Citations

Mayo Clinic

Clear

2357 citation(s) found for "K, Long".

Endoscopic ultrasound-guided gastroenterostomy for the management of gastric outlet obstruction: A large comparative study with long-term follow-up
Jaruvongvanich, Veeravich , Mahmoud, Tala , Law, Ryan , Levy, Michael J. , Marya, Neil B. , Abboud, Donna Maria , Ghazi, Rabih , Matar, Reem, Rapaka, Babusai , Buttar, Navtej , Truty, Mark J. , Aerts, Maridi , Messaoudi, Nouredin , Kunda, Rastislav , Abboud, Donna M, Abboud, Donna M , Dayyeh, Barham K. Abu , Chandrasekhara, Vinay , Storm, Andrew C. , Levy, Michael J. , Vargas, Eric J. , Marya, Neil B.

Endoscopy International Open | November 10, 2022 | Volume: 11 | Issue: 01 | Pages: E60-E66

10.1055/a-1976-2279 | PMID 36644538 Get It

Abstract Background and study aims Gastric outlet obstruction (GOO) is traditionally managed with surgical gastroenterostomy (surgical-GE) and enteral stenting (ES). Endoscopic ultrasound-guided gastroenterostomy (EUS-GE) is now a third option. Large studies assessing their relative risks and benefits with adequate follow-up are lacking. We conducted a comparative analysis of patients who underwent EUS-GE, ES, or surgical-GE for GOO. Patients and methods In this retrospective comparative cohort study, consecutive patients presenting with GOO who underwent EUS-GE, ES, or surgical-GE at two academic institutions were reviewed and independently cross-edited to ensure accurate reporting. The primary outcome was need for reintervention. Secondary outcomes were technical and clinical success, length of hospital stay (LOS), and adverse events (AEs). Results A total of 436 patients (232 EUS-GE, 131 ES, 73 surgical-GE) were included. The median duration of follow-up of the entire cohort was 185.5 days (interquartile range 55.25–454.25 days). The rate of reintervention in the EUS-GE group was lower than in the ES and surgical-GE groups (0.9 %, 12.2 %, and 13.7 %, P < 0.0001). Technical success was achieved in 98.3 %, 99.2 %, and 100 % (P = 0.58), and clinical success was achieved in 98.3 %, 91.6 %, and 90.4 % (P < 0.0001) in the EUS-GE, ES, and surgical-GE groups, respectively. The EUS-GE group had a shorter LOS (2 days vs. 3 days vs. 5 days, P < 0.0001) and a lower AE rate than the ES and surgical-GE groups (8.6 % vs. 38.9 % vs. 27.4 %, P < 0.0001). Conclusion This large cohort study demonstrates the safety and palliation durability of EUS-GE as an alternative strategy for GOO palliation in select patients.
Long-term Outcomes following Operative Management of Pediatric Scapholunate Ligament Injuries
Kampen, Robert J. van , Baltzer, Heather L. , Moran, Steven L. , van Kampen, Robert J , Fox, Paige M, Baltzer, Heather L , Fox, Paige M.

Journal of Wrist Surgery | November 9, 2022 | Volume: 12 | Issue: 01 | Pages: 056-062

10.1055/s-0042-1757779 | PMID 36644723 Get It

Abstract Background Scapholunate (SL) ligament injuries are rarely diagnosed in children. This study reports the outcomes of surgically treated SL ligament injuries in patients younger than 18 years. Methods A retrospective review was performed on 20 pediatric patients with SL ligament injuries. Records were reviewed for preoperative and postoperative radiographic data, intraoperative findings, classifications of interosseous ligament injury, and postoperative course. Results Thirteen girls and seven boys sustained SL injuries requiring operative intervention and were followed for an average of 26 months. Magnetic resonance imaging (MRI) was performed in 15 patients, which revealed an SL tear in 7 patients. Arthroscopically, SL injuries were classified as Geissler grade III in 12 patients and grade IV in 5 patients. Based on the Mayo Wrist Score, nine patients had excellent or good results, while six demonstrated fair results. The mean wrist flexion–extension arc was 109 degrees, while the mean grip strength was 82% of the unaffected side. Patients treated >1 year following injury had significantly decreased grip strength and Mayo Wrist Score. Conclusion In this study, worse results were seen in children with a protracted course prior to treatment of an SL injury. A high index of suspicion is necessary to detect an SL injury in the younger age group and should be in the differential for those with persistent dorsal wrist pain, tenderness over the dorsal SL joint, and/or positive Watson's test. MRI may assist in diagnosis but is not definitive to rule out injury. Arthroscopy is valuable to determine the extent of injury.
624 A phase I/II study evaluating the safety and efficacy of a novel long-acting interleukin-7, NT-I7, for patients with newly diagnosed high-grade gliomas after chemoradiotherapy
Butt, Omar H. , Yu, Tao , Luo, Jingquin, Abraham, Christopher , Katumba, Ruth , Yang, Se Hwan, Ansstas, George , Johanns, Tanner M. , Chheda, Milan G. , Campian, Jian , Huang, Jiayi , Zhou, Alice Y. , Lee, Byung, Rettig, Michael P.

Regular and Young Investigator Award Abstracts | November 7, 2022 | Volume: No volume available | Issue: No issue available | Pages: A656-A656

10.1136/jitc-2022-sitc2022.0624 Get It

437 Safety and efficacy of immune checkpoint inhibitors (ICI) in patients living with HIV (PLWH) and metastatic non-small cell lung cancer (NSCLC): a matched cohort study from the international CATCH-IT consortium
Zarif, Talal El , Adib, Elio , Fitzgerald, Bailey G. , Huang, Jiaming , Nonato, Taylor K., McKay, Rana R. , Lorentsen, Michael , Dittus, Christopher , Dizman, Nazlı , Emu, Brinda , Falohun, Adewunmi, Abdel‐Wahab, Noha , Bankapur, Anand, Reed, Alexandra, Kim, Chul , Arora, Aakriti, Shah, Neil P. , El‐Am, Edward , Abdallah, Wassim , Al‐Hader, Ahmad, Ghazal, Batool Abu, Drolen, Claire , Espinar, Javier Baena , Nebhan, Caroline A. , Haykal, Tarek , Morse, Michael A. , Pria, Alessia Dalla , Bower, Mark , Bakalov, Veli , Bahary, Nathan , Rajkumar, Aarthi , Shah, Vishal , Lopetegui‐Lia, Nerea , AO, Georgina Long, Genova, Carlo , Barletta, Giulia, Idossa, Damé , Lamberti, Giuseppe , Freeman, Dory , Baden, Lindsey R. , Sonpavde, Guru , Naqash, Abdul Rafeh , Shah, Vishal , Genova, Carlo , Bower, Mark , Naqash, Abdul Rafeh , Nassar, Amin H. , Mouhieddine, Tarek H. , Li, Mingjia , Mittra, Arjun , Owen, Dwight H , Dobbs, Ryan W. , Shah, Neil, Kozaily, Elie , Saeed, Anwaar , Lechner, Melissa G , Johnson, Douglas, Cortellini, Alessio , Pinato, David J. , Hall, Evan, Mangla, Ankit , Singh, Parminder , Nana, Frank Aboubakar , Dima, Danai , Funchain, Pauline , Saleem, Rabia, Woodford, Rachel , Menzies, Alexander M , Puri, Sonam , Florou, Vaia , Queirolo, Paola , Addeo, Alfredo , Bersanelli, Melissa , Xie, Wanling , Ramaswami, Ramya , Marron, Thomas , Choueiri, Toni K. , Lurain, Kathryn

Regular and Young Investigator Award Abstracts | November 7, 2022 | Volume: No volume available | Issue: No issue available | Pages: A457-A458

10.1136/jitc-2022-sitc2022.0437 Get It

High SNR rapid T1‐weighted MPRAGE using spiral imaging with long readouts and improved deblurring
Wang, Dinghui , Robison, Ryan K. , Li, Zhiqiang , Pipe, James G.

Magnetic Resonance in Medicine | November 2, 2022 | Volume: 89 | Issue: 3 | Pages: 951-963

10.1002/mrm.29492 | PMID 36321560 Get It

PurposeThe goal of this work is to present the implementation of 3D spiral high‐resolution MPRAGE and to demonstrate that SNR and scan efficiency increase with the increment of readout time.TheorySimplified signal equations for MPRAGE indicate that the T1 contrast can be kept approximately the same by a simple relationship between the flip angle and the TR. Furthermore, if T1 contrast remains the same, image SNR depends on the square root of the product of the total scan time and the readout time.MethodsMPRAGE spiral sequences were implemented with distributed spirals and spiral staircase on 3 Tesla scanners. Brain images of three volunteers were acquired with different readout times. Spiral images were processed with a joint water–fat separation and deblurring algorithm and compared to Cartesian images. Pure noise data sets were also acquired for SNR evaluation.ResultsConsistent T1 weighting can be achieved with various spiral readout lengths, and between spiral MPRAGE imaging and the traditional Cartesian MPRAGE imaging. Noise performance analysis demonstrates higher SNR efficiency of spiral MPRAGE imaging with matched T1 contrast compared to the Cartesian reference imaging.ConclusionFast, high SNR MPRAGE imaging is feasible with long readout spiral trajectories.
Impact of flexible noise control (FNC) image processing parameters on portable chest radiography
Kirby, Krystal , Ren, Liqiang , Daly, Timothy R., Tandon, Yasmeen K. , Bartholmai, Brian J. , Schueler, Beth A. , Long, Zaiyang , Kirby, Krystal M, Bartholmai, Brian J

Journal of Applied Clinical Medical Physics | November 2, 2022 | Volume: 23 | Issue: 12 | Pages: No page available

10.1002/acm2.13812 | PMID 36321326 Get It

AbstractThere is a lack of understanding in the performance of flexible noise control (FNC) processing, which is used in digital radiography on a scanner vendor and has four parameters each involving multiple options. The aim of this study was to investigate the impact of FNC on portable chest imaging. An anthropomorphic chest phantom was imaged using a clinical chest program with 85 kV and five radiation dose levels at 40″ source‐to‐image distance with software‐based scatter reduction method. All images were processed without and with FNC. Noise analysis was performed in two regions of interest (ROI) on subtracted noise‐only images, and line profiles were generated through a lung‐rib interface. In addition, noise power spectra (NPS) analysis was performed in solid water phantoms of 10 and 20 cm thicknesses, using the same acquisition program and a range of dose levels. Last, feedback on retrospectively deidentified, reprocessed, and randomized clinical images from 20 portable chest exams was gathered from two thoracic radiologists. Noise reduction performances of FNC were demonstrated, with the level depending on specific FNC parameters, dose levels, ROI placement, and phantom sizes. Higher frequency textural patterns were revealed through the NPS analysis, which varied based on FNC parameters, dose levels, and phantom sizes. Overall, the vendor default parameter FGA0.5 yielded the highest noise reduction and textural artifacts. Radiologist feedback showed consistent preference of no FNC due to the presence of textural artifacts in the FNC‐processed images. An algorithm improvement to avoid introducing artifacts would be desired.
Minocycline‐induced hyperpigmentation in a patient on long‐term Nocardia suppressive treatment
Baqal, Omar , Masson, Rajeev , Hardaway, Brian , Hardaway, Brian W, Baqal, Omar J

Transplant Infectious Disease | October 28, 2022 | Volume: 24 | Issue: 6 | Pages: No page available

10.1111/tid.13980 | PMID 36306192 Get It

Surgical Repair of Truncus Arteriosus: A Long-Term Hemodynamic Assessment
Miguel, Irene Martín de , Jain, C. Charles , Egbe, Alexander C. , Hagler, Donald J. , Connolly, Heidi M. , Miranda, William R. , Martín de Miguel, Irene

World Journal for Pediatric and Congenital Heart Surgery | October 27, 2022 | Volume: 13 | Issue: 6 | Pages: 716-722

10.1177/21501351221114779 | PMID 36300270 Get It

Background: Unrepaired truncus arteriosus (TA) carries poor prognosis due to complications of unrestricted pulmonary flow, truncal valve insufficiency, and pulmonary vascular disease. Currently, the hemodynamic profile of adults late after TA repair is unknown. We reviewed the hemodynamics, prevalence, and pathophysiology of pulmonary hypertension (PH) in this population. Methods: Eighteen adult patients with repaired TA who underwent cardiac catheterization at Mayo Clinic, MN, between 1997 and 2021 were identified. PH was defined as either precapillary (mean pulmonary artery pressure [mPAP] ≥25 mm Hg, pulmonary artery wedge pressure [PAWP] ≤15 mm Hg, and pulmonary vascular resistance [PVR] >3 Wood units), isolated postcapillary (mPAP ≥25, PAWP >15, PVR ≤3), or combined (mPAP ≥25, PAWP >15, and PVR >3). Diastolic pressure and transpulmonary gradients were used as ancillary data for classification. Results: Mean age at catheterization was 34 ± 10 years. Mean right ventricular (RV) systolic pressure was 82 ± 22.6 mm Hg, mean right and left mPAPs 28.1 ± 16.2 and 27.9 ± 11.9 mm Hg, respectively. Seven patients (41.2%) had PAWP >15 mm Hg and, among those undergoing arterial catheterization, 7 (53.8%) had a left ventricular (LV) end-diastolic pressure >15 mm Hg. PH was diagnosed in 13 patients (72.2%): 6 (33.3%) precapillary, 4 (22.2%) isolated postcapillary, and 3 (16.7%) combined. PAWP >15 mm Hg was associated with male sex ( P = .049), <moderate RV dysfunction ( P = .049), and lesser RV conduit mean systolic gradient ( P = .02). Patients with PH with precapillary component were older at catheterization ( P = .046). Conclusions: In adults with repaired TA, precapillary PH was only present in one-third of patients with mPAPs not significantly increased in most, whereas elevated PAWP and left-heart disease were common.
Association of Long-term Outcomes With Stereotactic Radiosurgery vs Whole-Brain Radiotherapy for Resected Brain Metastasis
Klamer, Brett , Brown, Paul D. , Cerhan, Jane H. , Anderson, S. Keith , Carrero, Xiomara W., Whitton, Anthony , Greenspoon, Jeffrey , Ashman, Jonathan B. , Bahary, Jean-Paul , Urbanic, James J., Barker, Fred G., Farace, Elana, Khuntia, Deepak , Buckner, Jan C. , Laack, Nadia N I, Palmer, Joshua D. , Ballman, Karla V. , Parney, Ian F. , Laack, Nadia N. , Hadjipanayis, Costas G. , Giannini, Caterina , Galanis, Evanthia , Roberge, David

JAMA Oncology | October 20, 2022 | Volume: 8 | Issue: 12 | Pages: 1809

10.1001/jamaoncol.2022.5049 | PMID 36264568 Get It

Importance Long-term outcomes of radiotherapy are important in understanding the risks and benefits of therapies for patients with brain metastases. Objective To determine how the use of postoperative whole-brain radiotherapy (WBRT) or stereotactic radiosurgery (SRS) is associated with quality of life (QOL), cognitive function, and intracranial tumor control in long-term survivors with 1 to 4 brain metastases. Design, Setting, and Participants This secondary analysis of a randomized phase 3 clinical trial included 48 institutions in the US and Canada. Adult patients with 1 resected brain metastases but limited to those with 1 to 4 brain metastasis were eligible. Unresected metastases were treated with SRS. Long-term survivors were defined as evaluable patients who lived longer than 1 year from randomization. Patients were recruited between July 2011 and December 2015, and data were first analyzed in February 2017. For the present study, intracranial tumor control, cognitive deterioration, QOL, and cognitive outcomes were measured in evaluable patients who were alive at 12 months from randomization and reanalyzed in June 2017. Interventions Stereotactic radiosurgery or WBRT. Main Outcomes and Measures Intracranial tumor control, toxic effects, cognitive deterioration, and QOL. Results Fifty-four patients (27 SRS arm, 27 WBRT arm; female to male ratio, 65% vs 35%) were included for analysis with a median follow-up of 23.8 months. Cognitive deterioration was less frequent with SRS (37%-60%) compared with WBRT (75%-91%) at all time points. More patients declined by 2 or more standard deviations (SDs) in 1 or more cognitive tests for WBRT compared with SRS at 3, 6, and 9 months (70% vs 22%, 46% vs 19%, and 50% vs 20%, respectively). A 2 SD decline in at least 2 cognitive tests was associated with worse 12-month QOL in emotional well-being, functional well-being, general, additional concerns, and total scores. Overall QOL and functional independence favored SRS alone for categorical change at all time points. Total intracranial control for SRS alone vs WBRT at 12 months was 40.7% vs 81.5% (difference, −40.7; 95% CI, −68.1% to −13.4%), respectively. Data were first analyzed in February 2017. Conclusions and Relevance The use of SRS alone compared with WBRT resulted in less cognitive deterioration among long-term survivors. The association of late cognitive deterioration with WBRT was clinically meaningful. A significant decline in cognition (2 SD) was associated with overall QOL. However, intracranial tumor control was improved with WBRT. This study provides detailed insight into cognitive function over time in this patient population. Trial Registration ClinicalTrials.gov Identifier: NCT01372774 ; ALLIANCE/CCTG: N107C/CEC.3 (Alliance for Clinical Trials in Oncology/Canadian Cancer Trials Group)
Quantifying misdiagnosis rates from cross‐calibration biases and precision errors in dual‐energy X‐ray absorptiometry of the femoral neck
Fahrenholtz, Samuel J. , Long, Jeremiah R. , Whitaker, Michael , Whitaker, Michael D, Sensakovic, William F.

Medical Physics | October 18, 2022 | Volume: 50 | Issue: 3 | Pages: 1623-1634

10.1002/mp.16057 | PMID 36258271 Get It

Abstract Background Dual‐energy X‐ray absorptiometry (DXA) is an exam that measures areal bone mineral density (aBMD) and is regularly used to diagnose and monitor osteoporosis. Except for exam quality issues such as operator error, the quantitative results of an exam are not modified by a radiologist or other physician. DXA cross‐calibration errors can shift diagnoses, conceivably leading to alternate intervention decisions and patient outcomes. Purpose After identifying and correcting a cross‐calibration bias of 3.8% in our two DXA scanners’ aBMD measurements, we investigated misdiagnosis rates for given cross‐calibration errors in a single patient cohort to determine the impact on patient care and the value of cross‐calibration quality control. Methods The studied cohort was 8012 patients of all ages and sexes with femoral neck exams that were scanned on a single DXA unit from October 1, 2018 to March 31, 2021. There were six subcohorts delineated by age and sex, three female groups and three male groups. Data reporting focused on the highest risk subcohort of 2840 females aged 65 or older. The DXA unit had no calibration changes during that time. Only one femoral neck—left or right—was randomly chosen for analysis. Patients with multiple qualifying exams within the time interval had one exam randomly chosen. The proof‐of‐principle simulation shifted the aBMD values within a range of ±10%, ±8%, ±6%, ±4%, ±3.5%, ±3%, ±2.5%, ±2%, ±1.5%, ±1%, ±0.5%, and 0 (no shift); the cross‐calibration shifts were informed by published results and institutional experience. Measurement precision was modeled by randomly sampling a Gaussian distribution characterized by the worst acceptable least significant change (LSC) of 6.9%, with 100 000 samplings for each patient. T‐scores were recalculated from the shifted aBMD values, followed by reassigned diagnoses from the World Health Organization's T‐score‐based scheme. Results The unshifted original subcohort of women aged 65 and older had 599 normal diagnoses (21.1% of the cohort), 1784 osteopenia diagnoses (62.8%), and 455 osteoporosis diagnoses (16.1%). Osteoporosis diagnosis rates were highly sensitive to aBMD shifts. At the extrema, a −10% aBMD shift led to +161% osteoporosis cases, and a +10% aBMD shift led to −64.5% osteoporosis cases. Within the more plausible ±4% aBMD error range, the osteoporosis diagnosis rate changed −10.5% per +1% aBMD shift as indicated by linear regression ( R 2 = 0.98). Except for the men aged 49 years and younger subcohort, the total cohort and five subcohorts had fit line slopes ranging between −9.7% and −12.1% with R 2 ≥ 0.98. Cross‐calibration bias had greater influence for diagnosis count rates compared to measurement precision, that is, LSC. Conclusions These results quantify the degree of misdiagnosis that can occur in a clinically relevant cohort due to cross‐calibration bias. In medical practices where patients may be scanned on more than one DXA unit, ensuring cross‐calibration quality is a critical and high‐value quality control task with direct impact on patient diagnosis and treatment course. The clinical impact and incidence of poor DXA quality control practices, and cross‐calibration in particular, should be studied further.