Citations

Mayo Clinic

Showing 10 of 108519 citations.

An overview of psychosocial assessment procedures in reconstructive hand transplantation
Kumnig, Martin, Jowsey‐Gregoire, Sheila G. , Moreno, Elisa, Brandacher, Gerald , Azari, Kodi, Rumpold, Gerhard , Moreno, Elisa

Transplant International | October 24, 2013 | Volume: 27 | Issue: 5 | Pages: 417-427

10.1111/tri.12220 | PMID 24164333 Get It

Stress field formation for multifrequency vibro-acoustography: A simulation study
Urban, Matthew W. , Greenleaf, James F. , Fatemi, Mostafa , Urban, Matthew W

The Journal of the Acoustical Society of America | October 24, 2013 | Volume: 118 | Issue: 3_Supplement | Pages: 2006-2006

10.1121/1.4809125 Get It

Vibro-acoustography is a method that uses the dynamic radiation force (stress) of ultrasound to locally excite an object at low frequency [Fatemi and Greenleaf, Science 280, 82]. A multifrequency vibro-acoustography method is proposed that uses a multifrequency radiation stress produced by an array transducer driven with N ultrasound frequencies. A multifrequency image at the different N(N−1)/2 frequencies is produced with one scan of the region of interest, increasing the information yield by a factor of N(N−1)/2. Image formation theory is presented for multifrequency vibro-acoustography using an annular array transducer. Simulations of the stress field were performed for a 20-element, 3.5-MHz annular array transducer. Four ultrasound frequencies produce six unique low-frequency components in the point spread function. Computer phantoms with small spheres are used to demonstrate the usefulness of multifrequency vibro-acoustography for microcalcification detection in breast imaging. The lateral and axial width of the main lobe at −6 dB is 0.68 and 6.47 mm, respectively. The lateral and axial sidelobe levels are −27.8 and −16.8 dB, respectively. The proposed method holds the potential for large gains of information with good spatial resolution and no increase in scanning time. [Work supported by Grant EB00535-03 from NIH.]
Vibro-acoustography: Recent advances and future promises
Greenleaf, James F., Fatemi, Mostafa , Alizad, Azra

The Journal of the Acoustical Society of America | October 24, 2013 | Volume: 118 | Issue: 3_Supplement | Pages: 2005-2005

10.1121/1.4785690 Get It

Vibro-acoustography is an imaging modality that uses ultrasound as the source of energy to explore objects at two ends of the spectrum. Employing two ultrasound beams at slightly different frequencies, this technique produces a highly localized radiation stress field that vibrates the object at the difference frequency. In response, the object produces a secondary acoustic field. This sound, which contains information about the dynamics of the object at the low difference frequency as well as objects characteristics at the ultrasound range, is used to produce an image of the object. This combination makes vibro-acoustography a unique tool to study biological tissues at low and high frequencies simultaneously. Utility of this method has already been demonstrated for a wide range of applications in vitro. In vivo applications of vibro-acoustography have been demonstrated in a recent study on human breast. It has been shown that this technique can produce high quality in vivo images at ultrasound intensities within the recommended FDA limits. Vibro-acoustography may also be used for imaging solids, such as metallic implants. This paper describes recent achievements in vibro-acoustography as well as possible future role of this technology in medicine. [This abstract includes materials patented by MF and JFG.]
In vivo noninvasive method for measuring local wave velocity in femoral arteries of pig
Kinnick, Randall R., Pislaru, Cristina , Greenleaf, James F. , Zhang, Xiaoming , Fatemi, Mostafa , Pislaru, Cristina

The Journal of the Acoustical Society of America | October 24, 2013 | Volume: 118 | Issue: 3_Supplement | Pages: 2005-2005

10.1121/1.4785688 Get It

We have proposed generating a bending wave in the arterial wall using ultrasound radiation force and measuring the wave velocity along the arterial wall [Zhang et al., IEEE Trans. Ultrason. Ferroelectr. Freq. Control 52, 642–652 (2005)]. Here, we report the results of in vivo studies on pigs. The pig was anesthetized, and a micromanometer tip catheter was inserted into the femoral artery to measure luminal pressure. A water bath was created on the animal’s groin to allow unimpeded access of the ultrasound beams to the femoral artery. The femoral artery was first located using a 13-MHz linear-array transducer. Then, a vibro-acoustography image was obtained to ensure precise positioning of the excitation force relative to the artery. The artery was excited by the force transducer and the resulting vibration of the arterial wall was measured by a sensing Doppler transceiver. Measured wave velocity was 3.1 m/s at 300 Hz. With this new method wave velocity over a distance of 5 mm, and therefore stiffness of arteries, can be measured locally and non-invasively. Measurement time is short in a few tens of milliseconds, which allows pressure dependence and pharmacological effect on the wall properties to be measured at different cardiac times.
Noncontact modal testing of hard-drive suspensions using ultrasound radiation force
Huber, Thomas M. , Calhoun, Daniel, Kinnick, Randall R., Greenleaf, James F. , Fatemi, Mostafa

The Journal of the Acoustical Society of America | October 24, 2013 | Volume: 118 | Issue: 3_Supplement | Pages: 1928-1928

10.1121/1.4780706 Get It

The head-gimbal assembly suspension is a cantilever-like structure that holds the heads on a hard drive. We will discuss a noncontact method for modal testing, of suspensions in air, that utilizes the radiation force at the difference frequency generated by two intersecting ultrasound beams. The resulting low-frequency excitations were measured using a scanning vibrometer. This excitation technique has been demonstrated for MEMS and other small devices. There are several unique advantages of the ultrasound radiation force relative to mechanical shakers. Since the ultrasound radiation force is noncontact, a specialized test fixture was not needed; the technique was relatively insensitive to distracting resonances of fixtures and support structures. Another advantage is broadband excitation; a 550-kHz confocal ultrasound transducer excited suspension resonance frequencies from under 1 kHz to over 50 kHz. Other advantages include the ability to selectively excite different modes. For example, the amplitude of the suspension’s 2.28-kHz transverse mode was suppressed by an order of magnitude by shifting the modulation phase between the two ultrasound beams by 90. In another test, the amplitude of the 6.01-kHz torsional mode was doubled by moving the ultrasound focus point from near the center to near the edge of the suspension.
Acoustical and noise redesign considerations when trying to increase patient privacy while ensuring comfort
Klavetter, Eric

The Journal of the Acoustical Society of America | October 24, 2013 | Volume: 118 | Issue: 3_Supplement | Pages: 1871-1871

10.1121/1.4779200 Get It

An internal assessment was undertaken to understand the flow of patients to ensure comfort and privacy during their health care experience at Mayo Clinic. A number of different prototypes, work flows, and methodologies were utilized and assessed to determine the ‘‘best experience for our patients.’’ A number of prototypes ranging from self-check in to personal pagers were assessed along with creating environments that introduced ‘‘passive distractions’’ for acoustical and noise management, which can range from fireplaces, to coffee shops to playgrounds to ‘‘tech corridors.’’ While a number of these designs are currently being piloted, the over-reaching goal is to make the patient experience ‘‘like no other’’ when receiving their care at Mayo Clinic.
Gallbladder Cancer-Associated Thrombotic Microangiopathy
Gupta, Vinay , Smeltzer, Jacob P., Gangat, Naseema , Gonsalves, Wilson I. , Singh, Preet Paul , McWilliams, Robert R.

Future Oncology | October 24, 2013 | Volume: 9 | Issue: 11 | Pages: 1711-1715

10.2217/fon.13.144 | PMID 24156330 Get It

Dermatopathology by the numbers
Gibson, Lawrence E. , Lehman, Julia S. , Lehman, Julia S

Journal of Cutaneous Pathology | October 24, 2013 | Volume: 41 | Issue: 2 | Pages: 139-140

10.1111/cup.12244 | PMID 24460881 Get It

Chronic Eosinophilic Leukemia—Not Otherwise Specified (NOS) in the Background of a Large Cell Lymphoma
Rong, He , Pardanani, Animesh , Smeltzer, Jacob P., Hanson, Curtis A. , Gonsalves, Wilson I. , Gupta, Vinay Kumar , Witzig, Thomas E.

Case Reports in Hematology | October 24, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-4

10.1155/2013/458303 | PMID 24224106 Get It

Clonal eosinophilic disorders are rare among hematological malignancies. Most eosinophilia tends to be due to secondary causes such as infections, hypersensitivity conditions, drug reactions, and connective tissue disorders. The presence of a primary clonal eosinophilic disorder such as chronic eosinophilic leukemia—not otherwise specified (NOS) in the presence of a synchronous large cell lymphoma—is rare making the diagnosis challenging. We present a case of a 51-year-old female with the aforementioned presentation and demonstrate the extensive workup performed to identify the diagnosis.
Measles Virus C Protein Impairs Production of Defective Copyback Double-Stranded Viral RNA and Activation of Protein Kinase R
Pfaller, Christian K. , Radeke, Monte J. , Cattaneo, Roberto , Samuel, Charles E. , Pfaller, Christian K

Journal of Virology | October 24, 2013 | Volume: 88 | Issue: 1 | Pages: 456-468

10.1128/jvi.02572-13 | PMID 24155404 Get It

ABSTRACT Measles virus (MV) lacking expression of C protein (C KO ) is a potent activator of the double-stranded RNA (dsRNA)-dependent protein kinase (PKR), whereas the isogenic parental virus expressing C protein is not. Here, we demonstrate that significant amounts of dsRNA accumulate during C KO mutant infection but not following parental virus infection. dsRNA accumulated during late stages of infection and localized with virus replication sites containing N and P proteins. PKR autophosphorylation and stress granule formation correlated with the timing of dsRNA appearance. Phospho-PKR localized to dsRNA-containing structures as revealed by immunofluorescence. Production of dsRNA was sensitive to cycloheximide but resistant to actinomycin D, suggesting that dsRNA is a viral product. Quantitative PCR (qPCR) analyses revealed reduced viral RNA synthesis and a steepened transcription gradient in C KO virus-infected cells compared to those in parental virus-infected cells. The observed alterations were further reflected in lower viral protein expression levels and reduced C KO virus infectious yield. RNA deep sequencing confirmed the viral RNA expression profile differences seen by qPCR between C KO mutant and parental viruses. After one subsequent passage of the C KO virus, defective interfering RNA (DI-RNA) with a duplex structure was obtained that was not seen with the parental virus. We conclude that in the absence of C protein, the amount of PKR activator RNA, including DI-RNA, is increased, thereby triggering innate immune responses leading to impaired MV growth.