 | Volume: 12 | Issue: 2 | Pages: No page available

10.1093/ofid/ofaf002 Get It

Abstract Background Lymphocytic choriomeningitis virus (LCMV) infection in immunocompromised hosts can result in disseminated disease, meningoencephalitis, and death. Published cases in transplant recipients have been traced to transmission from infected donors. We report 2 cases of serious, non–donor-derived LCMV infection in solid organ transplant recipients. Methods Initial identification of LCMV infection was done by using metagenomic next-generation sequencing (mNGS). Subsequent evaluations and confirmatory testing involved molecular diagnostics, serology, and phylogenetic analysis. A detailed epidemiologic investigation was conducted. Results LCMV was detected by mNGS in 2 solid organ transplant recipients from distinct donors. A heart transplant recipient (from donor 1) died of progressive, disseminated LCMV infection, while a kidney transplant recipient (from donor 2) with LCMV meningoencephalitis survived. A multistate laboratory and epidemiologic investigation of both donors and all their organ recipients was initiated. Postmortem samples were obtained from both donors, and pretransplant and/or posttransplant samples were obtained from 5 of the 6 organ recipients. mNGS, serologic, and real-time reverse-transcription polymerase chain reaction testing confirmed LCMV infection in both solid organ transplant recipients. Epidemiologic investigation revealed significant pretransplant rodent exposures for both LCMV-infected recipients. Laboratory studies for the other organ recipients from both donors were negative for LCMV infection. Conclusions Our investigations suggest that LCMV infection in 2 solid organ transplant recipients originated from rodent exposure preceding transplantation and were not donor derived. Although uncommon, healthcare providers should be aware of LCMV-associated serious and life-threatening illness in immunocompromised hosts. Diagnostic modalities are limited to reference laboratories.
Do Factors Influencing Acceptance of Kidney Stone Formers as Donors Predict Subsequent Stone Events?
Keddis, Mira T. , Howard, Matthew R., Zhang, Nan , Quillen, Jaxon , D’Costa, Matthew R. , Khamash, Hasan , Porter, Ivan E. , Stern, Karen , Quillen, Jaxon K, Khamash, Hasan A, Jadlowiec, Caroline , Wadei, Hani M , Porter, Ivan , D'Costa, Matthew , Stern, Karen L , Jadlowiec, Caroline C. , Wadei, Hani M. , Rule, Andrew D.

Clinical Transplantation | December 31, 2024 | Volume: 39 | Issue: 1 | Pages: No page available

10.1111/ctr.70069 Get It

ABSTRACTPurposeThis study aimed to assess whether kidney stone burden and risk factors at the time of kidney donor evaluation were associated with a symptomatic stone event post‐donor evaluation.MethodsWe identified adults evaluated at Mayo Clinic (two sites) (2000–2011) for living kidney donation and had either a personal history or radiological evidence of kidney stone disease. We analyzed demographics, stone risk factors, stone number/size, and the committee's donation decision and reasons. A follow‐up survey (2022–2023) assessed post‐evaluation symptomatic kidney stones and related morbidity.ResultsAmong 412 potential donors with kidney stone disease, 258 donated, 75 did not donate due to kidney stones, and 79 did not donate for other reasons. Multivariable analysis showed that candidates not donating due to stones had higher body mass index (BMI), prior symptomatic kidney stones, multiple stones on imaging, bilateral kidney stones, and diameter of largest stone ≥3 mm. Of 147 who completed the survey, 26 (18%) had a symptomatic kidney stone post‐donor evaluation. Younger age (p = 0.031) and multiple stones on imaging (p = 0.02) were significant predictors of post‐evaluation symptomatic stones regardless of donation status (p = 0.41).ConclusionsStone burden on imaging and prior symptomatic stone events were associated with not donating. Younger age and stone burden on imaging were the primary risk factors for a symptomatic kidney stone event after donor evaluation.
Examining Insurance-Related Disparities in Kidney Transplantation Access and Outcomes: A Systematic Review and Bibliometric Analysis
Leeaphorn, Napat , Budhiraja, Pooja , Budhiraja, Pooja , Valencia, Oscar A. Garcia , Suppadungsuk, Supawadee , Thongprayoon, Charat , Jadlowiec, Caroline C. , Cheungpasitporn, Wisit

Journal of the American Society of Nephrology | October 28, 2024 | Volume: 35 | Issue: 10S | Pages: No page available

10.1681/asn.20247ck1zcjq Get It

Preservation of coagulation function by normothermic machine perfusion in liver transplant as evidenced by thromboelastography parameters
Su, Leon , Secor, Daniel T. , McGary, Alyssa , Nguyen, Michelle , Kinard, Theresa N. , Adamski, Jill , Stoker, Alex D., Frasco, Peter E. , Su, Leon L , McGary, Alyssa K, Nguyen, Michelle C , Jadlowiec, Caroline , Adamksi, Jill , Stoker, Alex D , Jadlowiec, Caroline C. , Williams, Lance A

Liver Transplantation | October 11, 2024 | Volume: 31 | Issue: 4 | Pages: 464-475

10.1097/lvt.0000000000000507 Get It

The use of normothermic machine perfusion (NMP) over static cold storage in liver transplantation has been shown to reduce posttransplant risks of early allograft dysfunction, primary nonfunction, and ischemic cholangiopathy, and its increasing use has played a role in the expanded utilization of marginal livers. While studies have demonstrated improved clinical outcomes using NMP over static cold storage preservation, real-time intraoperative data reflecting the quality and viability of NMP livers is limited. This retrospective, single-center study compared NMP versus static cold storage livers in first-time recipients of liver transplants through the evaluation of synthetic coagulation function as measured by thromboelastography and conventional coagulation testing. Secondarily, transfusion utilization between the 2 cohorts was reviewed. One hundred eighty-six recipients of liver transplants receiving allografts from donors after circulatory death were included in the study, of which 99 (53%) allografts were preserved in static cold storage, and 87 (47%) allografts were placed on the TransMedics Organ Care System. Study findings showed NMP livers supported with the TransMedics Organ Care System were associated with increased synthetic coagulation function and less excess fibrinolysis in the postreperfusion period compared to static cold storage livers, and that these findings were better reflected in real-time with thromboelastography monitoring versus conventional coagulation testing. Following reperfusion, there was a significant decrease in the transfusion of blood products in the NMP group compared with that in the static cold storage group. Overall, we determined that the use of intraoperative thromboelastography can provide real-time data to assess one aspect of reperfusion liver quality and viability.