Alzheimer’s disease (AD) and Alzheimer’s Related Dementias (ADRD) are projected to affect 50 million people globally in the coming decades. Clinical research suggests that Mild Cognitive Impairment (MCI), a precursor to dementia, offers a critical window of opportunity for lifestyle interventions to delay or prevent the progression of AD/ADRD. Previous research indicates that lifestyle changes, including increased physical exercise, reduced caloric intake, and mentally stimulating activities, can reduce the risk of MCI. Early detection of MCI is challenging due to subtle and often unnoticed cognitive decline and is traditionally monitored through infrequent clinical tests. In this research, the Smart Driving System, a novel, unobtrusive, and economical technology to detect early stages of neurodegenerative diseases, is presented. The system comprises a multi-modal biosensing array (MMS) and AI algorithms, including driving performance and driver’s biometrics, offering insights into a driver’s cognitive function. This publication is the first work reported towards the ultimate goal of developing the Smart Driving Device and App, integrating it into vehicles, and validating its effectiveness in detecting MCI through comprehensive pilot studies.
Threshold-Responsive Colorimetric Sensing System for the Continuous Monitoring of Gases
Colorimetric sensors are widely used because of their inherent advantages including accuracy, rapid response, ease-of-use, and low costs; however, they usually lack reusability, which precludes the continuous use of a single sensor. We have developed a threshold-responsive colorimetric system that enables repeated analyte measurements by a single colorimetric sensor. The threshold responsive algorithm automatically adjusts the sensor exposure time to the analyte and measurement frequency according to the sensor response. The system registers the colorimetric sensor signal change rate, prevents the colorimetric sensor from reaching saturation, and allows the sensor to fully regenerate before the next measurement is started. The system also addresses issues common to colorimetric sensors, including the response time and range of detection. We demonstrate the benefits and feasibility of this novel system, using colorimetric sensors for ammonia and carbon dioxide gases for continuous monitoring of up to (at least) 60 detection cycles without signs of analytical performance degradation of the sensors.
Evaluation of a Thermal-Based Flow Meter for Assessment of Mobile Resting Metabolic Rate Measures
This work evaluates the use of a new flow meter to assess exhalation rate. A mobile indirect calorimeter (MIC) was designed and used to measure resting metabolic rate (RMR), which relies on the measure of O2 consumption rate (VO2) and CO2 production rate (VCO2). The device was produced from a commercially available and well-established indirect calorimeter and implemented with a new flow meter for the purpose of this study. VO2 and VCO2 were assessed by measuring exhalation rates using the new flow meter and O2 and CO2 concentrations in breath using the original colorimetric sensors of the indirect calorimeter. The new flow meter was based on a thermal flow meter (TFM) affixed to an orifice with a diameter of 6.8 mm used as a passage for exhaled breath from 16 subjects. The results were compared with a metabolic cart (Medical Graphics), which was connected in series to the modified device. We found that 69% of the results had more than a 10% difference between the modified MIC device and the reference instrument, suggesting that the sensitivity of the thermal flow meter changed over time, which precluded its use as a flow meter for breath flow rate measurement.