Back to Authors

Tersalvi, Gregorio

0000-0003-1845-1777

Mayo Clinic

Department of Cardiovascular Medicine, Mayo Clinic, Rochester, Minnesota, United States.

Citations 4

Pathology-Based Validation of Quantitative SPECT/CT in Patients With Suspected Transthyretin Amyloid Cardiomyopathy

Circulation: Cardiovascular Imaging | July 23, 2026 | Volume: 19 | Issue: 8 | Pages: No page available

10.1161/circimaging.126.019832 | PMID 42488949

BACKGROUND: Technetium-based cardiac amyloid radionuclide imaging enables noninvasive diagnosis of transthyretin amyloid cardiomyopathy (ATTR-CM), but conventional planar and visual semiquantitative approaches have important limitations. We developed the quantitative 3-dimensional Mayo 3D Score, defined as the ratio of mean left ventricular myocardial radiotracer uptake to right atrial blood-pool uptake using computed tomography (CT)-fused single-photon emission CT (SPECT) volumes of interest, and sought to validate its diagnostic performance against myocardial pathology. METHODS: Consecutive patients who underwent 99m Tc-pyrophosphate SPECT/CT at Mayo Clinic for suspected ATTR-CM between June 2017 and January 2025 with archived myocardial tissue were included. Baseline characteristics, including demographics, echocardiogram, biomarkers, visual semiquantitative, and Mayo 3D Score metrics, were collected. Myocardial specimens underwent histopathologic confirmation of amyloid, with amyloid subtype determination and further semiquantitative grading of amyloid burden and deposition patterns. RESULTS: Among 230 patients (median age, 72 years; 78% male), 107 (47%) had ATTR-CM, of whom 9 had hereditary ATTR-CM. The Mayo 3D Score showed excellent discrimination against pathology (area under the receiver operating characteristic curve, 0.92 [0.88–0.96]), exceeding planar Perugini (0.87 [0.83–0.92]; P =0.006), and heart-to-contralateral lung ratio (0.86 [0.81–0.91]; P =0.004) and comparable to SPECT Perugini (0.90 [0.86–0.94]; P =0.12). A cutoff ≥1.0 yielded 86.0% sensitivity, 92.7% specificity, 91.1% positive predictive value, and 88.4% negative predictive value. Among ATTR-positive cases, the Mayo 3D Score correlated strongly with semiquantitative amyloid burden (Spearman ρ=0.69), was higher in pericellular than nodular deposition patterns ( P <0.001), and was not associated with vascular involvement ( P =0.42). CONCLUSIONS: In patients with suspected ATTR-CM undergoing 99m Tc-pyrophosphate SPECT/CT, the Mayo 3D Score demonstrated superior diagnostic performance compared with planar metrics and comparable to SPECT Perugini, while correlating with myocardial ATTR burden and deposition patterns on pathology. These findings support its integration as a quantitative adjunct within clinical diagnostic ATTR-CM workflows.
Diagnostic challenges in isolated cardiac sarcoidosis

ESC Heart Failure | June 2, 2026 | Volume: 13 | Issue: 3 | Pages: No page available

10.1093/eschf/xvag159 | PMID 42234828

Abstract Isolated cardiac sarcoidosis (iCS), defined by granulomatous inflammation limited to the myocardium, represents the most diagnostically challenging and prognostically adverse form of sarcoidosis. As it is fundamentally a diagnosis of exclusion, iCS diagnosis relies on the absence of extracardiac sarcoid and the integration of multimodality imaging, endomyocardial biopsy, and molecular testing, each with inherent limitations. Cardiac magnetic resonance and positron emission tomography provide complementary assessment of inflammation, fibrosis, and ventricular function, enhancing diagnostic confidence. Electroanatomic mapping-guided biopsy may improve histologic yield, whereas genetic testing helps exclude phenocopies such as arrhythmogenic, hypertrophic, or dilated cardiomyopathies. Circulating biomarkers remain non-specific but may complement imaging-based algorithms. Future research should focus on harmonized imaging protocols, non-FDG radiotracers, and molecular tissue profiling to refine activity assessment and guide therapy. Multimodal, probability-based frameworks represent the most promising approach for earlier, more accurate diagnosis and risk stratification in iCS.
Interplay of pulmonary circulation, cardiac filling pressures, and sympathovagal balance in exercise-induced hyperventilation among cardiopulmonary disorders

American Journal of Physiology-Regulatory, Integrative and Comparative Physiology | March 23, 2026 | Volume: 330 | Issue: 5 | Pages: R480-R488

10.1152/ajpregu.00094.2025 | PMID 41870396

The results underscore a multifaceted interaction among cardiopulmonary hemodynamics, right heart pressures, ventilatory response, and autonomic regulation. In particular, altered RV-PA coupling correlated with heightened sympathetic drive, indicating that cardiopulmonary efficiency and hemodynamics may influence central autonomic outputs. This suggests that mechanical stress or overload in the right heart could modulate sympathovagal balance, thereby contributing to altered autonomic responses during exercise in patients with cardiopulmonary disorders.
Diagnostic Performance and Interpreter Experience of 1-Hour Versus 3-Hour 99m Tc-HMDP Cardiac Amyloid Radionuclide Imaging: A Prospective, Blinded Comparison

Circulation: Cardiovascular Imaging | December 8, 2025 | Volume: 19 | Issue: 1 | Pages: No page available

10.1161/circimaging.125.018745 | PMID 41355666

BACKGROUND: Guidelines recommend 3-hour cardiac amyloid radionuclide imaging (CARI) for transthyretin amyloid cardiomyopathy. Citing rapid blood clearance of 99m Tc-hydroxymethylene-diphosphonate (HMDP) and efficient laboratory throughput, 1-hour imaging is increasingly practiced despite limited supporting evidence. We sought to compare diagnostic performance and interpreter experience of 1-hour versus 3-hour HMDP-CARI. METHODS: Consecutive patients with suspected transthyretin amyloid cardiomyopathy (n=114) underwent both 1-hour and 3-hour HMDP single photon emission computed tomography (CT)/CT. Two cardiologist-radiologist reader teams, blinded to imaging timepoint (1 versus 3 hours), assessed overall interpretation, single photon emission CT–based Perugini grade, interpretation difficulty, interpreter confidence, and need for CT-fused images for anatomic localization. Discordant, equivocal, and difficult cases were arbitrated by a third tie-breaking team. The myocardial-to-blood-pool radiotracer uptake ratio (3-dimensional Score) was measured as a surrogate of contrast resolution. RESULTS: Interinterpreter agreement was high at both time points (κ≥0.81), with more cases requiring arbitration at 3 hours versus 1 hour (22% versus 13%; P =0.049). Overall interpretation and Perugini grades were concordant between time points in 111/114 (97%) and 106/114 (93%) patients, respectively. Three patients (3%) were negative at 1 hour but equivocal at 3 hours, all of which were clinically ruled out for transthyretin amyloid cardiomyopathy. Interpreter confidence was comparable at both timepoints (97% versus 95%; P =0.317). Compared with 3-hour imaging, contrast resolution was inferior (lower 3-dimensional score, P <0.001) and CT fusion was more frequently needed (57% versus 31%, P <0.001) at 1-hour imaging. CONCLUSIONS: In a prospective, blinded comparison of 1-hour versus 3-hour HMDP-CARI, diagnostic performance and interpreter experience were similar, with readers requesting CT fusion more frequently at 1 hour to optimize myocardial-to-blood pool discrimination.