Citations

Clear

77 citation(s) found for "Johnson, Geoffrey B".

PSMA-RECAP: [177Lu]Lu-PSMA-617 retreatment in metastatic castration-resistant prostate cancer
Bilgin, Gokce Belge , Bilgin, Cem , Packard, Ann T., MD, Miller, Oztekin, Elif Su, Muniz, Miguel, Nikanpour, Yalda , Orme, Jacob J., Kwon, Eugene D., Johnson, Geoffrey B., Sartor, Oliver, Johnson, Derek R., Belge Bilgin, Gokce , Thorpe, Matthew P, Kendi, Ayse Tuba, Packard, Annie T. , Burkett, Brian J. , Thorpe, Matthew , Childs, Daniel S. , Stoff, Ronen , Orme, Jacob J. , Johnson, Geoffrey B , Sartor, Oliver, Kendi, A. Tuba

Mayo Clinic

Frontiers in Oncology | August 28, 2026 | Volume: 16 | Issue: No issue available | Pages: No page available

10.3389/fonc.2026.1831393 | PMID 42729213 Get It

Purpose Radioligand therapy (RLT) with [ 177 Lu] Lu-PSMA-617 has shown significant benefits in metastatic castration-resistant prostate cancer (mCRPC), including prolonged overall survival (OS) and progression-free survival (PFS), as well as improved quality of life. For patients previously treated with [ 177 Lu]Lu-PSMA-617 who subsequently experience disease progression, retreatment with [ 177 Lu] Lu-PSMA-617 has emerged as a potential approach, yet data on the outcomes of RLT retreatment remains limited. This study aimed to assess the efficacy and safety of retreatment RLT in mCRPC. Methods Clinical and imaging data of patients who underwent at least two cycles of [ 177 Lu] Lu-PSMA-617, followed by a second course of treatment with [ 177 Lu] Lu-PSMA-617 between March 2018 and December 2024, were retrospectively reviewed. Endpoints included biochemical response, imaging response, toxicity, PSA-PFS, rPFS, and OS. Radiologic and biochemical responses were evaluated using RECIST 1.1 criteria and PSA levels, respectively. Results A total of 589 patients underwent [ 177 Lu] Lu-PSMA-617 RLT, of whom 20 (3.4%, 20/589) received RLT retreatment. The median age was 71.3 years (range: 63.7–95.2), and the median follow-up was 73.3 months (95% CI, 35.7–77.2 months) after the initial treatment and 21.7 months (95% CI, 16.9–26.0 months) after retreatment. The initial treatment involved a median of 4.5 cycles (range: 2–6). Following the first course of RLT, 15 patients (75%, 15/20) had exhibited a >50% decline in PSA levels, including 9 who achieved a >90% decrease. Additionally, 12 patients (60%, 12/20) had demonstrated a complete or partial imaging response, while 3 (15%, 3/20) patients had stable disease, and 5 (25%, 5/20) patients had progressive radiologic disease. Patients received a median of 4 retreatment cycles (range, 1–6), and the median interval between initial RLT and retreatment RLT was 33.1 months (IQR, 16.2–48.9 months; range, 10.7–58.8 months). A PSA decline of ≥50% was observed in 9 out of 20 patients (45%, 9/20). An imaging response was observed in 10 patients (50%, 10/20), with 4 achieving a complete response and 6 achieving a partial response, whereas 10 patients (50%, 10/20) showed progression. The median PSA-PFS was 9.8 months (95% CI, 4.1–17.9 months), and the median rPFS was 8.2 months (95% CI, 3.3–17.9 months). Eight deaths occurred during follow-up. The estimated Kaplan Meier OS rates were 83.6% at 12 months (95% CI, 57.3%–94.4%) and 53.7% at 24 months (95% CI, 28.3%–73.7%). Grade 2 renal toxicity was observed in one patient (5%, 1/20). Three patients (15%, 3/20) developed Grade 2 anemia. Notably, no grade 3 or grade 4 adverse events were observed during either treatment period. Conclusion In our cohort, retreatment with [¹ 77 Lu]Lu-PSMA-617 RLT was associated with biochemical and imaging responses in some patients, with observed survival outcomes that support further investigation. However, given the retrospective single-arm design and small sample size, large prospective studies are needed to more rigorously evaluate the safety, efficacy, and optimal patient selection for retreatment RLT.
Pathology-Based Validation of Quantitative SPECT/CT in Patients With Suspected Transthyretin Amyloid Cardiomyopathy
Tersalvi, Gregorio , Bois, Melanie C. , Scott, Christopher G. , Carey, Patricia , Garmany, Armin , Davies, Daniel R. , HOFFMAN, Andrew C., Zhang, Jun , Hruska, Carrie B. , Jouni, Hayan, Rodriguez-Porcel, Martin G., Askew, J. Wells , Bois, John P. , Young, Kathleen A. , Anavekar, Nandan S., CHANG, IAN C., Grogan, Martha , Maleszewski, Joseph J. , Homb, Andrew, Redfield, Margaret M. , Dispenzieri, Angela , Maleszewski, Joseph J , Homb, Andrew C, Redfield, Margaret M , Chareonthaitawee, Panithaya , Johnson, Geoffrey B , AbouEzzeddine, Omar F , Hruska, Carrie B , Scott, Christopher , Tersalvi, Gregorio , Carey, Patricia , Rodriguez‐Porcel, Martin , Anavekar, Nandan S., Dispenzieri, Angela , Chareonthaitawee, Panithaya , Johnson, Geoffrey B. , AbouEzzeddine, Omar F.

Mayo Clinic

Circulation: Cardiovascular Imaging | July 23, 2026 | Volume: 19 | Issue: 8 | Pages: No page available

10.1161/circimaging.126.019832 | PMID 42488949 Get It

BACKGROUND: Technetium-based cardiac amyloid radionuclide imaging enables noninvasive diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM), but conventional planar and visual semiquantitative approaches have important limitations. We developed the quantitative 3-dimensional Mayo 3D Score, defined as the ratio of mean left ventricular myocardial radiotracer uptake to right atrial blood-pool uptake using computed tomography (CT)-fused single-photon emission CT (SPECT) volumes of interest, and sought to validate its diagnostic performance against myocardial pathology. METHODS: Consecutive patients who underwent 99m Tc-pyrophosphate SPECT/CT at Mayo Clinic for suspected ATTR-CM between June 2017 and January 2025 with archived myocardial tissue were included. Baseline characteristics, including demographics, echocardiogram, biomarkers, visual semiquantitative, and Mayo 3D Score metrics, were collected. Myocardial specimens underwent histopathologic confirmation of amyloid, with amyloid subtype determination and further semiquantitative grading of amyloid burden and deposition patterns. RESULTS: Among 230 patients (median age, 72 years; 78% male), 107 (47%) had ATTR-CM, of whom 9 had hereditary ATTR-CM. The Mayo 3D Score showed excellent discrimination against pathology (area under the receiver operating characteristic curve, 0.92 [0.88–0.96]), exceeding planar Perugini (0.87 [0.83–0.92]; P =0.006), and heart-to-contralateral lung ratio (0.86 [0.81–0.91]; P =0.004) and comparable to SPECT Perugini (0.90 [0.86–0.94]; P =0.12). A cutoff ≥1.0 yielded 86.0% sensitivity, 92.7% specificity, 91.1% positive predictive value, and 88.4% negative predictive value. Among ATTR-positive cases, the Mayo 3D Score correlated strongly with semiquantitative amyloid burden (Spearman ρ=0.69), was higher in pericellular than nodular deposition patterns ( P <0.001), and was not associated with vascular involvement ( P =0.42). CONCLUSIONS: In patients with suspected ATTR-CM undergoing 99m Tc-pyrophosphate SPECT/CT, the Mayo 3D Score demonstrated superior diagnostic performance compared with planar metrics and comparable to SPECT Perugini, while correlating with myocardial ATTR burden and deposition patterns on pathology. These findings support its integration as a quantitative adjunct within clinical diagnostic ATTR-CM workflows.
Can Hybrid PET/MRI Advance Precision Imaging in Cardiomyopathy?
Kusmirek, Joanna E. , Johnson, Geoffrey B , Johnson, Geoffrey B.

Mayo Clinic

Radiology | June 16, 2026 | Volume: 319 | Issue: 3 | Pages: No page available

10.1148/radiol.261072 | PMID 42301011 Get It

Clinical and Radiometabolic Correlatives of ddPCR Liquid Biopsy for BRAF V600 Mutated Melanoma
Bilgin, Gokce Belge , Nikanpour, Yalda , Kipp, Benjamin R. , Zahrieh, David M. , Block, Matthew S. , Stoff, Ronen , Geiersbach, Katherine B. , Johnson, Geoffrey B. , Markovic, Svetomir N.

Mayo Clinic

International Journal of Cancer | April 21, 2026 | Volume: 159 | Issue: 4 | Pages: 1068-1078

10.1002/ijc.70514 | PMID 42011804 Get It

ABSTRACT Circulating tumor DNA (ctDNA) as a liquid biopsy is an emerging tool used for diagnosis and disease monitoring, yet not all tumors shed DNA equally, thus currently limiting the clinical applicability of this tool. Our institution has developed and validated a droplet digital Polymerase Chain Reaction (ddPCR) ctDNA test for BRAF V600 mutation. We collected data on all BRAF mutated melanoma patients tested with the ddPCR BRAF assay at our institution over the years 2018–2024 and correlated the test results with clinical and radiological baseline parameters, with a focus on Positron Emission Tomography‐Computed Tomography (PET‐CT) data, incorporating both location of lesions and volume of disease. Linear and logistic regression modelling was used to assess possible associations between the baseline parameters and the ctDNA results. We identified 71 BRAF mutated melanoma patients, of which 65 had active disease on imaging studies and 43 had PET‐CT data available for analysis. Multivariate modelling has shown that patients were more likely to have a positive ctDNA result if they had elevated serum lactate dehydrogenase (LDH) (OR = 9.9), had a higher number of lesions on imaging studies (> 10 lesions: OR = 11.3), and if they were younger than 65 (OR = 11.8), with an AUC of 0.84. The PET‐CT calculated total metabolic tumor volume correlated with the quantitative ctDNA result with a Pearson r factor of 0.49. In conclusion, ctDNA ddPCR BRAF testing is easily obtained and might be especially beneficial for patients diagnosed with a clinically aggressive disease, based on elevated LDH, higher PET‐CT metabolic tumor volume, and younger age.
Abstract 2611: Prospective evaluation of 68Ga-PSMA PET imaging in advanced hepatocellular carcinoma patients undergoing first line immunotherapy.
Tran, Nguyen H., Hirdler, Jacob, Antony, Ajith , Torbenson, Michael S., Thompson, Scott M. , Halfdanarson, Thor R., Jin, Zhaohui, Fonkoua, Lionel Aurelien Kankeu, Washburn, Leslie, Revzin, Alexander , Dong, Haidong, Jatoi, Aminah , Borad, M., Bekaii-Saab, T., Gores, Gregory J., Roberts, Lewis R. , Johnson, Geoffrey B., Goenka, Ajit H. , Roberts, Lewis R , Tran, Nguyen H. , Hirdler, Jacob B. , Teske, Jacob J. , Venkatesh, Sudhakar K. , Mahipal, Amit , Torbenson, Michael , Halfdanarson, Thor R, Jin, Zhaohui , Fonkoua, Lionel Aurelien Kankeu , McWilliams, Robert R. , Babiker, Hani M. , Borad, Mitesh J. , Gores, Gregory J. , Johnson, Geoffrey B

Mayo Clinic

Cancer Research | April 3, 2026 | Volume: 86 | Issue: 7_Supplement | Pages: 2611-2611

10.1158/1538-7445.am2026-2611 Get It

Abstract Prostate-specific membrane antigen (PSMA) is highly expressed in tumor-associated neovasculature in hepatocellular carcinoma (HCC), highlighting its promise as a theranostic target. This prospective study aimed to evaluate the utility of novel biomarkers derived from PSMA positron emission tomography computed tomography (PET/CT) to assess treatment response in advanced HCC patients (pts) receiving first line immune checkpoint inhibitors (ICI). Methods: This study (NCT05176223) enrolled unresectable, advanced HCC pts eligible for first-line ICI (atezolizumab/bevacizumab [A/B] or durvalumab/tremelimumab [D/T]) with measurable disease according to RECIST criteria. Primary endpoints: progression-free survival (PFS) per RECIST 1.1 and mRECIST; overall survival (OS); and best overall response. The survival distribution was estimated using the Kaplan-Meier method. Observed agreement is defined as the proportion of pts whose responses, as classified by PET/CT or CT, were concordant. Weighted kappa and Cohen’s kappa were used to quantify the strength of agreement between PET/CT and CT. Pts completed up to five 68Ga-PSMA PET/CT scans and blood collections. Results: Twenty-six pts were enrolled (25 evaluable) between Oct 2022 and Nov 2024. Median follow up was 22.1 months (m) (Q1, Q3: 14.5-23.7). Median age 68 yrs, 72% male, 88% White, 68% Child-Pugh [CP] A, 32% CP B, 32% Barcelona Clinic Liver Cancer [BCLC] stage B, 68% BCLC stage C, 36% with microvascular invasion; 56% received A/B and 40% received D/T treatment. PSMA was positive in 96% of pts at baseline with median SUVmax 14.3 (range 5.1-40.5) and median background liver SUVmax 3.9 (range 2.1-6.8). Median (95%CI) PFS was 5.6 m (4.6-12.5) by both RECIST and mRECIST. Median (95%CI) OS was 18.6 m (7.2-not estimable), with 56% deceased. The observed agreement between PET/CT adapted PERCIST criteria compared to RECIST and mRECIST in determining the best response was 46% and 50% and weighted kappa of 0.63 (95% CI: 0.37-0.90) and 0.66 (0.41-0.92), respectively. Observed agreement between PERCIST compared to RECIST and mRECIST for responders’ assessment was 67% and 71% with Cohen’s kappa of 0.36 (0.03-0.68) and 0.43 (0.11-0.76), respectively. Conclusion: In this cohort, PSMA PET/CT avidity was observed in all but one pt with advanced HCC, each demonstrating moderate to high SUVmax values. Median OS and PFS were consistent with outcomes reported in clinical trials. Response assessment using 68Ga-PSMA PET/CT according to PERCIST criteria showed good concordance with both RECIST and mRECIST standards. Analysis of immune biomarkers is ongoing. Citation Format: Nguyen H. Tran, Jacob Hirdler, Ajith Antony, Jacob Teske, Sudhakar K. Venkatesh, Amit Mahipal, Michael S. Torbenson, Scott M. Thompson, Thor R. Halfdanarson, Zhaohui Jin, Lionel Aurelien Kankeu Fonkoua, Leslie A. Washburn, Alexander Revzin, Haidong Dong, Robert R. Mcwilliams, Aminah Jatoi, Hani M. Babiker, Mitesh J. Borad, Tanios Bekaii-Saab, Gregory J. Gores, Lewis R. Roberts, Geoffrey B. Johnson, Ajit H. Goenka. Prospective evaluation of 68Ga-PSMA PET imaging in advanced hepatocellular carcinoma patients undergoing first line immunotherapy [abstract]. In: Proceedings of the American Association for Cancer Research Annual Meeting 2026; Part 1 (Regular Abstracts); 2026 Apr 17-22; San Diego, CA. Philadelphia (PA): AACR; Cancer Res 2026;86(7 Suppl):Abstract nr 2611.
PSA Zero Radiographic Disease Progression on PSMA PET/CT
Mahmoud, Ahmed M., Day, Carter, Ahmed, E Al-Marzouk, Ahmed, M, Haloi, Rimki , Mahon, Mindie, Nikanpour, Yalda , Orme, Jacob J. , Kendi, MD Ayse Tuba, Johnson, G B, Kwon, E., Andrews, Jack R. , Ahmed, Mohamed E. , Kendi, A. Tuba , Mahmoud, Ahmed , Mahmoud, Ahmed M , Ahmed, Eman E , Ahmed, Mohamed , Childs, Daniel S , Orme, Jacob J , Kendi, A Tuba , Mahon, Mindie, Childs, Daniel S. , Johnson, Geoffrey B , Kwon, Eugene D.

Mayo Clinic

Cancers | March 4, 2026 | Volume: 18 | Issue: 5 | Pages: 831

10.3390/cancers18050831 | PMID 41827764 Get It

Background and Objective: Radiographic progression in prostate cancer (PCa) can occur even when prostate-specific antigen (PSA) levels are undetectable. We aimed to determine the frequency and characteristics of radiographic disease progression (rDP) on PSMA PET/CT in patients with undetectable PSA, referred to as PSA zero rDP. Methods: We analyzed the Mayo Clinic PSMA PET Prostate Cancer Registry to identify patients with rDP on PSMA PET/CT despite undetectable PSA levels. Disease progression was confirmed via biopsy or treatment response. The cohort included patients with non-metastatic and metastatic hormone-sensitive disease, as well as those with castration-resistant prostate cancer at the time of imaging. Overall survival (OS) was estimated using the Kaplan–Meier method. Group comparisons were performed with the log-rank test. Univariate Cox regression was used to identify factors associated with poor OS. Key findings and Limitations: Among 2141 patients imaged between 2021 and 2023, 257 (12%) had PSA zero rDP. Sixty-one percent had initially localized disease; 39% had de novo metastatic disease. Median (IQR) time from diagnosis to PSA zero rDP was 51.9 (18.4–115.5) months. A total of 184 patients (72%) progressed to castration-resistant PCa. Sites of rDP included bone (57%), visceral (15%), lymph node (18%), and local recurrence (10%). During median follow-up of 8.1 (3.5–11.9) months, 5% of patients died. Only visceral metastases were significantly associated with poorer OS (p < 0.0001). Conclusions and Clinical Implications: Prostate cancer patients frequently develop metastatic disease with undetectable PSA values. Our findings suggest the use of periodic advanced imaging techniques, irrespective of PSA value, for more prompt detection and early management of disease progress.
Positron Emission Tomography/Computed Tomography in Cardiac Implantable Electronic Device Infections: Insights From the Emerging Infections Network
McHugh, Jack , Cuervo, Guillermo, Abu-Zeinah, Khalid , Beekmann, Susan E. , Polgreen, Philip M. , Deshmukh, Abhishek J, Johnson, G B, Saleh, Omar M Abu, Baddour, L M, Baddour, Larry M. , Johnson, Geoffrey B. , Cuervo, Guillermo , Chesdachai, Supavit , McHugh, Jack , Cuervo, Guillermo , Abu-Zeinah, Khalid , Beekmann, Susan E , Polgreen, Philip M , Deshmukh, Abhishek J , Johnson, Geoffrey B , Abu Saleh, Omar , DeSimone, Daniel C , Baddour, Larry , Chesdachai, Supavit , Deshmukh, Abhishek , Saleh, Omar Abu , DeSimone, Daniel C.

Mayo Clinic

Open Forum Infectious Diseases | March 3, 2026 | Volume: 13 | Issue: 3 | Pages: No page available

10.1093/ofid/ofag109 | PMID 41852557 Get It

Abstract The practice patterns of fluorine 18–labeled fluorodeoxyglucose positron emission tomography/computed tomography ([18F] FDG PET/CT) use in cardiac implantable electronic device infection remain undefined. Among 258 Emerging Infections Network respondents, 69% reported never or rarely using [18F] FDG PET/CT. Limited access and insurance barriers were the most common obstacles.
Quantitative SPECT/CT for diagnosis of transthyretin amyloid cardiomyopathy: a pathology-based study
Tersalvi, G, Carey, P, Garmany, A, Scott, C G, Homb, A C, Hoffman, A C, Zhang, J, Davies, D R, Askew, J W, Dispenzieri, A, Grogan, M, Chareonthaitawee, P, Johnson, G B, Bois, M C, Abouezzeddine, O F, Tersalvi, Gregorio , Carey, Patricia , Garmany, Armin , Scott, Christopher G. , Homb, Andrew, Davies, Daniel R. , Askew, J. Wells , Dispenzieri, Angela , Grogan, M, Chareonthaitawee, Panithaya , Johnson, Geoffrey B , Bois, Melanie C. , AbouEzzeddine, Omar F.

Mayo Clinic

European Heart Journal | February 5, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.304 Get It

Abstract Background 99mTc-labelled cardiac scintigraphy enables noninvasive diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM). Guidelines recommend using planar semiquantitative (heart to contralateral ratio, H/CL) and single photon emission computed tomography (SPECT) qualitative visual grading for diagnostic interpretation. However, planar imaging has inherent limitations, and visual grading is prone to interobserver variability, underscoring the need for standardized quantitative assessment. We developed a 3D volumetric quantitative score (3D Score) and assessed its diagnostic performance compared to myocardial tissue, the gold standard for ATTR-CM diagnosis. Methods At a single, tertiary referral center, we retrospectively identified consecutive patients from 06/2017 to 06/2024 who underwent 3-hour 99mTc-pyrophosphate or 99mTc-hydroxymethylene diphosphonate planar and SPECT/CT for suspected ATTR-CM and had archived myocardial tissue (biopsy or myectomy). On planar imaging, H/CL was calculated. On SPECT/CT, volumes of interest were drawn around the entire left ventricle (LV), avoiding calcifications, and within the right atrium (RA) blood pool. Mean uptake values were used to calculate the 3D Score (LVmean:RAmean), Fig 1A. Myocardial tissue was stained via sulfated Alcian blue and/or Congo red histochemistry. Once histologically confirmed, amyloid deposits were subtyped by liquid chromatography tandem mass spectrometry. The diagnostic performance of H/CL and 3D Score was assessed using receiver operating characteristic (ROC) curve analysis and predictive characteristics were defined. ROC areas under the curve (AUC) were compared using Delong test. Optimal cutoffs were determined using Youden’s J statistic. Baseline characteristics (demographics, echocardiogram, biomarkers) and H/CL were compared between patients above and below 3D Score cutoff. Results 239 patients were identified (median age 72 [65-78], 78% male, 46% ATTR positive). Median time between cardiac scintigraphy and myocardial tissue collection was 22 (6-65) days. Distribution of the 3D Score stratified by ATTR-CM status is illustrated in Fig 1B-C. The discriminative ability of the 3D Score was excellent (AUC 0.92) and superior to H/CL (0.87, p =0.006, Fig 1D-E). The optimal 3D Score cutoff for identifying ATTR-CM was ≥1.0 with sensitivity of 86%, specificity of 92%, positive predictive value (PPV) 90%, and negative predictive value (NPV) 89%. The optimal H/CL ratio cutoff for identifying ATTR-CM was ≥1.4 with sensitivity of 72%, specificity of 86%, PPV 81%, NPV 78%. Baseline characteristics of the overall cohort stratified by 3D Score are displayed in Table 1. Conclusions The 3D Score demonstrated excellent diagnostic performance for detecting ATTR-CM and was superior to current quantitative metrics. Future studies are needed to externally validate its performance across diverse patient cohorts and imaging centers and to investigate correlation with myocardial amyloid burden. Figure 1
C 11 Choline-PET/CT as a Localization Standard for Reoperative Primary Hyperparathyroidism
Hopmann, Peter , Foster, Trenton R. , Dy, Benzon M. , McKenzie, Travis, Wermers, Robert A. , Lyden, Melanie L. , Lund, Sarah , Foster, Trenton R , Lyden, Melanie, McKenzie, Travis J. , Johnson, Geoffrey B.

Mayo Clinic

The American Surgeon™ | January 6, 2026 | Volume: 92 | Issue: 6 | Pages: 1806-1812

10.1177/00031348251413528 | PMID 41490739 Get It

Introduction Previous studies have demonstrated that C 11 choline positron emission tomography/computed tomography (Choline-PET/CT) can localize abnormal parathyroid glands in the reoperative setting. This study assesses a large volume of patients with primary hyperparathyroidism (1HPT) who underwent Choline-PET/CT to confirm its utility in the setting of negative or equivocal conventional imaging. Methods All patients who underwent Choline-PET/CT for evaluation of 1HPT from July 2017 to July 2024 at a single institution were reviewed. Inclusion criteria were patients who underwent parathyroidectomy and had lab testing to assess for cure (defined as >50% drop from baseline PTH and into normal range, or resolution of hypercalcemia at follow-up). Sensitivity, positive predictive value (PPV), false negative rate (FNR), and accuracy were compared to conventional imaging (neck ultrasound, parathyroid scan, and parathyroid four-dimensional CT (4D-CT)). Subgroup analysis was conducted comparing sensitivity of modalities among index operations and separately in reoperations. Results 84 patients were included for analysis. 61 failed to localize on at least one conventional modality, and 15 failed to localize on all conventional studies. 67 patients (80%) achieved cure, of which 53 were reoperations. Choline-PET/CT outperformed conventional modalities across sensitivity, PPV, FNR, and accuracy. Choline-PET/CT also outperformed conventional modalities when comparing sensitivity in both subgroups. Conclusion C 11 choline-PET/CT is a valuable imaging modality in the reoperative setting and demonstrates utility for index operations. It provides localization when other modalities fail and allows for a high surgical cure rate. Further investigation into its utility as a primary imaging modality is warranted.
Diagnostic Performance and Interpreter Experience of 1-Hour Versus 3-Hour 99m Tc-HMDP Cardiac Amyloid Radionuclide Imaging: A Prospective, Blinded Comparison
Tersalvi, Gregorio , Carey, Patricia , Garmany, Armin , Scott, Christopher G. , Maldonado, Francisco J., Krüger, Leandi , Hruska, Carrie B. , Johnson, Geoffrey B. , Jouni, Hayan, Rodriguez‐Porcel, Martin , Askew, J. Wells , Bois, John P. , Young, Kathleen A. , Anavekar, Nandan S., Grogan, Martha , Homb, Andrew, Zhang, Jun , Kruger, Livia F , Hruska, Carrie B , Johnson, Geoffrey B , Rodriguez-Porcel, Martin G., Askew, J Wells , Young, Kathleen , Grogan, Martha , Dispenzieri, Angela , Chareonthaitawee, Panithaya , Homb, Andrew C, AbouEzzeddine, Omar F , Scott, Christopher , Tersalvi, Gregorio , Carey, Patricia , Zhang, Jun , Maldonado, Francisco J., Dispenzieri, Angela , Chareonthaitawee, Panithaya , AbouEzzeddine, Omar F.

Mayo Clinic

Circulation: Cardiovascular Imaging | December 8, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circimaging.125.018745 | PMID 41355666 Get It

BACKGROUND: Guidelines recommend 3-hour cardiac amyloid radionuclide imaging (CARI) for transthyretin amyloid cardiomyopathy. Citing rapid blood clearance of 99m Tc-hydroxymethylene-diphosphonate (HMDP) and efficient laboratory throughput, 1-hour imaging is increasingly practiced despite limited supporting evidence. We sought to compare diagnostic performance and interpreter experience of 1-hour versus 3-hour HMDP-CARI. METHODS: Consecutive patients with suspected transthyretin amyloid cardiomyopathy (n=114) underwent both 1-hour and 3-hour HMDP single photon emission computed tomography (CT)/CT. Two cardiologist-radiologist reader teams, blinded to imaging timepoint (1 versus 3 hours), assessed overall interpretation, single photon emission CT–based Perugini grade, interpretation difficulty, interpreter confidence, and need for CT-fused images for anatomic localization. Discordant, equivocal, and difficult cases were arbitrated by a third tie-breaking team. The myocardial-to-blood-pool radiotracer uptake ratio (3-dimensional Score) was measured as a surrogate of contrast resolution. RESULTS: Interinterpreter agreement was high at both time points (κ≥0.81), with more cases requiring arbitration at 3 hours versus 1 hour (22% versus 13%; P =0.049). Overall interpretation and Perugini grades were concordant between time points in 111/114 (97%) and 106/114 (93%) patients, respectively. Three patients (3%) were negative at 1 hour but equivocal at 3 hours, all of which were clinically ruled out for transthyretin amyloid cardiomyopathy. Interpreter confidence was comparable at both timepoints (97% versus 95%; P =0.317). Compared with 3-hour imaging, contrast resolution was inferior (lower 3-dimensional score, P <0.001) and CT fusion was more frequently needed (57% versus 31%, P <0.001) at 1-hour imaging. CONCLUSIONS: In a prospective, blinded comparison of 1-hour versus 3-hour HMDP-CARI, diagnostic performance and interpreter experience were similar, with readers requesting CT fusion more frequently at 1 hour to optimize myocardial-to-blood pool discrimination.