Citations

Mayo Clinic

Clear

406 citation(s) found for "Kallmes, D".

Trackability of distal access catheters: an in vitro quantitative evaluation of navigation strategies
Li, Jiahui , Tomasello, Alejandro , Requena, Manuel , Canals, Pere , Tiberi, Riccardo , Galve, Iñaki, Kallmes, David F. , Ribó, Marc , Ribo, Marc , Li, Jiahui , Requena, Manuel , Engel, Elisabeth , Castaño, Óscar , Tomasello, Alejandro

Journal of NeuroInterventional Surgery | April 21, 2022 | Volume: 15 | Issue: 5 | Pages: 496-501

10.1136/neurintsurg-2022-018889 | PMID 35450927 Get It

Background In mechanical thrombectomy (MT), distal access catheters (DACs) are tracked through the vascular anatomy to reach the occlusion site. The inability of DACs to reach the occlusion site has been reported as a predictor of unsuccessful recanalization. This study aims to provide insight into how to navigate devices through the vascular anatomy with minimal track forces, since higher forces may imply more risk of vascular injuries. Methods We designed an experimental setup to monitor DAC track forces when navigating through an in vitro anatomical model. Experiments were recorded to study mechanical behaviors such as tension buildup against vessel walls, DAC buckling, and abrupt advancements. A multiple regression analysis was performed to predict track forces from the catheters’ design specifications. Results DACs were successfully delivered to the target M1 in 60 of 63 in vitro experiments (95.2%). Compared to navigation with unsupported DAC, the concomitant coaxial use of a microcatheter/microguidewire and microcatheter/stent retriever anchoring significantly reduced the track forces by about 63% and 77%, respectively (p<0.01). The presence of the braid pattern in the reinforcement significantly reduced the track forces regardless of the technique used (p<0.05). Combined coil and braid reinforcement configuration, as compared with coil alone, and a thinner distal wall were predictors of lower track force when navigating with unsupported DAC. Conclusions The use of microcatheter and stent retriever facilitate smooth navigation of DACs through the vascular tortuosity to reach the occlusion site, which in turn improves the reliability of tracking when positioning the DAC closer to the thrombus interface.
Risk of Early Versus Later Rebleeding From Dural Arteriovenous Fistulas With Cortical Venous Drainage
Durnford, Andrew , Akarca, Danyal , Culliford, David , Millar, John S. , Guniganti, Ridhima , Giordan, Enrico , Brinjikji, Waleed , Chen, Ching‐Jen , Abecassis, Isaac Josh , Levitt, Michael R. , Polifka, Adam , Derdeyn, Colin P. , Kwasnicki, Amanda , Alaraj, Ali , Potgieser, Adriaan R. E., Tada, Yoshiteru , Abla, Adib A. , Satomi, Junichiro, Starke, Robert M., Dijk, J. Marc C. van , Amin‐Hanjani, Sepideh , Hayakawa, M. , Gross, Bradley A. , Kim, Louis J. , Sheehan, Jason P. , Kansagra, Akash P. , Lai, Rosalind, Zipfel, Gregory J. , Bulters, Diederik , Piccirillo, Jay F. , Vine, Roanna , Cloft, Harry J. , Kallmes, David F. , Pollock, Bruce E. , Link, Michael J. , Patibandla, Mohana Rao, Ding, Dale , Buell, Thomas J. , Paisan, Gabriella, Meyer, R. Michael, Kelly, Cory , Duffill, Jonathan, Ditchfield, Adam, Macdonald, Jason, Laurent, Dimitri , Lockerman, Ashley, Lunsford, L. Dade , Jankowitz, Brian T. , Guerrero, Waldo R. , McGruder, Allen, Charbel, Fady T. , Aletich, Victor , Rose‐Finnell, Linda, Peterson, Eric C. , Yavagal, Dileep R. , Sur, Samir , Kanematsu, Yasuhisa , Kinouchi, T. , Korai, Masaaki , Yamaguchi, Izumi , Yamamoto, Yuki , Winkler, Ethan A. , Lawton, Michael T. , Rutkowski, Martin J. , Sultan, M. Ali Aziz, Patel, Nirav , Frerichs, Kai U., Levitt, Michael R , Polifka, Adam J , Samaniego, Edgar A , Alaraj, Ali , Tada, Yoshiteru , Phelps, Ryan , Abla, Adib , van DijK, J Marc C , Amin-Hanjani, Sepideh , Gross, Bradley , Fox, W Christopher , Kim, Louis J. , Sheehan, Jason , Lanzino, Giuseppe , Kansagra, Akash P , Du, Rose , Lai, Rosalind , Zipfel, Gregory J , Bulters, Diederik O , Ding, Dale , Chen, Ching-Jen , Derdeyn, Colin P , Abecassis, Isaac Josh , Millar, John, Chen, Stephanie , Lanzino, Giuseppe , Raman, Hari S. , Lipsey, Kim L. , Hoh, Brian L. , Smith, Jessica , Ortega-Gutierrez, Santiago , Hasan, David , Roa, Jorge A. , Rossen, James D. , Yamamoto, Nobuaki

Stroke | April 14, 2022 | Volume: 53 | Issue: 7 | Pages: 2340-2345

10.1161/strokeaha.121.036450 | PMID 35420453 Get It

Background: Cranial dural arteriovenous fistulas with cortical venous drainage are rare lesions that can present with hemorrhage. A high rate of rebleeding in the early period following hemorrhage has been reported, but published long-term rates are much lower. No study has examined how risk of rebleeding changes over time. Our objective was to quantify the relative incidence of rebleeding in the early and later periods following hemorrhage. Methods: Patients with dural arteriovenous fistula and cortical venous drainage presenting with hemorrhage were identified from the multinational CONDOR (Consortium for Dural Fistula Outcomes Research) database. Natural history follow-up was defined as time from hemorrhage to first treatment, rebleed, or last follow-up. Rebleeding in the first 2 weeks and first year were compared using incidence rate ratio and difference. Results: Of 1077 patients, 250 met the inclusion criteria and had 95 cumulative person-years natural history follow-up. The overall annualized rebleed rate was 7.3% (95% CI, 3.2–14.5). The incidence rate of rebleeding in the first 2 weeks was 0.0011 per person-day; an early rebleed risk of 1.6% in the first 14 days (95% CI, 0.3–5.1). For the remainder of the first year, the incidence rate was 0.00015 per person-day; a rebleed rate of 5.3% (CI, 1.7–12.4) over 1 year. The incidence rate ratio was 7.3 (95% CI, 1.4–37.7; P , 0.026). Conclusions: The risk of rebleeding of a dural arteriovenous fistula with cortical venous drainage presenting with hemorrhage is increased in the first 2 weeks justifying early treatment. However, the magnitude of this increase may be considerably lower than previously thought. Treatment within 5 days was associated with a low rate of rebleeding and appears an appropriate timeframe.
Correspondence on “Unplanned readmission after carotid stenting versus endarterectomy: analysis of the United States Nationwide Readmissions Database" by Nazari et al
Ghozy, Sherief , Dmytriw, Adam A. , Kadirvel, Ramanathan , Kallmes, David F. , Azzam, Ahmed Y , Ghozy, Sherief , Dmytriw, Adam A , Kadirvel, Ram , Kallmes, Kevin M

Journal of NeuroInterventional Surgery | March 23, 2022 | Volume: 15 | Issue: 3 | Pages: e1-e1

10.1136/neurintsurg-2022-018838 | PMID 35321868 Get It

Evaluation of hearing loss in young adults after exposure to 3.0T MRI with standard hearing protection
Carr, Carrie M. , Lane, John I , Eckel, Larry J, Diehn, Felix E. , Kallmes, Dave F, Carlson, Matthew L. , Shu, Yunhong , Gunderson, Tina M. , Poling, Gayla L. , Carr, Carrie M , Poling, Gayla L , Diehn, Felix E , Lane, John I , Bernstein, Matt A.

The Journal of the Acoustical Society of America | March 21, 2022 | Volume: 151 | Issue: 3 | Pages: 1913-1921

10.1121/10.0009824 | PMID 35364910 Get It

Standard clinical protocols require hearing protection during magnetic resonance imaging (MRI) for patient safety. This investigation prospectively evaluated the auditory function impact of acoustic noise exposure during a 3.0T MRI in healthy adults. Twenty-nine participants with normal hearing underwent a comprehensive audiologic assessment before and immediately following a clinically indicated head MRI. Appropriate hearing protection with earplugs (and pads) was used per standard of practice. To characterize noise hazards, current sound monitoring tools were used to measure levels of pulse sequences measured. A third audiologic test was performed if a significant threshold shift (STS) was identified at the second test, within 30 days post MRI. Some sequences produced high levels (up to 114.5 dBA; 129 dB peak SPL) that required hearing protection but did not exceed 100% daily noise dose. One participant exhibited an STS in the frequency region most highly associated with noise-induced hearing loss. No participants experienced OSHA-defined STS in either ear. Overall, OAE measures did not show evidence of changes in cochlear function after MRI. In conclusion, hearing threshold shifts associated with hearing loss or OAE level shifts reflecting underlying cochlear damage were not detected in any of the 3.0T MRI study participants who used the current recommended hearing protection.
Abstract WP48: Inter-rater Reliability for Radiological Studies Used to Select Patients for Endovascular Stroke Therapy
Fugate, Jennifer E. , Brinjikji, Waleed , Kallmes, David F. , Cloft, Harry J. , Rabinstein, Alejandro A.

Stroke | March 20, 2022 | Volume: 47 | Issue: suppl_1 | Pages: No page available

10.1161/str.47.suppl_1.wp48 Get It

Introduction: The selection of acute ischemic stroke patients relies on the interpretation of radiological studies, commonly including noncontrast CT (ASPECTS score), CTA, and in some circumstances, CT perfusion (CTP) scans. Hypothesis: The interrater reliability between readers of noncontrast head CT will be moderate and not as good as that between readers of CT perfusion scans. Methods: Retrospective study of consecutive ischemic stroke patients who were considered for endovascular stroke therapy at an academic medical center from April 2010 - November 2014. All patients underwent CT, CTA, and CTP. Images were independently reviewed by four readers (A, B, C, D) in total (2 experienced neuroradiologists, one experienced neurointensivist, and one neuroradiology fellow). Each rated half of the cohort. All readers performed online training in ASPECTS. Moderate-to-good collateral circulation was defined as filling of 50% or more of the middle cerebral artery pial arterial territory on CTA, as in ESCAPE trial. An “acceptable core” on CTP was defined as in EXTEND-IA trial with core volume < 70 mL, mismatch ratio >1.2, and absolute mismatch volume >10 mL but was qualitatively estimated. Interrater agreement was assessed for total ASPECTS, dichotomized ASPECTS (≥6 vs <6), evaluation of collaterals, and evaluation of core. Agreement was assessed using kappa statistic, which was weighted for the total ASPECTS analysis. Results: Our cohort included 119 patients with acute stroke and large vessel occlusion. Interrater agreement for total ASPECTS was very good between readers C and D (' 0.70) and good between A and B (' 0.55). For dichotomized ASPECTS, agreement was fair-to-good (' 0.30 for C/D; ' 0.41 for A/B). Agreement for grading collaterals on CTA was good to very good (' 0.64 for C /D; ' 0.54 for A/B). Agreement for rating core on CTP was very good (' 0.78 for C/D; ' 0.62 for A/D). Conclusions: Interrater reliability is good to very good for total ASPECTS score, dichotomous grading of collaterals on CTA, and subjective estimation of core size on CTP. Agreement is only fair to good for dichotomized ASPECTS.
Abstract WMP27: Differential Gene Expression in Coiled Versus Flow-diverter Treated Aneurysms: a RNA-Seq Analysis in Rabbit Aneurysm Model
Johnson, Collin R., Thielen, Evan , Schroeder, Dana , Ding, Yong Hong, Kallmes, David F. , Kadirvel, Ramanathan , Rouchaud, Aymeric , Ding, Yonghong , Dai, Daying , Cebral, Juan R.

Stroke | March 20, 2022 | Volume: 47 | Issue: suppl_1 | Pages: No page available

10.1161/str.47.suppl_1.wmp27 Get It

Introduction: Numerous endovascular tools exist for the treatment of intracranial aneurysms with an increased use of flow-diverting devices in recent years. However, the biological mechanisms leading to aneurysm healing or potential complications such as delayed aneurysm ruptures after flow-diverter treatment are not yet well established. We used RNA-sequencing technology to identify genes relevant for biological impact of coils and flow-diverters in elastase-induced saccular aneurysms in rabbits and to identify genes and pathways of potential clinical interest. Methods: Elastase-induced saccular aneurysms were created at the origin of the right common carotid artery. Aneurysms were treated with coils (n=5) or flow-diverters (Pipeline Embolic Device, Covidien, CA) (n=4). Untreated aneurysms (n=6) were used as controls. Messenger RNA and microRNA were isolated from the aneurysms at 4 weeks following treatment. RNA samples were processed using RNA-seq technology. RNA-seq results were analyzed by using the Ingenuity Pathway Analysis tool. Results: Using RNA sequencing for coiled versus non-treated aneurysms, 464 genes were found to be differentially expressed with 58 genes down regulated and 406 genes up regulated. Using the same criteria for the flow-diverter treated aneurysms, 177 genes were found to be differentially expressed with 8 genes down regulated and 169 genes up regulated. Comparing coiled versus flow-diverter treated aneurysms, 13 genes were significantly differentially expressed with 8 down regulated and 5 up regulated genes. Genes identified with the highest interest for aneurysms healing were fibroblast growth factor-23, matrix metalloproteinases (MMP)-1, Scinderin and Basigin (implicated in MMP-2 and MMP-9 regulation). Pathway analysis associated these genes with inflammatory response, cellular migration, and coagulation, among other functions. Conclusions: RNA-sequencing analysis of rabbit aneurysms revealed differential regulation of some key pathways, including inflammation and cellular migration that could explain the different biological mechanisms implicated in aneurysms healing either after coiling or flow-diverter treatments and could explain potential device-related complications.
Abstract TP86: Predicting Aneurysm Occlusion After Flow Diversion
Mut, Fernando , Chung, BongJae, Kadirvel, Ramanathan , Kallmes, David F. , Scrivano, Esteban , Lylyk, Pedro , Cebral, Juan R. , Bleise, Carlos

Stroke | March 20, 2022 | Volume: 47 | Issue: suppl_1 | Pages: No page available

10.1161/str.47.suppl_1.tp86 Get It

Introduction: Predicting the course of aneurysms after treatment with flow diverters is important to prognosticate long term outcomes and optimize interventions. Hypothesis: Aneurysm occlusion after flow diversion can be predicted using post-treatment flow information. Methods: Flows in experimental aneurysms in rabbits (n=15) and clinical cases (n=23) were evaluated with computational fluid dynamics. Subject-specific models were created from 3D angiographies. Flow conditions were measured with ultrasound in the rabbits, and derived from measurements in normal subjects in the clinical cases. Models of the devices were virtually deployed into the anatomical models. Experimental aneurysms were assigned to either a “complete” occlusion group if completely occluded at 4 weeks follow up, or to an “incomplete” occlusion group if still open at 8 weeks. Similarly, clinical cases were classified as “complete” occlusions if completely occluded at 3 months, or as “incomplete” occlusions if still patent at 6 months. Flow variables were then statistically compared between these groups for both the experimental and clinical series, and the predictive power of different variables to discriminate between aneurysms in each group was assessed by calculating the area under the receiving operating characteristics curves. Results: In the clinical (experimental) series, the aneurysm inflow rate was 4.02 (3.29) times larger in the incomplete occlusion group than in the completely occluded group, p=0.0210 (0.0239). Similarly, the mean aneurysm velocity was 2.75 (2.29) times larger, p=0.0044 (0.0582), and the shear rate was 1.57 (1.78) times larger, p=0.0210 (0.0722). Inflow rate could discriminate complete and incomplete occlusions with a 77% (90%) accuracy in the clinical (experimental) series. Similarly, mean velocity had a predictive power of 84% (83%) and shear rate of 76% (76%) in the clinical and experimental series. Conclusions: Flow conditions created immediately after treatment, in particular aneurysm inflow rate and mean aneurysm velocity, can prognosticate the future occlusion of aneurysms treated with flow diverters.
Abstract W P78: Gene Expression Comparison of Flow Diversion and Coiling in an Experimental Aneurysm Model
Puffer, Cole, Kallmes, David F. , Kadirvel, Ram , Ding, Yonghong , Dai, Daying , Cebral, Juan R. , Kadirvel, Ramanathan

Stroke | March 20, 2022 | Volume: 46 | Issue: suppl_1 | Pages: No page available

10.1161/str.46.suppl_1.wp78 Get It

Backgound and Purpose: Mechanisms of both healing and complications, including spontaneous aneurysm rupture, remain unclear following flow diverter treatment. The aim of the current study was to compare the gene expression of various key molecules involved in the healing of aneurysms between aneurysms treated with microcoils and flow diverters. Methods: Saccular aneurysms were created in rabbits (n=12). Aneurysms were either treated with coils (n=6) or with flow diverters (n=6). Aneurysm tissue was harvested at four weeks following treatment and used for gene expression and zymography experiments. Genes with a fold change of 1.2 or greater were considered up regulated, whereas those with a fold change of 0.8 or less were considered down regulated. Results: All coil embolized aneurysms were completely occluded at follow up. Two aneurysms were occluded and the remaining four samples were incompletely occluded in the flow diverter treated group. The following genes were expressed at lower levels in the flow diverter group as compared to the coiled aneurysm group: genes encoding proteinases (matrix metalloproteinases -2 and -9), cellular markers (endothelial nitric oxide synthase and smooth muscle actin), and structural proteins (collagens and fibronectin). Genes related to inflammation (tumor necrosis factor-α and monocyte chemoattractant protein -1) were up regulated in flow diverter treated aneurysms compared to coil embolized aneurysms. Notably, the enzymatic activity of active MMP-9 was high in aneurysms treated with flow diverters. Conclusion: As compared to coiled aneurysms, the molecular milieu surrounding aneurysms treated with flow diverters is characterized by higher levels of activated proteases, elevated expression of genes encoding inflammatory proteins, and diminished expression of genes encoding structural proteins. These data may provide improved understanding of rupture risk and healing following aneurysm treatment, and inform development of therapies aimed at lowering rupture risk and accelerating healing.
Abstract W MP43: Platelet Testing is Associated With Worse Clinical Outcomes for Intracranial Aneurysm Patients Treated with the Pipeline Embolization Device
Brinjikji, Waleed , Cloft, Harry J. , Kallmes, David F. , Lanzino, Giuseppe , Hanel, Ricardó A. , Siddiqui, Adnan H.

Stroke | March 20, 2022 | Volume: 46 | Issue: suppl_1 | Pages: No page available

10.1161/str.46.suppl_1.wmp43 Get It

Objective: Controversy exists as to whether platelet inhibition testing is necessary prior to aneurysm treatment in patients premedicated with antiplatelet agents. Using the IntrePED ( Int ernational Re trospective Study of P ipeline E mbolization D evice) registry, we studied complication rates in platelet-testing and non-platelet testing groups to determine if platelet testing is associated with improved outcomes. Materials and Methods: Patients with unruptured intracranial aneurysms from the INTREPED registry were divided into those who received platelet testing (testing group) and those who did not (nontesting group). Morbidity, mortality and thrombotic and hemorrhagic complication rates were studied. Comparisons between groups for continuous variables were evaluated using t -tests and Fisher’s exact test or Pearson’s chi-square for binary categorical variables. Multivariate logistic regression analysis was performed to determine if platelet function testing was independently associated with poor outcomes adjusting for age, number of devices, aneurysm location, size, and use of multiple exchange wires. Results: When compared to the non-testing group, the platelet testing group suffered higher rates of ipsilateral intracranial hemorrhage (12/511, 2.3% versus 0/187, 0.0%, P=0.04), neurological morbidity (42/511, 8.2% versus 4/187, 2.1%, P=0.01), and combined neurological morbidity and mortality (45/511, 8.8% versus 6/187, 3.2%, P=0.01). More patients in the testing group were treated with multiple PEDs (228 patients, 38.1% versus 57 patients, 28.4%, P=0.01). On multivariate analysis, the platelet testing group had a higher odds of total major morbidity (OR=3.80, 95%CI=1.30=11.08, P=0.01) and total major morbidity and neurological mortality (OR=2.74, 95%CI=1.11-6.79). Conclusion: Our findings caution against blind acceptance of platelet testing in Pipeline patients. Further prospective studies are needed to determine if and when platelet testing in Pipeline patients is appropriate.
Abstract W MP34: Safety and Efficacy of Hydrosoft Coils in the Treatment of the Aneurysm Neck: Preliminary Results From the GEL THE NEC Registry
Brinjikji, Waleed , Connelly, Beth B, Tubman, D, Jensen, Mary E. , Chaudry, I, Kallmes, David F. , Hoh, Brian L. , Kelly, Michael , Jabbour, Pascal , Hui, Ferdinand

Stroke | March 20, 2022 | Volume: 45 | Issue: suppl_1 | Pages: No page available

10.1161/str.45.suppl_1.wmp34 Get It

Background and Purpose: The HydroSoft coil was developed to be placed along the aneurysm neck to enhance intracranial aneurysm healing. In order to better understand the safety and efficacy of Hydrosoft coils in treating the aneurysm neck, the GEL THE NEC multicenter registry was developed. We report immediate angiographic and clinical results of this prospective registry. Methods: The GEL THE NEC study was undertaken at 30 centers in 5 countries. Patients aged 21-90 years with a ruptured or unruptured aneurysm 3-15 mm in size were eligible for enrollment. For each patient the following data were obtained: demographics and comorbidities, aneurysm geometry, use of adjunctive devices, immediate angiographic outcomes, and early (<30 days) adverse events. Postoperative anatomic results were graded by on-site neuroradiologists using the Modified Raymond Scale (Raymond 1=complete obliteration of aneurysm including the neck, Raymond 2=contrast filling the neck of the aneurysm without opacification of the aneurysm sac, Raymond 3=contrast filling the sac of the aneurysm). Predictors of good angiographic outcome were studied using chi-squared and t-tests. Results: A total of 571 patients with 571 aneurysms have been treated thus far in the study (196 ruptured, 375 unruptured). HydroSoft coils were successfully deployed in 549 (96.3%) of these patients. Adjunctive devices were used in 307 cases (53.8%) (212 balloon assistance, 89 stent). Aneurysmal occlusion rates were the following: 261 patients (47.3%) exhibited Raymond 1 occlusion, 257 patients (47.0%) had Raymond 2, and 29 patients (5.3%) had Raymond 3. Early post-operative stroke occurred in 10 patients (1.8%). Aneurysm perforation occurred in 11 patients (1.9%). Coil prolapse/migration occurred in 8 patients (1.4%). Early post-operative death occurred in 3 patients, all of whom presented with SAH (0.5%). Small aneurysm neck size was a significant predictor of good angiographic outcome (P=0.0003). Conclusions: Endovascular treatment of intracranial aneurysms with HydroSoft coils resulted in high rates of satisfactory occlusion (94.3%) and low rates of major clinical complications. Aneurysm neck size was a significant predictor of angiographic outcomes.