Citations

Mayo Clinic

Clear

1992 citation(s) found for "Vu, Joshua".

The effect of concomitant fields in fast spin echo acquisition on asymmetric MRI gradient systems
Tao, Shengzhen , Weavers, Paul T., Trzasko, Joshua D. , Shu, Yunhong , Gray, Erin M. , Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Huston, John , Foo, Thomas K F

Magnetic Resonance in Medicine | June 23, 2017 | Volume: 79 | Issue: 3 | Pages: 1354-1364

10.1002/mrm.26789 | PMID 28643408 Get It

PurposeTo investigate the effect of the asymmetric gradient concomitant fields (CF) with zeroth and first‐order spatial dependence on fast/turbo spin‐echo acquisitions, and to demonstrate the effectiveness of their real‐time compensation.MethodsAfter briefly reviewing the CF produced by asymmetric gradients, the effects of the additional zeroth and first‐order CFs on these systems are investigated using extended‐phase graph simulations. Phantom and in vivo experiments are performed to corroborate the simulation. Experiments are performed before and after the real‐time compensations using frequency tracking and gradient pre‐emphasis to demonstrate their effectiveness in correcting the additional CFs. The interaction between the CFs and prescan‐based correction to compensate for eddy currents is also investigated.ResultsIt is demonstrated that, unlike the second‐order CFs on conventional gradients, the additional zeroth/first‐order CFs on asymmetric gradients cause substantial signal loss and dark banding in fast spin‐echo acquisitions within a typical brain‐scan field of view. They can confound the prescan correction for eddy currents and degrade image quality. Performing real‐time compensation successfully eliminates the artifacts.ConclusionsWe demonstrate that the zeroth/first‐order CFs specific to asymmetric gradients can cause substantial artifacts, including signal loss and dark bands for brain imaging. These effects can be corrected using real‐time compensation. Magn Reson Med 79:1354–1364, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Erratum to: Development of a Unifying Target and Consensus Indicators for Global Surgical Systems Strengthening: Proposed by the Global Alliance for Surgery, Obstetric, Trauma, and Anaesthesia Care (The G4 Alliance)
Haider, Adil H. , Scott, John W. , Gause, Colin D., Meheš, Mira, Hsiung, Grace, Prelvukaj, Albulena, Yanocha, Dana, Baumann, Lauren M., Ahmed, Faheem , Ahmed, Naeem , Anderson, Sara, Angaté, Hervé, Arfaa, Lisa, Asbun, Horacio J. , Ashengo, Tigistu Adamu , Asuman, Kisembo, Bickler, Stephen W. , Billingsley, Saul, Bird, Peter, Botman, Matthijs , Butler, Marilyn, Buyske, Jo, Capozzi, Angelo, Casey, Kathleen , Clayton, Charles, Cobey, James C., Cotton, Michael , Deckelbaum, Dan, Derbew, Miliard , deVries, Catherine R. , Dillner, Jeanne, Downham, Max, Draisin, Natalie, Echinard, David, Elneil, Sohier , ElSayed, Ahmed , Estelle, Abigail, Finley, G. Allen , Frenkel, Erica, Frykman, Philip K., Gheorghe, Florin, Gore‐Booth, Julian, Henker, Richard , Henry, Jaymie , Henry, Orion, Hoemeke, Laura , Ibanga, Iko, Jackson, Eric V., Jani, Pankaj , Johnson, Walter D. , Jones, Andrew , Kassem, Zeina, Kocan, Abbey, Krishnaswami, Sanjay , Lane, Robert H. , Latif, Asad , Levy, Barbara , Linos, Dimitrios , Linz, Peter E., Listwa, Louis A., Magee, Declan, Makasa, Emmanuel , Marin, Michael L. , Martin, Claude , McQueen, Kelly, Morgan, Jamie , Moser, Richard , Neighbor, Robert, Novick, William M. , Ogendo, Stephen, Omigbodun, Akinyinka , Onajin‐Obembe, Bisola , Parsan, Neil, Philip, Beverly K., Price, Raymond R. , Rasheed, Shahnawaz, Ratel, M, Reynolds, Cheri, Roser, Steven M. , Rowles, Jackie , Samad, Lubna , Sampson, John , Sanghvi, Harshadkumar, Sellers, Marchelle L., Sigalet, David L. , Steffes, Bruce C., Stieber, Erin, Swaroop, Mamta , Tarpley, John L. , Varghese, Asha , Varughese, Julie, Wagner, Richard, Warf, Benjamin C. , Wetzig, Neil , Williamson, Susan , Wood, Joshua, Zeidan, Anne, Zirkle, Lewis G. , Allen, Brendan, Abdullah, Fizan , Asbun, Horacio, Ayala, Ruben , Butler, Marilyn, Gheorghe, Florin, Hoffman, David C. , Lane, Robert, Varughese, Julie

World Journal of Surgery | June 22, 2017 | Volume: 41 | Issue: 10 | Pages: 2423-2425

10.1007/s00268-017-4067-7 | PMID 28642965 Get It

B0 concomitant field compensation for MRI systems employing asymmetric transverse gradient coils
Weavers, Paul T., Tao, Shengzhen , Trzasko, Joshua D. , Frigo, Louis M., Shu, Yunhong , Frick, Matthew A., Foo, Thomas , Bernstein, Matt A. , Bernstein, Matt A , Lee, Seung‐Kyun , Foo, Thomas K F

Magnetic Resonance in Medicine | June 22, 2017 | Volume: 79 | Issue: 3 | Pages: 1538-1544

10.1002/mrm.26790 | PMID 28639370 Get It

PurposeImaging gradients result in the generation of concomitant fields, or Maxwell fields, which are of increasing importance at higher gradient amplitudes. These time‐varying fields cause additional phase accumulation, which must be compensated for to avoid image artifacts. In the case of gradient systems employing symmetric design, the concomitant fields are well described with second‐order spatial variation. Gradient systems employing asymmetric design additionally generate concomitant fields with global (zeroth‐order or B0) and linear (first‐order) spatial dependence.MethodsThis work demonstrates a general solution to eliminate the zeroth‐order concomitant field by applying the correct B0 frequency shift in real time to counteract the concomitant fields. Results are demonstrated for phase contrast, spiral, echo‐planar imaging (EPI), and fast spin‐echo imaging.ResultsA global phase offset is reduced in the phase‐contrast exam, and blurring is virtually eliminated in spiral images. The bulk image shift in the phase‐encode direction is compensated for in EPI, whereas signal loss, ghosting, and blurring are corrected in the fast‐spin echo images.ConclusionA user‐transparent method to compensate the zeroth‐order concomitant field term by center frequency shifting is proposed and implemented. This solution allows all the existing pulse sequences—both product and research—to be retained without any modifications. Magn Reson Med 79:1538–1544, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
Effect of position, time in the season, and playing surface on Achilles tendon ruptures in NFL games: a 2009-10 to 2016-17 review
Krill, Michael K. , Borchers, James, Hoffman, Joshua, Krill, Matthew L., Hewett, Timothy E.

The Physician and Sportsmedicine | June 15, 2017 | Volume: 45 | Issue: 3 | Pages: 259-264

10.1080/00913847.2017.1343652 | PMID 28617627 Get It

Zinc deficiency primes the lung for ventilator-induced injury
Boudreault, Francis, Pinilla-Vera, Miguel , Englert, Joshua A. , Kho, Alvin T. , Isabelle, Colleen , Arciniegas, Antonio J. , Barragan-Bradford, Diana, Quintana, Carolina, Amador-Muñoz, Diana , Guan, Jiazhen, Choi, Kyoung Moo , Registry, MICU, Sholl, Lynette M. , Hurwitz, Shelley, Tschumperlin, Daniel J. , Baron, Rebecca M. , Registry, MICU

JCI Insight | June 1, 2017 | Volume: 2 | Issue: 11 | Pages: No page available

10.1172/jci.insight.86507 | PMID 28570269 Get It

Mechanical ventilation is necessary to support patients with acute lung injury, but also exacerbates injury through mechanical stress–activated signaling pathways. We show that stretch applied to cultured human cells, and to mouse lungs in vivo, induces robust expression of metallothionein, a potent antioxidant and cytoprotective molecule critical for cellular zinc homeostasis. Furthermore, genetic deficiency of murine metallothionein genes exacerbated lung injury caused by high tidal volume mechanical ventilation, identifying an adaptive role for these genes in limiting lung injury. Stretch induction of metallothionein required zinc and the zinc-binding transcription factor MTF1. We further show that mouse dietary zinc deficiency potentiates ventilator-induced lung injury, and that plasma zinc levels are significantly reduced in human patients who go on to develop acute respiratory distress syndrome (ARDS) compared with healthy and non-ARDS intensive care unit (ICU) controls, as well as with other ICU patients without ARDS. Taken together, our findings identify a potentially novel adaptive response of the lung to stretch and a critical role for zinc in defining the lung’s tolerance for mechanical ventilation. These results demonstrate that failure of stretch-adaptive responses play an important role in exacerbating mechanical ventilator–induced lung injury, and identify zinc and metallothionein as targets for lung-protective interventions in patients requiring mechanical ventilation.
A Combination of a Polycaprolactone Fumarate Scaffold with Polyethylene Terephthalate Sutures for Intra-Articular Ligament Regeneration
Parry, Joshua A. , Wagner, Eric R. , Kok, Peter L., Dadsetan, Mahrokh, Yaszemski, Michael J. , Wijnen, André J. van , van Wijnen, Andre J, Kakar, Sanjeev , van Wijnen, Andre J , Wagner, Eric R

Tissue Engineering Part A | May 20, 2017 | Volume: 24 | Issue: 3-4 | Pages: 245-253

10.1089/ten.tea.2016.0531 | PMID 28530131 Get It

Decreased bed rest post‐percutaneous coronary intervention with a 7‐French arterial sheath and its effects on vascular complications
Wentworth, Laura J., Bechtum, Elizabeth L., Hoffman, Jessica G, Kramer, Robert R., Bartel, David C., Slusser, Joshua P. , Tilbury, R. Thomas, Tilbury, Ralph Thomas

Journal of Clinical Nursing | May 17, 2017 | Volume: 27 | Issue: 1-2 | Pages: No page available

10.1111/jocn.13880 | PMID 28514498 Get It

Aims and objectivesTo compare the incidence of femoral access puncture site complications in the control group, who underwent 6 hr of bed rest, with patients in the case group, who underwent 4 hr of bed rest.BackgroundThe ideal bed rest length after percutaneous coronary intervention with a 7‐French arterial sheath has been investigated by nursing practice. However, in this larger‐sheath‐size group, best practices have not been determined, and bed rest time continues to vary markedly among institutions.DesignRetrospective study.MethodsData were retrieved from the National Cardiovascular Data Registry and electronic health records in this retrospective study. Sample size was 401 patients: 152 case patients with 4‐hr bed rest and 249 controls with 6‐hr bed rest. Case group data were obtained from 20 May 2013–31 December 2014; and control group data, 15 June 2011–20 May 2013.ResultsNational Cardiovascular Data Registry event rates were generally low in both groups: Only three patients in each group had a bleeding event within 72 hr (2% vs. 1%) and no patient and only two controls had arteriovenous fistula (0% vs. 1%). Complications documented in the electronic health records with institutional femoral access puncture site complication definitions identified bleeding at the access site in eight case patients (5%) and nine controls (4%). Haematoma at the access site occurred in 21 case patients (14%) and 25 controls (10%).ConclusionsThe practice change of decreasing bed rest from 6–4 hr for patients with 7‐French arterial sheaths post‐percutaneous coronary intervention was associated with no significant change in femoral access puncture site complications in either National Cardiovascular Data Registry data or institutional electronic health records data.Relevance to clinical practiceThis introduces expanded evidence of safety in decreasing bed rest length in larger (7‐French) arterial sheaths post‐percutaneous coronary intervention.
Development of a Unifying Target and Consensus Indicators for Global Surgical Systems Strengthening: Proposed by the Global Alliance for Surgery, Obstetric, Trauma, and Anaesthesia Care (The G4 Alliance)
Haider, Adil H. , Scott, John W. , Gause, Colin D., Meheš, Mira, Hsiung, Grace, Prelvukaj, Albulena, Yanocha, Dana, Baumann, Lauren M., Ahmed, Faheem , Ahmed, Naeem , Anderson, Sara, Angaté, Hervé, Arfaa, Lisa, Asbun, Horacio J. , Ashengo, Tigistu Adamu , Asuman, Kisembo, Ayala, Ruben , Bickler, Stephen W. , Billingsley, Saul, Bird, Peter, Botman, Matthijs , Butler, Marilyn, Buyske, Jo, Capozzi, Angelo, Casey, Kathleen , Clayton, Charles, Cobey, James C., Cotton, Michael , Deckelbaum, Dan, Derbew, Miliard , deVries, Catherine R. , Dillner, Jeanne, Downham, Max, Draisin, Natalie, Echinard, David, Elneil, Sohier , ElSayed, Ahmed , Estelle, Abigail, Finley, G. Allen , Frenkel, Erica, Frykman, Philip K., Gheorghe, Florin, Gore‐Booth, Julian, Henker, Richard , Henry, Jaymie , Henry, Orion, Hoemeke, Laura , Ibanga, Iko, Jackson, Eric V., Jani, Pankaj , Johnson, Walter D. , Jones, Andrew , Kassem, Zeina, Kocan, Abbey, Krishnaswami, Sanjay , Lane, Robert H. , Latif, Asad , Levy, Barbara , Linos, Dimitrios , Linz, Peter E., Listwa, Louis A., Magee, Declan, Makasa, Emmanuel , Marin, Michael L. , Martin, Claude , McQueen, Kelly, Morgan, Jamie , Moser, Richard , Neighbor, Robert, Novick, William M. , Ogendo, Stephen, Omigbodun, Akinyinka , Onajin‐Obembe, Bisola , Parsan, Neil, Philip, Beverly K., Price, Raymond R. , Rasheed, Shahnawaz, Ratel, M, Reynolds, Cheri, Roser, Steven M. , Rowles, Jackie , Samad, Lubna , Sampson, John , Sanghvi, Harshadkumar, Sellers, Marchelle L., Sigalet, David L. , Steffes, Bruce C., Stieber, Erin, Swaroop, Mamta , Tarpley, John L. , Varghese, Asha , Varughese, Julie, Wagner, Richard, Warf, Benjamin C. , Wetzig, Neil , Williamson, Susan , Wood, Joshua, Zeidan, Anne, Zirkle, Lewis G. , Allen, Brendan, Abdullah, Fizan , Asbun, Horacio, Butler, Marilyn, Gheorghe, Florin, Hoffman, David C. , Lane, Robert, Varughese, Julie

World Journal of Surgery | May 15, 2017 | Volume: 41 | Issue: 10 | Pages: 2426-2434

10.1007/s00268-017-4028-1 | PMID 28508237 Get It

AbstractAfter decades on the margins of primary health care, surgical and anaesthesia care is gaining increasing priority within the global development arena. The 2015 publications of the Disease Control Priorities third edition on Essential Surgery and the Lancet Commission on Global Surgery created a compelling evidenced‐based argument for the fundamental role of surgery and anaesthesia within cost‐effective health systems strengthening global strategy. The launch of the Global Alliance for Surgical, Obstetric, Trauma, and Anaesthesia Care in 2015 has further coordinated efforts to build priority for surgical care and anaesthesia. These combined efforts culminated in the approval of a World Health Assembly resolution recognizing the role of surgical care and anaesthesia as part of universal health coverage. Momentum gained from these milestones highlights the need to identify consensus goals, targets and indicators to guide policy implementation and track progress at the national level. Through an open consultative process that incorporated input from stakeholders from around the globe, a global target calling for safe surgical and anaesthesia care for 80% of the world by 2030 was proposed. In order to achieve this target, we also propose 15 consensus indicators that build on existing surgical systems metrics and expand the ability to prioritize surgical systems strengthening around the world.
Acute pressure changes in the brain are correlated with MR elastography stiffness measurements: initial feasibility in an in vivo large animal model
Arani, Arvin , Min, Hoon‐Ki , Fattahi, Nikoo , Wetjen, Nicholas M. , Trzasko, Joshua D. , Jack, Clifford R. , Lee, Kendall H. , Min, Hoon-Ki Paul , Manduca, Armando , Ehman, Richard L. , Huston, John , Jack, Clifford R , Arani, Arvin

Magnetic Resonance in Medicine | May 10, 2017 | Volume: 79 | Issue: 2 | Pages: 1043-1051

10.1002/mrm.26738 | PMID 28488326 Get It

PurposeThe homeostasis of intracranial pressure (ICP) is of paramount importance for maintaining normal brain function. A noninvasive technique capable of making direct measurements of ICP currently does not exist. MR elastography (MRE) is capable of noninvasively measuring brain tissue stiffness in vivo, and may act as a surrogate to measure ICP. The objective of this study was to investigate the impact of changing ICP on brain stiffness using MRE in a swine model.MethodsBaseline MRE measurements were obtained, and then catheters were surgically placed into the left and right lateral ventricles of three animals. ICP was systematically increased over the range of 0 to 55 millimeters mercury (mmHg), and stiffness measurements were made using brain MRE at vibration frequencies of 60 hertz (Hz), 90 Hz, 120 Hz, and 150 Hz.ResultsA significant linear correlation between stiffness and ICP in the cross‐subject comparison was observed for all tested vibrational frequencies (P ≤ 0.01). The 120 Hz (0.030 ± 0.004 kilopascal (kPa)/mmHg, P < 0.0001) and 150 Hz (0.031 ± 0.008 kPa/mmHg, P = 0.01) vibrational frequencies had nearly identical slopes, which were approximately two‐ to three‐fold higher than the 90 Hz (0.017 ± 0.002 kPa/mmHg, P < 0.0001) and 60 Hz (0.009 ± 0.002 kPa/mmHg, P = 0.001) slopes, respectively.ConclusionIn this study, MRE demonstrated the potential for noninvasive measurement of changes in ICP. Magn Reson Med 79:1043–1051, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
Acute and midterm results following perventricular device closure of muscular ventricular septal defects: A multicenter PICES investigation
Gray, Robert G. , Menon, Shaji C. , Johnson, Joyce T. , Bingler, Michael, Breinholt, John P. , Kenny, Damien , Lozier, John S. , Murphy, Joshua, Sathanandam, Shyam , Taggart, Nathaniel W. , Trucco, Sara M. , Goldstein, Bryan H. , Gordon, Brent M. , Armstrong, Aimee K. , Taggart, Nathaniel W , Goldstein, Bryan H

Catheterization and Cardiovascular Interventions | May 8, 2017 | Volume: 90 | Issue: 2 | Pages: 281-289

10.1002/ccd.27121 | PMID 28805027 Get It

ObjectivesTo describe acute and mid‐term results of hybrid perventricular device closure of muscular ventricular septal defects (mVSDs).BackgroundPerventricular device closure of mVSDs can mitigate technical limitations of percutaneous closure and need for cardiopulmonary bypass or ventriculotomy with a surgical approach.MethodsThis is a multicenter retrospective cohort study of patients undergoing hybrid perventricular mVSD device closure from 1/2004 to 1/2014. Procedural details, adverse events, outcomes, and follow‐up data were collected. Patients were divided into two groups: (1) simple (mVSD closure alone) and (2) complex (mVSD closure with concomitant cardiac surgery).ResultsForty‐seven patients (60% female) underwent perventricular mVSD device closure at a median age of 5.2 months (IQR 1.8–8.9) and weight of 5.1 kg (IQR 4.0–6.9). Procedural success was 91% [100% (n = 22) simple and 84% (n = 21/25) complex]. Adverse events occurred in 19% (9/47) [9% (2/22) simple and 28% (7/25) complex]. Hospital length of stay (LOS) was shorter in the simple vs. complex group (4 vs. 14 days, P < 0.01). At mid‐term follow‐up of 19.2 months (IQR 2.3–43) 90% of pts had complete mVSD closure; none developed late heart block, increased atrioventricular (AV) valve insufficiency or ventricular dysfunction.ConclusionsPerventricular device closure of simple mVSD was associated with a high rate of procedural success, few adverse events, and short hospital LOS. Procedural adverse events were associated with the presence of concomitant complex surgery. Residual mVSD, AV valve insufficiency, or ventricular dysfunction were uncommon at mid‐term follow‐up. © 2017 Wiley Periodicals, Inc.