Citations 5

Pathology-Based Validation of Quantitative SPECT/CT in Patients With Suspected Transthyretin Amyloid Cardiomyopathy

Circulation: Cardiovascular Imaging | July 23, 2026 | Volume: 19 | Issue: 8 | Pages: No page available

10.1161/circimaging.126.019832 | PMID 42488949

BACKGROUND: Technetium-based cardiac amyloid radionuclide imaging enables noninvasive diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM), but conventional planar and visual semiquantitative approaches have important limitations. We developed the quantitative 3-dimensional Mayo 3D Score, defined as the ratio of mean left ventricular myocardial radiotracer uptake to right atrial blood-pool uptake using computed tomography (CT)-fused single-photon emission CT (SPECT) volumes of interest, and sought to validate its diagnostic performance against myocardial pathology. METHODS: Consecutive patients who underwent 99m Tc-pyrophosphate SPECT/CT at Mayo Clinic for suspected ATTR-CM between June 2017 and January 2025 with archived myocardial tissue were included. Baseline characteristics, including demographics, echocardiogram, biomarkers, visual semiquantitative, and Mayo 3D Score metrics, were collected. Myocardial specimens underwent histopathologic confirmation of amyloid, with amyloid subtype determination and further semiquantitative grading of amyloid burden and deposition patterns. RESULTS: Among 230 patients (median age, 72 years; 78% male), 107 (47%) had ATTR-CM, of whom 9 had hereditary ATTR-CM. The Mayo 3D Score showed excellent discrimination against pathology (area under the receiver operating characteristic curve, 0.92 [0.88–0.96]), exceeding planar Perugini (0.87 [0.83–0.92]; P =0.006), and heart-to-contralateral lung ratio (0.86 [0.81–0.91]; P =0.004) and comparable to SPECT Perugini (0.90 [0.86–0.94]; P =0.12). A cutoff ≥1.0 yielded 86.0% sensitivity, 92.7% specificity, 91.1% positive predictive value, and 88.4% negative predictive value. Among ATTR-positive cases, the Mayo 3D Score correlated strongly with semiquantitative amyloid burden (Spearman ρ=0.69), was higher in pericellular than nodular deposition patterns ( P <0.001), and was not associated with vascular involvement ( P =0.42). CONCLUSIONS: In patients with suspected ATTR-CM undergoing 99m Tc-pyrophosphate SPECT/CT, the Mayo 3D Score demonstrated superior diagnostic performance compared with planar metrics and comparable to SPECT Perugini, while correlating with myocardial ATTR burden and deposition patterns on pathology. These findings support its integration as a quantitative adjunct within clinical diagnostic ATTR-CM workflows.
Quantitative SPECT/CT for diagnosis of transthyretin amyloid cardiomyopathy: a pathology-based study

European Heart Journal | February 5, 2026 | Volume: 46 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehaf784.304

Abstract Background 99mTc-labelled cardiac scintigraphy enables noninvasive diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM). Guidelines recommend using planar semiquantitative (heart to contralateral ratio, H/CL) and single photon emission computed tomography (SPECT) qualitative visual grading for diagnostic interpretation. However, planar imaging has inherent limitations, and visual grading is prone to interobserver variability, underscoring the need for standardized quantitative assessment. We developed a 3D volumetric quantitative score (3D Score) and assessed its diagnostic performance compared to myocardial tissue, the gold standard for ATTR-CM diagnosis. Methods At a single, tertiary referral center, we retrospectively identified consecutive patients from 06/2017 to 06/2024 who underwent 3-hour 99mTc-pyrophosphate or 99mTc-hydroxymethylene diphosphonate planar and SPECT/CT for suspected ATTR-CM and had archived myocardial tissue (biopsy or myectomy). On planar imaging, H/CL was calculated. On SPECT/CT, volumes of interest were drawn around the entire left ventricle (LV), avoiding calcifications, and within the right atrium (RA) blood pool. Mean uptake values were used to calculate the 3D Score (LVmean:RAmean), Fig 1A. Myocardial tissue was stained via sulfated Alcian blue and/or Congo red histochemistry. Once histologically confirmed, amyloid deposits were subtyped by liquid chromatography tandem mass spectrometry. The diagnostic performance of H/CL and 3D Score was assessed using receiver operating characteristic (ROC) curve analysis and predictive characteristics were defined. ROC areas under the curve (AUC) were compared using Delong test. Optimal cutoffs were determined using Youden’s J statistic. Baseline characteristics (demographics, echocardiogram, biomarkers) and H/CL were compared between patients above and below 3D Score cutoff. Results 239 patients were identified (median age 72 [65-78], 78% male, 46% ATTR positive). Median time between cardiac scintigraphy and myocardial tissue collection was 22 (6-65) days. Distribution of the 3D Score stratified by ATTR-CM status is illustrated in Fig 1B-C. The discriminative ability of the 3D Score was excellent (AUC 0.92) and superior to H/CL (0.87, p =0.006, Fig 1D-E). The optimal 3D Score cutoff for identifying ATTR-CM was ≥1.0 with sensitivity of 86%, specificity of 92%, positive predictive value (PPV) 90%, and negative predictive value (NPV) 89%. The optimal H/CL ratio cutoff for identifying ATTR-CM was ≥1.4 with sensitivity of 72%, specificity of 86%, PPV 81%, NPV 78%. Baseline characteristics of the overall cohort stratified by 3D Score are displayed in Table 1. Conclusions The 3D Score demonstrated excellent diagnostic performance for detecting ATTR-CM and was superior to current quantitative metrics. Future studies are needed to externally validate its performance across diverse patient cohorts and imaging centers and to investigate correlation with myocardial amyloid burden. Figure 1
Diagnostic Performance and Interpreter Experience of 1-Hour Versus 3-Hour 99m Tc-HMDP Cardiac Amyloid Radionuclide Imaging: A Prospective, Blinded Comparison

Circulation: Cardiovascular Imaging | December 8, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circimaging.125.018745 | PMID 41355666

BACKGROUND: Guidelines recommend 3-hour cardiac amyloid radionuclide imaging (CARI) for transthyretin amyloid cardiomyopathy. Citing rapid blood clearance of 99m Tc-hydroxymethylene-diphosphonate (HMDP) and efficient laboratory throughput, 1-hour imaging is increasingly practiced despite limited supporting evidence. We sought to compare diagnostic performance and interpreter experience of 1-hour versus 3-hour HMDP-CARI. METHODS: Consecutive patients with suspected transthyretin amyloid cardiomyopathy (n=114) underwent both 1-hour and 3-hour HMDP single photon emission computed tomography (CT)/CT. Two cardiologist-radiologist reader teams, blinded to imaging timepoint (1 versus 3 hours), assessed overall interpretation, single photon emission CT–based Perugini grade, interpretation difficulty, interpreter confidence, and need for CT-fused images for anatomic localization. Discordant, equivocal, and difficult cases were arbitrated by a third tie-breaking team. The myocardial-to-blood-pool radiotracer uptake ratio (3-dimensional Score) was measured as a surrogate of contrast resolution. RESULTS: Interinterpreter agreement was high at both time points (κ≥0.81), with more cases requiring arbitration at 3 hours versus 1 hour (22% versus 13%; P =0.049). Overall interpretation and Perugini grades were concordant between time points in 111/114 (97%) and 106/114 (93%) patients, respectively. Three patients (3%) were negative at 1 hour but equivocal at 3 hours, all of which were clinically ruled out for transthyretin amyloid cardiomyopathy. Interpreter confidence was comparable at both timepoints (97% versus 95%; P =0.317). Compared with 3-hour imaging, contrast resolution was inferior (lower 3-dimensional score, P <0.001) and CT fusion was more frequently needed (57% versus 31%, P <0.001) at 1-hour imaging. CONCLUSIONS: In a prospective, blinded comparison of 1-hour versus 3-hour HMDP-CARI, diagnostic performance and interpreter experience were similar, with readers requesting CT fusion more frequently at 1 hour to optimize myocardial-to-blood pool discrimination.
Bayesian penalized likelihood PET reconstruction impact on quantitative metrics in diffuse large B-cell lymphoma

Medicine | February 10, 2023 | Volume: 102 | Issue: 6 | Pages: e32665

10.1097/md.0000000000032665 | PMID 36820562

Evaluate the quantitative, subjective (Deauville score [DS]) and reader agreement differences between standard ordered subset expectation maximization (OSEM) and Bayesian penalized likelihood (BPL) positron emission tomography (PET) reconstruction methods. A retrospective review of 104 F-18 fluorodeoxyglucose PET/computed tomography (CT) exams among 52 patients with diffuse large B-cell lymphoma. An unblinded radiologist moderator reviewed both BPL and OSEM PET/CT exams. Four blinded radiologists then reviewed the annotated cases to provide a visual DS for each annotated lesion. Significant (P < .001) differences in BPL and OSEM PET methods were identified with greater standard uptake value (SUV) maximum and SUV mean for BPL. The DS was altered in 25% of cases when BPL and OSEM were reviewed by the same radiologist. Interobserver DS agreement was higher for OSEM (>1 cm lesion = 0.89 and ≤1 cm lesion = 0.84) compared to BPL (>1 cm lesion = 0.85 and ≤1 cm lesion = 0.81). Among the 4 readers, average intraobserver visual DS agreement between OSEM and BPL was 0.67 for lesions >1cm and 0.4 for lesions ≤1 cm. F-18 Fluorodeoxyglucose PET/CT of diffuse large B-cell lymphoma reconstructed with BPL has higher SUV values, altered DSs and reader agreement when compared to OSEM. This report finds volumetric PET measurements such as metabolic tumor volume to be similar between BPL and OSEM PET reconstructions. Efforts such as adoption of European Association Research Ltd accreditation should be made to harmonize PET data with an aim at balancing the need for harmonization and sensitivity for lesion detection.
Cardiac Nuclear Medicine: Techniques, Applications, and Imaging Findings

RadioGraphics | December 9, 2022 | Volume: 43 | Issue: 1 | Pages: No page available

10.1148/rg.220027 | PMID 36490208