Citations

Mayo Clinic

Clear

248 citation(s) found for "O, Hodge David".

Mortality After Magnetic Resonance Imaging of the Brain in Patients With Cardiovascular Implantable Devices
Padmanabhan, Deepak , Jondal, Mary Lou, Hodge, David O. , Mehta, Ramila A. , Acker, Nancy G., Dalzell, Connie, Asirvatham, Samuel J. , Cha, Yong‐Mei , Felmlee, Joel P. , Watson, Robert E. , Friedman, Paul A. , Jondal, Mary L, Dalzell, Connie M, Kapa, Suraj , Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | January 10, 2018 | Volume: 11 | Issue: 1 | Pages: No page available

10.1161/circep.117.005480 | PMID 29321191 Get It

Background: Use of magnetic resonance imaging (MRI) brain is restricted in patients with cardiovascular implantable electronic devices (CIEDs). We proposed to determine whether mortality difference exists for patients with non–MRI-conditional CIEDs undergoing brain MRI compared with controls. Methods and Results: Retrospective analysis of prospectively collected data was performed to compare all-cause mortality in patients with CIEDs undergoing brain MRI (CIED-MRI) with 3 control groups matched for age, sex, imaging year, and type of CIED: (1) no CIED, brain MRI (no–CIED-MRI); (2) CIED, brain computerized tomography (CT) scan (CIED-CT); and (3) no CIED, brain CT (no–CIED-CT). The primary outcome was a significant difference ( P <0.05) between estimated mortality rates. Secondary outcomes were changes in device function before and after brain MRI. The estimated all-cause mortality at 5 years for the CIED-MRI group [mean age (±SD), 68.2 years (15.3 years); 61.2% men] was not significantly different from patients who underwent CT with or without a device (CIED-CT group: hazard ratio, 0.814; 95% confidence interval, 0.593–1.117; P =0.2; no–CIED-CT group: hazard ratio, 1.149; 95% confidence interval, 0.818–1.613; P =0.4). There was a significant increase in mortality between CIED-MRI and no–CIED-MRI groups (hazard ratio, 1.463; 95% confidence interval, 1.019–2.099; P =0.04). Conclusions: Brain MRI in patients with CIEDs does not carry an increased mortality risk compared with brain CT and can be performed with adherence to appropriate procedural protocols.
Racial disparity in utilization of therapeutic modalities among multiple myeloma patients: a SEER‐medicare analysis
Ailawadhi, Sikander , Frank, Ryan D. , Advani, Pooja , Swaika, Abhisek, Temkit, M’hamed , Menghani, Richa, Sharma, Mayank , Meghji, Zahara, Paulus, Shumail M., Khera, Nandita , Hashmi, Shahrukh K. , Paulus, Aneel , Kakar, Tanya Singh, Hodge, David O. , Vizzini, Michael, Colón‐Otero, Gerardo , Chanan‐Khan, Asher , Paulus, Shumail, Kakar, Tanya S, Colibaseanu, Dorin T, Vizzini, Michael R., Chanan-Khan, Asher A., Ailawadhi, Sikander , Paulus, Aneel , Colibaseanu, Dorin , Roy, Vivek

Cancer Medicine | November 3, 2017 | Volume: 6 | Issue: 12 | Pages: 2876-2885

10.1002/cam4.1246 | PMID 29105343 Get It

AbstractOutcomes have improved considerably in multiple myeloma (MM), but disparities among racial‐ethnic groups exist. Differences in utilization of novel therapeutics are likely contributing factors. We explored such differences from the SEER‐Medicare database. A utilization analysis of lenalidomide, thalidomide, bortezomib, and stem cell transplant (SCT) was performed for patients diagnosed with MM between 2007 and 2009, including use over time, use by race, time‐dependent trends for each racial subgroup, and survival analysis. A total of 5338 MM patients were included with median 2.4‐year follow‐up. Within the first year of MM diagnosis, utilization of lenalidomide, bortezomib, SCT, and more than one novel agent increased over time while utilization of thalidomide decreased. There was significantly lower utilization of lenalidomide among African‐Americans (P < 0.01), higher thalidomide use among Hispanics and Asians (P < 0.01), and lower bortezomib use among Asians (P < 0.01). Hispanics had the highest median number of days to first dose of bortezomib (P = 0.02) and the lowest utilization of SCT (P < 0.01). Hispanics and Asians were the only groups without notable increases in lenalidomide and bortezomib use, respectively. SCT utilization increased over time for all except African‐Americans. SCT use within the first year after diagnosis was associated with better overall survival (HR 0.52; 95% CI: 0.4–0.68), while bortezomib use was associated with inferior survival (HR 1.14; 95% CI 1.02–1.28). We noted considerable variability in MM therapeutics utilization with seeming inequity for racial‐ethnic minorities. These trends should be considered to eliminate drug access and utilization disparities and achieve equitable benefit of therapeutic advances across all races.
Mortality and Cerebrovascular Events After Heart Rhythm Disorder Management Procedures
Lee, Justin Z. , Ling, Jayna, Diehl, Nancy N. , Hodge, David O. , Padmanabhan, Deepak , Killu, Ammar M. , Madhavan, Malini , Cha, Yong‐Mei , Deshmukh, Abhishek , Shen, Win-Kuang, Friedman, Paul A. , Munger, Thomas M. , Asirvatham, Samuel J. , Packer, Douglas L. , Mulpuru, Siva K. , Kapa, Suraj , Asirvatham, Samuel J , Noseworthy, Peter A. , McLeod, Christopher J. , Srivathsan, Komandoor , Kusumoto, Fred

Circulation | October 18, 2017 | Volume: 137 | Issue: 1 | Pages: 24-33

10.1161/circulationaha.117.030523 | PMID 29046320 Get It

Background: Recognition of rates and causes of hard, patient-centered outcomes of death and cerebrovascular events (CVEs) after heart rhythm disorder management (HRDM) procedures is an essential step for the development of quality improvement programs in electrophysiology laboratories. Our primary aim was to assess and characterize death and CVEs (stroke or transient ischemic attack) after HRDM procedures over a 17-year period. Methods: We performed a retrospective cohort study of all patients undergoing HRDM procedures between January 2000 and November 2016 at the Mayo Clinic. Patients from all 3 tertiary academic centers (Rochester, Phoenix, and Jacksonville) were included in the study. All in-hospital deaths and CVEs after HRDM procedures were identified and were further characterized as directly or indirectly related to the HRDM procedure. Subgroup analysis of death and CVE rates was performed for ablation, device implantation, electrophysiology study, lead extraction, and defibrillation threshold testing procedures. Results: A total of 48 913 patients (age, 65.7±6.6 years; 64% male) who underwent a total of 62 065 HRDM procedures were included in the study. The overall mortality and CVE rates in the cohort were 0.36% (95% confidence interval [CI], 0.31–0.42) and 0.12% (95% CI, 0.09–0.16), respectively. Patients undergoing lead extraction had the highest overall mortality rate at 1.9% (95% CI, 1.34–2.61) and CVE rate at 0.62% (95% CI, 0.32–1.07). Among patients undergoing HRDM procedures, 48% of deaths directly related to the HDRM procedure were among patients undergoing device implantation procedures. Overall, cardiac tamponade was the most frequent direct cause of death (40%), and infection was the most common indirect cause of death (29%). The overall 30-day mortality rate was 0.76%, with the highest being in lead extraction procedures (3.08%), followed by device implantation procedures (0.94%). Conclusions: Half of the deaths directly related to an HRDM procedure were among the patients undergoing device implantation procedures, with cardiac tamponade being the most common cause of death. This highlights the importance of the development of protocols for the quick identification and management of cardiac tamponade even in procedures typically believed to be lower risk such as device implantation.
Effect of Body Position on Epsicleral Venous Pressure in Healthy Subjects
Arora, Nitika, McLaren, Jay W. , Hodge, David O. , Sit, Arthur J. , Sit, Arthur J

Investigative Opthalmology & Visual Science | October 6, 2017 | Volume: 58 | Issue: 12 | Pages: 5151

10.1167/iovs.17-22154 | PMID 28986593 Get It

Super-response to cardiac resynchronization therapy reduces appropriate implantable cardioverter defibrillator therapy
Killu, Ammar M. , Mazo, Anna, Grupper, Avishay , Madhavan, Malini , Webster, Tracy L., Brooke, Kelly L., Hodge, David O. , Asirvatham, Samuel J. , Friedman, Paul A. , Glikson, Michael , Cha, Yong‐Mei , Webster, Tracy, Asirvatham, Samuel J , Glikson, Michael

EP Europace | August 4, 2017 | Volume: 20 | Issue: 8 | Pages: 1303-1311

10.1093/europace/eux235 | PMID 29016821 Get It

Analysis of a Physician-led, Team-based Care Model for the Treatment of Glaucoma
Winkler, Nelson S., Damento, Gena M., Khanna, Sunil S., Hodge, David O. , Khanna, Cheryl L.

Journal of Glaucoma | June 14, 2017 | Volume: 26 | Issue: 8 | Pages: 702-707

10.1097/ijg.0000000000000689 | PMID 28617721 Get It

Purpose: To determine the effect of a protocol for a new physician-led, team-based glaucoma care model implemented in 2008 at Mayo Clinic’s campus in Rochester, Minnesota (MCR), to increase conformance with the American Academy of Ophthalmology (AAO) Preferred Practice Pattern guidelines for treatment of primary open-angle glaucoma. Methods: Records of 591 patients with newly diagnosed glaucoma were assessed retrospectively for the completion of 9 AAO Preferred Practice Pattern recommended metrics including measured corneal thickness, intraocular pressure (IOP), cup to disk ratio, visual acuity, recorded IOP target, gonioscopy, fundus photos, ocular coherence tomography, and visual field in the 3 years before and 3 years after protocol implementation. Treatment by the glaucoma care team at MCR was compared with treatment at a community-based general ophthalmology practice and with a group of comprehensive ophthalmologists at MCR without team care, which served as controls. Results: Adherence to AAO recommendations increased for the documentation of target IOP (+24%, 42.6% to 66.7%; P=0.007), gonioscopy (+27%, 66.7% to 93.3%; P≤0.001), fundus photos (+29%, 44.4% to 73.3%; P≤0.001), and ocular coherence tomography (+20%, 48.1% to 68.0%; P=0.02) after protocol initiation. No change in pattern of testing occurred in the control groups without team care during the same time period. Type and severity of glaucoma were similar between MCR and community practice. Conclusions: An increase in compliance with AAO guidelines was found after implementation of our protocol for a physician-led, team-based care model to standardize glaucoma care among providers.
Right ventricular pacemaker lead position is associated with differences in long‐term outcomes and complications
Witt, Chance M. , Lenz, Charles J., Shih, Henry, Ebrille, Elisa , Rosenbaum, Andrew , Zyl, Martin van , Aung, Htin , Manocha, Kevin K. , Deshmukh, Abhishek , Hodge, David O. , Mulpuru, Siva K. , Cha, Yong‐Mei , Espinosa, Raúl E. , Asirvatham, Samuel J. , McLeod, Christopher J. , Asirvatham, Samuel J

Journal of Cardiovascular Electrophysiology | May 25, 2017 | Volume: 28 | Issue: 8 | Pages: 924-930

10.1111/jce.13256 | PMID 28543771 Get It

AbstractIntroductionCardiac pacing from the right ventricular apex is associated with detrimental long‐term effects and nonapical pacing locations may be associated with improved outcomes. There is little data regarding complications with nonapical lead positions. The aim of this study was to assess long‐term outcomes and lead‐related complications associated with differing ventricular lead tip position.Methods and resultsAll adult patients who underwent dual‐chamber pacemaker implantation from 2004 to 2014 were included if they had postprocedure chest radiographs amenable to lead position determination. Long‐term outcomes and lead‐related complication rates were recorded. These were compared at 5 years between: (1) apical and septal leads, (2) apical and nonseptal nonapical (NSNA), and (3) apical and septal with >40% ventricular pacing. We retrospectively evaluated 3,450 patients, which included 238 with a septal position and 733 with NSNA lead positions. Septal lead position was associated with a lower mortality compared to apical leads (24% vs. 31%, P = 0.02). In patients with greater than 40% pacing, septal leads were associated with significantly higher rates of incident atrial fibrillation compared to apical leads (49% vs. 34%, P = 0.04). NSNA positions were associated with a significantly higher rate of lead dislodgement (4% vs. 2%, P = 0.005) and need for revision (8% vs. 5%, P = 0.005).ConclusionsSeptal pacemaker lead position is associated with a lower mortality compared to apically placed leads, but a higher incidence of atrial fibrillation with higher percentage ventricular pacing. NSNA lead locations are associated with more complications and should be avoided.
Opioid Use in Patients with Congestive Heart Failure
Dawson, Nancy L. , Roth, Victoria, Hodge, David O. , Vargas, Emily , Burton, M. Caroline , Brennan, Emily , Vargas, Emily R

Pain Medicine | April 20, 2017 | Volume: 19 | Issue: 3 | Pages: 485-490

10.1093/pm/pnx103 | PMID 28460060 Get It

Utility of T-wave amplitude as a non-invasive risk marker of sudden cardiac death in hypertrophic cardiomyopathy
Sugrue, Alan , Killu, Ammar M. , Chahal, C. Anwar A. , Vogt, J., Křemen, Václav , Hai, Jo Jo , Hodge, David O. , Acker, Nancy G., Geske, Jeffrey B. , Ackerman, Michael J. , Ommen, Steve R. , Lin, Grace , Brady, Peter A. , Chahal, Anwar A, Vogt, Josh C, Hai, JoJo, DeSimone, Christopher V. , Noseworthy, Peter A. , Chahal, Choudhary Anwar A , Kremen, Vaclav , Geske, Jeffrey B

Open Heart | February 24, 2017 | Volume: 4 | Issue: 1 | Pages: e000561

10.1136/openhrt-2016-000561 | PMID 28409011 Get It

Objective Sudden cardiac arrest (SCA) is the most devastating outcome in hypertrophic cardiomyopathy (HCM). We evaluated repolarisation features on the surface electrocardiogram (ECG) to identify the potential risk factors for SCA. Methods Data was collected from 52 patients with HCM who underwent implantable cardioverter defibrillator (ICD) implantation. Leads V2 and V5 from the ECG closest to the time of ICD implant were utilised for measuring the Tpeak-Tend interval (Tpe), QTc, Tpe/QTc, T-wave duration and T-wave amplitude. The presence of the five traditional SCA-associated risk factors was assessed, as well as the HCM risk-SCD score. Results 16 (30%) patients experienced aborted cardiac arrest over 8.5±4.1 years, with 9 receiving an ICD shock and 7 receiving ATP. On univariate analysis, T-wave amplitude was associated with appropriate ICD therapy (HR per 0.1 mV 0.79, 95% CI 0.56 to 0.96, p=0.02). Aborted SCA was not associated with a greater mean QTc duration, Tpeak-Tend interval, T-wave duration, or Tpe/QT ratio. Multivariate analysis (adjusting for cardinal HCM SCA-risk factors) showed T-wave amplitude in Lead V2 was an independent predictor of risk (adjusted HR per 0.1 mV 0.74, 95% CI 0.57 to 0.97, p=0.03). Addition of T-wave amplitude in Lead V2 to the traditional risk factors resulted in significant improvement in risk stratification (C-statistic from 0.65 to 0.75) but did not improve the performance of the HCM SCD-risk score. Conclusions T-wave amplitude is a novel marker of SCA in this high risk HCM population and may provide incremental predictive value to established risk factors. Further work is needed to define the role of repolarisation abnormalities in predicting SCA in HCM.