Back to Authors

Willrich, Maria A

0000-0002-9318-7091

Mayo Clinic

Department of Laboratory Medicine and Pathology, Mayo Clinic, Rochester MN, United States.

Citations 22

Urine Immunoglobulin Light Chain Fragments Detected by MALDI-TOF Mass Spectrometry

Clinical Chemistry | July 17, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/clinchem/hvag085 | PMID 42467676

Reference Material Choice Affects LC-MS/MS Infliximab Quantitation

The Journal of Applied Laboratory Medicine | April 21, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1093/jalm/jfag064 | PMID 42207017

GAD65 Antibody ELISA With Extended Reportable Range: Validation and Guidance for Neurological Practice

Annals of Clinical and Translational Neurology | March 28, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/acn3.70378 | PMID 41902651

ABSTRACT Objective To (1) validate GAD65‐ELISA detection and quantification for type 1 diabetes mellitus and autoimmune neurological diagnoses, (2) correlate ELISA results (reference range < 5 IU/mL) with established radioimmunoprecipitation assay (RIA; ≤ 0.02 nmol/L), and (3) define ELISA clinical utility and pitfalls. Methods Serum performance for diabetes (FDA‐cleared, undiluted) was verified, and neurological laboratory‐developed serum and CSF dilution protocols were validated to extend the reportable range beyond > 250 IU/mL. ELISA and RIA values were correlated, including established neurological RIA cut‐offs (serum ≥ 20 nmol/L; CSF any positive). Results ELISA met analytical criteria (precision, accuracy, sensitivity, specificity, reference range) in serum and CSF and was clinically equivalent to RIA for autoimmune diabetes. Neurological ELISA cut‐offs were established at 10,000 IU/mL (serum) and 100 IU/mL (CSF). Precision was better below 10,000 IU/mL (CVs < 20%) than above (CVs 30.8% serum; 26.5% CSF). ELISA–RIA correlation and agreement was stronger below the neurological cut‐off (R 2 = 0.89) than above (R 2 = 0.36). Positive agreement for RIA‐defined neurological disease was 100% in serum and CSF; all serums were > 10,000 IU/mL. Clinical specificity was 97.5% in serum and 100% in CSF, exceeding reported RIA specificity. Screen results > 250 IU/mL spanned a wide range of dilution values; many were below the neurological cut‐off. Most patients with paired serum/CSF positivity showed elevated GAD65 IgG indices. Interpretation GAD65 ELISA and RIA have equivalent sensitivity for autoimmune diabetes and neurological testing, with higher specificity for ELISA. A serum cut‐off of 10,000 IU/mL is informative but requires clinical context, and dilution of screen > 250 IU/mL samples is essential for neurological interpretation.
A New IgG-λ Band during Therapy in Light-Chain Myeloma

The Journal of Applied Laboratory Medicine | January 9, 2026 | Volume: 11 | Issue: 4 | Pages: 961-967

10.1093/jalm/jfag004 | PMID 41808379

Commentary on Aberrant Plasma Cells in the Absence of M-Protein: Ancillary Testing beyond Protein Electrophoresis

Clinical Chemistry | October 2, 2025 | Volume: 71 | Issue: 12 | Pages: 1201-1201

10.1093/clinchem/hvaf130 | PMID 41329019

Clinical Outcomes and Treatment Strategies of Adult Transplant‐Associated Thrombotic Microangiopathy: External Validation of Harmonizing Definitions and High‐Risk Criteria

American Journal of Hematology | March 11, 2025 | Volume: 100 | Issue: 5 | Pages: 830-839

10.1002/ajh.27651 | PMID 40047384

ABSTRACTTransplant‐associated thrombotic microangiopathy (TA‐TMA) is an endothelial dysfunction syndrome observed after allogeneic hematopoietic cell transplant (alloHCT). Our aim was to externally validate the impact of high‐risk features on the clinical outcomes of adult patients meeting the updated TA‐TMA harmonizing criteria. Between 2005 and 2022, 99 patients were diagnosed with TA‐TMA at Mayo Clinic Rochester (incidence 6.2%) after a median of 137 days post alloHCT (IQR: 34–283 days). The development of TA‐TMA was associated with an inferior overall survival posttransplant (HR: 3.8, 95% CI: 2.97–4.72). High‐risk features, including concomitant infection, acute graft‐versus‐host disease (GVHD), and organ dysfunction, were associated with poor survival, while LDH elevation was not associated with inferior outcomes. The most common treatment strategy for TA‐TMA was discontinuation of calcineurin or mTOR inhibitors in 80 (81%) patients. Thirty (37.5%) patients experienced worsening of GVHD with this strategy, of which 26 (86.7%) patients had died at last follow‐up. The most common cause of death among these patients was worsening GVHD (69%; n = 18), followed by infection (11%; n = 3), disease relapse (8%; n = 2), other/unknown causes (8%; n = 2), or TA‐TMA (4%; n = 1). Objective response rate (ORR) to initial treatment for the cohort was 56.6%. Eculizumab was used in 11 patients with an observed ORR of 70%, including 5 complete responses. In conclusion, TA‐TMA remains a significant contributor to non‐relapse mortality and is associated with worse survival following alloHCT. Not all high‐risk features, particularly LDH elevation, have consistently demonstrated a negative impact in adult cohorts. Patients with TA‐TMA may benefit from immune suppression dose adjustment, rather than a discontinuation, and the addition of complement‐directed therapy, particularly among high‐risk patients.
Patient with a New Small IgG Kappa Monoclonal Protein

Clinical Chemistry | March 4, 2025 | Volume: 71 | Issue: 3 | Pages: 430-431

10.1093/clinchem/hvae152 | PMID 40037406

Applications of Mass Spectrometry Proteomic Methods to Immunoglobulins in the Clinical Laboratory

Clinical Chemistry | December 14, 2024 | Volume: 70 | Issue: 12 | Pages: 1422-1435

10.1093/clinchem/hvae179 | PMID 39667030

Abstract Background Immunoglobulin (Ig) measurements in the clinical laboratory have been traditionally performed by nephelometry, turbidimetry, electrophoresis, and ELISA assays. Mass spectrometry (MS) measurements have the potential to provide deeper insights on the nature of these markers. Content Different approaches—top-down, middle-down, or bottom-up—have been described for measuring specific Igs for endogenous monoclonal immunoglobulins (M-proteins) and exogenous therapeutic monoclonal antibody therapies (t-mAbs). Challenges arise in distinguishing the Ig of interest from the polyclonal Ig background. MS is emerging as a practical method to provide quantitative analysis and information about structural and clonal features that are not easily determined by current clinical laboratory methods. This review discusses clinically implemented examples, including isotyping and quantification of M-proteins and quantitation of t-mAbs within the polyclonal Ig background, as examples of how MS can enhance our detection and characterization of Igs. Summary This review of current clinically available MS proteomic tests for Igs highlights both analytical and nonanalytical challenges for implementation. Given the new insight into Igs from these methods, it is hoped that vendors, laboratorians, healthcare providers, and payment systems can work to overcome these challenges and advance the care of patients.
Mass Spectrometry Meets Free Light Chains: A Path toward Greater Diagnostic Precision

Clinical Chemistry | September 19, 2024 | Volume: 70 | Issue: 12 | Pages: 1395-1397

10.1093/clinchem/hvae155 | PMID 39418397

Comparison of 2 Free Light Chain Assays: Performance of the Free Light Chain Ratio as a Risk Factor for MGUS Progression

Clinical Chemistry | August 29, 2024 | Volume: 70 | Issue: 10 | Pages: 1268-1278

10.1093/clinchem/hvae124 | PMID 39206639

Abstract Background New immunoglobulin free light chain (FLC) assays are available. Despite analytical differences, it seems possible to use free light chain ratios (FLCr) generated by different assays and apply similar cut-points for the diagnosis of multiple myeloma. It is still unknown if we can use different assays for risk stratification of patients with monoclonal gammopathy of undetermined significance (MGUS). Methods Patients diagnosed with MGUS (N = 923) had FLC tested using a nephelometric FreeLite (Binding Site) assay on BNII instruments (Siemens) and a Sebia FLC assay (Sebia) on a DS2 ELISA analyzer (Dynex). Patients were followed up for progression to any plasma cell dyscrasia (PCD) for several decades. The Mayo MGUS risk stratification model for progression was assessed with both assays (M-spike &gt;1.5 g/dL; non-IgG isotype and abnormal FLCr), using package insert reference intervals (RI) and a new metric called principal component 2 (PC2). Results There were 94 events of progression to PCD in the cohort during a median of 38 years of follow-up. Freelite and Sebia FLC showed similar hazard ratios in the risk models for elevated FLCr. An alternative clinical decision point lower than the package insert RI was evaluated for the Sebia assay, which improved risk stratification for patients with a low FLCr. The PC2 metric showed similar performance to the FLCr in models, without superior benefit. Conclusions The Sebia ELISA-based FLC assay can be employed in an MGUS risk stratification model with similar performance to the original 2005 risk stratification model using the FreeLite assay.