The estimation of surgical blood loss is routinely performed during and after surgical procedures and has morbidity and mortality implications related to the risk of under- and over-resuscitation. The strategies for estimating surgical blood loss include visual estimation, the gravimetric method, the colorimetric method, formula-based methods, and other techniques (e.g., cell salvage). Currently, visual estimation continues to be the most widely used technique. In addition, unique considerations exist when these techniques are applied to various clinical settings such as massive transfusion, cardiac surgery, and obstetrics. Ultimately, when using estimated surgical blood loss to guide perioperative fluid management and transfusion thresholds, it is also important to mitigate the risks associated with resuscitation by targeting a goal-directed fluid therapy approach by utilizing markers of fluid-responsiveness to optimize stroke volume (cardiac output) and delivery of oxygen.
Applications of Mass Spectrometry Proteomic Methods to Immunoglobulins in the Clinical Laboratory
Abstract Background Immunoglobulin (Ig) measurements in the clinical laboratory have been traditionally performed by nephelometry, turbidimetry, electrophoresis, and ELISA assays. Mass spectrometry (MS) measurements have the potential to provide deeper insights on the nature of these markers. Content Different approaches—top-down, middle-down, or bottom-up—have been described for measuring specific Igs for endogenous monoclonal immunoglobulins (M-proteins) and exogenous therapeutic monoclonal antibody therapies (t-mAbs). Challenges arise in distinguishing the Ig of interest from the polyclonal Ig background. MS is emerging as a practical method to provide quantitative analysis and information about structural and clonal features that are not easily determined by current clinical laboratory methods. This review discusses clinically implemented examples, including isotyping and quantification of M-proteins and quantitation of t-mAbs within the polyclonal Ig background, as examples of how MS can enhance our detection and characterization of Igs. Summary This review of current clinically available MS proteomic tests for Igs highlights both analytical and nonanalytical challenges for implementation. Given the new insight into Igs from these methods, it is hoped that vendors, laboratorians, healthcare providers, and payment systems can work to overcome these challenges and advance the care of patients.
Implementation of a Mass Spectroscopic Method (Mass-Fix) to Replace Traditional Electrophoresis Methods for Patients with Monoclonal Gammopathies
Background The detection, isotyping and quantitation of over-expressed immunoglobulin(s) (Igs) (M-protein) is key for diagnosing and monitoring patients with monoclonal gammopathies. Traditionally, our lab has used a combination of agarose gel protein electrophoresis (SPEP) and immunofixation electrophoresis (IFE) for these purposes. In 2018, a mass spectrometric method (Mass-Fix) was implemented to replace IFE for M-protein isotyping. This work documents the validation of a quantitative version (Q-Mass-Fix) to replace both SPEP and IFE. Methods 24,645 samples submitted for M-protein testing between 7/2018 and 9/2023 with quantitative IgG, IgA and IgM measurements, Mass-Fix analysis and SPEP results were utilized for this study. A separate cohort of 100,000 M-protein negative samples were utilized to mathematically model the spectral shapes IgG, IgA and IgM polyclonal background. To detect M-proteins, software was developed that fits the polyclonal Ig portion of the spectra and M-proteins are detected as peaks above the polyclonal background. M-proteins isotypes are determined by matching similar peaks in spectra in 5 sperate immuno enrichments (IgG, IgA, IgM, kappa and lambda). M-protein quantitation was obtained by multiplying total M-protein isotype quantity by the fraction area of the M-protein in the spectra. M-protein dilutional studies were used to examine the linearity and level of detection of Q-Mass-Fix. Results SPEP and Q-Mass-Fix M-protein quantitation had the best agreement between the range of 10 to 40 g/L. Below 10 g/L, Q-Mass Fix had on average, lower M-protein values. Above 40 g/dL, Q-Mass-Fix values were on average, higher than SPEP. The automated isotyping assignment was 98.8 percent consistent with the isotype assigned by visual inspection. Dilutional studies revealed that Q-Mass-Fix quantitation was linear over a range of 70 to 0.04 g/L (slope 1.0, r2 0.99) with an analytical limit of quantitation of 0.1 g/L and a limit of detection of 0.04 g/L. Conclusion Q-Mass-Fix represents a significant improvement in comparison to our current SPEP method. Q-Mass-Fix is more capable of removing the interference of polyclonal Igs below 10 g/L and is not subjective to the dye saturation effect at high M-protein levels. The increased analytical measuring range and improved limit of detection of detection could be beneficial in tracking patient's response. Q-Mass Fix is more automated than SPEP and the workflow in our laboratory.
Clonal Persistence of Anti-PF4 Antibodies in VITT Represents an MGTS-like State
Background: Vaccine-induced immune thrombotic thrombocytopenia (VITT) is a severe thrombotic thrombocytopenia that predominantly occurs after adenoviral vector-based vaccines. VITT patients produce anti-platelet factor 4 (PF4) antibodies with restricted clonality (i.e., mono/oligoclonal) with lambda light chains. Long-term follow-up studies in VITT show a disconnect in the persistence of anti-PF4 antibodies, whereby ELISA-positive antibodies persist significantly longer than platelet-activating antibodies. The mechanistic basis of this is unclear and could be explained by a couple of hypotheses: (1) Epitope spreading where, with time, the specificity of platelet-activating anti-PF4 antibodies may “spread” to recognize only PF4 complexed to heparin vs. (2) Persistence of clonally restricted platelet-activating anti-PF4 antibodies which decrease in titers with time such that their levels are insufficient to crosslink platelet FcGRIIa and induce platelet activation. Methods: Acute, convalescent patient sera and affinity-purified anti-PF4 antibodies were evaluated in antigen-based, functional (platelet-activation-based), and mass spectrometry studies as previously described (Blood, 2022 Jul 7;140(1):73-77). The median time to last follow-up was 243 days after the acute episode (range: 114-664 days). Results: Follow-up samples were obtained from 6 VITT patients after Ad26.COV2.S vaccination. At last follow-up, anti-PF4 IgG antibodies reactive in PF4/polyanion ELISA were detected in the sera of 5/6 VITT patients. However, only one of these samples stimulated platelet activation in the PF4-dependent P-selectin expression assay (PEA; 199 days after acute presentation). Affinity-purified anti-PF4 antibodies were detected by ELISA in all follow-up samples and three of the six affinity-purified anti-PF4 antibody samples activated platelets in the PEA. Four of the six VITT patients demonstrated a monoclonal anti-PF4 antibody, while one each had a biclonal and triclonal profile. Five VITT patients produced IgG lambda light chain antibodies, while one produced an IgG kappa. All six VITT patients demonstrated synonymous anti-PF4 antibody profiles when comparing acute and follow-up antibody repertoires, without evidence of VITT patients producing new anti-PF4 antibodies after the acute episode. In all cases, levels of anti-PF4 antibodies were significantly lower in convalescent samples relative to acute samples. Given this data on the persistence of clonally-restricted VITT antibodies, samples from another VITT patient with thrombocytopenia (100-150,000/uL) persisting for more than three years were similarly evaluated. This patient, who experienced severe thrombosis after ChAdOx1 nCoV19 vaccination, demonstrated persistent ELISA and PEA positivity even three years after symptom onset but had not experienced breakthrough thrombosis while on anticoagulation therapy. Serum protein electrophoresis (SPEP) did not detect a monoclonal gammopathy. Anti-PF4 antibodies immuno-enriched from a sample obtained >2 years after acute presentation demonstrated a monoclonal profile. While non-availability of an acute sample for anti-PF4 antibody characterization precluded a firm determination of whether this “Long VITT” case represented a subset of monoclonal gammopathy of thrombotic significance (MGTS; Blood 2023 Apr 6;141(14):1772-1776; New Eng J Med 2024 Aug 8), the chronicity of thrombocytopenia, presence of a monoclonal anti-PF4 antibody and persistently positive anti-PF4 serology supports this diagnosis. Conclusions. Clonally-restricted VITT antibodies persist for months-years with no evidence for the production of novel anti-PF4 antibodies after the acute event. Decreased abundance of anti-PF4 antibodies leads to negative functional results with follow up samples. Some platelet-activating antibodies can persist for very long periods (>3 years) and mediate persistent thrombocytopenia, representing an SPEP-negative MGTS-like state. This study also demonstrates the first example of a VITT antibody with a kappa light chain. The requirement for anticoagulation in patients demonstrating ELISA-positive/functional test-negative results is not clear, but the persistence of mono/oligoclonal anti-PF4 antibodies raises the possibility for the upregulation of pathogenic antibody production in proinflammatory settings.
Impact of Serial Serum Free Light Chain Measurements on Response and Progression Assessments in Multiple Myeloma Patients with Measurable Disease
Introduction: Uniform assessment of response to treatment is crucial to managing myeloma and developing new therapies. Measurement of the monoclonal protein (s) secreted by the myeloma cells forms the cornerstone of disease assessment in MM and has primarily been performed by electrophoretic methods in the serum and urine, as well as assessment of free light chains in the serum. According to international myeloma working group (IMWG) guidelines, serial serum-free light chain (sFLC) is included in MM response assessment to define stringent complete response and for evaluating partial response (PR) or progressive disease (PD) in non/oligo-secretory MM. This study aims to determine the added value of serial sFLC measurements in monitoring response and progression in MM with measurable disease by comparing the kinetics of FLC with M spike measured by electrophoresis in serum or urine. Methods: This retrospective observational study included newly diagnosed MM patients evaluated at Mayo Clinic in Rochester between 2011-2021. All patients had measurable sFLC (involved FLC level ≥ 10mg/dL, with abnormal sFLC ratio) along with measurable M-protein by serum or urine protein electrophoresis at diagnosis. Serial measurements of sFLC and M-protein by electrophoresis (sPEP/uPEP) were prospectively collected from the electronic medical records at different time points. FLC-response and FLC-PD were evaluated based on IMWG criteria. Results: The study cohort included 839 patients, 52% with measurable M protein by electrophoresis in serum, 27% in both serum and urine, and 21% in urine-only. A significant association was observed between sFLC and electrophoretic response during the induction and at the time of best response (p <.001). Serum FLC showed a comparable response rate of 98% (≥ PR) at the time of best electrophoretic response (p <.001). Ninety-nine percent of early FLC responders eventually achieved an overall response by sPEP/uPEP (p <.001). In the urine-only group, 99% achieved at least a PR by uPEP, and all showed at least a PR based on sFLC. We observed comparable median percentage changes in serial dFLC and urine M-protein, with parallel trends (p <0.001). The correlation coefficients between the change of sFLC and urine M-protein showed a moderate/strong correlation with coefficients (r) of 0.791, 0.597, 0598, 0.545, after cycles 1, 2, 3, 4, respectively, (p < .001). The response for all cohorts was detected earlier by dFLC (median time 1.1 months, 95% CI: 1.06-1.17), in comparison with serum M-protein (1.5 months, 95% CI: 1.40-1.62) and urine M-protein (2.8 months, 95% CI: 2.42-3.10) with p < .001. In the urine-only group, earlier detection of response by dFLC (1.1 months, 95% CI: 1.00-1.2) was observed, compared to urine M-protein (2.4 months, 95% CI: 2.00-2.7) (p <.001). After a median follow-up of 52 (IQR 27.6, 72.3) months, 56% had PD: 62% by s-FLC, 56% by serum M-protein, and 24% by urine M-protein. Among patients with PD by uPEP, all except one patient met sFLC-PD. Within patients with PD, sFLC was the only detectable tumor marker in 12% of cases at the time of the second line of treatment. After four cycles of induction, there was no difference in PFS between VGPR response determined by sFLC, sPEP, and uPEP (p =0.538). The median second-PFS for patients with onlysFLC-PD was similar to those with urine M-protein PD with or without sFLC-PD (HR 1.28, 95% CI =0.77-2.13. p 0.334). However, the median overall survival (OS) from the first relapse was significantly better for patients with onlysFLC-PD than those with urine M-protein PD (HR 1.87, 95% CI =1.07-3.27. p 0.026). Conclusions: In this study, achieving sFLC-VGPR has a similar impact on PFS as electrophoretic-VGPR after induction, indicating that serial sFLC can potentially replace the requirement for urine M-protein response (< 100mg in 24-hours urine) as part of the electrophoretic-VGPR criteria, as required by IMWG. A similar response rate between sFLC and urine paraprotein confirms the current cutoffs (90% for urine and 50% for dFLC for VGPR) used for response categories for s-FLC. We also observed that in 12% of patients with PD, sFLC was the only marker of progression, highlighting the value of serial s-FLC in monitoring relapse. In conclusion, our study supports the integration of serial sFLC measurements for monitoring response and progression in MM, even with electrophoretic measurable disease.
Clinical and Diagnostic Complexity in ELISA- and SRA-Negative Monoclonal Gammopathy of Thrombotic Significance
Monoclonal gammopathy of thrombotic significance (MGTS) is a recently recognized thrombophilia characterized by the production of a monoclonal antibody that binds to platelet factor 4 (PF4) and stimulates platelet activation (Blood. 2022 Jul 7;140(1):73-77). Typical signs of MGTS include a history of recurrent thrombosis, persistent thrombocytopenia, and positive laboratory results in PF4/polyanion enzyme-linked immunosorbent assay (ELISA) and serotonin release assay (SRA) testing, as in the related thrombotic disorder heparin-induced thrombocytopenia (HIT). Here, we present a case of MGTS, presenting with transient thrombocytopenia coincident with thrombotic episodes and negative test results in SRA and PF4/polyanion-based testing platforms (ELISAs and automated assays). A 56-year-old male patient initially presented with acute left lower extremity deep vein thrombosis (DVT) and a pulmonary embolism. Following the administration of warfarin, the patient experienced a second DVT four months later and was transitioned to a factor Xa inhibitor. Fifty-two months later, the patient developed occlusion of the splenic and superior mesenteric veins despite additional anticoagulation therapy. Further testing led to a diagnosis of an IgG2 kappa monoclonal gammopathy of undetermined significance (MGUS). Eleven months later, the patient again suffered breakthrough thrombosis, specifically radial artery thrombosis, and a thrombotic cerebrovascular accident, leading to the addition of aspirin to the patient's treatment regimen. Notably, where detailed blood counts were available in the patient's clinical history, the patient experienced only transient thrombocytopenia coinciding with his two most recent thrombotic episodes and has had platelet counts in the normal range in the four-year period since his last thrombotic event. After initiating dual anticoagulant/antiplatelet therapy, the patient has not developed recurrent thrombocytopenia or new thrombotic events. Antigen-based and functional testing for HIT antibodies (ELISA, SRA, and automated immunoassays) were negative in this patient, unlike in the previously described index case of MGTS, where serological testing mimicked classical HIT serology (i.e., HIT ELISA and SRA positivity). The sample was also non-reactive in a vaccine-induced immune thrombotic thrombocytopenia (VITT)-specific ELISA employing uncomplexed PF4 targets, as previously described (Am J Hematol. 2022 May;97(5):519-526). Conversely, the patient's antibody consistently stimulated platelet activation in a PF4- and IgG-dependent manner in functional testing using PF4-treated platelets. This included PF4-treated platelets that were freshly isolated and used in the PF4-dependent P-selectin expression assay (PEA) and cryopreserved platelets used in the thrombospondin-1 release assay. Interestingly, consistently positive PEA results have been documented from four samples over the last four years, during which the patient had normal platelet counts. To further characterize the patient's IgG2 MGUS antibody, the patient's monoclonal was immuno-enriched. Patient sera and the immuno-enriched MGUS were then compared by mass spectrometry, which generated identical mass profiles. After confirming the effective enrichment of the patient's MGUS by mass spectrometry, the antibody was de novo sequenced or “reverse-engineered” to obtain the antibody's amino acid sequence. The antibody was then expressed and tested in ELISA-based and functional platelet assays. Importantly, the recombinant antibody replicated the PF4-dependent platelet activation observed with patient serum and did not bind PF4/polyanion targets in ELISA testing. Together, these data strongly support the identification of a new class of ELISA- and SRA-negative anti-PF4 monoclonal antibodies that cause MGTS. This case illustrates the diagnostic challenges in MGTS. MGTS patients may not exhibit persistent thrombocytopenia, and diagnostic tests for detecting HIT antibodies may be ineffective in accurately diagnosing this new thrombophilia. This case emphasizes the importance of reviewing platelet counts in the peri-thrombotic period to recognize transient thrombocytopenia and establishes the utility of PF4-enhanced functional assays to detect pathogenic anti-PF4 antibodies, even in settings where classical HIT testing (i.e., ELISA/SRA) is negative.
Rationale and Logistics of Continuous Infusion Cephalosporin Antibiotics
Cephalosporins have traditionally been administered as an intermittent infusion. With the knowledge that cephalosporins demonstrate a time-dependent pharmacodynamic profile, administration via continuous infusion may provide more effective antibiotic exposure for successful therapy. Proposed benefits of administration via continuous infusion include less IV manipulation, decreased potential for antibiotic resistance, and potential cost savings. The objective of this review was to provide a detailed assessment of available evidence for the use of continuous infusion cephalosporins and practical dosing and administration recommendations. Studies were gathered and assessed for inclusion via a literature search of PubMed and Ovid MEDLINE using mesh terms [“continuous infusion” and “cephalosporin”], “intermittent infusion”, [“intermittent versus continuous” and “cephalosporin”], “continuous infusion cephalosporin”, as well as specific drug names. References from included studies were also evaluated for inclusion. Data which compared the two administration methods (continuous infusion vs. intermittent infusion) were evaluated. Thirty-five studies were analyzed among several cephalosporins with variable delivery. Dosing regimens utilized in the selected studies were assessed with known compatibility and stability data and further summarized.
Optimizing Anti–Myelin-Associated Glycoprotein and IgM-Gammopathy Testing for Neuropathy Treatment Evaluation
ABSTRACT Objective Bacterial biofilm control around dental implants is critical for the health of the peri‐implant soft tissue and longevity of dental implants. The patient's role in regular biofilm removal around dental implants is just as important as that of the dental hygienist. The purpose of this study is to identify the relationship between at‐home dental implant care and patients' perceptions of peri‐implant soft tissue health. Methods A 15‐item paper survey was distributed to adult patients undergoing professional dental hygiene maintenance at a specialty dental practice within a 3‐month period and had at least one dental implant. Survey items included participant demographics, patient‐reported adjunctive aids for dental implants and patient perceptions of dental implant oral hygiene practices and peri‐implant soft tissue health. Results There was a statistical difference between time spent cleaning dental implants and peri‐implant soft tissue health. An association was found between patients who reported spending more time cleaning their dental implants and less bleeding ( p = 0.046/54%), gingival inflammation ( p = 0.026/58%) and gingival tissue redness ( p = 0.036/53%). Additionally, patients who more frequently underwent professional dental hygiene maintenance perceived less gingival inflammation ( p = 0.001/66%). Conclusion To promote peri‐implant soft tissue health and reduce oral biological complications, best practice guidelines should be implemented, including optimal at‐home dental implant care and regular professional dental hygiene maintenance.