Citations

Mayo Clinic

Clear

596 citation(s) found for "Ma, Liang".

Clinical Outcomes and Bacterial Characteristics of Carbapenem-resistant Acinetobacter baumannii Among Patients From Different Global Regions
Wang, Minggui , Ge, Lizhao , Chen, Liang , Komarow, Lauren , Hanson, Blake , Cober, Eric , Alenazi, Thamer H. , Xie, Qing , Liu, Zhengyin , Li, Lanjuan , Yu, Yunsong , Gao, Hainv , Figueroa, Jairo, Herc, Erica , Córdova, Ezequiel , Weston, Gregory , Kaye, Keith S. , Dhar, Sorabh , Munita, José M. , Salata, Robert A. , Vilchez, Samuel, Stryjewski, Martín E. , Iovleva, Alina , Evans, Scott , Baum, Keri, Hill, Carol , Kreiswirth, Barry N. , Patel, Robin , Arias, Cesar A, Chambers, Henry F. , Fowler, Vance G. , Satlin, Michael J. , Investigators, Multi-Drug Resistant Organism Network, Zhang, Fujie , Castelnuovo, Valentina Di, Gutierrez, Jose Millan Oñate, Evans, Beth , Cross, H. R. , Arias, Rebekka M. , Fowler, Vance G, Ordóñez, Karen , Li, Linghua , Kreiswirth, Barry N , Desai, Samit, Rioseco, María Luisa, Vilchez, Samuel, Sánchez, Marisa , Valderrama, Sandra , Figueroa, Jairo, Arias, Cesar A, Dinh, An Q , Panesso, Diane, Rydell, Kirsten, Tran, Truc T. , Jiang, Jianping , Xu, Xiaogang , Spencer, María, Marshall, Steven H. , Rudin, Susan D., Greenwood-Quaintance, Kerry, Schmidt-Malan, Suzannah M., Revolinski, Sara , Wortmann, Glenn , Kalayjian, Robert C. , Ostrowsky, Belinda , Patel, Gopi , Eiras, Daniel , Garcia-Diaz, Julia, Farrell, John J. , Paterson, David L, Kaye, Keith S, Waters, Mary Jo, Eilertson, Brandon , Ng, Oon Tek , De, Partha Pratim, Chew, Kean Lee , Smitasin, Nares , Gallagher, Jason C , Leroi, Marcel , McCarty, Todd P , Lautenbach, Ebbing , Hanson, Blake, Perez, Federico, Banerjee, Ritu , Dhar, Sorabh, Westblade, Lars F. , Yu, Yunsong , Cordova, Ezequiel , Kaye, Keith S , Evans, Scott R , Patel, Robin , van Duin, David , Pérez, Federico , Jiang, Jianping , Chen, Liang , Wang, Minggui , Munita, Jose M , Reyes, Jinnethe , Zong, Zhiyong , Kanj, Souha S. , Tambyah, Paul Anantharajah , Garcia‐Diaz, Julia , Villegas, María Virginia , Kreiswirth, Barry N , Paterson, David L. , Arias, Cesar A, Bonomo, Robert A. , Fowler, Vance G. , Doi, Yohei , Investigators, Multi-Drug Resistant Organism Network, Lok, Judith J. , Richter, Susan, Anderson, Deverick J. , Evans, Beth, Cross, Heather R, Fowler, Vance G, Jacob, Jesse T. , Manca, Claudia , Vilchez, Samuel, Figueroa, Jairo, Arias, Cesar A, Hu, Fupin , Su, Jiachun , Wang, Minggui, Xu, Xiaogang, Yang, Yang, Huskins, W. Charles , Greenwood‐Quaintance, Kerryl E. , Kim, Angela , Garcia-Diaz, Julia, Salcedo, Soraya , Henderson, Andrew , Paterson, David L, Kaye, Keith S, Fries, Bettina C. , Marimuthu, Kalisvar , Peleg, Anton Yariv , Xiao, Yonghong , Garner, Omai B. , Abbo, Lilian M. , Han, Jennifer , Wong, Darren , Hanson, Blake, Díaz, Lorena

Clinical Infectious Diseases | September 22, 2023 | Volume: 78 | Issue: 2 | Pages: 248-258

10.1093/cid/ciad556 | PMID 37738153 Get It

Abstract Background Carbapenem-resistant Acinetobacter baumannii (CRAb) is 1 of the most problematic antimicrobial-resistant bacteria. We sought to elucidate the international epidemiology and clinical impact of CRAb. Methods In a prospective observational cohort study, 842 hospitalized patients with a clinical CRAb culture were enrolled at 46 hospitals in five global regions between 2017 and 2019. The primary outcome was all-cause mortality at 30 days from the index culture. The strains underwent whole-genome analysis. Results Of 842 cases, 536 (64%) represented infection. By 30 days, 128 (24%) of the infected patients died, ranging from 1 (6%) of 18 in Australia-Singapore to 54 (25%) of 216 in the United States and 24 (49%) of 49 in South-Central America, whereas 42 (14%) of non-infected patients died. Bacteremia was associated with a higher risk of death compared with other types of infection (40 [42%] of 96 vs 88 [20%] of 440). In a multivariable logistic regression analysis, bloodstream infection and higher age-adjusted Charlson comorbidity index were independently associated with 30-day mortality. Clonal group 2 (CG2) strains predominated except in South-Central America, ranging from 216 (59%) of 369 in the United States to 282 (97%) of 291 in China. Acquired carbapenemase genes were carried by 769 (91%) of the 842 isolates. CG2 strains were significantly associated with higher levels of meropenem resistance, yet non-CG2 cases were over-represented among the deaths compared with CG2 cases. Conclusions CRAb infection types and clinical outcomes differed significantly across regions. Although CG2 strains remained predominant, non-CG2 strains were associated with higher mortality. Clinical Trials Registration. NCT03646227.
Poor Sensitivity of the MALDI Biotyper® MBT Subtyping Module for Detection of Klebsiella pneumoniae Carbapenemase (KPC) in Klebsiella Species
Cuello, Luz , Otero, Judith Álvarez , Greenwood‐Quaintance, Kerryl E. , Chen, Liang , Hanson, Blake , Komarow, Lauren , Ge, Lizhao , Lancaster, Zane D., Gordy, Garrett G. , Patel, Robin , Alvarez Otero, Judith, Chen, Liang , Patel, Robin , Reyes, Jinnethe , Schuetz, Audrey N.

Antibiotics | September 20, 2023 | Volume: 12 | Issue: 9 | Pages: 1465

10.3390/antibiotics12091465 | PMID 37760762 Get It

Rapid detection of Klebsiella pneumoniae carbapenemase (KPC) in the Klebsiella species is desirable. The MALDI Biotyper® MBT Subtyping Module (Bruker Daltonics) uses an algorithm that detects a peak at ~11,109 m/z corresponding to a protein encoded by the p019 gene to detect KPC simultaneously with organism identification by a matrix-assisted laser desorption ionization–time-of-flight mass spectrometry (MALDI-ToF MS). Here, the subtyping module was evaluated using 795 clinical Klebsiella isolates, with whole genome sequences used to assess for blaKPC and p019. For the isolates identified as KPC positive by sequencing, the overall sensitivity of the MALDI-ToF MS subtyping module was 239/574 (42%) with 100% specificity. For the isolates harboring p019, the subtyping module showed a sensitivity of 97% (239/246) and a specificity of 100%. The subtyping module had poor sensitivity for the detection of blaKPC-positive Klebsiella isolates, albeit exhibiting excellent specificity. The poor sensitivity was a result of p019 being present in only 43% of the blaKPC-positive Klebsiella isolates.
Investigation of scan path optimization in improving proton pencil beam scanning continuous delivery
Liu, Chunbo , Beltran, Chris , Park, Chunjoo, Yaddanapudi, Sridhar , Tan, Jun , Furutani, Keith M. , Liang, Xiaoying , Tan, Jun , Shen, Jiajian , Furutani, Keith M , Liang, Xiaoying , Beltran, Chris J , Yaddanapudi, Sridhar , Shen, Jiajian , Lu, Bo, Tan, Jun

Physics in Medicine & Biology | September 13, 2023 | Volume: 68 | Issue: 19 | Pages: 195023

10.1088/1361-6560/acf98e | PMID 37703907 Get It

Abstract Objective . To investigate the impact of scan path optimization on the dose accuracy and beam delivery time (BDT) of proton pencil beam scanning in the dose-driven continuous scanning (DDCS). Approach . A diverse set of six clinical plans, representing various spot patterns and treatment sites, was used to evaluate the effectiveness of scan time optimization and scan length optimization. The DDCS dose discrepancy and BDT with optimized scan paths was compared to the default serpentine scan path. Main results . Both scan time optimization and scan path optimization were able to reduce the DDCS dose discrepancy compared to the default serpentine scan path. All plans, except for the layer repainting lung plan, achieved a 2%/2 mm gamma pass rate of over 99% and less than 1% PTV DVH root mean square error (RMSE) through scan path optimization. In the case of the layer repainting lung plan, when compared to the default serpentine scan path, the 2%/2 mm gamma pass rate showed improvements from 91.3% to 93.1% and 95.8%, while the PTV DVH RMSE decreased from 2.1% to 1.7% and 1.1% for scan time optimization and scan length optimization, respectively. Although scan time optimization resulted in shorter total scan times for all plans compared to the default scan path and scan length optimization tended to have longer total scan times. However, due to the short total scan times and their minimal contribution to the total BDT, the impact of scan path optimization on the total BDT was practically negligible. Significance . Both scan time optimization and scan length optimization proved to be effective in minimizing DDCS dose discrepancy. No definitive winner can be determined between these two optimization approaches. Both scan time and scan length optimization had minimal effect on the total BDT.
A high‐resolution cone beam computed tomography (HRCBCT) reconstruction framework for CBCT‐guided online adaptive therapy
Park, Justin C., Song, Bongyong , Lü, Bo , Tan, Jun , Parisi, Alessio , Denbeigh, Janet M. , Yaddanpudi, Sridhar, ByongSu, Choi, Kim, Jin Sung , Beltran, Chris , Yaddanapudi, Sridhar , Tan, Jun , Denbeigh, Janet, Choi, Byongsu , Beltran, Chris J , Parisi, Alessio , Yaddanapudi, Sridhar , Liang, Xiaoying , Choi, Byongsu, Furutani, Keith M. , Tan, Jun

Medical Physics | September 10, 2023 | Volume: 50 | Issue: 10 | Pages: 6490-6501

10.1002/mp.16734 | PMID 37690458 Get It

AbstractBackgroundKilo‐voltage cone‐beam computed tomography (CBCT) is a prevalent modality used for adaptive radiotherapy (ART) due to its compatibility with linear accelerators and ability to provide online imaging. However, the widely‐used Feldkamp‐Davis‐Kress (FDK) reconstruction algorithm has several limitations, including potential streak aliasing artifacts and elevated noise levels. Iterative reconstruction (IR) techniques, such as total variation (TV) minimization, dictionary‐based methods, and prior information‐based methods, have emerged as viable solutions to address these limitations and improve the quality and applicability of CBCT in ART.PurposeOne of the primary challenges in IR‐based techniques is finding the right balance between minimizing image noise and preserving image resolution. To overcome this challenge, we have developed a new reconstruction technique called high‐resolution CBCT (HRCBCT) that specifically focuses on improving image resolution while reducing noise levels.MethodsThe HRCBCT reconstruction technique builds upon the conventional IR approach, incorporating three components: the data fidelity term, the resolution preservation term, and the regularization term. The data fidelity term ensures alignment between reconstructed values and measured projection data, while the resolution preservation term exploits the high resolution of the initial Feldkamp‐Davis‐Kress (FDK) algorithm. The regularization term mitigates noise during the IR process. To enhance convergence and resolution at each iterative stage, we applied Iterative Filtered Backprojection (IFBP) to the data fidelity minimization process.ResultsWe evaluated the performance of the proposed HRCBCT algorithm using data from two physical phantoms and one head and neck patient. The HRCBCT algorithm outperformed all four different algorithms; FDK, Iterative Filtered Back Projection (IFBP), Compressed Sensing based Iterative Reconstruction (CSIR), and Prior Image Constrained Compressed Sensing (PICCS) methods in terms of resolution and noise reduction for all data sets. Line profiles across three line pairs of resolution revealed that the HRCBCT algorithm delivered the highest distinguishable line pairs compared to the other algorithms. Similarly, the Modulation Transfer Function (MTF) measurements, obtained from the tungsten wire insert on the CatPhan 600 physical phantom, showed a significant improvement with HRCBCT over traditional algorithms.ConclusionThe proposed HRCBCT algorithm offers a promising solution for enhancing CBCT image quality in adaptive radiotherapy settings. By addressing the challenges inherent in traditional IR methods, the algorithm delivers high‐definition CBCT images with improved resolution and reduced noise throughout each iterative step. Implementing the HR CBCT algorithm could significantly impact the accuracy of treatment planning during online adaptive therapy.
Trends in cardiovascular death related to mechanical complications of cardiac electronic devices in the United States from 1999 to 2020
Tan, Min Choon , Yeo, Yong Hao , San, Boon Jian , Tan, Jian Liang , Yeo, Yong Hao , Tan, Min C

International Journal of Arrhythmia | August 31, 2023 | Volume: 24 | Issue: 1 | Pages: No page available

10.1186/s42444-023-00101-6 Get It

Selecting Optimal Proton Pencil Beam Scanning Plan Parameters to Reduce Dose Discrepancy between Discrete Spot Plan and Continuous Scanning: A Proof-of-Concept Study
Beltran, Chris , Park, Chunjoo, Yaddanapudi, Sridhar , Tan, Jun , Furutani, Keith M. , Tan, Jun , Furutani, Keith M , Beltran, Chris J , Yaddanapudi, Sridhar , Liang, Xiaoying , Liu, Chunbo , Lu, Bo, Tan, Jun

Cancers | August 14, 2023 | Volume: 15 | Issue: 16 | Pages: 4084

10.3390/cancers15164084 | PMID 37627112 Get It

Pencil beam scanning delivered with continuous scanning has several advantages over conventional discrete spot scanning. Such advantages include improved beam delivery efficiency and reduced beam delivery time. However, a move dose is delivered between consecutive spots with continuous scanning, and current treatment planning systems do not take this into account. Therefore, continuous scanning and discrete spot plans have an inherent dose discrepancy. Using the operating parameters of the state-of-the-art particle therapy system, we conducted a proof-of-concept study in which we systematically generated 28 plans for cubic targets with different combinations of plan parameters and simulated the dose discrepancies between continuous scanning and a planned one. A nomograph to guide the selection of plan parameters was developed to reduce the dose discrepancy. The effectiveness of the nomograph was evaluated with two clinical cases (one prostate and one liver). Plans with parameters guided by the nomograph decreased dose discrepancy than those used standard plan parameters. Specifically, the 2%/2 mm gamma passing rate increased from 96.3% to 100% for the prostate case and from 97.8% to 99.7% for the liver case. The CTV DVH root mean square error decreased from 2.2% to 0.2% for the prostate case and from 1.8% to 0.9% for the liver case. The decreased dose discrepancy may allow the relaxing of the delivery constraint for some cases, leading to greater benefits in continuous scanning. Further investigation is warranted.
P915: TREATMENT PATTERNS AND CLINICAL OUTCOMES OF PATIENTS WITH MULTIPLE MYELOMA PREVIOUSLY TREATED WITH LENALIDOMIDE AND AN ANTI-CD38 MONOCLONAL ANTIBODY: FINDINGS FROM THE CONNECT MM DISEASE REGISTRY
Abonour, Rafat , Rifkin, Robert M. , Gasparetto, Christina, Durie, Brian G.M. , Terebelo, Howard R. , Narang, Mohit , Toomey, Kathleen, Tang, Yuexin , Dhanasiri, Sujith, Anand, Jasmeet, Yu, Edward, Marshall, Thomas, Liu, Liang , Ailawadhi, Sikander , Lee, Hans C. , Wagner, Lynne I. , Hardin, James W. , Jagannath, Sundar

HemaSphere | August 9, 2023 | Volume: 7 | Issue: S3 | Pages: e52503e2

10.1097/01.hs9.0000970564.52503.e2 Get It

Adverse events in cryoballoon ablation for pulmonary vein isolation: Insight from the Food and Drug Administration Manufacturer and User Facility Device Experience
Tan, Min Choon , Tan, Jian Liang , Lee, Wei Jun , Sorajja, Dan , Masry, Hicham El , Scott, Luis R. , Lee, Justin Z. , El Masry, Hicham , Tan, Min C , Srivathsan, Komandoor

Journal of Arrhythmia | July 24, 2023 | Volume: 39 | Issue: 5 | Pages: 784-789

10.1002/joa3.12898 | PMID 37799789 Get It

AbstractBackgroundReal‐world clinical data on the adverse events related to the use of cryoballoon catheter for pulmonary vein isolation remains limited.ObjectiveTo report and describe the adverse events related to the use of Artic Front cryoballoon catheters (Arctic Front, Arctic Front Advance, and Arctic Front Advance Pro) reported in the Food and Drug Administration's (FDA) Manufacturers and User Defined Experience (MAUDE) database.MethodsWe reviewed all the adverse events reported to the FDA MAUDE database over a 10.7‐year study period from January 01, 2011 to September 31, 2021. All events were independently reviewed by two physicians.ResultsDuring the study period, a total of 320 procedural‐related adverse events reported in the MAUDE database were identified. The most common adverse event was transient or persistent phrenic nerve palsy (PNP), accounting for 48% of all events. This was followed by cardiac perforation (15%), pulmonary vein stenosis (8%), transient ischemic attack or stroke (6%), vascular injury (4%), transient or persistent ST‐elevation myocardial infarction (3%), hemoptysis (2%), pericarditis (2%), and esophageal ulcer or fistula (1%). There were six reported intra‐procedural death events as a result of cardiac perforation.ConclusionThe two most common procedural adverse events associated with cryoballoon ablation were PNP and cardiac perforation. All cases of procedural mortality were due to cardiac perforation.
Feasibility of probe washing after stereotactic needle biopsy as a novel technique for developing cell lines and xenografts of H3 K27–altered diffuse midline gliomas
Zhang, Liang , Ge, Jizhi, Miller, Kai J. , Rechberger, Julian S. , Nesvick, Cody L. , Daniels, David J.

Journal of Neurosurgery: Pediatrics | July 15, 2023 | Volume: 32 | Issue: 4 | Pages: 413-420

10.3171/2023.5.peds22557 | PMID 37486856 Get It

H3 K27–altered diffuse midline gliomas (DMGs) are frequently biopsied to obtain tissue diagnosis, inform clinical decision-making, and determine clinical trial eligibility. Tissue yield from biopsies is typically low, leaving little material available for research. To advance understanding of disease biology and promote preclinical testing of novel therapeutics, collecting viable cellular material from treatment-naive tumors is of paramount importance. Here, the authors report the feasibility of a practicable technique for creating DMG cell lines and patient-derived xenografts (PDXs) without the need for additional biopsy specimens. Tumor cells are obtained by probe washing immediately after completion of biopsy. Wash fluid is collected, and viable cells are expanded in vitro. Cultured cells are used to establish PDX rodent models. A total of 5 patient samples were collected by this technique. Viable tumor cells were obtained from 3 of the 5 samples, and cell lines suitable for experiments were obtained within 6–8 months. Orthotopic implantation and flank engraftment was successful in 1 of the 3 established cell lines. Animals harboring intracranial tumors were euthanized due to disease burden 6–7 months after stereotactic injection. Flank tumors formed within 4–5 months and were serially passaged. Molecular and tissue analyses confirmed retention of H3 K27M expression and loss of H3 K27me3 in all cell lines and PDXs.
Impact of obesity on catheter ablation of ventricular tachycardia: In‐hospital and 30‐day outcomes
Tan, Min Choon , Yeo, Yong Hao , Ang, Qi Xuan , Tan, Jian Liang , Lee, Justin Z. , Rattanawong, Pattara , Yeo, Yong Hao , Tan, Min C , Tan, Bryan E‐Xin , Rattanawong, Pattara

Journal of Arrhythmia | July 5, 2023 | Volume: 39 | Issue: 4 | Pages: 672-675

10.1002/joa3.12892 | PMID 37560290 Get It

AbstractBackgroundEvidence on the impact of obesity on catheter ablation for ventricular tachycardia (VT) is scarce.Method and ResultsWe queried the Nationwide Readmissions Database to determine the hospital outcomes and procedural complications of VT ablation among the obese and nonobese populations. Obesity was associated with a more prolonged length of stay (p < .01), higher cost of hospitalization (p < .01), and higher rates of pericardial effusion or hemopericardium (p = .05) and vascular complications (p = .05). There was no significant difference in early mortality, 30‐day readmissions, and other procedural complications.ConclusionVT ablation could be performed relatively safely among patients with obesity.