Citations

Mayo Clinic

Clear

13 citation(s) found for "Yu, Zhicong".

Novel BCL-2 Inhibitor Lisaftoclax in Relapsed or Refractory Chronic Lymphocytic Leukemia and Other Hematologic Malignancies: First-in-Human Open-Label Trial
Ailawadhi, Sikander , Chen, Zi , Huang, Bo , Paulus, Aneel , Collins, Mary C. , Fu, Lei , Li, Mingyu , Ahmad, Mohammad , Men, Lichuang , Wang, Hengbang , Liang, Eric , Mekala, Divya J. , He, Zhicong , Lasica, Masa , Yannakou, Costas K. , Glass, Laura , Yang, Dajun , Chanan‐Khan, Asher , Fu, Lei Tommy , Davids, Matthew S , Liang, Eric , Mekala, Divya J , He, Zhicong , Lasica, Masa , Yannakou, Costas K , Parrondo, Ricardo D , Glass, Laura , Yang, Dajun , Chanan-Khan, Asher , Zhai, Yifan , Ailawadhi, Sikander , Paulus, Aneel , Davids, Matthew S.

Clinical Cancer Research | April 19, 2023 | Volume: 29 | Issue: 13 | Pages: 2385-2393

10.1158/1078-0432.ccr-22-3321 | PMID 37074726 Get It

Abstract Purpose: This global phase I trial investigated the safety, efficacy, pharmacokinetics, and pharmacodynamics of lisaftoclax (APG-2575), a novel, orally active, potent selective B-cell lymphoma 2 (BCL-2) inhibitor, in patients with relapsed or refractory chronic lymphocytic leukemia or small lymphocytic lymphoma (R/R CLL/SLL) and other hematologic malignancies (HMs). Patients and Methods: Maximum tolerated dose (MTD) and recommended phase II dose were evaluated. Outcome measures were safety and tolerability (primary) and pharmacokinetic variables and antitumor effects (secondary). Pharmacodynamics in patient tumor cells were explored. Results: Among 52 patients receiving lisaftoclax, MTD was not reached. Treatment-emergent adverse events (TEAEs) included diarrhea (48.1%), fatigue (34.6%), nausea (30.8%), anemia and thrombocytopenia (28.8% each), neutropenia (26.9%), constipation (25.0%), vomiting (23.1%), headache (21.2%), peripheral edema and hypokalemia (17.3% each), and arthralgia (15.4%). Grade ≥ 3 hematologic TEAEs included neutropenia (21.2%), thrombocytopenia (13.5%), and anemia (9.6%), none resulting in treatment discontinuation. Clinical pharmacokinetic and pharmacodynamic results demonstrated that lisaftoclax had a limited plasma residence and systemic exposure and elicited rapid clearance of malignant cells. With a median treatment of 15 (range, 6–43) cycles, 14 of 22 efficacy-evaluable patients with R/R CLL/SLL experienced partial responses, for an objective response rate of 63.6% and median time to response of 2 (range, 2–8) cycles. Conclusions: Lisaftoclax was well tolerated, with no evidence of tumor lysis syndrome. Dose-limiting toxicity was not reached at the highest dose level. Lisaftoclax has a unique pharmacokinetic profile compatible with a potentially more convenient daily (vs. weekly) dose ramp-up schedule and induced rapid clinical responses in patients with CLL/SLL, warranting continued clinical investigation.
First-in-human study of lisaftoclax (APG-2575), a novel BCL-2 inhibitor (BCL-2i), in patients (pts) with relapsed/refractory (R/R) CLL and other hematologic malignancies (HMs).
Chanan‐Khan, Asher , Huang, Bo , Konopleva, Marina , Brander, Danielle M. , Rizzieri, David A. , Lasica, Masa , Yannakou, Costas K. , Prince, H. Miles , He, Zhicong , Ahmad, Mohammad , Liang, Zhiyan , Mudenda, Boyd, Yang, Dajun , Prince, H Miles , Ailawadhi, Sikander , Chen, Zi , Tam, Constantine S. , Davids, Matthew S. , Lu, Ming‐De , Li, Mingyu , Zhai, Yifan

Journal of Clinical Oncology | June 2, 2021 | Volume: 39 | Issue: 15_suppl | Pages: 7502-7502

10.1200/jco.2021.39.15_suppl.7502 Get It

7502 Background: The BCL-2i venetoclax is active in certain HMs but can increase the risk of tumor lysis syndrome (TLS), requiring a 5-week dose ramp-up for CLL patients. Cases of severe neutropenia with venetoclax treatment have also been reported. Lisaftoclax is a novel, potent, selective BCL-2i that is active against HMs and is under clinical development. Methods: This first-in-human global phase I dose study assessed the safety, PK, PD, efficacy, and MTD/RP2D of lisaftoclax in patients with R/R CLL and other HMs. Lisaftoclax was orally administered daily in a 28-day cycle. Patients with CLL or intermediate-high TLS risk were initiated on a daily ramp-up schedule until the assigned dose before the study cycles. Results: On January 7, 2021, 35 pts had been enrolled and treated with lisaftoclax at doses ranging from 20 to 1,200 mg, with a median (range) of 2 (1-13) prior lines of treatment, and had diagnoses of R/R CLL or SLL (n = 15), MM (n = 6), FL (n = 5), WM (n = 4), and either AML, MCL, DLBCL, MDS, or HCL (n = 1 each). No DLT has been observed, even though 1,200 mg was considered as the highest dose treated. The MTD has not been reached, and no laboratory or clinical TLS has been reported. Any grade TRAEs in > 10% of pts included neutropenia (22.9%) and anemia (17.1%; hematologic), and fatigue (28.6%), diarrhea (17.1%), and nausea (11.4%; nonhematologic). Grade >3 TRAEs were neutropenia (14.3%) and thrombocytopenia, leukopenia, lymphopenia, fatigue, and nausea (2.9% of pts each). In CLL/SLL pts, grade 3-4 TRAEs included neutropenia (13.3%) and thrombocytopenia (6.7%), which did not cause treatment-related discontinuation. In all, 12 of 35 pts (34.3%) had non-treatment-related SAEs, and only two pts experienced > 1 SAE. With a median (range) treatment of 7 (3-20) cycles, 12 of 14 evaluable R/R CLL/SLL pts achieved PR, for an ORR of 85.7% and a median (range) time to response of 3 (2-7) cycles. Absolute lymphocyte counts (ALCs) were reduced at lisaftoclax doses as low as 20 mg/day. The preliminary PK profile showed that exposures increased with lisaftoclax doses from 20 to 1,200 mg (average half-life: 4-5 hours). On BH3 profiling, lisaftoclax rapidly triggered changes in BCL-2 complex in CLL/SLL pt samples, which were consistent with rapid clinical reductions in ALCs. Conclusions: Lisaftoclax was well tolerated up to 1,200 mg/day. No TLS was observed, even with the daily ramp-up schedule. There were no significant new or unmanageable safety findings, and the ORR in R/R CLL/SLL pts was 85.7%. Grade 3-4 TRAEs were infrequent, even at dose levels of 800 mg and above. BCL-2i lisaftoclax offers a treatment alternative for patients with R/R CLL/SLL and other HMs, with a daily ramp-up schedule that may be more pt “user friendly” and a favorable preliminary safety profile. Internal study identifier APG2575-001. Clinical trial information: NCT03537482.
Low‐dose CT image and projection dataset
Moen, Taylor R., Chen, Baiyu , Holmes, David R. , Yu, Zhicong , Yu, Lifeng , Duan, Xinhui , Yu, Lifeng , Leng, Shuai , Fletcher, Joel G. , McCollough, Cynthia H.

Medical Physics | November 17, 2020 | Volume: 48 | Issue: 2 | Pages: 902-911

10.1002/mp.14594 | PMID 33202055 Get It

Purpose To describe a large, publicly available dataset comprising computed tomography (CT) projection data from patient exams, both at routine clinical doses and simulated lower doses. Acquisition and Validation Methods The library was developed under local ethics committee approval. Projection and image data from 299 clinically performed patient CT exams were archived for three types of clinical exams: noncontrast head CT scans acquired for acute cognitive or motor deficit, low‐dose noncontrast chest scans acquired to screen high‐risk patients for pulmonary nodules, and contrast‐enhanced CT scans of the abdomen acquired to look for metastatic liver lesions. Scans were performed on CT systems from two different CT manufacturers using routine clinical protocols. Projection data were validated by reconstructing the data using several different reconstruction algorithms and through use of the data in the 2016 Low Dose CT Grand Challenge. Reduced dose projection data were simulated for each scan using a validated noise‐insertion method. Radiologists marked location and diagnosis for detected pathologies. Reference truth was obtained from the patient medical record, either from histology or subsequent imaging. Data Format and Usage Notes Projection datasets were converted into the previously developed DICOM‐CT‐PD format, which is an extended DICOM format created to store CT projections and acquisition geometry in a nonproprietary format. Image data are stored in the standard DICOM image format and clinical data in a spreadsheet. Materials are provided to help investigators use the DICOM‐CT‐PD files, including a dictionary file, data reader, and user manual. The library is publicly available from The Cancer Imaging Archive ( https://doi.org/10.7937/9npb‐2637 ). Potential Applications This CT data library will facilitate the development and validation of new CT reconstruction and/or denoising algorithms, including those associated with machine learning or artificial intelligence. The provided clinical information allows evaluation of task‐based diagnostic performance.
Overcoming calcium blooming and improving the quantification accuracy of percent area luminal stenosis by material decomposition of multi-energy computed tomography datasets
Li, Zhoubo , Halaweish, Ahmed F., Yu, Zhicong , Yu, Lifeng , Ritman, Erik L., Leng, Shuai , Halaweish, Ahmed F , Yu, Lifeng , McCollough, Cynthia H , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | October 1, 2020 | Volume: 7 | Issue: 05 | Pages: No page available

10.1117/1.jmi.7.5.053501 | PMID 33033732 Get It

Targeted Imaging of Renal Fibrosis Using Antibody-Conjugated Gold Nanoparticles in Renal Artery Stenosis
Zhu, Xiang-Yang, Zou, Xiangyu , Yu, Zhicong , Ferguson, Christopher M. , Zhou, Wei , Lerman, Lilach O. , Zhou, Wei , Mukherjee, Rahul K , McCollough, Cynthia H.

Investigative Radiology | May 4, 2018 | Volume: 53 | Issue: 10 | Pages: 623-628

10.1097/rli.0000000000000476 | PMID 29727402 Get It

Objectives The ability to determine the severity of renal fibrosis, which is involved in most chronic kidney diseases, may be beneficial for monitoring disease progression and management. The aim of this study was to assess a new method involving gold nanoparticles conjugated to an anti-collagen-I antibody (Co-I-AuNPs) as a computed tomography (CT) imaging contrast for the evaluation of renal fibrosis in situ. Materials and Methods Gold nanoparticles conjugated to an anti-collagen-I antibody were prepared using gold chloride reduction with sodium citrate and coated with polyethylene glycol (PEG), and their size was determined by electron microscopy and nanoparticle tracking analysis. Anti-collagen-I antibody was then conjugated to PEG-SH/COOH on the AuNP surface. The success of antibody conjugation was tested in vitro using collagen-coated plate and mouse stenotic kidney sections and in vivo using micro-CT and multidetector CT imaging. Results Bare AuNPs were 18.7 ± 0.6 nm and PEG-coated AuNPs were 45.3 ± 0.1 nm in size. In vitro, Co-I-AuNPs specifically bound to both a collagen-coated plate and mouse fibrotic kidneys. Furthermore, the stenotic mouse kidney showed increased Co-I-AuNPs retention compared with the contralateral kidney (59.3 ± 5.1 vs 45.1 ± 1.7 HU, P = 0.05), which correlated with its collagen deposition. Micro-CT also detected gold signals in situ in the Co-I-AuNP-injected kidney, which colocalized with histological trichrome staining. Conclusion Gold nanoparticles conjugated to an anti-collagen-I antibody are able to visualize kidney fibrosis in vitro and in situ and may be useful for nondestructive quantification of tissue fibrosis.
Spectral performance of a whole-body research photon counting detector CT: quantitative accuracy in derived image sets
Zhou, Wei , Yu, Zhicong , Halaweish, Ahmed, Krauß, Bernhard , Schmidt, Bernhard , Yu, Lifeng , Kappler, S. , McCollough, C, McCollough, Cynthia, Leng, Shuai , Halaweish, Ahmed, Yu, Lifeng , Zhou, Wei

Physics in Medicine & Biology | July 20, 2017 | Volume: 62 | Issue: 17 | Pages: 7216-7232

10.1088/1361-6560/aa8103 | PMID 28726669 Get It

Abstract Photon-counting computed tomography (PCCT) uses a photon counting detector to count individual photons and allocate them to specific energy bins by comparing photon energy to preset thresholds. This enables simultaneous multi-energy CT with a single source and detector. Phantom studies were performed to assess the spectral performance of a research PCCT scanner by assessing the accuracy of derived images sets. Specifically, we assessed the accuracy of iodine quantification in iodine map images and of CT number accuracy in virtual monoenergetic images (VMI). Vials containing iodine with five known concentrations were scanned on the PCCT scanner after being placed in phantoms representing the attenuation of different size patients. For comparison, the same vials and phantoms were also scanned on 2nd and 3rd generation dual-source, dual-energy scanners. After material decomposition, iodine maps were generated, from which iodine concentration was measured for each vial and phantom size and compared with the known concentration. Additionally, VMIs were generated and CT number accuracy was compared to the reference standard, which was calculated based on known iodine concentration and attenuation coefficients at each keV obtained from the U.S. National Institute of Standards and Technology (NIST). Results showed accurate iodine quantification (root mean square error of 0.5 mgI/cc) and accurate CT number of VMIs (percentage error of 8.9%) using the PCCT scanner. The overall performance of the PCCT scanner, in terms of iodine quantification and VMI CT number accuracy, was comparable to that of EID-based dual-source, dual-energy scanners.
Estimation of signal and noise for a whole-body research photon-counting CT system
Li, Zhoubo , Yu, Zhicong , Kappler, S. , Leng, Shuai , McCollough, Cynthia H. , McCollough, Cynthia H , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | June 22, 2017 | Volume: 4 | Issue: 2 | Pages: 023505

10.1117/1.jmi.4.2.023505 | PMID 28653013 Get It

Dose-efficient ultrahigh-resolution scan mode using a photon counting detector computed tomography system
Yu, Zhicong , Halaweish, Ahmed F., Kappler, S. , Hähn, Katharina, Henning, André , Li, Zhoubo , Lane, John I. , Levin, David L. , Jorgensen, Steven M., Ritman, Erik L., Lane, John , Jorgensen, Steven, Ritman, Erik, McCollough, Cynthia, Leng, Shuai , McCollough, Cynthia H. , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | December 22, 2016 | Volume: 3 | Issue: 4 | Pages: 043504

10.1117/1.jmi.3.4.043504 | PMID 28042589 Get It

Noise performance of low-dose CT: comparison between an energy integrating detector and a photon counting detector using a whole-body research photon counting CT scanner
Yu, Zhicong , Kappler, S. , Hähn, Katharina, Li, Zhoubo , Halaweish, Ahmed F., Henning, André , Leng, Shuai , McCollough, Cynthia H. , McCollough, Cynthia H , Leng, Shuai , Kappler, Steffen

Journal of Medical Imaging | December 14, 2016 | Volume: 3 | Issue: 4 | Pages: 043503

10.1117/1.jmi.3.4.043503 | PMID 28018936 Get It

Spectral prior image constrained compressed sensing (spectral PICCS) for photon-counting computed tomography
Yu, Zhicong , Li, Zhoubo , Leng, Shuai , McCollough, Cynthia H.

Physics in Medicine & Biology | August 23, 2016 | Volume: 61 | Issue: 18 | Pages: 6707-6732

10.1088/0031-9155/61/18/6707 | PMID 27551878 Get It

Abstract Photon-counting computed tomography (PCCT) is an emerging imaging technique that enables multi-energy imaging with only a single scan acquisition. To enable multi-energy imaging, the detected photons corresponding to the full x-ray spectrum are divided into several subgroups of bin data that correspond to narrower energy windows. Consequently, noise in each energy bin increases compared to the full-spectrum data. This work proposes an iterative reconstruction algorithm for noise suppression in the narrower energy bins used in PCCT imaging. The algorithm is based on the framework of prior image constrained compressed sensing (PICCS) and is called spectral PICCS; it uses the full-spectrum image reconstructed using conventional filtered back-projection as the prior image. The spectral PICCS algorithm is implemented using a constrained optimization scheme with adaptive iterative step sizes such that only two tuning parameters are required in most cases. The algorithm was first evaluated using computer simulations, and then validated by both physical phantoms and in vivo swine studies using a research PCCT system. Results from both computer-simulation and experimental studies showed substantial image noise reduction in narrow energy bins (43–73%) without sacrificing CT number accuracy or spatial resolution.