Comparison of the Abbott RealTime Human Immunodeficiency Virus Type 1 (HIV-1) Assay to the Cobas AmpliPrep/Cobas TaqMan HIV-1 Test: Workflow, Reliability, and Direct Costs
Sloma, Cari R., Germer, Jeffrey J., Gerads, Tara M., Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | February 5, 2009 | Volume: 47 | Issue: 4 | Pages: 889-895

10.1128/jcm.02231-08 | PMID 19193837 Get It

ABSTRACT The Abbott RealTime human immunodeficiency virus type 1 (HIV-1) assay (ART) and the Cobas AmpliPrep/Cobas TaqMan HIV-1 test (CTM) are commercially available assays for quantification of HIV-1 RNA in plasma. We evaluated performance characteristics, workflow, throughput, reliability, and direct costs of these assays. Both assays yielded good correlation of quantitative results ( r = 0.95) among clinical specimens, with a mean difference of −0.34 log 10 copies/ml. Testing of healthy donor plasma specimens yielded “target not detected” results by ART, with “HIV-1 RNA detected, <40 copies/ml” results for 3.3% (3 of 90 samples) of these specimens by CTM. Both the m2000sp/m2000rt (ART) and docked CAP/CTM96 (CTM) instrument systems were capable of operating with continuous, uninterrupted workflow. When daily maintenance and cleaning were included, ART and CTM run durations (5 h 52 min and 6 h 4 min, respectively) and hands-on times (53 min and 46 min, respectively) were similar for a run batch size of 24. While ART was more flexible in terms of run batch size, CTM required fewer user interventions and consistently produced higher specimen throughput rates at 8, 16, and 24 h. Assay run failure rates were 6.3% (1 of 16 runs) and 4.2% (1 of 24 runs) for ART and CTM, respectively ( P = 1.000), with invalid specimen result rates of 1.0% (5 of 495 specimens) and 2.8% (11 of 399 specimens), respectively ( P = 0.073). Direct reagent and consumable costs for each assay were comparable (difference of <10%). In selecting an assay for implementation, laboratories should consider how various assay and instrument features might impact laboratory operation and patient care.
Plasma Load Discrepancies between the Roche Cobas Amplicor Human Immunodeficiency Virus Type 1 (HIV-1) Monitor Version 1.5 and Roche Cobas AmpliPrep/Cobas TaqMan HIV-1 Assays
Yao, Joseph D. , Germer, Jeffrey J.

Journal of Clinical Microbiology | February 5, 2008 | Volume: 46 | Issue: 2 | Pages: 834-834

10.1128/jcm.02144-07 | PMID 18252859 Get It

Glomus tumor and glomangioma of the nerve
Scheithauer, Bernd W., Spinner, Robert J. , Dyck, P. James B. , Edelman, Fredric L., Amrami, Kimberly K. , Fu, Yao‐Shi, Rodríguez, Fausto J. , Salem, A.

Journal of Neurosurgery | February 1, 2008 | Volume: 108 | Issue: 2 | Pages: 348-356

10.3171/jns/2008/108/2/0348 | PMID 18240933 Get It

✓ As a rule, normal human nerve does not contain glomus bodies. Nonetheless, rare examples of glomus tumors do arise in peripheral nerves of various sizes. Their pathobiological characteristics are poorly understood, but reported examples have been small and clinically benign. The authors identified in 1 patient each a glomus tumor and a glomangioma involving nerve. Clinical histories as well as imaging and surgical findings were reviewed. All available H & E–stained slides were examined in both cases. Immunohistochemical stains and electron microscopy, as appropriate, were also performed. The lesions were subtotally and completely resected, respectively. An uneventful postoperative recovery was noted in both patients. Glomus tumors and glomangiomas can involve major nerves on rare occasions. They seem to follow a favorable clinical course, and conservative resection can be of benefit.
Impact of the COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, Version 1.5, on Clinical Laboratory Operations
Germer, Jeffrey J., Bendel, Jordan L., Dolenc, Craig A., Nelson, Sarah R., Masters, Amanda , Gerads, Tara M., Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | July 19, 2007 | Volume: 45 | Issue: 9 | Pages: 3101-3104

10.1128/jcm.00656-07 | PMID 17634308 Get It

ABSTRACT The COBAS AmpliPrep/COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5 (CAP/CA), and the COBAS AMPLICOR HIV-1 MONITOR Test, version 1.5, were compared. CAP/CA reduced and consolidated labor while modestly increasing assay throughput without increased failure rates or direct costs, regardless of batch size and assay format.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, Mark J., Uhl, J. R., Sloan, Lynne M., Buckwalter, Seanne P., Jones, Mary F. , Vetter, Emily A., Yao, Joseph D. , Wengenack, Nancy L. , Rosenblatt, Jon E., Cockerill, F. R., Smith, T. F., Cockerill, Franklin R.

Clinical Microbiology Reviews | July 17, 2006 | Volume: 19 | Issue: 3 | Pages: 595-595

10.1128/cmr.00022-06 Get It

Quantification of Hepatitis B Virus (HBV) DNA with a TaqMan HBV Analyte-Specific Reagent following Sample Processing with the MagNA Pure LC Instrument
Germer, Jeffrey J., Qutub, Mohammed , Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | April 6, 2006 | Volume: 44 | Issue: 4 | Pages: 1490-1494

10.1128/jcm.44.4.1490-1494.2006 | PMID 16597881 Get It

ABSTRACT TaqMan hepatitis B virus (HBV) analyte-specific reagent (ASR; Roche Molecular Systems, Inc., Branchburg, NJ) is designed for the quantification of HBV DNA in serum or plasma. The performance characteristics of TaqMan HBV ASR following automated sample processing with the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, IN) were evaluated in this study. Analytical sensitivity and precision were assessed with commercially available HBV standards, while clinical serum specimens from HBsAg-seropositive patients and healthy blood donors were used to determine clinical sensitivity, specificity, and correlation with other commercially available assays. Analytical studies yielded a limit of detection of 2.4 IU/ml, with good linearity and correlation ( R 2 = 0.9958) with expected HBV DNA titers over a wide range (6.0 × 10 0 to 2.1 × 10 8 IU/ml). Clinical sensitivity and specificity of the assay combined with automated sample processing were both 100%. Comparison of TaqMan HBV ASR and VERSANT HBV DNA 3.0 assay (bDNA; Bayer HealthCare LLC, Tarrytown, NY) results among clinical specimens yielded good correlation ( R 2 = 0.9237), with a mean difference in titer of −0.213 log 10 IU/ml (95% confidence interval, −0.678 to 1.10 log 10 IU/ml). The overall test failure rate was 2.0% among 204 clinical serum specimens tested. Total time required for MP sample processing and automated postelution handling of 24 samples was 224 min, with 57 min of actual hands-on time. MP is a reliable, labor-saving platform suitable for use with TaqMan HBV ASR, providing sensitive and accurate quantification of HBV DNA levels over a range of 8 log 10 IU/ml.
Evaluation of the Invader Assay for Genotyping Hepatitis C Virus
Germer, Jeffrey J., Yung, Billy, Mitchell, P. Shawn, Yao, Joseph D. , Majewski, David , Yung, Billy

Journal of Clinical Microbiology | February 2, 2006 | Volume: 44 | Issue: 2 | Pages: 318-323

10.1128/jcm.44.2.318-323.2006 | PMID 16455877 Get It

ABSTRACT The Invader 1.0 assay (Invader HCV Genotyping Assay, version 1.0; Third Wave Technologies, Inc., Madison, WI) has been developed for the rapid differentiation of hepatitis C virus (HCV) genotypes 1 to 6 based on sequence variation within the HCV 5′ noncoding (NC) region. In the present study, we evaluated the compatibility of Invader 1.0 with the COBAS MONITOR (COBAS AMPLICOR HCV MONITOR Test, version 2.0; Roche Molecular Systems, Inc., Branchburg, NJ), COBAS AMPLICOR (COBAS AMPLICOR Hepatitis C Virus Test, version 2.0; Roche Molecular Systems, Inc.), and COBAS TaqMan (COBAS TaqMan HCV Test; Roche Molecular Systems, Inc.) assays. The minimum HCV RNA titers required for successful HCV genotyping (≥90% success rate) were 1,000 IU/ml for COBAS MONITOR, 100 IU/ml for COBAS AMPLICOR, and 10 IU/ml for COBAS TaqMan. Invader 1.0 results obtained from unpurified COBAS TaqMan amplification products of 111 retrospectively selected clinical serum specimens (genotypes 1 to 6, with virus titers ranging from 15.1 to 2.1 × 10 7 IU/ml) showed 98% concordance with results obtained from the TRUGENE HCV 5 ′ NC Genotyping Kit (Bayer HealthCare LLC, Tarrytown, NY), used in conjunction with COBAS AMPLICOR. Although the assay is sensitive, accurate, and easy to perform, additional optimization of the Invader 1.0 interpretive software (Invader Data Analysis Worksheet) may be necessary to reduce potential misidentification of HCV genotypes in low-titer specimens. In summary, Invader 1.0 is compatible with a variety of commercially available PCR-based HCV 5′ NC region amplification assays and is suitable for routine HCV genotyping in clinical laboratories.
Real-Time PCR in Clinical Microbiology: Applications for Routine Laboratory Testing
Espy, Mark J., Uhl, J. R., Sloan, Lynne M., Buckwalter, Seanne P., Jones, Mary F. , Vetter, Emily A., Yao, Joseph D. , Wengenack, Nancy L. , Rosenblatt, Jon E., Cockerill, Franklin R., Smith, Thomas F.

Clinical Microbiology Reviews | January 17, 2006 | Volume: 19 | Issue: 1 | Pages: 165-256

10.1128/cmr.19.1.165-256.2006 | PMID 16418529 Get It

SUMMARY Real-time PCR has revolutionized the way clinical microbiology laboratories diagnose many human microbial infections. This testing method combines PCR chemistry with fluorescent probe detection of amplified product in the same reaction vessel. In general, both PCR and amplified product detection are completed in an hour or less, which is considerably faster than conventional PCR detection methods. Real-time PCR assays provide sensitivity and specificity equivalent to that of conventional PCR combined with Southern blot analysis, and since amplification and detection steps are performed in the same closed vessel, the risk of releasing amplified nucleic acids into the environment is negligible. The combination of excellent sensitivity and specificity, low contamination risk, and speed has made real-time PCR technology an appealing alternative to culture- or immunoassay-based testing methods for diagnosing many infectious diseases. This review focuses on the application of real-time PCR in the clinical microbiology laboratory.
Evaluation of the COBAS TaqMan HCV Test with Automated Sample Processing Using the MagNA Pure LC Instrument
Germer, Jeffrey J., Harmsen, William S. , Mandrekar, Jayawant N. , Mitchell, P. Shawn, Yao, Joseph D.

Journal of Clinical Microbiology | January 5, 2005 | Volume: 43 | Issue: 1 | Pages: 293-298

10.1128/jcm.43.1.293-298.2005 | PMID 15634985 Get It

ABSTRACT The COBAS TaqMan HCV Test (TaqMan HCV; Roche Molecular Systems Inc., Branchburg, N.J.) for hepatitis C virus (HCV) performed on the COBAS TaqMan 48 Analyzer (Roche Molecular Systems) currently relies on a manual sample processing method. Implementation of an automated sample processing method would facilitate the clinical use of this test. In this study, we evaluated the performance characteristics of TaqMan HCV following automated sample processing by the MagNA Pure LC instrument (MP; Roche Applied Science, Indianapolis, Ind.). The analytical sensitivity of TaqMan HCV following sample processing by MP was 8.1 IU/ml (95% confidence interval, 6.1 to 15.2). The assay showed good linearity ( R 2 = 0.99) across a wide range of HCV RNA levels (25 to 5 × 10 6 IU/ml), with coefficients of variation ranging from 10% to 46%. Among 83 clinical specimens, the sensitivity and specificity of TaqMan HCV were 100% and 95%, respectively, when compared to the COBAS AMPLICOR hepatitis C virus test, version 2.0 (COBAS AMPLICOR; Roche Molecular Systems), with TaqMan HCV detecting two more HCV RNA-positive specimens than COBAS AMPLICOR. Both specimens were confirmed to be HCV RNA positive by the VERSANT HCV RNA qualitative test (Bayer HealthCare LLC, Tarrytown, N.Y.). There was also strong correlation ( R 2 = 0.95) and good agreement between the results from TaqMan HCV and the VERSANT HCV RNA 3.0 assay (bDNA) (Bayer HealthCare LLC) among a group of 93 clinical specimens. The MP is a versatile, labor-saving sample processing platform suitable for reliable performance of TaqMan HCV.
Evaluation of the TRUGENE HCV 5′NC Genotyping Kit with the New GeneLibrarian Module 3.1.2 for Genotyping of Hepatitis C Virus from Clinical Specimens
Germer, Jeffrey J., Rosser, Michael, Thompson, Amber , Mitchell, P. Shawn, Smith, Thomas F., Elagin, Slava, Yao, Joseph D. , Majewski, David

Journal of Clinical Microbiology | August 5, 2004 | Volume: 42 | Issue: 8 | Pages: 3911-3911

10.1128/jcm.42.8.3911.2004 Get It