Citations

Mayo Clinic

Clear

2817 citation(s) found for "C, Liu".

P3‐098: REDUCED GENOMIC DIVERSITY AS A RISK FACTOR FOR NONFAMILIAL YOUNG ONSET ALZHEIMER'S DISEASE
Caselli, Richard J. , Woodruff, Bryan K. , Lindor, Noralane M. , Wieben, Eric D. , Huentelman, Matthew J. , Liu, Li , Piras, Ignazio Stefano

Alzheimer's & Dementia | October 22, 2018 | Volume: 14 | Issue: 7S_Part_20 | Pages: No page available

10.1016/j.jalz.2018.06.1454 Get It

Automation of routine elements for spot‐scanning proton patient‐specific quality assurance
Morales, Danairis Hernandez, Shan, Jie , Augustine, Kurt E., Davis, Michael J. , Fatyga, M., Johnson, J. , Mundy, Daniel W. , Shen, Jiajian , Younkin, James E. , Stoker, Joshua B., Hernandez Morales, Danairis, Bues, Martin , Fatyga, Mirek, Johnson, Jedediah E, Shen, Jiajian , Liu, Wei

Medical Physics | October 19, 2018 | Volume: 46 | Issue: 1 | Pages: 5-14

10.1002/mp.13246 | PMID 30339270 Get It

PurposeAt our institution, all proton patient plans undergo patient‐specific quality assurance (PSQA) prior to treatment delivery. For intensity‐modulated proton beam therapy, quality assurance is complex and time consuming, and it may involve multiple measurements per field. We reviewed our PSQA workflow and identified the steps that could be automated and developed solutions to improve efficiency.MethodsWe used the treatment planning system's (TPS) capability to support C# scripts to develop an Eclipse scripting application programming interface (ESAPI) script and automate the preparation of the verification phantom plan for measurements. A local area network (LAN) connection between our measurement equipment and shared database was established to facilitate equipment control, measurement data transfer, and storage. To improve the analysis of the measurement data, a Python script was developed to automatically perform a 2D–3D γ‐index analysis comparing measurements in the plane of a two‐dimensional detector array with TPS predictions in a water phantom for each acquired measurement.ResultsDevice connection via LAN granted immediate access to the plan and measurement information for downstream analysis using an online software suite. Automated scripts applied to verification plans reduced time from preparation steps by at least 50%; time reduction from automating γ‐index analysis was even more pronounced, dropping by a factor of 10. On average, we observed an overall time savings of 55% in completion of the PSQA per patient plan.ConclusionsThe automation of the routine tasks in the PSQA workflow significantly reduced the time required per patient, reduced user fatigue, and frees up system users from routine and repetitive workflow steps allowing increased focus on evaluating key quality metrics.
Imaging and diagnostic advances for intracranial meningiomas
Huang, Raymond Y. , Fougère, Christian la , Vogelbaum, Michael A. , Wen, Patrick Y, Aldape, Kenneth , Nassiri, Farshad , Zadeh, Gelareh , Dunn, Ian F. , Au, Karolyn , Barnhartz-Sloan, Jill, Bi, Wenya Linda, Brastianos, Priscilla K. , Butowski, Nicholas , Carlotti, Carlos Gilberto , Goldbrunner, Roland , Hashizume, Rintaro , Hanemann, C. Oliver , James, David, Jenkinson, Michael D. , Jungk, Christine, Kaufman, Timothy J, Krischek, Boris , Lee, Ian , Liu, Jeff C. , Mamatjan, Yasin , Mansouri, Alireza , Mawrin, Christian , Ng, Ho‐Keung , Pirouzmand, Farhad , Poisson, Laila , Pollo, Bianca , Raleigh, David R. , Sahm, Felix , Saladino, Andrea , Schichor, Christian , Selman, Warren R., Sloan, Andrew E. , Spears, Julian , Snyder, James , Suppiah, Suganth , Tabatabai, Ghazaleh , Tatagiba, Marcos , Tirapelli, Daniela Pretti da Cunha , Tsang, Derek S. , Deimling, Andreas von , Wen, Patrick Y, Walbert, Tobias , Westphal, Manfred , Workewych, Adriana M , Mansouri, Alireza , von Deimling, Andreas , Sahm, Felix , Huang, Raymond , Lee, Ian Y , Bi, Wenya Linda , Griffith, Brent D , Kaufmann, Timothy J. , Schmidt, Nils Ole , Tonn, Joerg-Christian , Wen, Patrick Yung , Cusimano, Michael D. , DiMeco, Francesco , Drummond, Katharine Jann , Galanis, Evanthia , Giannini, Caterina , Herold‐Mende, Christel C. , Horbinski, Craig , Jungk, Christine, Lachance, Daniel Honore , McDermott, Michael , Muñoz, David G. , Noushmehr, Houtan , Perry, Arie , Santarius, Thomas , Schultz, David , Hanemann, C Oliver , Mamatjan, Yasin , Tatagiba, Marcos

Neuro-Oncology | October 18, 2018 | Volume: 21 | Issue: Supplement_1 | Pages: i44-i61

10.1093/neuonc/noy143 | PMID 30649491 Get It

Small‐spot intensity‐modulated proton therapy and volumetric‐modulated arc therapies for patients with locally advanced non‐small‐cell lung cancer: A dosimetric comparative study
Liu, Chenbin , Shan, Jie , Daniels, T.B., Rule, William G., Lara, Pedro R., Korte, Shawn M., Shen, Jiajian , Ding, Xiaoning, Daniels, Thomas B, Schild, Steven E. , Bues, Martin , Shen, Jiajian , Sio, Terence T. , Deng, Wei, Shan, Jie, Lara, Pedro R., Liu, Wei

Journal of Applied Clinical Medical Physics | October 17, 2018 | Volume: 19 | Issue: 6 | Pages: 140-148

10.1002/acm2.12459 | PMID 30328674 Get It

AbstractPurposeTo compare dosimetric performance of volumetric‐modulated arc therapy (VMAT) and small‐spot intensity‐modulated proton therapy for stage III non‐small‐cell lung cancer (NSCLC).Methods and MaterialsA total of 24 NSCLC patients were retrospectively reviewed; 12 patients received intensity‐modulated proton therapy (IMPT) and the remaining 12 received VMAT. Both plans were generated by delivering prescription doses to clinical target volumes (CTV) on averaged 4D‐CTs. The dose‐volume‐histograms (DVH) band method was used to quantify plan robustness. Software was developed to evaluate interplay effects with randomized starting phases of each field per fraction. DVH indices were compared using Wilcoxon rank sum test.ResultsCompared with VMAT, IMPT delivered significantly lower cord Dmax, heart Dmean, and lung V5 Gy[RBE] with comparable CTV dose homogeneity, and protection of other OARs. In terms of plan robustness, the IMPT plans were statistically better than VMAT plans in heart Dmean, but were statistically worse in CTV dose coverage, cord Dmax, lung Dmean, and V5 Gy[RBE]. Other DVH indices were comparable. The IMPT plans still met the standard clinical requirements with interplay effects considered.ConclusionsSmall‐spot IMPT improves cord, heart, and lung sparing compared to VMAT and achieves clinically acceptable plan robustness at least for the patients included in this study with motion amplitude less than 11 mm. Our study supports the usage of IMPT to treat some lung cancer patients.
Standard Operating Procedures for Biospecimen Collection, Processing, and Storage
Fisher, William E., Cruz‐Monserrate, Zobeida , McElhany, Amy L., Hart, Phil A. , Ghosh, Ria , Buren, George Van , Fishman, Douglas S., Rinaudo, Jo Ann, Serrano, José , Srivastava, Sudhir , Mace, Thomas A. , Topazian, Mark , Feng, Ziding , Yadav, Dhiraj , Hughes, Steven J. , Liu, Robert Y., Lu, Emily Y., Orr, Robert Scott, Abouhamze, Amer, Troendle, David M. , Uç, Aliye , Lowe, Mark E. , Conwell, Darwin L. , Whitcomb, David C. , Serrano, Jose , Lesinski, Gregory B , Ghosh, Ria, Pandol, Stephen J. , Orr, Robert, Steen, Hanno , Sellers, Zachary M.

Pancreas | October 16, 2018 | Volume: 47 | Issue: 10 | Pages: 1213-1221

10.1097/mpa.0000000000001171 | PMID 30325860 Get It

Abstract High-quality and well-annotated biorepositories are needed to better understand the pathophysiology and biologic mechanisms of chronic pancreatitis (CP) and its consequences. We report a methodology for the development of a robust standard operating procedure (SOP) for a biorepository based on the experience of the clinical centers within the consortium to study Chronic Pancreatitis, Diabetes and Pancreas Cancer Clinical Centers (CPDPC), supported by the National Cancer Institute and the National Institute for Diabetes and Digestive and Kidney Diseases as a unique multidisciplinary model to study CP, diabetes, and pancreatic cancer in both children and adults. Standard operating procedures from the CPDPC centers were evaluated and consolidated. The literature was reviewed for standard biorepository operating procedures that facilitated downstream molecular analysis. The existing literature on biobanking practices was harmonized with the SOPs from the clinical centers to produce a biorepository for pancreatic research. This article reports the methods and basic principles behind the creation of SOPs to develop a biorepository for the CPDPC. These will serve as a guide for investigators developing biorepositories in pancreas research. Rigorous and meticulous adherence to standardized biospecimen collection will facilitate investigations to better understand the pathophysiology and biologic mechanisms of CP, diabetes, and pancreatic cancer.
Faculty Opinions recommendation of Segment convolutional neural networks (Seg-CNNs) for classifying relations in clinical notes.
Liu, Hongfang

Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature | October 16, 2018 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.3410/f.731974174.793551524 Get It

NucMap: a database of genome-wide nucleosome positioning map across species
Zhao, Yongbing , Wang, Jinyue , Zhang, Hao , Jiang, Meiye , Zhang, Zhewen , Bào, Yīmíng , Zhang, Zhang , Wu, Jiayan , Asmann, Yan W. , Li, Rujiao , Xiao, Jingfa , Fang, Liang , Liu, Yanxia , Wang, Qi , Zhao, Wenming

Nucleic Acids Research | October 10, 2018 | Volume: 47 | Issue: D1 | Pages: D163-D169

10.1093/nar/gky980 | PMID 30335176 Get It

Evaluation of a Thermal-Based Flow Meter for Assessment of Mobile Resting Metabolic Rate Measures
Liu, Nai-Yuan , Deng, Yue , Tsow, Francis , Bridgeman, Devon, Dean, Jane J., Wilson, Janet, Tao, Nongjian , Kulick, Doina , Forzani, Erica , Forzani, Erica S , Xian, Xiaojun , Wilson, Janet L.

Journal of Sensors | October 9, 2018 | Volume: 2018 | Issue: No issue available | Pages: 1-8

10.1155/2018/9186475 Get It

This work evaluates the use of a new flow meter to assess exhalation rate. A mobile indirect calorimeter (MIC) was designed and used to measure resting metabolic rate (RMR), which relies on the measure of O2 consumption rate (VO2) and CO2 production rate (VCO2). The device was produced from a commercially available and well-established indirect calorimeter and implemented with a new flow meter for the purpose of this study. VO2 and VCO2 were assessed by measuring exhalation rates using the new flow meter and O2 and CO2 concentrations in breath using the original colorimetric sensors of the indirect calorimeter. The new flow meter was based on a thermal flow meter (TFM) affixed to an orifice with a diameter of 6.8 mm used as a passage for exhaled breath from 16 subjects. The results were compared with a metabolic cart (Medical Graphics), which was connected in series to the modified device. We found that 69% of the results had more than a 10% difference between the modified MIC device and the reference instrument, suggesting that the sensitivity of the thermal flow meter changed over time, which precluded its use as a flow meter for breath flow rate measurement.
Intertumoral Heterogeneity of CD3+ and CD8+ T-Cell Densities in the Microenvironment of DNA Mismatch-Repair–Deficient Colon Cancers: Implications for Prognosis
Yoon, Harry H. , Shi, Qian , Heying, Erica N., Murányi, Andrea , Bredno, Joerg , Ough, Faith , Djalilvand, Azita, Clements, June, Bowermaster, Rebecca, Shanmugam, Kandavel , Shi, Qian , Liu, Wen-Wei, Barnes, Michael, Alberts, Steven R. , Sinicrope, Frank A.

Clinical Cancer Research | October 9, 2018 | Volume: 25 | Issue: 1 | Pages: 125-133

10.1158/1078-0432.ccr-18-1984 | PMID 30301825 Get It

Abstract Purpose: Colorectal cancers with deficient DNA mismatch repair (dMMR) are presumed to uniformly have dense lymphocytic infiltration that underlies their favorable prognosis and is critical to their responsiveness to immunotherapy, as compared with MMR-proficient (pMMR) tumors. We examined T-cell densities and their potential heterogeneity in a large cohort of dMMR tumors. Experimental Design: CD3+ and CD8+ T-cell densities were quantified at the invasive margin (IM) and tumor core (CT) in 561 stage III colon cancers (dMMR, n = 278; pMMR, n = 283) from a phase III adjuvant trial (N0147). Their association with overall survival (OS) was determined using multivariable Cox analysis. Results: Although CD3+ and CD8+ T-cell densities in the tumor microenvironment were higher in dMMR versus pMMR tumors overall, intertumoral heterogeneity in densities between tumors was significantly higher by 30% to 88% among dMMR versus pMMR cancers (P < 0.0001 for all four T-cell subtypes [CD3+IM, CD3+CT, CD8+IM, CD8+CT]). A substantial proportion of dMMR tumors (26% to 35% depending on the T-cell subtype) exhibited T-cell densities as low as that in the bottom half of pMMR tumors. All four T-cell subtypes were prognostic in dMMR with CD3+IM being the most strongly prognostic. Low (vs. high) CD3+IM was independently associated with poorer OS among dMMR (HR, 4.76; 95% confidence interval, 1.43–15.87; P = 0.0019) and pMMR tumors (P = 0.0103). Conclusions: Tumor-infiltrating T-cell densities exhibited greater intertumoral heterogeneity among dMMR than pMMR colon cancers, with CD3+IM providing robust stratification of both dMMR and pMMR tumors for prognosis. Potentially, lower T-cell densities among dMMR tumors may contribute to immunotherapy resistance.
Robust radiotherapy planning
Unkelbach, Jan , Alber, M., Bangert, Mark, Bokrantz, Rasmus, Chan, Timothy C. Y. , Deasy, Joseph O. , Fredriksson, Albin , Gorissen, Bram L. , Herk, Marcel van , Liu, Wei , Mahmoudzadeh, Houra , Nohadani, Omid , Siebers, Jeffrey V. , Xu, Huijun , Witte, Marnix , Xu, Huijun , Liu, Wei

Physics in Medicine & Biology | October 5, 2018 | Volume: 63 | Issue: 22 | Pages: 22TR02

10.1088/1361-6560/aae659 | PMID 30418942 Get It

Abstract Motion and uncertainty in radiotherapy is traditionally handled via margins. The clinical target volume (CTV) is expanded to a larger planning target volume (PTV), which is irradiated to the prescribed dose. However, the PTV concept has several limitations, especially in proton therapy. Therefore, robust and probabilistic optimization methods have been developed that directly incorporate motion and uncertainty into treatment plan optimization for intensity modulated radiotherapy (IMRT) and intensity modulated proton therapy (IMPT). Thereby, the explicit definition of a PTV becomes obsolete and treatment plan optimization is directly based on the CTV. Initial work focused on random and systematic setup errors in IMRT. Later, inter-fraction prostate motion and intra-fraction lung motion became a research focus. Over the past ten years, IMPT has emerged as a new application for robust planning methods. In proton therapy, range or setup errors may lead to dose degradation and misalignment of dose contributions from different beams – a problem that cannot generally be addressed by margins. Therefore, IMPT has led to the first implementations of robust planning methods in commercial planning systems, making these methods available for clinical use. This paper first summarizes the limitations of the PTV concept. Subsequently, robust optimization methods are introduced and their applications in IMRT and IMPT planning are reviewed.