Abstract Introduction Implant sonication is useful for recovery of periprosthetic joint infection (PJI) pathogens in culture, but exact cutoff points for definition of clinically significant sonicate fluid culture results vary from study to study. The aim of this study was to define ideal sonicate fluid culture cutoff points for PJI diagnosis. Methods Sonicate fluid cultures from hip and knee prosthesis components removed between February 2007 and December 2020 were studied. Prosthesis components were placed in solid containers in the operating room; in the clinical microbiology laboratory, 400 mL Ringer's solution was added, and containers subjected to vortexing, sonication and then vortexing, followed by centrifugation. Concentrated sonicate fluid was plated on aerobic and anaerobic solid media, and culture results reported semiquantitatively, as no growth, <20, 20–50, 51–100, or >100 CFU/10 mL sonicate fluid. Sonicate cultures from cement spacers and cultures yielding more than 1 microorganism were excluded. Sensitivity and specificity of each cutoff point was evaluated. Results A total of 1448 sonicate fluid cultures were evaluated, 68% from knees and 32% from hips. PJI was present in 644 (44%) cases. Sensitivity of sonicate culture was 75.0% at <20 CFU/10 mL, 55.3% at ≥20 CFU/10 mL, 46.9% at >51 CFU/10 mL, and 39.8% at >100 CFU/10 mL. Specificity was 78.2%, 99.8%, 100%, and 100%, at the 4 cutoff points, respectively. Conclusions A cutoff point for sonicate fluid culture positivity of ≥20 CFU/10 mL is suitable for PJI diagnosis.
Poor Sensitivity of the MALDI Biotyper® MBT Subtyping Module for Detection of Klebsiella pneumoniae Carbapenemase (KPC) in Klebsiella Species
Rapid detection of Klebsiella pneumoniae carbapenemase (KPC) in the Klebsiella species is desirable. The MALDI Biotyper® MBT Subtyping Module (Bruker Daltonics) uses an algorithm that detects a peak at ~11,109 m/z corresponding to a protein encoded by the p019 gene to detect KPC simultaneously with organism identification by a matrix-assisted laser desorption ionization–time-of-flight mass spectrometry (MALDI-ToF MS). Here, the subtyping module was evaluated using 795 clinical Klebsiella isolates, with whole genome sequences used to assess for blaKPC and p019. For the isolates identified as KPC positive by sequencing, the overall sensitivity of the MALDI-ToF MS subtyping module was 239/574 (42%) with 100% specificity. For the isolates harboring p019, the subtyping module showed a sensitivity of 97% (239/246) and a specificity of 100%. The subtyping module had poor sensitivity for the detection of blaKPC-positive Klebsiella isolates, albeit exhibiting excellent specificity. The poor sensitivity was a result of p019 being present in only 43% of the blaKPC-positive Klebsiella isolates.