Detection of Cardiac Boundaries in Echocardiographic Images Using a Customized Order Statistics Filter
Bëlohlávek, Marek , Greenleaf, James F.

Ultrasonic Imaging | March 2, 2013 | Volume: 19 | Issue: 2 | Pages: 127-137

10.1177/016173469701900203 | PMID 9381629 Get It

Order statistics filters are nonlinear filters that suppress impulsive and Gaussian noise while preserving edges. These features are particularly useful for cardiac boundary detection in ultrasound images. Based on these facts, we have analyzed performance of a combined ranked order statistics filter. The filter subtracts ranks of ordered highest and lowest intensity values of pixels encompassed in a filter window. The rank extent and window size selection allow adjustment of filter properties for a particular application. Increasing the rank fosters the low-pass characteristics of the filter. Increasing the window size supports noise removal but reduces anatomic selectivity. The filter highlights cardiac boundaries in clinical echocardiograms with intensity proportional to the local probability of a presence of the boundary.
Producing Deep Depth of Field and Depth-Independent Resolution in Nde with Limited Diffraction Beams
Lu, Jian-yu, Greenleaf, James F.

Ultrasonic Imaging | March 2, 2013 | Volume: 15 | Issue: 2 | Pages: 134-149

10.1177/016173469301500205 | PMID 8346611 Get It

Limited diffraction beams, such as Durnin's J 0 Bessel beam, are a class of nonspreading solutions to the isotropic/homogeneous scalar wave equation. These beams can be approximately produced with finite aperture and energy over a deep depth of field. In this paper, we report the application of a broadband J 0 Bessel beam to nondestructive evaluation (NDE) of materials. Pulse-echo images of a stainless steel block phantom were obtained with both the Jo Bessel beam and a conventional focused Gaussian beam. Results show that uniformly high resolutions were obtained with the J 0 Bessel beam over a large distance. In addition, the lateral resolution of the J 0 Bessel beam is almost independent of the speed of sound of the materials inspected. In contrast, the lateral resolution of images obtained with the conventional focused Gaussian beam changes dramatically with the distance and the focal length of the beam in water is greatly reduced by the steel block. Therefore, limited diffraction beams could be useful for nondestructive evaluation of materials of different speeds of sound. Restoration of pulse-echo images obtained with these beams could be simplified.
Modified X Waves with Improved Field Properties
Lu, J-y., Greenleaf, James F. , Song, Tai‐Kyong

Ultrasonic Imaging | March 2, 2013 | Volume: 15 | Issue: 1 | Pages: 36-47

10.1177/016173469301500104 | PMID 8328118 Get It

A method to obtain a good compromise between the depth of field and the lateral resolution of “X waves” is proposed. The original X waves are theoretically nondiffracting beams generated by a specially phased infinite transmit aperture. When generated by a finite aperture, X waves are diffracting beams but have a large depth of field, maintaining uniform lateral field profiles. The proposed modification of the wave equation solution for X waves replaces a constant parameter representing the propagation angle of ultrasound with a function of radial distance at the aperture surface, and results in modified X waves that have a larger depth of field than the original X waves. Computer simulations show that a proper choice of the modification function can produce a new beam with improved field properties compared with the original X waves, promising images with higher lateral resolution and increased contrast over a large depth of field in high frame rate medical imaging. Experimental results are presented to verify the simulation results of the proposed method.
Spectral Normalization for Ultrasonic Contrast Microbubble Detection
Chen, Shigao , McMahon, Eileen M. , Greenleaf, James F. , Bëlohlávek, Marek , Fatemi, Mostafa

Ultrasonic Imaging | March 2, 2013 | Volume: 26 | Issue: 3 | Pages: 150-162

10.1177/016173460402600302 | PMID 15754796 Get It

Ultrasonic contrast agents consisting of microbubbles are used to assess tissue perfusion. The microbubbles are highly reflective and nonlinear and thus produce harmonics that are stronger than those from tissues. However, the magnitude of harmonic signals resulting from a region with microbubbles also depends on the acoustic pressure of incident ultrasound and the attenuation of intervening tissues in the ultrasound path. Therefore, the harmonic magnitude, as used in traditional harmonic imaging, may not be a reliable indicator of the presence or absence of microbubbles, and hence, tissue perfusion. To compensate for these effects, we present two parameters defined as the ratio of the harmonic to the fundamental component ( HFR) and the ratio of the harmonic to squared fundamental ( HSFR). A simplified model is used to illustrate the usefulness of these two parameters. Experiments show that both parameters improve detection of microbubbles and that HSFR performs better than HFR.
Linear Arrays for Vibro-Acoustography: A Numerical Simulation Study
Silva, Glauber T. , Greenleaf, James F. , Fatemi, Mostafa

Ultrasonic Imaging | March 2, 2013 | Volume: 26 | Issue: 1 | Pages: 1-17

10.1177/016173460402600101 | PMID 15134390 Get It

In this work, we study linear array beamforming for vibro-acoustography systems. The goal of this research is to assess the feasibility of vibro-acoustography imaging systems based on linear arrays for clinical applications. The vibro-acoustography transducer is designed with two arrays driven by two continuous-wave or tone-burst signals at slightly different frequencies. The system beamforming is modeled in a homogeneous and lossless fluid. In this model, the point-spread function (psf) of the system is obtained as the product of the spatial impulse function of each linear array. Three linear array configurations are analyzed for vibro-acoustography systems. Simulations considering 64 elements in each array are performed. Aspects related to clinical applications of vibro-acoustography, such as system spatial resolution, sidelobes, grating lobes and image frame-rate are discussed. It is concluded that linear array transducers can produce acceptable spatial resolution for clinical applications.
Vibro-Acoustography: Quantification of Flow with Highly-Localized Low-Frequency Acoustic Force
Bëlohlávek, Marek , Kinnick, Randall R., Greenleaf, James F. , Asanuma, Toshihiko

Ultrasonic Imaging | March 2, 2013 | Volume: 23 | Issue: 4 | Pages: 249-256

10.1177/016173460102300403 | PMID 12051277 Get It

The intersection of two ultrasound beams with slightly different frequencies results in generation of a localized radiation force and stimulates emission of audio signals from targeted objects. Vibro-acoustography uses this phenomenon to probe elastic properties of objects. Vibro-acoustography of contrast microbubbles in degassed water produced quantitative flow measurements from analysis of their acoustic emission. We used a dual-beam transducer generating bursts of 40-kHz vibrations. The vibrations resulted from interference of 3.48-MHz and 3.52-MHz confocal beams intersecting at the center of a thin plastic conduit. We tested flows of 13, 48, 85, and 120 mL/min of contrast microbubbles at concentrations from 1.2 times 10 5 to 6 times 10 5 bubbles/mL. The amplitude of the acoustic emission was linear with microbubble concentrations up to a value of 3.6 times 10 5 bubbles/mL. A replenishment method for microbubble contrast and flow rate analysis was used with radiation force bursts deployed at 0.05, 0.1, 0.2, 0.5, 1, and 2-second pulsing intervals. The relation between the pulsing intervals and the peak amplitude was fitted by an exponential curve and a rate constant calculated for each tested flow rate. The rate constant values were linearly correlated with the tested flows. The vibro-acoustography method provides objective, quantitative, and highly-localized assessment of flow using contrast microbubbles.
Dependence of Ultrasonic Nonlinear Parameter B/A on Fat
Errabolu, Ravimeher L., Greenleaf, J.F., Sehgal, Chandra M.

Ultrasonic Imaging | March 2, 2013 | Volume: 9 | Issue: 3 | Pages: 180-194

10.1177/016173468700900304 | PMID 3445403 Get It

This study deals with the relationship between the magnitude of acoustic nonlinearity, sound speed of tissues and the amount of fat present in them. A two-component model, i.e., nonfat and fat, has been assumed and equations that relate the nonlinear parameter (B/A) of a medium to the properties of its components have been derived for two cases. In the first case, the density and sound speed are the same for the two components; B/A is a linear function of fat concentration. To represent this case, mixtures of egg white and yolk were studied. Even though the differences in density and sound speed of the two egg components were within 1 percent of each other, B/A showed a deviation from linearity. In the second case, i.e., when the density and sound speed of the two components are not equal, a quadratic equation has been derived using mixture laws. Livers, fats, egg mixtures, and oil data were used to represent this case. B/A increased quadratically with fat concentration. The presence of proteins on the binary aqueous/fat mixtures modified the quadratic rule.
A Method to Improve the Accuracy of Ultrasound Geometrical Measurements of Boundaries in Soft Tissue
Pryor, A.T., Goldberg, Valentin , Parker, Dennis L.

Ultrasonic Imaging | March 2, 2013 | Volume: 9 | Issue: 2 | Pages: 117-131

10.1177/016173468700900204 | PMID 3318077 Get It

The geometric distortion due to the neglect of refraction in existing ultrasound scanners is demonstrated. An iterative technique to correct for refraction errors in B-mode ultrasound, denoted Second Order Refraction Transposition (SORT), is presented. In vitro experiments were performed that confirm the calculated results.
Attenuation Estimation on Phantoms - A Stability Test
Greenleaf, J.F., He, Ping

Ultrasonic Imaging | March 2, 2013 | Volume: 8 | Issue: 1 | Pages: 1-10

10.1177/016173468600800101 | PMID 3521042 Get It

Global and local attenuation coefficient estimates were calculated using three methods: the envelope peak method, the central-frequency-downshift method, and the zero-crossing method. The results show that for each method the error of the local estimate with respect to the global estimate is increased as the sample volume is decreased. While the performances of the latter two methods are comparable, the performance of the envelope peak method is significantly superior.
Scattering of Ultrasound by Tissues
Greenleaf, James F. , Sehgal, Chandra M.

Ultrasonic Imaging | March 2, 2013 | Volume: 6 | Issue: 1 | Pages: 60-80

10.1177/016173468400600106 | PMID 6540912 Get It

Scattering of ultrasound by biological tissues (continuous-inhomogeneous media) is discussed. An analytical expression for the attenuation due to scattering (α T SC ) and backscatter coefficients (σ T ) of tissues are obtained. The results explain the variation of (α T SC ) and σ T with frequency for a number of tissues. The study also provides two statistical parameters, velocity fluctuation coefficient and correlation length, in terms of which the scattering of tissues can be defined quantitatively.