Citations

Mayo Clinic

Clear

560 citation(s) found for "Yu, Mei".

Hypoxia-Induced SUMOylation of E3 Ligase HAF Determines Specific Activation of HIF2 in Clear-Cell Renal Cell Carcinoma
Koh, Mei Yee , Nguyen, Vuvi, Lemos, Robert, Darnay, Bryant G., Kiriakova, Galina M., Abdelmelek, Mena, Ho, Thai H. , Monzon, Federico A. , Powis, Garth , Karam, Jose Antonio , Jonasch, Eric W. , Ho, Thai , Koh, Mei Yee

Cancer Research | November 24, 2014 | Volume: 75 | Issue: 2 | Pages: 316-329

10.1158/0008-5472.can-13-2190 | PMID 25421578 Get It

Abstract Clear-cell renal cell cancer (CRCC) is initiated typically by loss of the tumor-suppressor VHL, driving constitutive activation of hypoxia-inducible factor-1 (HIF1) and HIF2. However, whereas HIF1 has a tumor-suppressor role, HIF2 plays a distinct role in driving CRCC. In this study, we show that the HIF1α E3 ligase hypoxia-associated factor (HAF) complexes with HIF2α at DNA to promote HIF2-dependent transcription through a mechanism relying upon HAF SUMOylation. HAF SUMOylation was induced by hypoxia, whereas HAF-mediated HIF1α degradation was SUMOylation independent. HAF overexpression in mice increased CRCC growth and metastasis. Clinically, HAF overexpression was associated with poor prognosis. Taken together, our results show that HAF is a specific mediator of HIF2 activation that is critical for CRCC development and morbidity. Cancer Res; 75(2); 316–29. ©2014 AACR.
Newborn Screening for Severe Combined Immunodeficiency in 11 Screening Programs in the United States
Kwan, Antonia , Abraham, Roshini S. , Currier, Robert J. , Andruszewski, Karen, Abbott, Jordan K. , Ballow, Mark, Bartoshesky, Louis, Bonilla, Francisco A., Brokopp, Charles D., Brooks, Edward G. , Caggana, Michele, Celestin, Jocelyn, Church, Joseph A., Comeau, Anne Marie , Connelly, James A. , Cowan, Morton J. , Cunningham‐Rundles, Charlotte , Dasu, Trivikram , Dave, Nina, Morena, M. Teresa de la , Duffner, Ulrich, Fong, Chin-To, Forbes, Lisa R., Freedenberg, Debra, Gelfand, Erwin W. , Hale, Jaime E. , Hanson, I. Celine , Hay, Beverly N., Hu, Diana, Infante, Anthony J., Johnson, Daisy, Kapoor, Neena , Kay, Denise M. , Lee, Rachel , Lehman, Heather K. , Lin, Zhili, Lorey, Fred, Abdel‐Mageed, Aly, Manning, Adrienne, McGhee, Sean, Naides, Stanley J. , Orange, Jordan S. , Pai, Sung‐Yun , Porteus, Matthew H. , Rodríguez, Ray, Romberg, Neil , Routes, John M. , Ruehle, Mary, Rubenstein, Arye, Saavedra‐Matiz, Carlos A., Scott, G. E. M., Scott, Patricia M., Secord, Elizabeth , Seroogy, Christine M. , Shearer, William T. , Siegel, Subhadra , Silvers, Stacy K., Stiehm, E. Richard, Sugerman, Robert W., Sullivan, John L., Tanksley, Susan, Tierce, Millard L., Verbsky, James , Vogel, Beth , Walker, Rosalyn, Walkovich, Kelly, Walter, Jolán E. , Watson, Michael S., Weinberg, Geoffrey A. , Weiner, Leonard B. , Wood, Heather, Yates, Anne, Puck, Jennifer M. , Satter, Lisa Forbes , Brower, Amy , Baker, Mei Wang , Kohn, Donald B. , Moore, Theodore Bruce , Notarangelo, Luigi D , Walker, Rosalyn, Wasserman, Richard L. , Currier, Robert , Forbes Satter, Lisa R

JAMA | August 19, 2014 | Volume: 312 | Issue: 7 | Pages: 729

10.1001/jama.2014.9132 | PMID 25138334 Get It

Outcome and Management of Pacemaker‐Induced Superior Vena Cava Syndrome
Fu, Hai‐Xia , Huang, Xinmiao , Zhong, Li , Osborn, Michael J., Bjarnason, Haraldur , Mulpuru, Siva K. , Zhao, Xianxian , Friedman, Paul A. , Cha, Yong‐Mei , Bjarnason, Haraldur

Pacing and Clinical Electrophysiology | July 17, 2014 | Volume: 37 | Issue: 11 | Pages: 1470-1476

10.1111/pace.12455 | PMID 25040311 Get It

BackgroundWe aimed to determine the long‐term outcomes of percutaneous lead extraction and stent placement in patients with pacemaker‐induced superior vena cava (SVC) syndrome.MethodsThe study retrospectively screened patients who underwent lead extraction followed by central vein stent implantation at Mayo Clinic (Rochester, MN, USA), from January 2005 to December 2012, to identify the patients with pacemaker‐induced SVC syndrome. Demographic, clinical, and follow‐up characteristics of those patients were collected from electronic medical records.ResultsSix cases were identified. The mean (standard deviation) age was 56 (15) years (male, 67%). All patients had permanent dual‐chamber pacemakers, with a mean 11‐year history of pacemaker placement. The entire device system was explanted in five patients; one patient had a 21‐year‐old pacemaker lead that could not be removed. Eight stents were implanted in six patients: five patients had one stent, one patient had three. A new pacemaker system was reimplanted through the stented vein in five patients. Technical success was achieved in all patients, without any complication. Symptoms rapidly resolved in all patients after stent deployment. The mean follow‐up duration was 48 months (range, 10–100 months). Three patients remained symptom free. Reintervention with percutaneous balloon venoplasty was successful in three patients with symptom recurrence.ConclusionPercutaneous stent implantation after lead removal followed by reimplantation of leads is a feasible alternative therapy for pacemaker‐induced SVC syndrome, although some cases may require repeat intervention.
External Validation of a Multiplex Urinary Protein Panel for the Detection of Bladder Cancer in a Multicenter Cohort
Chen, Li-Mei, Chang, Myron, Dai, Yunfeng , Chai, Karl X., Dyrskjøt, Lars , Sänchez‐Carbayo, Marta, Szarvas, Tibor , Zwarthoff, Ellen C. , Lokeshwar, Vinata B. , Jerónimo, Cármen , Parker, Alexander S. , Ross, Shanti, Borre, Michael , Ørntoft, Torben F., Jaeger, T., Beukers, Willemien, López, Luis E., Henrique, Rui , Urquidi, Virginia, Goodison, Steve , Rosser, Charles J. , Chen, Li‐Mei , Young, Paul R.

Cancer Epidemiology, Biomarkers & Prevention | June 12, 2014 | Volume: 23 | Issue: 9 | Pages: 1804-1812

10.1158/1055-9965.epi-14-0029 | PMID 24920641 Get It

Abstract Background: Because of the faltering sensitivity and/or specificity, urine-based assays currently have a limited role in the management of patients with bladder cancer. The aim of this study was to externally validate our previously reported protein biomarker panel from multiple sites in the United States and Europe. Methods: This multicenter external validation study included a total of 320 subjects (bladder cancer = 183). The 10 biomarkers (IL8, MMP9, MMP10, SERPINA1, VEGFA, ANG, CA9, APOE, SDC1, and SERPINE1) were measured using commercial ELISA assays in an external laboratory. The diagnostic performance of the biomarker panel was assessed using receiver operator curves (ROC) and descriptive statistical values. Results: Utilizing the combination of all 10 biomarkers, the area under the ROC for the diagnostic panel was noted to be 0.847 (95% confidence interval, 0.796–0.899), outperforming any single biomarker. The multiplex assay at optimal cutoff value achieved an overall sensitivity of 0.79, specificity of 0.79, positive prediction value of 0.73, and negative prediction value of 0.84 for bladder cancer classification. Sensitivity values of the diagnostic panel for high-grade bladder cancer, low-grade bladder cancer, muscle invasive bladder cancer, and non-muscle invasive bladder cancer were 0.81, 0.90, 0.95, and 0.77, respectively. Conclusions: Urinary levels of the biomarker panel enabled discrimination of patients with bladder cancer and controls, and the levels of biomarker subsets were associated with advancing tumor grade and stage. Impact: If proven to be reliable, urinary diagnostic biomarker assays can detect bladder cancer in a timely manner such that the patient can expect improvements in overall survival and quality of life. Cancer Epidemiol Biomarkers Prev; 23(9); 1804–12. ©2014 AACR.
Outcomes of Lead Revision for Myocardial Perforation After Cardiac Implantable Electronic Device Placement
Huang, Xinmiao , Fu, Hai‐Xia , Zhong, Li , Osborn, Michael J., Asirvatham, Samuel J. , Sinak, Lawrence J., Cao, Jiang, Friedman, Paul A. , Cha, Yong‐Mei , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | May 26, 2014 | Volume: 25 | Issue: 10 | Pages: 1119-1124

10.1111/jce.12457 | PMID 24863054 Get It

Percutaneous Lead Revision for Cardiac PerforationIntroductionCardiac perforation is an infrequent but potentially life‐threatening complication associated with placement of a cardiac implantable electronic device (CIED). The objective of this study was to determine the outcomes of percutaneous lead revision in patients who had lead perforation of the myocardium after CIED placement.Methods and ResultsWe reviewed records of 1,458 patients who underwent CIED lead extraction or repositioning. Of these, 31 (2.1%) had the procedure performed for lead perforation as a complication of CIED placement. Demographic, clinical, and follow‐up characteristics of the patients were analyzed. Mean (SD) patient age was 65 (23) years. Cardiac perforation was detected within 24 hours after implantation in 9 patients, within 1 month in 17, and greater than 1 month in 5. Pericardiocentesis was performed with a pigtail drainage catheter in place before the lead revision in 17 patients (55%) who had pericardial effusion, with or without hemodynamic compromise. All culprit leads were successfully managed with percutaneous lead removal (n = 3 [10%]), new lead placement (n = 12 [38%]), or lead repositioning (n = 16 [52%]). Of the 17 patients with pericardiocentesis before the reoperation, none had tamponade develop; in contrast, 3 of the remaining 14 patients had tamponade develop and required urgent pericardiocentesis. All patients survived without requiring open chest surgery.ConclusionPercutaneous removal or repositioning of the perforating lead is feasible and appears effective. Placement of a prophylactic pericardial drain catheter may reduce the incidence of urgent pericardiocentesis during or after a procedure.
Safety and Outcomes of Magnetic Resonance Imaging in Patients with Abandoned Pacemaker and Defibrillator Leads
Higgins, John V., Gard, Joseph J., Espinosa, Raúl E. , Wood, Christopher P. , Felmlee, Joel P. , Cha, Yong‐Mei , Asirvatham, Samuel J. , Dalzell, Connie, Acker, Nancy, Watson, Robert E. , Friedman, Paul A. , Sheldon, Seth H. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | May 9, 2014 | Volume: 37 | Issue: 10 | Pages: 1284-1290

10.1111/pace.12419 | PMID 24809591 Get It

IntroductionAbandoned cardiovascular implantable electronic device (CIED) leads remain a contraindication to magnetic resonance imaging (MRI) studies, largely due to in vitro data showing endocardial heating secondary to the radiofrequency field. We tested the hypothesis that abandoned CIED leads do not pose an increased risk of clinical harm for patients undergoing MRI.MethodsThis single‐center retrospective study examined the outcomes of patients who had device generators removed before MRI, rendering the device leads abandoned. Information was gathered through chart review. Data collected included lead model, pacing threshold before MRI, anatomic region examined, threshold data after generator reimplantation, and clinical patient outcome.ResultsPatients (n = 19, 11 men and eight women) ranged in age from 19 to 85 at the time of MRI. There was a mean of 1.63 abandoned leads at the time of imaging; none of the leads were MRI conditional. Of the three implantable cardioverter defibrillator (ICD) leads, two of three were dual coil. Most (31/35) of the scans performed were of the central nervous system, including head and spinal imaging. There were no adverse events associated with MRI in any of these patients with abandoned leads within 7 days of the scan. No lead malfunctions or clinically significant change in pacing thresholds were noted with generator reimplantation.ConclusionThe use of MRI in patients with abandoned cardiac device leads appears feasible when performed under careful monitoring, with no adverse events, although the experience is small. MRI did not affect the function of leads that were subsequently reconnected to a cardiac device.
Catheter Ablation Related Mitral Valve Injury: The Importance of Early Recognition and Rescue Mitral Valve Repair
Hu, Tiffany , Ebrille, Elisa , Syed, Faisal F. , Vaidya, Vaibhav R. , Cha, Yong‐Mei , Valverde, Arturo M. , Friedman, Paul A. , Suri, Rakesh M. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 9 | Pages: 971-975

10.1111/jce.12439 | PMID 24758402 Get It

Mitral Valve Injury with Catheter AblationIntroductionAn increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation‐related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.MethodsWe searched the Mayo Clinic MV surgical database over a 19‐year period (1993–2012) and the electrophysiologic procedures database over a 23‐year period (1990–2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.ResultsIndications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left‐sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure.ConclusionCircular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.
Modulation of Dendritic Cell Differentiation and Maturation by Decoy Receptor 3
Hsu, Tsui-Ling , Chang, Yung-Chi, Chen, Siu-Ju, Chiu, Allen W., Chio, Chung‐Ching , Liu, Yong‐Jun , Chen, Lieping , Hsieh, Shie-Liang Edmond

The Journal of Immunology | April 20, 2014 | Volume: 168 | Issue: 10 | Pages: 4846-4853

10.4049/jimmunol.168.10.4846 | PMID 11994433 Get It

Abstract Decoy receptor 3 (DcR3), a soluble receptor belonging to the TNFR superfamily, is a receptor for both Fas ligand (FasL) and LIGHT. It has been demonstrated that DcR3 is up-regulated in lung and colon cancers, thus promoting tumor growth by neutralizing the cytotoxic effects of FasL and LIGHT. In this study, we found that DcR3.Fc profoundly modulated dendritic cell differentiation and maturation from CD14+ monocytes, including the up-regulation of CD86/B7.2, and the down-regulation of CD40, CD54/ICAM-1, CD80/B7.1, CD1a, and HLA-DR. Moreover, DcR3-treated dendritic cells suppressed CD4+ T cell proliferation in an allogeneic MLR and up-regulated IL-4 secretion of CD4+CD45RA+ T cells. This suggests that DcR3.Fc may act not only as a decoy receptor to FasL and LIGHT, but also as an effector molecule to skew T cell response to the Th2 phenotype.
Performance of an Automatic Arrhythmia Classification Algorithm: Comparison to the ALTITUDE Electrophysiologist Panel Adjudications
Mahajan, Deepa, Dong, Yanting , Saxon, Leslie A. , Cha, Yong‐Mei , Gilliam, F. Roosevelt, Asirvatham, Samuel J. , Cesario, David A., Jones, Paul W. , Seth, Milan, Powell, Brian D. , Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 17, 2014 | Volume: 37 | Issue: 7 | Pages: 889-899

10.1111/pace.12367 | PMID 24527748 Get It

IntroductionAdjudication of thousands of implantable cardioverter defibrillator (ICD)‐treated arrhythmia episodes is labor intensive and, as a result, is most often left undone. The objective of this study was to evaluate an automatic classification algorithm for adjudication of ICD‐treated arrhythmia episodes.MethodsThe algorithm uses a machine learning algorithm and was developed using 776 arrhythmia episodes. The algorithm was validated on 131 dual‐chamber ICD shock episodes from 127 patients adjudicated by seven electrophysiologists (EPs). Episodes were classified by panel consensus as ventricular tachycardia/ventricular fibrillation (VT/VF) or non‐VT/VF, with the resulting classifications used as the reference. Subsequently, each episode electrogram (EGM) data was randomly assigned to three EPs without the atrial lead information, and to three EPs with the atrial lead information. Those episodes were also classified by the automatic algorithm with and without atrial information. Agreement with the reference was compared between the three EPs consensus group and the algorithm.ResultsThe overall agreement with the reference was similar between three‐EP consensus and the algorithm for both with atrial EGM (94% vs 95%, P = 0.87) and without atrial EGM (90% vs 91%, P = 0.91). The odds of accurate adjudication, after adjusting for covariates, did not significantly differ between the algorithm and EP consensus (odds ratio 1.02, 95% confidence interval: 0.97–1.06).ConclusionsThis algorithm performs at a level comparable to an EP panel in the adjudication of arrhythmia episodes treated by both dual‐ and single‐chamber ICDs. This type of algorithm has the potential for automated analysis of clinical ICD episodes, and adjudication of EGMs for research studies and quality analyses.
Autologous or Reduced-Intensity Conditioning Allogeneic Hematopoietic Cell Transplantation for Chemotherapy-Sensitive Mantle-Cell Lymphoma: Analysis of Transplantation Timing and Modality
Fenske, Timothy S. , Zhang, Mei-Jie , Carreras, Jeanette, Ayala, Ernesto , Burns, Linda J. , Cashen, Amanda F. , Costa, Luciano J. , Freytes, César O. , Holmberg, Leona , Inwards, David J. , Munker, Reinhold , Rizzieri, David A. , Schouten, Harry C. , Smith, Sonali M. , Waller, Edmund K. , Wirk, Baldeep , Laport, Ginna G. , Maloney, David G. , Montoto, Silvia , Hari, Parameswaran , Holmberg, Leona , Zhang, Mei‐Jie , Gale, Robert Peter , Hamadani, Mehdi , Lazarus, Hillard M. , Maziarz, Richard Thomas , Perales, Miguel‐Angel , Waller, Edmund K , Montoto, Silvia , Costa, Luciano J , Hari, Parameswaran

Journal of Clinical Oncology | December 17, 2013 | Volume: 32 | Issue: 4 | Pages: 273-281

10.1200/jco.2013.49.2454 | PMID 24344210 Get It

PurposeTo examine the outcomes of patients with chemotherapy-sensitive mantle-cell lymphoma (MCL) following a first hematopoietic stem-cell transplantation (HCT), comparing outcomes with autologous (auto) versus reduced-intensity conditioning allogeneic (RIC allo) HCT and with transplantation applied at different times in the disease course.Patients and MethodsIn all, 519 patients who received transplantations between 1996 and 2007 and were reported to the Center for International Blood and Marrow Transplant Research were analyzed. The early transplantation cohort was defined as those patients in first partial or complete remission with no more than two lines of chemotherapy. The late transplantation cohort was defined as all the remaining patients.ResultsAuto-HCT and RIC allo-HCT resulted in similar overall survival from transplantation for both the early (at 5 years: 61% auto-HCT v 62% RIC allo-HCT; P = .951) and late cohorts (at 5 years: 44% auto-HCT v 31% RIC allo-HCT; P = .202). In both early and late transplantation cohorts, progression/relapse was lower and nonrelapse mortality was higher in the allo-HCT group. Overall survival and progression-free survival were highest in patients who underwent auto-HCT in first complete response. Multivariate analysis of survival from diagnosis identified a survival benefit favoring early HCT for both auto-HCT and RIC allo-HCT.ConclusionFor patients with chemotherapy-sensitive MCL, the optimal timing for HCT is early in the disease course. Outcomes are particularly favorable for patients undergoing auto-HCT in first complete remission. For those unable to achieve complete remission after two lines of chemotherapy or those with relapsed disease, either auto-HCT or RIC allo-HCT may be effective, although the chance for long-term remission and survival is lower.