Citations

Mayo Clinic

Clear

23 citation(s) found for "Fagan, Andrew".

Subjective and objective burden on providers from a multicenter app-based study of patients with cirrhosis and caregivers
Shaw, Jawaid , Acharya, Chathur , Albhaisi, Somaya , Fagan, Andrew , McGeorge, Sara , White, Melanie B. , Lachar, Jatinder, Olofson, Amy , Bergstrom, Lori , Kamath, Patrick S. , Bajaj, Jasmohan S. , Olson, Jessica, Kamath, Patrick S , Bajaj, Jasmohan S , Albhaisi, Somaya , Shaw, Jawaid , White, Melanie B. , Olson, Jessica

Hepatology Communications | January 27, 2023 | Volume: 7 | Issue: 2 | Pages: e0030-e0030

10.1097/hc9.0000000000000030 | PMID 36706194 Get It

Background: App-based technologies could enhance patient and caregiver communication and provide alerts that potentially reducing readmissions. However, the burden of App alerts needs to be optimized to reduce provider burnout. Aim: The purpose of this study was to determine subjective and objective burden of using the Patient Buddy App, a health information technology (HIT) on providers in a randomized multicenter trial, who completed a semi-quantitative Likert scale survey regarding training procedures, data and privacy concerns, follow-up details, and technical support. This randomized multicenter trial recruits cirrhosis inpatients and their caregivers, and randomizes them into standard-of-care, HIT (communication only via App) and HIT+visits (App+phone calls/visits) for 30 days after discharge. The alerts are monitored by providers through a central iPad. The reason(s) and number of alerts were recorded as the objective burden. A total of 1442 messages were sent as alerts from the 103 dyads (patient + caregiver) (n=206) randomized to HIT arms. The most common messages related to Hepatic Encephalopathy (HE) (high or low bowel movement=50% or orientation tests=37%). Twelve providers completed the surveys reflecting the following themes—92% and 100%, felt adequately trained and confident about educating the patients and caregivers before roll out of App and had no concerns related to data and privacy; 70%, felt that appropriate time was spent on pursuing reason for data not being logged; 60% each, had issues with availability of adequate technical support and connectivity. Conclusion: The Patient Buddy App randomized multicenter trial till date shows an overall favorable rating regarding training procedures/education, privacy concerns, and ease of message follow-up, from providers. However, it is important to gauge and address subjective and objective burdens of monitoring human resources in current and future HIT studies to avoid burnout and to ensure successful study completion.
Minimizing magnetic resonance image geometric distortion at 7 Tesla for frameless presurgical planning using skin‐adhered fiducials
Kirby, Krystal , Koons, Emily K. , Welker, Kirk M. , Kirby, Krystal M, Fagan, Andrew

Medical Physics | October 27, 2022 | Volume: 50 | Issue: 2 | Pages: 694-701

10.1002/mp.16035 | PMID 36301228 Get It

AbstractBackground7T MRI offers significant benefits to spatial and contrast resolution compared to lower field strengths. This superior image quality can help better delineate targets in stereotactic neurosurgical procedures; however, the potential for increased geometric distortions at 7T has impaired its widespread use for these applications. Image geometric distortions can be due to distortions of B0 arising from tissue magnetic susceptibility effects or inherent field inhomogeneities, and nonlinearity of the magnetic field gradients.PurposeThe purpose of this study was to investigate the use of 7T MRI for neurosurgical frameless stereotactic navigation procedures. Image geometric distortions at the skin surface in 7T images were minimized and compared to results from clinical 3T frameless imaging protocols.MethodsA 3D‐printed grid phantom filled with oil was designed to perform a fine calibration of the 7T imaging gradients, and an oil‐filled head phantom with internal targets was used to determine ground truth (from computed tomography [CT]) positioning errors. Three volunteers and the head phantom were imaged consecutively at 3T and 7T. Ten skin‐adhesive fiducial markers were placed on each subject's exposed skin surface at standard clinical placement locations for frameless procedures. Imaging sequences included MPRAGE (three bandwidths at 7T: 400, 690, and 1020 Hz/pixel, and one at 3T: 400 Hz/pixel), T2 SPACE, and T2 SPACE FLAIR acquisitions. An additional GRE field map was acquired on both scanners using a multi‐echo GRE sequence. Custom Matlab code was used to perform additional distortion correction of the images using the unwrapped field maps. Fiducial localization was performed with 3D Slicer, with absolute fiducial positioning errors determined in phantom experiments following rigid registration to the CT images. For human experiments, 3T and 7T images were registered and relative differences in fiducial locations were compared using two‐tailed paired t‐tests.ResultsPhantom measurements at 7T yielded gradient distance scaling errors of 1.1%, 2.2%, and 1.0% along the x‐, y‐, and z‐axes, respectively. These system miscalibrations were traced back to phantom manufacturing deviations in the sphericity of the vendor's gradient calibration phantom. Correction factors along each gradient axis were applied, and afterward, geometric distortions of less than 1 mm were obtained in the 7T MR head phantom images for the 1020 Hz/pixel bandwidth MPRAGE sequence. For the human subjects, four fiducial locations were excluded from the analysis due to patient positioning differences. Differences between 3T and 7T MPRAGE with low/medium/high bandwidth were 2.2 /2.6/2.3 mm, respectively, before the correction, reducing to 1.6/1.3/1.0 mm after the correction (p < 0.001). T2 SPACE and T2 SPACE FLAIR yielded a similar pattern when the correction was applied, decreasing from 2.1 to 0.8 mm, and 2.6 to 1.0 mm, respectively.Conclusions7T MRI can be used to perform frameless presurgical planning with skin‐adhesive fiducials. Geometric distortions can be reduced to a clinically relevant level (errors < ∼1 mm) with no significant susceptibility‐related distortions, by using high receiver bandwidth, ensuring gradients are properly calibrated, and placing skin fiducials in areas where distortions from patient positioning are minimal.
Cardiac Magnetic Resonance at 3.0 T in Patients With C282Y Homozygous Hereditary Hemochromatosis
Byrne, Danielle, Walsh, John P., Murphy, Ross T., McMorrow, Jason, Fagan, Andrew J., Poetrzyk, Aneta Kecler, Durand, Michael E., Norris, Suzanne, McKiernan, Susan, King, Gerard, Meaney, James F., Daly, Caroline, Byrne, Danielle, Walsh, John P., Murphy, Ross T., McMorrow, Jason, Fagan, Andrew J., Poetrzyk, Aneta Kecler, Durand, Michael E., Norris, Suzanne, McKiernan, Susan, King, Gerard, Meaney, James F., Daly, Caroline

Journal of Thoracic Imaging | April 15, 2022 | Volume: 37 | Issue: 5 | Pages: 300-306

10.1097/rti.0000000000000645 | PMID 35426858 Get It

Background: Iron-overload cardiomyopathy initially manifests with diastolic dysfunction and can progress to dilated cardiomyopathy if untreated. Previous studies have shown that patients with primary and secondary hemochromatosis can have subclinical left ventricle dysfunction with abnormalities on strain imaging. This study aimed to evaluate the relationship between cardiac T2* values and myocardial-wall strain in patients with hereditary hemochromatosis (HH) at the time of diagnosis and after a course of venesection treatment. Materials and Methods: Baseline cardiac magnetic resonance (CMR) at 3 T was performed in 19 patients with newly diagnosed HH with elevated serum ferritin levels and repeated after a course of treatment with venesection. Quantitative T2* mapping and strain analysis were performed offline using dedicated relaxometry fitting and feature-tracking software. Results: The majority (84%) of patients had normal baseline myocardial T2* values (mean 19.3 ms, range 8.9 to 31.2 ms), which improved significantly after venesection (mean 24.1 ms, range 11 to 38.1 ms) (P=0.021). Mean global radial strain significantly improved from 25.0 (range: 15.6 to 32.9) to 28.3 (range: 19.8 to 35.8) (P=0.001) and mean global circumferential strain improved, decreasing from −15.7 (range: −11.1 to −19.2) to −17.1 (range: −13.0 to −20.1) (P=0.001). Conclusion: Patients with HH may have normal T2* values in the presence of subclinical left ventricle dysfunction, which can be detected by abnormal radial and circumferential strain. As strain imaging improves following venesection in HH, it may serve as a useful biomarker to guide treatment.
The development of ultra–high field MRI guidance technology for neuronavigation
Rusheen, Aaron E., Goyal, Abhinav, Owen, Robert L., Berning, Elise M., Bothun, Dane T., Giblon, Rachel E., Blaha, Charles D., Welker, Kirk M., Huston, John, Bennet, Kevin E., Oh, Yoonbae, Fagan, Andrew J., Lee, Kendall H., Giblon, Rachel , Rusheen, Aaron E., Goyal, Abhinav, Owen, Robert L., Berning, Elise M., Bothun, Dane T., Blaha, Charles D., Welker, Kirk M., Huston, John, Bennet, Kevin E., Oh, Yoonbae, Fagan, Andrew J., Lee, Kendall H.

Journal of Neurosurgery | March 25, 2022 | Volume: 137 | Issue: 5 | Pages: 1265-1277

10.3171/2021.11.jns211078 | PMID 35334465 Get It

OBJECTIVE Magnetic resonance imaging at 7T offers improved image spatial and contrast resolution for visualization of small brain nuclei targeted in neuromodulation. However, greater image geometric distortion and a lack of compatible instrumentation preclude implementation. In this report, the authors detail the development of a stereotactic image localizer and accompanying imaging sequences designed to mitigate geometric distortion, enabling accurate image registration and surgical planning of basal ganglia nuclei. METHODS Magnetization-prepared rapid acquisition with gradient echo (MPRAGE), fast gray matter acquisition T1 inversion recovery (FGATIR), T2-weighted, and T2*-weighted sequences were optimized for 7T in 9 human subjects to visualize basal ganglia nuclei, minimize image distortion, and maximize target contrast-to-noise and signal-to-noise ratios. Extracranial spatial distortions were mapped to develop a skull-contoured image localizer embedded with spherical silicone fiducials for improved MR image registration and target guidance. Surgical plan accuracy testing was initially performed in a custom-developed MRI phantom (n = 5 phantom studies) and finally in a human trial. RESULTS MPRAGE and T2*-weighted sequences had the best measures among global measures of image quality (3.8/4, p < 0.0001; and 3.7/4, p = 0.0002, respectively). Among basal ganglia nuclei, FGATIR outperformed MPRAGE for globus pallidus externus (GPe) visualization (2.67/4 vs 1.78/4, p = 0.008), and FGATIR, T2-weighted imaging, and T2*-weighted imaging outperformed MPRAGE for substantia nigra visualization (1.44/4 vs 2.56/4, p = 0.04; vs 2.56/4, p = 0.04; vs 2.67/4, p = 0.003). Extracranial distortion was lower in the head’s midregion compared with the base and apex ( 1.17–1.33 mm; MPRAGE and FGATIR, p < 0.0001; T2-weighted imaging, p > 0.05; and T2*-weighted imaging, p = 0.013). Fiducial placement on the localizer in low distortion areas improved image registration (fiducial registration error, 0.79–1.19 mm; p < 0.0001) and targeting accuracy (target registration error, 0.60–1.09 mm; p = 0.04). Custom surgical software and the refined image localizer enabled successful surgical planning in a human trial (fiducial registration error = 1.0 mm). CONCLUSIONS A skull-contoured image localizer that accounts for image distortion is necessary to enable high-accuracy 7T imaging–guided targeting for surgical neuromodulation. These results may enable improved clinical efficacy for the treatment of neurological disease.
Admission Urinary and Serum Metabolites Predict Renal Outcomes in Hospitalized Patients With Cirrhosis
Bajaj, Jasmohan S. , García‐Tsao, Guadalupe , Reddy, K. Rajender , O’Leary, Jacqueline G. , Vargas, Hugo E. , Kamath, Patrick S. , Subramanian, Ram, Thuluvath, Paul J. , Fagan, Andrew , Sehrawat, Tejasav S. , Rodríguez, Randolph de la Rosa, Sehrawat, Tejasav S , Wong, Florence , Vargas, Hugo E , García–Tsao, Guadalupe , Lai, Jennifer C. , Tandon, Puneeta , Thacker, Leroy R. , Wong, Florence

Hepatology | May 18, 2021 | Volume: 74 | Issue: 5 | Pages: 2699-2713

10.1002/hep.31907 | PMID 34002868 Get It

Background and Aims Acute kidney injury (AKI) has a poor prognosis in cirrhosis. Given the variability of creatinine, the prediction of AKI and dialysis by other markers is needed. The aim of this study is to determine the role of serum and urine metabolomics in the prediction of AKI and dialysis in an inpatient cirrhosis cohort. Approach and Results Inpatients with cirrhosis from 11 North American Consortium of End‐stage Liver Disease centers who provided admission serum/urine when they were AKI and dialysis‐free were included. Analysis of covariance adjusted for demographics, infection, and cirrhosis severity was performed to identify metabolites that differed among patients (1) who developed AKI or not; (2) required dialysis or not; and/pr (3) within AKI subgroups who needed dialysis or not. We performed random forest and AUC analyses to identify specific metabolite(s) associated with outcomes. Logistic regression with clinical variables with/without metabolites was performed. A total of 602 patients gave serum (218 developed AKI, 80 needed dialysis) and 435 gave urine (164 developed AKI, 61 needed dialysis). For AKI prediction, clinical factor–adjusted AUC was 0.91 for serum and 0.88 for urine. Major metabolites such as uremic toxins (2,3‐dihydroxy‐5‐methylthio‐4‐pentenoic acid [DMTPA], N2N2dimethylguanosine, uridine/pseudouridine) and tryptophan/tyrosine metabolites (kynunerate, 8‐methoxykyunerate, quinolinate) were higher in patients who developed AKI. For dialysis prediction, clinical factor–adjusted AUC was 0.93 for serum and 0.91 for urine. Similar metabolites as AKI were altered here. For dialysis prediction in those with AKI, the AUC was 0.81 and 0.79 for serum/urine. Lower branched‐chain amino‐acid (BCAA) metabolites but higher cysteine, tryptophan, glutamate, and DMTPA were seen in patients with AKI needing dialysis. Serum/urine metabolites were additive to clinical variables for all outcomes. Conclusions Specific admission urinary and serum metabolites were significantly additive to clinical variables to predict AKI development and dialysis initiation in inpatients with cirrhosis. These observations can potentially facilitate earlier initiation of renoprotective measures.
Cirrhosis Is Associated With High Mortality and Readmissions Over 90 Days Regardless of COVID‐19: A Multicenter Cohort
Bajaj, Jasmohan S. , García‐Tsao, Guadalupe , Wong, Florence , Biggins, Scott W. , Kamath, Patrick S. , McGeorge, Sara , Chew, Michael, Pearson, Meredith , Shaw, Jawaid , Kalluri, Anita , Fagan, Andrew , Olofson, Amy , Rodríguez, Randolph de la Rosa, Reddy, K. Rajender , Wong, Florence , García–Tsao, Guadalupe , Moini, Maryam

Liver Transplantation | January 15, 2021 | Volume: 27 | Issue: 9 | Pages: 1343-1347

10.1002/lt.25981 | PMID 33427401 Get It

7T MR Thermometry technique for validation of system‐predicted SAR with a home‐built radiofrequency wrist coil
Fagan, Andrew , Jacobs, Paul , Hulshizer, Thomas C., Rossman, Phillip J. , Frick, Matthew A., Amrami, Kimberly K. , Felmlee, Joel P. , Jacobs, Paul S, Fagan, Andrew J

Medical Physics | December 10, 2020 | Volume: 48 | Issue: 2 | Pages: 781-790

10.1002/mp.14641 | PMID 33294999 Get It

PurposeA 7T magnetic resonance thermometry (MRT) technique was developed to validate the conversion factor between the system‐measured transmitted radiofrequency (RF) power into a home‐built RF wrist coil with the system‐predicted SAR value. The conversion factor for a new RF coil developed for ultra high magnetic field MRI systems is used to ensure that regulatory limits on RF energy deposition in tissue, specifically the local 10g‐averaged specific absorption rate (SAR10g), are not exceeded. MRT can be used to validate this factor by ensuring that MRT‐measured SAR values do not exceed those predicted by the system.MethodsA 14‐cm diameter high‐pass birdcage RF coil was built to image the wrist at 7T. A high spatial and temporal resolution dual‐echo gradient echo MRT technique, incorporating quasi‐simultaneous RF‐induced heating and temperature change measurements using the proton resonance frequency method, was developed. The technique allowed for high‐temperature resolution measurements (~±0.1°C) to be performed every 20 s over a 4‐min heating period, with high spatial resolution (2.56 mm3 voxel size) and avoiding phase discontinuities arising from severe magnetic susceptibility‐induced B0 inhomogeneities. Magnetic resonance thermometry was performed on a phantom made from polyvinylpyrrolidone to mimic the dielectric properties of muscle tissue at 297.2 MHz. Temperature changes measured with MRT and four fiber optic temperature sensors embedded in the phantom were compared. Electromagnetic simulations of the coil and phantom were developed and validated via comparison of simulated and measured B1+ maps in the phantom. The position of maximum SAR within the coil was determined from simulations, and MRT was performed within a wrist‐sized piece of meat positioned at that SAR hotspot location. MRT‐measured and system‐predicted SAR values for the phantom and meat were compared.ResultsTemperature change measurements from MRT matched closely to those from the fiber optic temperature sensors. The simulations were validated via close correlation between the simulated and MRT‐measured B1+ and SAR maps. Using a coil conversion factor of 2 kg−1, MRT‐measured point‐SAR values did not exceed the system‐predicted SAR10g in either the uniform phantom or in the piece of meat mimicking the wrist located at the SAR hotspot location.ConclusionsA highly accurate MRT technique with high spatial and temporal resolution was developed. This technique can be used to ensure that system‐predicted SAR values are not exceeded in practice, thereby providing independent validation of SAR levels delivered by a newly built RF wrist coil. The MRT technique is readily generalizable to perform safety evaluations for other RF coils at 7T.
7T MR Safety
Fagan, Andrew , Bitz, Andreas K., Björkman‐Burtscher, Isabella M. , Collins, Christopher M. , Kimbrell, Vera , Raaijmakers, Alexander , Metzger, Gregory J. , Fagan, Andrew J

Journal of Magnetic Resonance Imaging | August 24, 2020 | Volume: 53 | Issue: 2 | Pages: 333-346

10.1002/jmri.27319 | PMID 32830900 Get It

Magnetic resonance imaging and spectroscopy (MRI/MRS) at 7T represents an exciting advance in MR technology, with intriguing possibilities to enhance image spatial, spectral, and contrast resolution. To ensure the safe use of this technology while still harnessing its potential, clinical staff and researchers need to be cognizant of some safety concerns arising from the increased magnetic field strength and higher Larmor frequency. The higher static magnetic fields give rise to enhanced transient bioeffects and an increased risk of adverse incidents related to electrically conductive implants. Many technical challenges remain and the continuing rapid pace of development of 7T MRI/MRS is likely to present further challenges to ensuring safety of this technology in the years ahead. The recent regulatory clearance for clinical diagnostic imaging at 7T will likely increase the installed base of 7T systems, particularly in hospital environments with little prior ultrahigh‐field MR experience. Informed risk/benefit analyses will be required, particularly where implant manufacturer‐published 7T safety guidelines for implants are unavailable. On behalf of the International Society for Magnetic Resonance in Medicine, the aim of this article is to provide a reference document to assist institutions developing local institutional policies and procedures that are specific to the safe operation of 7T MRI/MRS. Details of current 7T technology and the physics underpinning its functionality are reviewed, with the aim of supporting efforts to expand the use of 7T MRI/MRS in both research and clinical environments. Current gaps in knowledge are also identified, where additional research and development are required. Level of Evidence 5 Technical Efficacy 2 J. MAGN. RESON. IMAGING 2021;53:333–346.
Multimodal Breast Phantoms for Microwave, Ultrasound, Mammography, Magnetic Resonance and Computed Tomography Imaging
Ruvio, Giuseppe , Solimene, Raffaele , Cuccaro, Antonio , Fiaschetti, Gaia, Fagan, Andrew , Cournane, Seán , Cooke, Jennie , Ammann, Max J. , Vasquez, J. A. Tobón , Browne, Jacinta E. , Fagan, Andrew J , Tobon, Jorge , Browne, Jacinta

Sensors | April 23, 2020 | Volume: 20 | Issue: 8 | Pages: 2400

10.3390/s20082400 | PMID 32340281 Get It

The aim of this work was to develop multimodal anthropomorphic breast phantoms suitable for evaluating the imaging performance of a recently-introduced Microwave Imaging (MWI) technique in comparison to the established diagnostic imaging modalities of Magnetic Resonance Imaging (MRI), Ultrasound (US), mammography and Computed Tomography (CT). MWI is an emerging technique with significant potential to supplement established imaging techniques to improve diagnostic confidence for breast cancer detection. To date, numerical simulations have been used to assess the different MWI scanning and image reconstruction algorithms in current use, while only a few clinical trials have been conducted. To bridge the gap between the numerical simulation environment and a more realistic diagnostic scenario, anthropomorphic phantoms which mimic breast tissues in terms of their heterogeneity, anatomy, morphology, and mechanical and dielectric characteristics, may be used. Key in this regard is achieving realism in the imaging appearance of the different healthy and pathologic tissue types for each of the modalities, taking into consideration the differing imaging and contrast mechanisms for each modality. Suitable phantoms can thus be used by radiologists to correlate image findings between the emerging MWI technique and the more familiar images generated by the conventional modalities. Two phantoms were developed in this study, representing difficult-to-image and easy-to-image patients: the former contained a complex boundary between the mammary fat and fibroglandular tissues, extracted from real patient MRI datasets, while the latter contained a simpler and less morphologically accurate interface. Both phantoms were otherwise identical, with tissue-mimicking materials (TMMs) developed to mimic skin, subcutaneous fat, fibroglandular tissue, tumor and pectoral muscle. The phantoms’ construction used non-toxic materials, and they were inexpensive and relatively easy to manufacture. Both phantoms were scanned using conventional modalities (MRI, US, mammography and CT) and a recently introduced MWI radar detection procedure called in-coherent Multiple Signal Classification (I-MUSIC). Clinically realistic artifact-free images of the anthropomorphic breast phantoms were obtained using the conventional imaging techniques as well as the emerging technique of MWI.
Image Artifact Management for Clinical Magnetic Resonance Imaging on a 7 T Scanner Using Single-Channel Radiofrequency Transmit Mode
Fagan, Andrew , Welker, Kirk M. , Amrami, Kimberly K. , Frick, Matthew A., Watson, Robert E. , Kollasch, Peter , Chebrolu, Venkata V. , Felmlee, Joel P. , Fagan, Andrew J

Investigative Radiology | September 10, 2019 | Volume: 54 | Issue: 12 | Pages: 781-791

10.1097/rli.0000000000000598 | PMID 31503079 Get It

Objectives The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. Materials and Methods Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 + and B1 − inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. Results Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. Conclusions Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.