Citations

Mayo Clinic

Clear

37 citation(s) found for "Vaidya, Vaibhav".

Response to Letters Regarding Article, “Stroke or Transient Ischemic Attack in Patients With Transvenous Pacemaker or Defibrillator and Echocardiographically Detected Patent Foramen Ovale”
Friedman, Paul A. , Noheria, Amit , Ackerman, Michael J. , Asirvatham, Samuel J. , Aakre, Christopher A. , Vaidya, Vaibhav R. , Bdeir, Sami, Slusser, Joshua P. , Hodge, David O. , DeSimone, Christopher V. , DeSimone, Daniel C. , Patel, Nikhil A. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Circulation | July 7, 2014 | Volume: 130 | Issue: 2 | Pages: No page available

10.1161/circulationaha.114.009351 | PMID 25001630 Get It

Catheter Ablation Related Mitral Valve Injury: The Importance of Early Recognition and Rescue Mitral Valve Repair
Hu, Tiffany , Ebrille, Elisa , Syed, Faisal F. , Vaidya, Vaibhav R. , Cha, Yong‐Mei , Valverde, Arturo M. , Friedman, Paul A. , Suri, Rakesh M. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 9 | Pages: 971-975

10.1111/jce.12439 | PMID 24758402 Get It

Mitral Valve Injury with Catheter AblationIntroductionAn increasing number of catheter ablations involve the mitral annular region and valve apparatus, increasing the risk of catheter interaction with the mitral valve (MV) complex. We review our experience with catheter ablation‐related MV injury resulting in severe mitral regurgitation (MR) to delineate mechanisms of injury and outcomes.MethodsWe searched the Mayo Clinic MV surgical database over a 19‐year period (1993–2012) and the electrophysiologic procedures database over a 23‐year period (1990–2013) and identified 9 patients with catheter ablation related MV injury requiring clinical intervention.ResultsIndications for ablation included atrial fibrillation (AF) [n = 4], ventricular tachycardia (VT) [n = 3], and left‐sided accessory pathways [n = 2]. In all 4 AF patients, a circular mapping catheter entrapped in the MV apparatus was responsible for severe MR. In all 3 VT patients, radiofrequency energy delivery led to direct injury to the MV apparatus. In the 2 patients with accessory pathways, both mechanisms were involved (1 per patient). Six patients required surgical intervention (5 MV repair, 1 catheter removal). One patient developed severe functional MR upon successful endovascular catheter disentanglement that improved spontaneously. Two VT patients with persistent severe postablation MR were managed nonsurgically, 1 of whom died 3 months postprocedure.ConclusionCircular mapping catheter entrapment and ablation at the mitral annulus are the most common etiologies of MV injury during catheter ablation. Close surveillance of the MV is needed during such procedures and early surgical repair is important for successful salvage if significant injury occurs.
Compatibility of Electroanatomical Mapping Systems with a Concurrent Percutaneous Axial Flow Ventricular Assist Device
Vaidya, Vaibhav R. , Madhavan, Malini , Noheria, Amit , Shahid, Mohammed , Walters, Jacob, Ladewig, Dorothy J., Mikell, Susan B. , Johnson, Susan B., Suddendorf, Scott H., Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | April 24, 2014 | Volume: 25 | Issue: 7 | Pages: 781-786

10.1111/jce.12437 | PMID 24758340 Get It

Electromagnetic Interference with Ventricular Assist DeviceBackgroundHemodynamic instability hinders activation and entrainment mapping during ventricular tachycardia ablation. The Impella 2.5 microaxial flow device (MFD; Abiomed Inc., Danvers, MA, USA) is used to prevent hemodynamic instability during electrophysiologic study. However, electromagnetic interference (EMI) generated by this device can preclude accurate electroanatomic mapping.MethodsImpella was placed in the left ventricle of 7 canines for circulatory support. Electroanatomic mapping during sinus rhythm, ventricular pacing, and ventricular fibrillation (VF) was performed using magnet‐ (CARTO3, Biosense Webster Inc., Diamond Bar, CA, USA) and impedance‐ (EnSite Velocity System/EnSite NavX, St. Jude Medical Inc., St. Paul, MN, USA) based systems. Distance from device to points with severe EMI precluding acquisition was compared to points with mild/no EMI. Two methods were used to reduce EMI: (1) titration of MFD performance, and (2) impedance‐only mapping combined with manual annotation of activation.ResultsSevere EMI did not occur during impedance‐based mapping. Severe EMI was observed using CARTO3 at 9.4% of all points attempted at maximum performance level (P8) of device. Severe EMI occurred at points closer to device (40.1 ± 16.8 mm) versus (55.5 ± 20.0 mm) for mild/no EMI, P < 0.0001. Severe EMI using CARTO3 was resolved by either (1) reduction of performance from P8 to P6 or (2) impedance‐only mapping with manual annotation.ConclusionConcurrent use of MFD caused EMI to prevent acquisition of points with magnet‐based mapping. Predictors for EMI were distance from device and performance level. Temporary reductions to P6 or impedance‐only mapping are 2 methods to resolve EMI.
Endocavitary Structures in the Outflow Tract: Anatomy and Electrophysiology of the Conus Papillary Muscles
Hai, Jo Jo , Vaidya, Vaibhav R. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | October 8, 2013 | Volume: 25 | Issue: 1 | Pages: 94-98

10.1111/jce.12291 | PMID 24102678 Get It

Ablation and Mapping of the Conus Papillary MuscleCatheter ablation is an increasingly used and successful treatment choice for right ventricular outflow tract (RVOT) arrhythmias. While the role of endocavitary structures and the regional morphology of the ventricular inflow tract and the right atrium as a cause for difficulty with successful ablation are well described, similar issues within the RVOT are not well understood. It is also not commonly appreciated that one of the papillary muscles is located within the proximal RVOT. We report 3 patients in which ventricular arrhythmia was targeted and ablated in the conus papillary muscle. The anatomic features, potential role of the fascicular conduction system, and unique challenges with mapping arrhythmia arising from this structure are discussed.
Safe Ablation Near the Coronary Ostium
Vaidya, Vaibhav R. , Asirvatham, Samuel J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | September 6, 2013 | Volume: 24 | Issue: 12 | Pages: No page available

10.1111/jce.12285 | PMID 24118424 Get It

Stroke or Transient Ischemic Attack in Patients With Transvenous Pacemaker or Defibrillator and Echocardiographically Detected Patent Foramen Ovale
Friedman, Paul A. , Noheria, Amit , Bdeir, Sami, Aakre, Christopher A. , Vaidya, Vaibhav R. , Slusser, Joshua P. , Hodge, David O. , Ackerman, Michael J. , Asirvatham, Samuel J. , DeSimone, Christopher V. , Patel, Nikhil A. , DeSimone, Daniel C. , Rabinstein, Alejandro A. , Asirvatham, Samuel J

Circulation | August 15, 2013 | Volume: 128 | Issue: 13 | Pages: 1433-1441

10.1161/circulationaha.113.003540 | PMID 23946264 Get It

Background— A patent foramen ovale (PFO) may permit arterial embolization of thrombi that accumulate on the leads of cardiac implantable electronic devices in the right-sided cardiac chambers. We sought to determine whether a PFO increases the risk of stroke/transient ischemic attack (TIA) in patients with endocardial leads. Methods and Results— We retrospectively evaluated all patients who had endocardial leads implanted between January 1, 2000, and October 25, 2010, at Mayo Clinic Rochester. Echocardiography was used to establish definite PFO and non-PFO cohorts. The primary end point of stroke/TIA consistent with a cardioembolic etiology and the secondary end point of mortality during postimplantation follow-up were compared in PFO versus non-PFO patients with the use of Cox proportional hazards models. We analyzed 6075 patients (364 with PFO) followed for a mean 4.7±3.1 years. The primary end point of stroke/TIA was met in 30/364 (8.2%) PFO versus 117/5711 (2.0%) non-PFO patients (hazard ratio, 3.49; 95% confidence interval, 2.33–5.25; P <0.0001). The association of PFO with stroke/TIA remained significant after multivariable adjustment for age, sex, history of stroke/TIA, atrial fibrillation, and baseline aspirin/warfarin use (hazard ratio, 3.30; 95% confidence interval, 2.19–4.96; P <0.0001). There was no significant difference in all-cause mortality between PFO and non-PFO patients (hazard ratio, 0.91; 95% confidence interval, 0.77–1.07; P =0.25). Conclusions— In patients with endocardial leads, the presence of a PFO on routine echocardiography is associated with a substantially increased risk of embolic stroke/TIA. This finding suggests a role of screening for PFOs in patients who require cardiac implantable electronic devices; if a PFO is detected, PFO closure, anticoagulation, or nonvascular lead placement may be considered.
Outflow Tract Ventricular Tachycardia Mapped to the Coronary Arteries: Anatomical Correlates and Management Strategies
Vaidya, Vaibhav R. , Syed, Faisal F. , Bdeir, Sami, Muñoz, Freddy Del Carpio, Packer, Douglas L. , Asirvatham, Samuel J. , Vaidya, Vaibhav, DeSimone, Christopher V. , Munoz, Freddy Del‐Carpio , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | August 2, 2013 | Volume: 24 | Issue: 12 | Pages: 1416-1422

10.1111/jce.12251 | PMID 24102848 Get It

Coronary Artery Ventricular Tachycardia. Background The coronary cusps have been well described as a successful site for ablation in patients with symptomatic outflow tract ventricular tachycardia. The earliest site of activation is rarely found at the ostia or into the main coronary arteries. The exact anatomic substrate, diagnostic characteristics, and therapeutic approaches for such instances are poorly understood. Methods We retrospectively reviewed outflow tract ventricular arrhythmia (OTVA) ablations done at Mayo Clinic Rochester from 2003 to 2011 (total VT: 414; outflow tract VT: 106). Three cases were identified where the earliest site of activation was not within the cusp but rather at or within the coronary ostia (3/414 for all VT: 0.7%; 3/106 for all OTVT: 2.8%). Results In 1 patient, the left main coronary artery (LMCA) was found to have electrograms (EGMs) recorded with bipolar mapping that preceded activation in the cusps or the left ventricular outflow tract. In 2 cases, the right coronary ostium and proximal right coronary artery recorded the earliest signals. Intracardiac echocardiographic guidance was used to successfully ablate these arrhythmias targeting the aortic route (1 patient) or the right coronary cusp (2 patients), and essentially isolated the focus of origin from the ventricular outflow tracts. Detailed mapping of surrounding structures, including the atrial appendages, the contralateral outflow tract, and the coronary venous system excluded far‐field mapping in the artery as a cause for early activation at the ostial location. Local EGM characteristics suggested an unusually lengthy supravalvar myocardial extension as the likely arrhythmogenic substrate. Ablation was successful without coronary arterial or valvular injury and without valvular or root stenosis. Conclusions Endocardial ablation isolating foci of origin in the vicinity of the coronary ostia is a challenging procedure but can be performed safely with appropriate visualization and is effective in the treatment of OTVA.