Citations

Mayo Clinic

Clear

37 citation(s) found for "Knight, Bradley P".

Sudden Cardiac Death in Firefighters From the United States: A 16‐Year Postmortem Analysis
Petek, Bradley J , Layman, Andrew J. , Weller, Samantha L , Churchill, Timothy W , Shapiro, Michael D , Bhatia, Harpreet S , Baggish, Aaron L , Harmon, Kimberly G , Drezner, Jonathan A , Maleszewski, Joseph J , Kales, Stefanos

Journal of the American Heart Association | October 30, 2026 | Volume: 15 | Issue: 21 | Pages: No page available

10.1161/jaha.126.051295 | PMID 42960733 Get It

Background Sudden cardiac death (SCD) is the leading cause of duty‐related death among firefighters. Understanding postmortem cardiovascular abnormalities associated with SCD is critical to guiding fire service cardiovascular disease screening and prevention programs. Methods This study included US firefighters who had a duty‐related death over a 16‐year period (1999–2014) with available postmortem reports (autopsy/medical examiner reports). Cases were systematically reviewed to identify cases of SCD. For each SCD case, the primary etiology of SCD was adjudicated by experts in sports cardiology and cardiovascular pathology. Results Postmortem evaluations were available for 794 of 2100 (37.8%) on‐duty firefighter deaths over the study period (average age, 44±13 years; age range, 17–82 years; 4.0% women). A total of 312 of 794 (39.3%) firefighter deaths were adjudicated as SCD. A total of 255 of 312 (81.8%) SCD events were attributable to coronary artery disease/ischemic heart disease or hypertensive heart disease, which both are associated with traditional cardiovascular risk factors. The leading etiology of SCD among young firefighters (aged <40 years) was also coronary artery disease/ischemic heart disease (24/50 [48.0%]). Of firefighters who had an exertional SCD event thought to be secondary to coronary artery disease (n=97), a total of 62 of 91 (68.1%) had severe fixed coronary stenosis, while 29 of 91 (31.9%) demonstrated acute plaque rupture/thrombosis. Conclusions More than 80% of on‐duty SCD events among US firefighters are due to coronary artery disease and hypertensive heart disease that may be prevented by early disease identification and risk factor modification. Future studies should assess the efficacy of more rigorous firefighter cardiovascular disease screening and management practices.
Sports and Exercise Cardiology: A New Frontier in Cardiovascular Disease Management
Cornwell, William K. , Dineen, Elizabeth H. , Petek, Bradley J. , Shafer, Keri M. , Davenport, Eddie D , Chung, Eugene H. , Kim, Jonathan H. , Levine, Benjamin D. , Davenport, Eddie , Levine, Benjamin D , Petek, Bradley J

Circulation: Population Health and Outcomes | July 9, 2026 | Volume: 19 | Issue: 8 | Pages: No page available

10.1161/circoutcomes.126.013583 | PMID 42422937 Get It

Exercise and physical activity are recognized as essential tools to optimize fitness and longevity, improve overall health, and reduce the risk of cardiovascular disease and other major comorbidities. However, there are inherent risks associated with participation in sports and exercise, regardless of the level of competition or skill required. As such, there is a need for cardiologists to understand the unique aspects of competitive and recreational athletics, as well as sport and exercise science, as it relates to overall heart health and cardiovascular risk. In this article, we provide an overview of the essential aspects of sports and exercise cardiology. We describe the roles and responsibilities of a sports and exercise cardiologist as a member of a comprehensive team of experts who provide care of athletes at all levels of sport, emphasize the importance of risk stratification and prevention of sudden cardiac arrest, the role of exercise for maintaining and optimizing overall health in the general population, describe the growing field of sports electrophysiology and also discuss unique aspects of sports cardiology applied to environmental health and care of the tactical athlete. Knowledge gaps and directions for future clinical and research investigation are reviewed.
Highly Accelerated Real-time Cine MRI Pulse Sequence for Cardiac Implantable Electronic Devices and Arrhythmias
Bishara, Dima , Hong, KyungPyo , Davó-Jiménez, María , Collins, Jeremy D. , Topel, Çağdaş , Fan, Lexiaozi , Sarnari, Roberto, Knight, Bradley P. , Lee, Daniel , Kim, Daniel , Knight, Bradley P , Lee, Daniel C , Kim, Daniel , Collins, Jeremy

Radiology: Cardiothoracic Imaging | November 13, 2025 | Volume: 7 | Issue: 6 | Pages: No page available

10.1148/ryct.240554 | PMID 41231128 Get It

A 32-fold accelerated real-time cine MRI sequence (radial sampling) demonstrated better temporal resolution and image quality than a 16-fold sequence (Cartesian sampling) in patients with cardiac implantable electronic devices and arrhythmias.
Abstract 4362826: Use of Stress Cardiac Magnetic Resonance to Evaluate Prognosis in Patients with Cardiac Implantable Electronic Devices
Jimenez, M. , Starrett, Lane, Topel, Çağdaş , Jaamour, Dania , Gill, Nathan , Hong, KyungPyo , Knight, Bradley P. , Knight, Bradley P , Jimenez, Maria Davo, Fan, Lexiaozi , Urban, Jacqueline Bexiga , Behnoush, Amir Hossein , Collins, Jeremy D. , Patel, Amit R. , Kim, Daniel , Lee, Daniel

Circulation | November 3, 2025 | Volume: 152 | Issue: Suppl_3 | Pages: No page available

10.1161/circ.152.suppl_3.4362826 Get It

Background: The prevalence of cardiac implantable electronic devices (CIED) is increasing, with over 300,000 new implants annually in the U.S. Stress cardiac magnetic resonance (CMR) has proven as a powerful modality for myocardial characterization, enabling accurate diagnosis of different cardiac conditions. In patients without devices, CMR findings have also demonstrated prognostic value for major adverse cardiovascular events (MACE) and guide clinical decision-making. However, its use in CIED patients has historically been limited due to safety and image quality concerns. Hypothesis: We aimed to evaluate the prognostic value of CMR imaging using wideband sequences in CIED patients. Methods: CIED patients referred for clinical CMR were included prospectively and retrospectively between January 2020 and February 2025. All patients underwent a stress CMR protocol, which included cine, wideband late gadolinium enhancement (LGE), wideband T1 mapping, and wideband stress/rest perfusion imaging. Clinical follow-up is ongoing. The primary endpoint was the occurrence of MACE, defined as the composite of myocardial infarction, heart failure hospitalization, implantable cardioverter defibrillator (ICD) therapy, cardiac death, revascularization, or heart transplant. Results: A total of 89 patients were included (median age 69.0 [58.0–75.5] years; 62.9% male). Device types included pacemakers (33.7%), ICDs (48.3%), and cardiac resynchronization therapy devices (16.9%). Over a median of follow-up of 613 days [355-991], 21 patients experienced a MACE. In unadjusted models, higher left ventricular ejection fraction (LVEF) (per 5%) was significantly associated with a lower risk of MACE (odds ratio [OR] 0.80, 95% confidence interval [CI] 0.65–0.95; p=0.016), as was higher stress myocardial blood flow (MBF) (per 0.25 mL/g/min increase: OR 0.78, 95% CI 0.60–0.98; p=0.05). In contrast, greater LV myocardial mass (per 10 g) was significantly associated with a higher risk of MACE (OR 1.27, 95% CI 1.08–1.52; p = 0.006), figure 1. Conclusion: The use of wideband sequences enabled the assessment of prognostic imaging value in CIED patients. LVEF remains a strong and consistent predictor of MACE in this population and LV mass was significantly associated with higher rates of MACE reflecting the influence of underlying cardiomyopathy. While stress perfusion CMR imaging showed promising trends, further studies with longer follow-up are needed to clarify its prognostic value in this population.
Postmortem Evaluation of Young Competitive Athletes After Sudden Cardiac Death: Time to Shock the System?
Petek, Bradley J. , Maleszewski, Joseph J. , Harmon, Kimberly G. , Harmon, Kimberly G , Petek, Bradley J

Circulation | October 13, 2025 | Volume: 152 | Issue: 15 | Pages: 1041-1043

10.1161/circulationaha.125.075597 | PMID 41082593 Get It

Sudden Cardiac Arrest and Death Secondary to Congenital Coronary Artery Abnormalities in Young Competitive Athletes
Petek, Bradley J. , Churchill, Timothy W. , Moulson, Nathaniel , Baggish, Aaron L. , Kliethermes‌, Stephanie , Maleszewski, Joseph J. , Delong, Randi , Kucera, Kristen L. , Harmon, Kimberly G. , Drezner, Jonathan A. , Kliethermes, Stephanie A , Harmon, Kimberly G , Drezner, Jonathan A , Churchill, Timothy W , Baggish, Aaron L , Petek, Bradley J

Circulation | September 29, 2025 | Volume: 152 | Issue: 13 | Pages: 971-973

10.1161/circulationaha.125.074330 | PMID 41021664 Get It

Sudden cardiac death secondary to acute aortic syndromes in young athletes in the United States
Petek, Bradley J. , Moulson, Nathaniel , Kliethermes‌, Stephanie , Maleszewski, Joseph J. , Drezner, Jonathan A. , Churchill, Timothy W. , Drezner, Jonathan A , Churchill, Timothy W , Kliethermes, Stephanie A , Baggish, Aaron L. , Delong, Randi , Kucera, Kristen L. , Harmon, Kimberly G. , Petek, Bradley J

European Journal of Preventive Cardiology | July 30, 2025 | Volume: 33 | Issue: 8 | Pages: 1499-1501

10.1093/eurjpc/zwaf472 | PMID 40737489 Get It

Multicenter Experience With a Novel Real‐Time 3‐Dimensional Intracardiac Echocardiography Catheter to Guide Interventional Cardiac Procedures
Alkhouli, Mohamad , Carroll, John D. , Desai, Aken , Gao, Yu‐Rong , Xiong, Tomnema, Natale, Andrea , Inglessis‐Azuaje, Ignacio , Knight, Bradley P. , Alkhouli, Mohamad , Desai, Aken A , Knight, Bradley P , Natale, Andrea , Xiong, Tomnema

Journal of the American Heart Association | March 13, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1161/jaha.124.037019 | PMID 40079298 Get It

Background Recent technologies enable real‐time 3‐dimensional intracardiac echocardiography (ICE) with the advantages of 2‐dimensional ICE and imaging capabilities of transesophageal echocardiography. The purpose of this study is to evaluate the real‐world, multicenter safety and performance of a novel 3‐dimensional ICE system in a variety of cardiac interventions used in standard clinical practice. Methods This prospective, multicenter, observational, single‐arm study enrolled patients who were scheduled for an invasive cardiac procedure involving guidance with ICE and followed until discharge or ≤48 hours postprocedure. Intracardiac imaging was performed with the 3‐dimensional ICE catheter, VeriSight Pro (Philips Inc.). Fluoroscopy was used in all cases and transesophageal echocardiography was used in some cases. The primary safety end point was device‐related adverse events. The primary efficacy end point included technical success, imaging success, and clinical success. Results Between October 2021 and November 2022, 155 patients were enrolled and screened. Percutaneous interventions performed included atrial septal defect/patent foramen ovale closures, left atrial appendage occlusion, catheter ablations, and valve procedures. No adverse events were related to the device or procedure. The technical, imaging, and clinical success rates were 98.7% (95% CI, 95.4%–99.8%), 96.1% (95% CI, 91.8%–98.6%), 94.8% (95% CI, 91.8%–98.6%), respectively. Overall, the VeriSight Pro ICE image quality was assessed to be “acceptable” or greater in relation to reference image modality among 96.2% (149 of 155) of procedures. Conclusions VeriSight ICE imaging is safe and effective in the guidance of a wide variety of percutaneous cardiovascular procedures and has provided successful and high‐quality imaging of cardiac structures.
Aortic velocity measurements derived from phase‐contrast MRI are influenced by a cardiac implantable electronic device in both adult and pediatric human subjects
Yang, Huili , Aboyewa, Oluyemi , Shah, Dhaivat , Golestanirad, Laleh , Baraboo, Justin , Markl, Michael , Knight, Bradley P. , Hong, KyungPyo , Kim, Daniel , Hong, KyungPyo , Aboyewa, Oluyemi B , Shah, Dhaivat , Golestanirad, Laleh , Baraboo, Justin J , Collins, Jeremy D. , Kim, Daniel , Knight, Bradley P , Markl, Michael , Webster, Gregory , Patel, Amit R. , Lee, Daniel

Magnetic Resonance in Medicine | December 6, 2024 | Volume: 93 | Issue: 5 | Pages: 2099-2107

10.1002/mrm.30399 | PMID 39642044 Get It

AbstractPurposeOverall there is a lack of evidence on the accuracy and precision of phase‐contrast (PC) MRI in patients with cardiac implantable electronic devices (CIEDs). The purpose of this study is to determine whether aortic velocity measurements are influenced by a CIED.MethodsWe scanned 21 adult patients and 8 pediatric volunteers using clinical standard PC and real‐time PC (rt‐PC) sequences with and without a CIED generator taped on human subjects (below the left clavicle for adults and children; also on the abdomen for children) to mimic image artifacts. Peak and mean velocities above the aortic valve were calculated.ResultsThe Bland–Altman analyses on peak velocity measurements in pediatric subjects showed that both the accuracy and precision worsen as the distance between the CIED and aortic valve decreases (i.e., from abdomen to below the left clavicle). Specifically, both the bias and the coefficient of variation (CV) for both clinical PC and rt‐PC increased from the abdominal position (clinical: bias = −1.1%, CV = 4.3%; rt‐PC: bias = −0.3%, CV = 3.4%) to the clavicle position (clinical: bias = −4.0%, CV = 8.1%; rt‐PC: bias = 8.2%, CV = 7.3%). A similar trend was observed for mean velocity. The mean difference in peak and mean velocity measurements between rt‐PC with CIED (either position) and clinical standard PC with no CIED was within 7.5%. In adult patients, the mean difference between rt‐PC with CIED and clinical standard PC with CIED in peak velocity was 6.9%, and the CV was 7.9%.ConclusionThis study demonstrates that aortic velocity measurements are influenced by CIED in both adult and pediatric subjects.
Infection management in the extravascular implantable cardioverter defibrillator: experience from the EV ICD Pivotal study
Murgatroyd, Francis , Manlucu, Jaimie , Knight, Bradley P. , Leclercq, Christophe , Birgersdotter‐Green, Ulrika , Mattioni, Thomas A., Sholevar, Darius P., Hersi, Ahmad , Wiggenhorn, Christopher, Friedman, Paul A. , Knight, Bradley P , Clémenty, Nicolas , Crozier, Ian , Boersma, Lucas V.A.

European Heart Journal | October 28, 2024 | Volume: 45 | Issue: Supplement_1 | Pages: No page available

10.1093/eurheartj/ehae666.746 Get It

Abstract Background The extravascular implantable cardioverter defibrillator (EV ICD) has recently emerged as an option for guideline indicated ICD patients. Results from the EV ICD Pilot and Pivotal studies demonstrated that the device can provide safe and effective therapy through chronic follow up. Lead placement outside the vasculature has the potential to reduce systemic infections. Infection occurrence and management details from the Pivotal are reported. Purpose To report on details of infection occurrence and management from the EV ICD Pivotal study. Methods The EV ICD Pivotal study was an international, prospective, single-arm, premarket clinical study. Patients with a class I or IIa indication for a single-chamber ICD per ESC or ACC/AHA/HRS guidelines were enrolled. Results In the EV ICD Pivotal study, 316 patients had an implant attempt, (74.7% male, age 53.8±13.1 years, 82% primary prevention, LVEF of 38.9%±15.4%, and NYHA Class I [23.7%] or II/III [65.5%]), of which 15 had a system or procedure-related infection (4.7%, 9 - 737 days post-implant) through an average 16.2 months follow-up. Of these infections, 8 were classified as major complications, 3 as minor, and 4 as observations. Most (n=9) infections were addressed through medication with or without wound care (2.8% of patients) while 6 (1.9% of patients) resulted in system removal. There was a single lead-related infection addressed through system explant. However, there were no reports of mediastinitis, sepsis, or endocarditis. No system removal resulted in sequelae. Conclusions Infection rates observed in the EV ICD Pivotal study were similar to those reported in the subcutaneous implantable cardioverter defibrillator. The results from this study support that EV ICD related infections are treatable with antibiotic therapy or system removal. No system or procedure-related systemic infections such as mediastinitis, sepsis, or endocarditis have been reported in the Pivotal study.