Citations

Mayo Clinic

Clear

57 citation(s) found for "Burkhardt, J".

O-065 Multicenter investigation into presentation, management and outcome of infectious intracranial aneurysms
Saad, Hassan , Newman, Sarah, Grossberg, Jonathan A , Cawley, C. Michael , Fox, C, Perez-Vaga, C, Burkhardt, Jan‐Karl , Salem, Mohamed M , Jabbour, Pascal , Starke, R, Lu, Victor M. , Levitt, M, Spiotta, Alejandro M , Alawieh, Ali , Dimisko, Laurie , Zohdy, Youssef M. , Pradilla, Gustavo , Jabbour, Pascal , Naamani, Kareem El , Schmidt, Richard F. , Gooch, Michael Reid , Abdelsalam, Ahmed , Levitt, M, Hertzberg, Vicki , Barrow, Daniel L. , Howard, Brian M

SNIS 20th annual meeting oral abstracts | July 30, 2023 | Volume: No volume available | Issue: No issue available | Pages: A51.1-A51

10.1136/jnis-2023-snis.65 Get It

Sonolucent Cranioplasty in Extracranial to Intracranial Bypass Surgery: Early Multicenter Experience of 44 Cases
Salem, Mohamed M , Ravindran, Krishnan , Hoang, Alex Nguyen , Doron, Omer , Esparza, Rogelio , Raper, Daniel , Jankowitz, Brian T. , Tanweer, Omar , Langer, David J. , Nossek, Erez , Burkhardt, Jan‐Karl , Burkhardt, Jan‐Karl , Lopes, Demetrius K.

Operative Neurosurgery | March 17, 2023 | Volume: 25 | Issue: 1 | Pages: 20-27

10.1227/ons.0000000000000674 | PMID 36929760 Get It

BACKGROUND: The new sonolucent cranioplasty implant (clear polymethyl methacrylate, PMMA) adds functionality besides surgical reconstruction. One possible application uses the transcranioplasty ultrasound (TCUS) technique after PMMA cranioplasty to assess graft patency of extracranial-intracranial (EC-IC) bypass procedures. OBJECTIVE: To report our early multicenter experience. METHODS: This is a multicenter analysis of consecutive EC-IC bypass patients from 5 US centers (2019-2022) with closure postbypass using PMMA implant. RESULTS: Forty-four patients (median age 53 years, 68.2% females) were included. The most common indication for bypass was Moyamoya disease/syndrome (77.3%), and superficial temporal artery to middle cerebral artery bypass was the most common procedure (79.5%). Pretreatment modified Rankin Scales of 0 and 1 to 2 were noted in 11.4% and 59.1% of patients, respectively. Intraoperative imaging for bypass patency involved a combination of modalities; Doppler was the most used modality (90.9%) followed by indocyanine green and catheter angiography (86.4% and 61.4%, respectively). Qualitative TCUS assessment of graft patency was feasible in all cases. Postoperative inpatient TCUS confirmation of bypass patency was recorded in 56.8% of the cases, and outpatient TCUS surveillance was recorded in 47.7%. There were no cases of bypass failure necessitating retreatment. Similarly, no implant-related complications were encountered in the cohort. Major complications requiring additional surgery occurred in 2 patients (4.6%) including epidural hematoma requiring evacuation (2.3%) and postoperative surgical site infection (2.3%) that was believed to be unrelated to the implant. CONCLUSION: This multicenter study supports safety and feasibility of using sonolucent PMMA implant in EC-IC bypass surgery with the goal of monitoring bypass patency using TCUS.
HS1 and Itk cooperate to regulate actin remodeling and Ca2+ signaling in T cells (35.28)
Carrizosa, Esteban, Gomez, Timothy S., Labno, Christine M., Chang, Briana L., Dehring, Deborah A. Klos, Zhu, Peimin, Billadeau, Daniel D. , Chang, Briana L, Freedman, Bruce D. , Burkhardt, Janis K.

The Journal of Immunology | January 1, 2023 | Volume: 182 | Issue: Supplement_1 | Pages: 35.28-35.28

10.4049/jimmunol.182.supp.35.28 Get It

Abstract Productive T cell activation requires efficient reorganization of the actin cytoskeleton. We have shown that the actin regulatory protein HS1 is required for the stabilization of F-actin and Vav1 at the immunological synapse (IS) and for efficient Ca2+ responses. The Tec family kinase Itk also regulates actin responses, in part by facilitating the localization of Vav1 at the IS, suggesting that these proteins act in the same pathway. Using video microscopy, we found that T cells lacking Itk or HS1 behaved similarly, extending unstable actin-rich protrusions upon TCR stimulation. HS1 and Itk could be coimmunoprecipitated from T cell lysates, and GST-pulldown studies showed that Itk’s SH2 domain binds directly to two phosphotyrosines in HS1. In the absence of Itk, HS1 failed to localize to the IS. Since Itk is required for PLCγ1 phosphorylation and Ca2+ store release, we examined the Ca2+ signaling pathway in HS1 knockout T cells in greater detail. T cells lacking HS1 exhibited abnormal Ca2+ store release. These cells showed normal phosphorylation but altered localization of PLCγ1. We conclude that Itk-dependent recruitment of HS1 is required for actin stabilization at the IS, and directs the localization of PLCγ1. Supported by NIH F31-AI071385 to EC and NIH R01-A1065644 to JKB
Microsurgical Obliteration of Craniocervical Junction Dural Arteriovenous Fistulas: Multicenter Experience
Salem, Mohamed M. , Srinivasan, Visish M. , Ravindran, Krishnan , Yang, Kaiyun , Karahalios, Katherine , Raygor, Kunal P. , Naylor, Ryan M. , Tavakoli, Samon , Abdelsalam, Ahmed , Chen, Stephanie H. , Jankowitz, Brian T. , Başkaya, Mustafa K. , Cherian, Jacob , Kim, Louis J. , Starke, Robert M., Kan, Peter , Dehdashti, Amir R. , Abla, Adib A. , Lawton, Michael T. , Burkhardt, Jan‐Karl , Abla, Adib , Burkhardt, Jan‐Karl , Tonetti, Daniel A. , Taussky, Philipp , Catapano, Joshua S , Grandhi, Ramesh , Mascitelli, Justin R , Gompel, Jamie J. Van , Couldwell, William T. , Kim, Louis J. , Cohen‐Gadol, Aaron

Neurosurgery | December 15, 2022 | Volume: 92 | Issue: 1 | Pages: 205-212

10.1227/neu.0000000000002196 | PMID 36519864 Get It

BACKGROUND: Dural arteriovenous fistulas (dAVFs) located at craniocervical junction are extremely rare (1%-2% of intracranial/spinal dAVFs). Their angio-architectural complexity renders endovascular embolization to be challenging given multiple small feeders with risk of embolysate reflux into vertebral artery and limited transvenous access. The available literature discussing microsurgery for these lesions is limited to few case reports. OBJECTIVE: To report a multicenter experience assessing microsurgery safety/efficacy. METHODS: Prospectively maintained registries at 13 North American centers were queried to identify craniocervical junction dAVFs treated with microsurgery (2006-2021). RESULTS: Thirty-eight patients (median age 59.5 years, 44.7% female patients) were included. The most common presentation was subarachnoid/intracranial hemorrhage (47.4%) and myelopathy (36.8%) (92.1% of lesions Cognard type III-V). Direct meningeal branches from V3/4 vertebral artery segments supplied 84.2% of lesions. All lesions failed (n = 5, 13.2%) or were deemed inaccessible/unsafe to endovascular treatment. Far lateral craniotomy was the most used approach (94.7%). Intraoperative angiogram was performed in 39.5% of the cases, with angiographic cure in 94.7% of cases (median imaging follow-up of 9.2 months) and retreatment rate of 5.3%. Favorable last follow-up modified Rankin Scale of 0 to 2 was recorded in 81.6% of the patients with procedural complications of 2.6%. CONCLUSION: Craniocervical dAVFs represent rare entity of lesions presenting most commonly with hemorrhage or myelopathy because of venous congestion. Microsurgery using a far lateral approach provides robust exposure and visualization for these lesions and allows obliteration of the arterialized draining vein intradurally as close as possible to the fistula point. This approach was associated with a high rate of angiographic cure and favorable clinical outcomes.
Intrasaccular flow disruption for ruptured aneurysms: an international multicenter study
Diestro, Jose Danilo Bengzon , Dibas, Mahmoud , Adeeb, Nimer , Regenhardt, Robert W. , Vranic, Justin E. , Guenego, Adrien , Lay, Sovann V. , Balushi, Ali Al , Shotar, Eimad , Premat, Kévin , Möhlenbruch, Markus , Foreman, Paul M. , Vachhani, Jay A. , Župančić, Vedran , Hafeez, Muhammad Ubaid , Rai, Hamid, Tutino, Vincent M. , Mirshani, Shervin, Ghozy, Sherief , Alotaibi, Naif M. , Rabinov, James D. , Ren, Yifan , Goren, Oded , Piano, Mariangela , Michelozzi, Caterina , Elens, Stéphanie , Starke, Robert M. , Nguyên, Anh , Jones, Jesse , Psychogios, Marios, Spears, Julian , Bullrich, María Bres , Mayich, Michael , Salem, Mohamed M. , Burkhardt, Jan‐Karl , Jankowitz, Brian T. , Ulfert, Christian , Lubicz, Boris , Puri, Ajit S , Pero, Guglielmo , Asadi, Hamed , Siddiqui, Adnan H. , Ducruet, Andrew F. , Albuquerque, Felipe C , Kan, Peter , Kalousek, Vladimir , Lylyk, Pedro , Boddu, Srikanth , Stapleton, Christopher J. , Knopman, Jared , Jabbour, Pascal , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Aziz‐Sultan, Mohammad Ali , Patel, Aman B. , Dmytriw, Adam A. , Shotar, Eimad , Saliou, Guillaume , Lylyk, Ivan , Vachhani, Jay A , Rai, Hamid , Tutino, Vincent M , Harker, Pablo , Ren, Yifan , Schirmer, Clemens M , Michelozzi, Caterina , Elens, Stephanie , Hassan, Ameer E , Nguyen, Anh , Jones, Jesse , Parra-Fariñas, Carmen , Salem, Mohamed M , Domingo, Ricardo A , Tawk, Rabih, Pero, Guglielmo , Albuquerque, Felipe C , Kan, Peter , Kalousek, Vladimir , Jabbour, Pascal , Tjoumakaris, Stavropoula , Clarençon, Frédéric , Cuellar-Saenz, Hugo H , Dmytriw, Adam A , Siddiqui, Adnan H , Dibas, Mahmoud , Ghozy, Sherief , Diestro, Jose Danilo B , Regenhardt, Robert W , Hafeez, Muhammad U , Ulfert, Christian , Lay, Sovann V , Burkhardt, Jan‐Karl , Renieri, Leonardo , Naamani, Kareem El , Saliou, Guillaume , Lylyk, Iván , Rutledge, Caleb , Harker, Pablo , Schirmer, Clemens M. , Kühn, Anna Luisa , Hassan, Ameer E , Salehani, Arsalaan , Psychogios, Marios‐Nikos , Domingo, Ricardo A. , Huynh, Thien , Tawk, Rabih G. , Panni, Pietro , Griessenauer, Christoph J. , Du, Rose , Jabbour, Pascal , Limbucci, Nicola , Cuellar, Hugo , Cognard, Christophe

Journal of NeuroInterventional Surgery | July 22, 2022 | Volume: 15 | Issue: 9 | Pages: 844-850

10.1136/jnis-2022-019153 | PMID 35868856 Get It

Background The Woven EndoBridge (WEB) device is a novel intrasaccular flow disruptor tailored for bifurcation aneurysms. We aim to describe the degree of aneurysm occlusion at the latest follow-up, and the rate of complications of aneurysms treated with the WEB device stratified according to rupture status. Methods Our data were taken from the WorldWideWeb Consortium, an international multicenter cohort including patients treated with the WEB device. Aneurysms were classified into two groups: ruptured and unruptured. We compared clinical and radiologic outcomes of both groups. Propensity score matching (PSM) was done to match according to age, gender, bifurcation, location, prior treatment, neck, height, dome width, daughter sac, incorporated branch, pretreatment antiplatelets, and last imaging follow-up. Results The study included 676 patients with 691 intracranial aneurysms (529 unruptured and 162 ruptured) treated with the WEB device. The PSM analysis had 55 pairs. In both the unmatched (85.8% vs 84.3%, p=0.692) and matched (94.4% vs 83.3%, p=0.066) cohorts there was no significant difference in the adequate occlusion rate at the last follow-up. Likewise, there were no significant differences in both ischemic and hemorrhagic complications between the two groups. There was no documented aneurysm rebleeding after WEB device implantation. Conclusion There was no significant difference in both the radiologic outcomes and complications between unruptured and ruptured aneurysms. Our findings support the feasibility of treatment of ruptured aneurysms with the WEB device.
Cover Image, Volume 32, Issue 11
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , Knight, Bradley P , Tzou, Wendy , Schaller, Robert D. , McLeod, Christopher J. , Natale, Andrea

Journal of Cardiovascular Electrophysiology | November 6, 2021 | Volume: 32 | Issue: 11 | Pages: No page available

10.1111/jce.15283 Get It

Evaluation of a novel cardiac signal processing system for electrophysiology procedures: The PURE EP 2.0 study
Al‐Ahmad, Amin , Knight, Bradley P. , Tzou, Wendy S. , Yasin, Omar , Padmanabhan, Deepak , Zagrodzky, Jason , Bassiouny, Mohammed, Burkhardt, J. David , Gallinghouse, G. Joseph , Mansour, Moussa , McLeod, Christopher , Natale, Andrea , Knight, Bradley P , Tzou, Wendy , Yasin, Omar , Padmanabhan, Deepak , Natale, Andrea , Schaller, Robert D. , McLeod, Christopher

Journal of Cardiovascular Electrophysiology | September 23, 2021 | Volume: 32 | Issue: 11 | Pages: 2915-2922

10.1111/jce.15250 | PMID 34554634 Get It

AbstractBackgroundIntracardiac electrogram data remain one of the primary diagnostic inputs guiding complex ablation procedures. However, the technology to collect, process, and display intracardiac signals has known shortcomings and has not advanced in several decades.ObjectiveThe purpose of this study was to evaluate a new signal processing platform, the PURE EP™ system (PURE), in a multi‐center, prospective study.MethodsIntracardiac signal data of clinical interest were collected from 51 patients undergoing ablation procedures with PURE, the signal recording system, and the 3D mapping system at the same time stamps. The samples were randomized and subjected to blinded, controlled evaluation by three independent electrophysiologists to determine the overall quality and clinical utility of PURE signals when compared to conventional sources. Each reviewer assessed the same (92) signal sample sets and responded to (235) questions using a 10‐point rating scale. If two or more reviewers rated the PURE signal higher than the control, it was deemed superior.ResultsA total of 93% of question responses showed consensus amongst the blinded reviewers. Based on the ratings for each pair of signals, a cumulative total of 164 PURE signals out of 218 (75.2%) were statistically rated as Superior for this data set (p < .001). Only 14 PURE signals out of 218 were rated as Inferior (6.4%).ConclusionThe PURE intracardiac signals were statistically rated as superior when compared to conventional systems.
Flow Diversion for Middle Cerebral Artery Aneurysms: An International Cohort Study
Diestro, Jose Danilo Bengzon , Adeeb, Nimer , Dibas, Mahmoud , Boisseau, William , Harker, Pablo , Brinjikji, Waleed , Xiang, Sishi, Joyce, Evan, Shapiro, Maksim , Raz, Eytan , Pickett, Gwynedd E. , Alotaibi, Naif M. , Regenhardt, Robert W. , Spears, Julian , Burkhardt, Jan‐Karl , Hafeez, Muhammad Ubaid , Kan, Peter , Nossek, Erez , Zhang, Hongqi , Rinaldo, Lorenzo , Stapleton, Christopher J. , Rabinov, James D. , Patel, Aman B. , Marotta, Thomas R. , Dmytriw, Adam A. , Burkhardt, Jan-Karl , Kan, Peter , Rinaldo, Lorenzo , Lanzino, Giuseppe , Dmytriw, Adam A , Dibas, Mahmoud , Diestro, Jose Danilo B , Harker, Pablo , Regenhardt, Robert W , Hafeez, Muhammad U , Burkhardt, Jan‐Karl , Parra-Fariñas, Carmen , Bernstock, Joshua D. , Griessenauer, Christoph J. , Grandhi, Ramesh , Taussky, Philipp , Hong, Tao , Lanzino, Giuseppe , Roy, Daniel C.

Neurosurgery | September 8, 2021 | Volume: 89 | Issue: 6 | Pages: 1112-1121

10.1093/neuros/nyab365 | PMID 34624100 Get It

Abstract BACKGROUND Open surgery has traditionally been preferred for the management of bifurcation middle cerebral artery (MCA) aneurysms. Flow diverting stents present a novel endovascular strategy for aneurysm treatment. OBJECTIVE To add to the limited literature describing the outcomes and complications in the use of flow diverters for the treatment of these complex aneurysms. METHODS This is a multicenter retrospective review of MCA bifurcation aneurysms undergoing flow diversion. We assessed post-treatment radiological outcomes and both thromboembolic and hemorrhagic complications. RESULTS We reviewed the outcomes of 54 aneurysms treated with flow diversion. Four (7.4%) of the aneurysms had a history of rupture (3 remote and 1 acute). Fourteen (25.9%) of the aneurysms already underwent either open surgery or coiling prior to flow diversion. A total of 36 out of the 45 aneurysms (80%) with available follow-up data had adequate aneurysm occlusion with a median follow-up time of 12 mo. There were no hemorrhagic complications but 16.7% (9/54) had thromboembolic complications. CONCLUSION Flow diverting stents may be a viable option for the endovascular treatment of complex bifurcation MCA aneurysms. However, compared to published series on the open surgical treatment of this subset of aneurysms, flow diversion has inferior outcomes and are associated with a higher rate of complications.
Crossing the Carotid Siphon: Techniques to Facilitate Distal Access in Tortuous Anatomy: 2-Dimensional Operative Video
Hadley, Caroline , Burkhardt, Jan‐Karl , Johnson, Jeremiah N., Kan, Peter , Bain, Mark, Bendock, Bernard, Binning, Mandy J., Boulos, Alan S. , Crowley, Webster, Fessler, Richard D., Guterman, Lee R., Hoit, Daniel , Hopkins, L. Nelson , Howington, Jay U., James, Robert F. , Jankowitz, Brian T. , Khalessi, Alex A, Kim, Louis J. , Langer, David J. , Levitt, Michael R. , Mack, William J. , Mericle, Robert A., Ogilvy, Chris, Replogle, Robert, Riina, Howard A. , Saugaveau, Eric, Schirmer, Clemens M. , Spiotta, Alex, Sultan, Ali, Turner, Raymond D , Veznedaroglu, Erol, Welch, Babu G. , White, Jonathan, Ogilvy, Christopher S. , Levitt, Michael R , Burkhardt, Jan-Karl , Schirmer, Clemens M , Ogilvy, Christopher S , Burkhardt, Jan‐Karl , Arthur, Adam Stephen , Grande, Andrew Walker , Hanel, Ricardó A. , Kim, Louis J. , Lanzino, Giuseppe , Levy, Elad I. , Lopes, Demetrius K. , Mocco, J , Pandey, Aditya S , Ringer, Andrew J. , Rodriguez, Rafael, Siddiqui, Adnan H. , Tawk, Rabih G. , Thomas, Ajith J , White, Jonathan A.

Operative Neurosurgery | April 6, 2021 | Volume: 21 | Issue: 1 | Pages: E41-E42

10.1093/ons/opab084 | PMID 33822191 Get It

Abstract As capabilities for endovascular treatment of intracranial vascular pathologies continue to expand, the need for access to the distal internal carotid artery with rigid support catheter systems continues to increase. One of the dominant factors limiting this access is patient anatomy, specifically vessel tortuosity. Increased tortuosity of the carotid siphon is a frequently encountered anatomic variant and may complicate endovascular procedures in adults and children. 1,2 Failed attempts to navigate the carotid siphon with a distal access catheter carry a risk of vessel injury and treatment failure. For this reason, techniques that aid in supporting safe advancement of a distal access catheter across a tortuous carotid siphon are essential. 3,4 In this video, we demonstrate 2 ways in which this may be accomplished. The first technique uses a larger diameter microcatheter, such as the AXS Offset catheter (Stryker, Kalamazoo, Michigan), to increase support for the distal access catheter, while the second uses a buddy wire technique to accomplish this increased support. Both of these techniques can help increase the safety of navigating a tortuous carotid siphon and increase the likelihood of successful treatment. The procedures shown were performed with the informed consent of the patients.