Citations

Mayo Clinic

Clear

28 citation(s) found for "J, Park Soon".

Echocardiographic Variables After Left Ventricular Assist Device Implantation Associated With Adverse Outcome
Topilsky, Yan , Hasin, Tal , Oh, Jae K. , Borgeson, Daniel D., Boilson, Barry A. , Schirger, John A., Clavell, Alfredo L. , Frantz, Robert P. , Tsutsui, Rayji , Liu, Mingya, Maltais, Simon, Kushwaha, Sudhir S. , Pereira, Naveen L. , Park, Soon J., Frantz, Robert P , Topilsky, Yan

Circulation: Cardiovascular Imaging | September 22, 2011 | Volume: 4 | Issue: 6 | Pages: 648-661

10.1161/circimaging.111.965335 | PMID 21940507 Get It

Background— Operative mortality after left ventricular assist device (LVAD) implantation is heavily influenced by patient selection and the technical difficulty of surgery. However, how we treat our patients and LVAD setting may affect the patient outcome beyond this period. We postulated that the presence of echocardiographic variables 1 month after surgery suggesting appropriate degree of LV unloading and an adequate forward flow would be important in determining clinical outcomes after the initial successful LVAD implantation. Methods and Results— We retrospectively analyzed various variables in echocardiographic examinations performed 30 days after LVAD implant in 76 consecutive patients receiving continuous flow device for their association with a compound end point (90-day mortality, readmission for heart failure, or New York Heart Association class III or higher at the end of the 90-day period). The echocardiographic associations examined included estimated LVAD flow, with and without native LV contribution, interventricular septal position, the status of aortic valve opening, an estimated left atrial pressure (ELAP), the mitral flow E-wave deceleration time, and the ratio of deceleration time to E-wave velocity (mitral deceleration index [MDI]). Four patients died during the 30- to 90-day period, 6 patients were readmitted for heart failure, and 25 patients were considered to have New York Heart Association class III or higher at the end of the 90-day period. Variables associated with adverse outcome included increased ELAP (odds ratio, 1.30 [1.16–1.48]; P <0.0001), MDI <2 ms/[cm/s] (odds ratio, 4.4 implantation [1.22–18]; P =0.02) and decreased tricuspid lateral annulus velocity (odds ratio, 0.70 implantation [0.48–0.95]; P =0.02). A leftward deviation of interventricular septum was associated with a worse outcome (odds ratio, 3.03 implantation [1.21–13.3]; P =0.01). Conclusions— Mortality and heart failure after LVAD surgery appear to be predominantly determined by echocardiographic evidence of inefficient unloading of the left ventricle and persistence of right ventricular dysfunction. Increased estimated LA pressure and short MDI are associated with worse mid term outcome. Leftward deviation of the septum is associated with worse outcome as well.
Aortic Valve Replacement in the Elderly
Ashikhmina, Elena, Schaff, Hartzell V. , Sundt, Thoralf M. , Suri, Rakesh M. , Park, Soon J., Burkhart, Harold M. , Daly, Richard C. , Li, Zhuo , Dearani, Joseph A. , Li, Zhuo , Schaff, Hartzell

Circulation | August 9, 2011 | Volume: 124 | Issue: 9 | Pages: 1070-1078

10.1161/circulationaha.110.987560 | PMID 21824918 Get It

Background— Few data exist on long-term outcomes of elderly patients after aortic valve replacement. We evaluated latest follow-up information for patients ≥70 years of age after aortic valve replacement. Methods and Results— Late overall survival of 2890 consecutive patients ≥70 years of age who underwent aortic valve replacement between January 1993 and December 2007 was reviewed retrospectively, analyzed, and stratified by preoperative and intraoperative variables. Observed 5-, 10-, and 15-year late postoperative survival was lower than generally expected (68%, 34%, and 8% versus 70%, 42%, and 20%, respectively; P <0.001). Independent predictors of late death included older age, renal failure, diabetes mellitus, stroke, myocardial infarction, immunosuppression, prior coronary artery bypass grafting, implanted pacemaker, lower ejection fraction, hypertension, and New York Heart Association class III or IV. After stratification by age–comorbidity risk score, 10-year survival for the lowest-risk group (n=946 [33%]) was similar to expected survival (55% versus 55%; P =0.50), but for the highest-risk group (n=564 [20%]), survival was significantly lower than expected (9% versus 26%; P <0.001). For 229 pairs of propensity-matched patients with mechanical or biological prostheses, survival was not significantly different (67%, 40%, and 19% versus 71%, 45%, and 7% at 5, 10, and 15 years, respectively; P =0.81). Structural deterioration of bioprostheses occurred in 64 patients (2.4%). Conclusions— Survival of elderly patients after aortic valve replacement is influenced by age and preoperative comorbidities; 33% at lowest risk had overall survival similar to that of an age- and sex-matched general population. There was no sufficient evidence that valve type affected survival. Structural deterioration of aortic bioprostheses was rare.
Prosthetic Aortic Valve Stenosis in End-Stage Renal Failure
Ters, Mirelle El, Mankad, Sunil , Keddis, Mira T. , Park, Soon, Qian, Qi , Mao, Michael A.

International Journal of Nephrology | May 15, 2011 | Volume: 2011 | Issue: No issue available | Pages: 1-5

10.4061/2011/386368 | PMID 21647316 Get It

Although renal failure is one of the known comorbidities associated with rapid progression of aortic stenosis, it is unclear whether hemodialysis alters the progression of prosthetic aortic valve stenosis. We describe a 79-year-old female who underwent bioprosthetic aortic valve replacement 8 years ago with stable prosthetic valve area for the initial 6 years. In the last two years, coinciding with the initiation of maintenance hemodialysis, she developed progressive prosthetic valve stenosis to the point of clinical decompensation. She underwent a second prosthetic aortic valve replacement with symptom resolution. This case suggests that circulating milieu in end-stage renal failure and dialysis can accelerate the progression of prosthetic aortic valve stenosis. More frequent clinical followup and surveillance echocardiogram for dialysis patients with bioprosthetic aortic valve may facilitate timely management of valvular stenosis.
Preoperative Factors Associated With Adverse Outcome After Tricuspid Valve Replacement
Topilsky, Yan , Khanna, Amber , Oh, Jae K. , Enriquez‐Sarano, Maurice , Jeon, Yang Bin , Sundt, Thoralf M. , Schaff, Hartzell V. , Park, Soon J., Nishimura, Rick A. , Enriquez-Sarano, Maurice , Khanna, Amber D , Schaff, Hartzell , Topilsky, Yan

Circulation | April 26, 2011 | Volume: 123 | Issue: 18 | Pages: 1929-1939

10.1161/circulationaha.110.991018 | PMID 21518976 Get It

Background— Preoperative factors associated with increased mortality and worse outcome after tricuspid valve replacement in patients with severe tricuspid regurgitation are poorly understood. Methods and Results— We retrospectively analyzed 189 patients (37% men; age, 67.5±11.3 years) who underwent tricuspid valve replacement for severe tricuspid regurgitation. Operative mortality rate was 10%, and was associated with intra-aortic balloon pump (odds ratio, 3.2; 95% confidence interval, 1.9 to 5.6; P <0.0001) or the presence of severe symptoms (New York Heart Association class IV relative to classes II and/or III) at the time of surgery (1.7; 95% confidence interval, 1.05 to 2.8; P =0.02). At the end of follow-up (29.3±27.1 months), 70 patients (37%) died, 6 (3%) needed tricuspid reoperation, and 41 (21.7%) were readmitted for heart failure. Seventy-eight patients (41.3%) were free from cardiovascular events (death, tricuspid reoperation, or heart failure admissions). The only echocardiographic parameter independently associated with adverse outcomes was a decrease in the right index of myocardial performance ratio. All-cause mortality was independently associated with a higher Charlson index (hazard ratio, 1.18; 95% confidence interval, 1.01 to 1.36; P =0.03), shorter right index of myocardial performance ratio (0.91; 95% confidence interval, 0.87 to 0.96; P =0.005), and preoperative New York Heart Association IV class (1.71; 95% confidence interval, 1.3 to 2.2; P <0.0001). In 68 patients with isolated tricuspid valve replacement, the associations between short right index of myocardial performance ratio, high Charlson index, New York Heart Association class IV, and increased mortality remained significant. Conclusions— Tricuspid valve replacement for severe tricuspid regurgitation can be performed with an acceptable operative mortality if patients undergo surgery before the onset of advanced heart failure symptoms. Late mortality is associated with a high preoperative Charlson index, short right index of myocardial performance ratio, and advanced New York Heart Association class.
Application of Computer Modeling in Systemic VAD Support of Failing Fontan Physiology
Durham, Lucian A. , Burkhart, Harold M. , Joyce, Lyle D., Cetta, Frank , Phillips, Sabrina D. , Sundareswaran, Kartik S., Farrar, David J. , Park, Soon J., Dearani, Joseph A. , Cabalka, Allison K.

World Journal for Pediatric and Congenital Heart Surgery | April 13, 2011 | Volume: 2 | Issue: 2 | Pages: 243-248

10.1177/2150135110397386 | PMID 23804979 Get It

Although the Fontan procedure has been enormously successful in palliation of single-ventricle patients, many seem to experience progressive failure of the Fontan circulation over time. Ventricular assist devices (VADs) have developed into stable platforms for long-term support of adult patients with heart failure. Given the success of axial flow devices, it was hypothesized that the technology could provide clinical benefit to failing Fontan patients. The aim of this study was to use a computer model to evaluate VAD support in failing Fontan physiology. A computer model of Fontan circulation with heart failure was developed and the HeartMate II (HM II) (Thoratec Corp) axial flow ventricular assist device was connected to this model in a systemic configuration to examine its impact. Cardiac catheterization data from 7 patients (8 catheterization studies) with failing Fontan physiology were applied to this model to evaluate the impact of using the HM II in this manner. When the HM II was used in a systemic configuration at 8000 rpm, there was a 35% decrease in the systemic venous pressure in the Fontan circuit and a 63% decrease in pulmonary capillary wedge pressure with a resultant 41% increase in CI. The model also predicted patient-specific parameters where the VAD may not benefit the patient, such as fixed elevated pulmonary vascular resistance, low systemic ventricular end-diastolic pressure, and high unresponsive systemic vascular resistance. These data suggest a potential benefit from application of axial flow VAD technology in the management of failing Fontan physiology. Clinical correlation will allow for refinement of this model as a predictive tool in discerning which patients may benefit from placement of a VAD and what issues must be addressed prior to implanting the device.
Left Ventricular Assist Device Therapy in Patients With Restrictive and Hypertrophic Cardiomyopathy
Topilsky, Yan , Pereira, Naveen L. , Shah, Dipesh K. , Boilson, Barry A. , Schirger, John A., Kushwaha, Sudhir S. , Joyce, Lyle D., Park, Soon J., Topilsky, Yan , Topilsky, Yan

Circulation: Heart Failure | February 9, 2011 | Volume: 4 | Issue: 3 | Pages: 266-275

10.1161/circheartfailure.110.959288 | PMID 21303989 Get It

Background— Left ventricular assist device (LVAD) is being increasingly used in patients with end-stage dilated and ischemic cardiomyopathy. There have been no clinical trials addressing the use of LVAD therapy in patients with end-stage heart failure caused by restrictive (RCM) or hypertrophic cardiomyopathy (HCM). The purpose of this study was therefore to analyze the outcome of LVAD therapy in these patients. Methods and Results— Eighty-three patients received continuous axial flow LVAD (Heart mate II, Thoratec, Pleasanton, CA) from February 2007 to May 2010 at our institution. We analyzed the baseline characteristics and surgical and long-term impact of LVAD therapy in 8 patients with RCM or HCM and compared their outcomes with the 75 patients with dilated and ischemic cardiomyopathy. Compared with patients with ischemic or dilated cardiomyopathy, patients with RCM and HCM have significantly smaller left ventricular end-diastolic dimensions (52.5±6 mm versus 68.6±8 mm; P <0.0001) and increased thickness of septal (16 [12, 19] mm versus 10[8.5, 11] mm, P =0.0003) and higher left ventricular ejection fraction (21 [20, 36]% versus 17 [15, 22]%; P =0.0009). We found no difference in early mortality (12.5% versus 9.3%, P =0.57) or length of hospital stay (11 [8, 45] days versus 18.5 [12.2, 27.7] days; P =0.51) between the 2 groups. The right atrial pressure was higher (18 [15, 20] mm Hg versus 12 [9, 15] mm Hg, P =0.03), and pump flow was lower (4.3 [3.8, 4.5] L versus 5.2 [4.7, 5.5] L, P =0.001) after LVAD implantation in patients with RCM and HCM. Central venous catheter related infections were more common in patients with RCM and HCM (87.5% versus 44.5%, P =0.006). There was no difference in the total number of blood units transfused. Median (min, max) follow-up duration after LVAD implantation was 166 [1, 1044] days. The 1-year actuarial survival rate was not different between the 2 groups (87.5% [95% confidence interval, 52.9% to 97.8%] versus 73.2 [95% confidence interval, 60% to 85%]; P =0.77). Conclusions— Our preliminary data show that patients with end-stage heart failure caused by RCM or HCM may benefit from continuous axial flow LVAD therapy. This small study suggests that mortality is comparable with those patients who have dilated or ischemic cardiomyopathy, but right heart failure, prolonged inotropic use, and central venous catheter infections are more common in patients with RCM and HCM who were treated with LVAD. Because of the small numbers the differences should be interpreted cautiously, and prospective clinical trials would be required to recommend this therapy for these patients as bridge to transplantation or destination treatment.
Focused Review on Transthoracic Echocardiographic Assessment of Patients with Continuous Axial Left Ventricular Assist Devices
Topilsky, Yan , Maltais, Simon, Oh, Jae K. , Atchison, Fawn W., Perrault, Louis P. , Carrier, Michel, Park, Soon J., Topilsky, Yan , Topilsky, Yan

Cardiology Research and Practice | February 8, 2011 | Volume: 2011 | Issue: No issue available | Pages: 1-11

10.4061/2011/187434 | PMID 21331332 Get It

Left ventricular assist devices (LVADs) are systems for mechanical support for patients with end-stage heart failure. Preoperative, postoperative and comprehensive followup with transthoracic echocardiography has a major role in LVAD patient management. In this paper, we will present briefly the hemodynamics of axial-flow LVAD, the rationale, and available data for a complete and organized echocardiographic assessment in these patients including preoperative assessment, postoperative and long-term evaluation.
Genomic profiling of the human heart before and after mechanical support with a ventricular assist device reveals alterations in vascular signaling networks
Grindle, Suzanne, Han, Xinqiang , Park, Soon, Chen, Yingjie , Bache, Robert J. , Mariash, Ami, Guan, Zhanjun, Ormaza, Sofia, Thompson, Jeanne, Graziano, Judith A., Lazaro, Shireen E. de Sam, Pan, Shuchong, Simari, Robert D., Miller, Leslie W., Hall, Jennifer L. , Fermin, David , Lazaro, Shireen de Sam

Physiological Genomics | February 17, 2004 | Volume: 17 | Issue: 3 | Pages: 283-291

10.1152/physiolgenomics.00004.2004 | PMID 14872006 Get It

Mechanical unloading of the heart with a left ventricular assist device (LVAD) significantly decreases mortality in patients with heart failure. Moreover, it provides a human model to define the critical regulatory genes governing myocardial remodeling in response to significant reductions in wall stress. Statistical analysis of a gene expression library of 19 paired human heart samples harvested at the time of LVAD implant and again at explant revealed a set of 22 genes that were downregulated and 85 genes that were upregulated in response to mechanical unloading with a false discovery rate of less than 1%. The analysis revealed a high percentage of genes involved in the regulation of vascular networks including neuropilin-1 (a VEGF receptor), FGF9, Sprouty1, stromal-derived factor 1, and endomucin. Taken together these findings suggest that mechanical unloading alters the regulation of vascular organization and migration in the heart. In addition to vascular signaling networks, GATA-4 binding protein, a critical mediator of myocyte hypertrophy, was significantly downregulated following mechanical unloading. In summary, these findings may have important implications for defining the role of mechanical stretch and load on autocrine/paracrine signals directing vascular organization in the failing human heart and the role of GATA-4 in orchestrating reverse myocardial remodeling. This unbiased gene discovery approach in paired human heart samples has the potential to provide critical clues to the next generation of therapeutic treatments aimed at heart failure.