Citations

Mayo Clinic

Showing 10 of 108490 citations.

Characterization, commissioning, and clinical evaluation of a commercial BeO optically stimulated luminescence (OSL) system
Kowalski, J., Erickson, Brett G. , Wu, Qiuwen , Li, Xinyi , Yoo, Sua , Kowalski, Joseph P.

Journal of Applied Clinical Medical Physics | February 22, 2025 | Volume: 26 | Issue: 4 | Pages: No page available

10.1002/acm2.70057 | PMID 39985562 Get It

AbstractThis article investigates the performance of a commercial BeO optically stimulated luminescent (OSL) dosimetry system (myOSLchip, RadPro GmbH International, Remscheid, Germany) through the application of the commissioning framework for luminescent dosimeters as described in the American Association of Physicists in Medicine Task Group 191 (AAPM TG191) report. Initial clinical experiences and dosimetric results are also presented. The following properties of the system were characterized: linearity correction factors ranged from ‐0.5% to +3% for dose levels spanning 0.1 to 20 Gy. Beam quality correction factors (relative to 6 MV) ranged from ‐4.5% (2.5FFF) to +4.5% (15MV) for photon beams and +1.9% (6 MeV) to +4.3% (20 MeV) for electron beams. An average (µ) signal loss per reading of ‐2.13% ± 0.20% was measured, however greater signal loss was observed in the first reading (µ = ‐2.6% ± 0.46%). An initial decline in individual element sensitivity relative to baseline was observed from 0–15 Gy cumulative dose (µ = ‐1.98% ± 0.55%), with negligible further deterioration from 15–32 Gy (µ = ‐2.38% ± 0.85%). Post‐irradiation, there was a transient OSL signal which faded with a half‐life of 1.8 min; this signal enhancement was +5% at 5 min post‐irradiation and +1% at 15 min relative to 24 h. Dosimeter response was not dependent on average dose rate in the range of 100–2500 MU/min. With respect to clinical testing, equal or superior performance compared with aluminum oxide OSLs (nanoDots) is shown for a range of clinical techniques and modalities including TSET, TBI, en‐face electrons, and pacemaker/out‐of‐field measurements. The feasibility of myOSLchip to serve as a primary clinical in vivo dosimetry system and direct replacement for Landauer's microStar system is demonstrated.
High-Power Short-Duration Ablation versus Conventional Power Ablation in Pulmonary Vein Isolation in Patients with Atrial Fibrillation: An Updated Systematic Review and Meta-Analysis of Randomized Controlled Trials
Cabral, David C. B. I. , Rivera, André , Braga, Marcelo Antonio Pinheiro , Passos, Bárbara Mariz Ferreira, Brígido, Alexandra Régia Dantas , Carvalho, Guilherme Dagostin de , Deshmukh, Abhishek , DeSimone, Christopher V. , DeSimone, Christopher V , Félix, Iuri Ferreira , Ternes, Caique M. P. , Rivera, A

No container title available | February 22, 2025 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.22541/au.174024725.57612852/v1 Get It

Introduction: High-power short-duration (HPSD) ablation has emerged as a promising alternative to conventional power delivery (CPD) for pulmonary vein isolation (PVI) among patients with atrial fibrillation (AF). However, its efficacy, procedural efficiency, and safety profile remain uncertain. Methods: PubMed, Embase, Cochrane Library and ClinicalTrials.Gov databases were systematically searched for randomized controlled trials (RCTs) comparing HPSD with CPD ablation for PVI in patients with AF. Random-effects models were used to pool hazard ratios (HR) and risk ratios (RR) with 95% confidence intervals (CI). R version 4.4.2 was used for statistical analysis. Results: Seven RCTs with 1,006 patients (514 HPSD, 489 CPD) were included. No significant differences were found in freedom from arrhythmia during the follow-up period (HR 0.77; 95% CI 0.41–1.45; p=0.424). AF recurrence did not differ (RR 0.94; 95% CI 0.65–1.36; p=0.733) between groups. HPSD had a significantly shorter procedural (MD -22.61 min; 95% CI -33.18, -12.04; p<0.001) and RF ablation times (MD -15.70 min; 95% CI -20.86, -10.55; p<0.001). No differences were observed in fluoroscopy time and first-pass isolation for right and left pulmonary veins. There was no difference in esophageal lesion rates, pericardial, or neurological complications, but there was a higher incidence of steam pops in HPSD (RR 3.42; 95% CI 1.45–8.09; p=0.005). Conclusion: In patients with AF undergoing PVI, HPSD did not increase freedom from arrhythmia as compared with CPD ablation, however it was associated with shorter procedure and RF ablation times with a similar safety profile.
Subsequent kilovoltage imaging‐based fiducial triangulation for intra‐fractional prostate motion monitoring and correction
Gevorkyan, Gevork S., Chen, Quan , Tegtmeier, Riley C. , Toesca, Diego Santos, Laughlin, Brady, Bashir, Sara, Welchel, Zachary James, Vargas, Carlos , Rwigema, Jean‐Claude M. , James, Sarah E. , Yu, Nathan Y. , Chen, Quan , Laughlin, Brady S. , Toesca, Diego A.S. , Gevorkyan, Gevork S. , Holmes, Jason , Rong, Yi

Medical Physics | February 22, 2025 | Volume: 52 | Issue: 6 | Pages: 4008-4022

10.1002/mp.17703 | PMID 39985556 Get It

Abstract Background Inter‐fractional and intra‐fractional positioning and motion monitoring based on implanted fiducials through kilovoltage (kV) imaging is a cost‐effective approach to enhance intact prostate radiotherapy treatment accuracy. However, comprehensive studies for three‐dimensional (3D) position extraction and the corrective action threshold are lacking. Purpose To develop and verify a fiducial motion monitoring system with 3D position information based on triggered kV images taken during treatment delivery, and to comprehensively evaluate the recommended thresholds for corrective action during treatment. Methods An in‐house fiducial triangulation algorithm was developed to monitor fiducial positions using subsequent kV triggered images. The precision of fiducial triangulation and motion detection was validated on a pelvis phantom with four fiducial inserts. A retrospective study was conducted on prostate cancer patients who received either moderately hypofractionated radiotherapy (MHRT, n = 16) or stereotactic body radiotherapy (SBRT, n = 12), categorized by endo‐rectal balloon (ERB) use. Intra‐fractional positions relative to isocenter were computed, and these positions were analyzed in comparison to the original marker locations of the patient's treatment plan. A linear regression fit was used per fraction to determine correlation coefficients between motions in the left–right (LR), superior–inferior (SI), and anterior–posterior (AP) directions. Average fraction time (AFT) of treatment was reported based on the observed average time spent on steps in the workflow and the percentage of fiducials caught outside of the current two‐dimensional (2D) tolerance threshold of 5 mm. The observed 3D offsets were used to estimate AFT for various 3D tolerance thresholds. Results Overall, our triangulation method proved to be very precise for static cases, where phantom measurements revealed a fiducial position triangulation precision of mm for stationary targets, but had a spread of mm for targets with 1 mm of motion. Employing triangulation, true motion exceeding 5 mm was detected above 4.0 mm in magnitude 90.9% of the time, a noticeable improvement in comparison to the 28%–65% successful detection rate reported by 2D projection methods. Most detection errors were attributed to depth disparity. Similar to other reports, correlation coefficients for intra‐fractional motion generally indicated no LR/SI, no LR/AP, and weak positive SI/AP correlations for MHRT and SBRT patients. Offsets beyond a 3D tolerance threshold of 5 mm were observed at a rate of 4.25%–5.25%, while the 5 mm 2D out‐of‐tolerance catch‐rate was 1.6%. The AFT was 8.1–8.2 min using the 2D tolerance threshold of 5 mm. In comparison, the estimated AFT for the proposed 3D tolerance monitoring of offsets beyond 2–5 mm was slightly higher at 8.2–10.9 min due to the higher amount of out‐of‐tolerance instances for the higher precision intra‐fractional motion management. Conclusions Our study showcases a promising subsequent kV‐based triangulation method for intra‐fractional prostate motion monitoring. Acquiring 3D motion information results in higher out‐of‐tolerance catch‐rates particularly in the depth dimension of the kV images, which is perpendicular to the treatment beam. Failure to properly observe and catch these offsets would result in sub‐optimal conformality and accuracy of the dose delivery.
Role of tau versus TDP‐43 pathology on medial temporal lobe atrophy in aging and Alzheimer's disease
Wisse, Laura E.M. , Wuestefeld, Anika , Murray, Melissa E., Jagust, William J. , Joie, Renaud La , La Joie, Renaud , Murray, Melissa E.

Alzheimer's & Dementia | February 22, 2025 | Volume: 21 | Issue: 2 | Pages: No page available

10.1002/alz.14582 | PMID 39985478 Get It

Abstract Hippocampal atrophy on magnetic resonance imaging is an important biomarker in Alzheimer's disease (AD). While hippocampal atrophy was thought to result from tau tangles in AD, different neuropathologies can lead to hippocampal atrophy, especially TAR DNA‐binding protein 43 (TDP‐43) pathology. In this narrative review, we evaluate existing studies on the relative contribution of tau and TDP‐43 pathology to medial temporal lobe (MTL) atrophy. We report a clear association of both tau and TDP‐43 neuropathology with MTL atrophy, even after correcting for other neuropathologies. Next, we discuss a potential synergism between tau and TDP‐43 and the relative timing of the effects of both neuropathologies. Finally, avenues for future research will be discussed. A better understanding of the interplay between tau and TDP‐43 neuropathologies and their effect on atrophy will help with the development of more specific biomarkers for limbic‐predominant age‐related TDP‐43 encephalopathy and pinpointing of the optimal timing for testing anti‐tau and anti‐TDP‐43 treatments in trials. Highlights Both tau and TAR DNA‐binding protein 43 (TDP‐43) pathology contribute to medial temporal lobe atrophy. There is a positive association between tau and TDP‐43 and potentially a synergism. It is unclear if tau and TDP‐43 have an additive or synergistic effect on atrophy. The relative timing of the tau and TDP‐43 effects on atrophy remains unclear. Clarifying the interplay between tau and TDP‐43 will help improve magnetic resonance imaging biomarkers.
ALCAPA: A Giant Right Coronary Artery Aneurysm
Raavi, Lekhya , Celik, Nafiye Busra , Garg, Pankaj , Haney, John C. , Haney, John, Garg, Pankaj

Oxford Medical Case Reports | February 22, 2025 | Volume: 2025 | Issue: 2 | Pages: No page available

10.1093/omcr/omae186 | PMID 39990027 Get It

Editorial: Association of Antibiotic Exposure With Microscopic Colitis
Tome, June , Pardi, Darrell S. , Tome, June

Alimentary Pharmacology & Therapeutics | February 22, 2025 | Volume: 61 | Issue: 9 | Pages: 1547-1548

10.1111/apt.70043 | PMID 39985121 Get It

BR or R-CHOP induction with rituximab maintenance in untreated, transplant-ineligible patients with mantle cell lymphoma
Gutmair, Katja , Villa, Diego , Cunningham, Nicholas , Silkenstedt, Elisabeth , Rimsza, Lisa M. , Ramsower, Colleen , Scott, David W. , Dreyling, Martin , Hoster, Eva , Rimsza, Lisa, Gerrie, Alina S , Kluin-Nelemans, Hanneke C , Dreyling, Martin , Hoster, Eva , Scott, David W , Ramsower, Colleen A , Cunningham, Nicholas, Gerrie, Alina S. , Kluin‐Nelemans, Hanneke C.

Blood Advances | February 21, 2025 | Volume: 9 | Issue: 9 | Pages: 2302-2306

10.1182/bloodadvances.2024015292 | PMID 39983085 Get It

Comparative meta-analysis of microsurgery versus endovascular therapy and bypass versus nonbypass techniques for blister-like aneurysms: enigmas of the supraclinoid internal carotid artery
Pennington, Zach , Patel, Saarang, Rahmani, Redi , Lawton, Michael T., Pennington, Zach , Brown, Nolan J. , Patel, Saarang , Tafreshi, Ali, Gendreau, Julian , Catapano, Joshua S , Lawton, Michael T.

Journal of Neurosurgery | February 21, 2025 | Volume: 143 | Issue: 1 | Pages: 243-254

10.3171/2024.8.jns232241 | PMID 39983119 Get It

OBJECTIVE Blister aneurysms of the internal carotid artery (ICA) have high associated mortality rates and are challenging due to their friable wall and poorly defined neck. Microsurgical and endovascular treatment options have been suggested, including bypass of the parent vessel to exclude the aneurysm. The goal of this study was to evaluate the safety and efficacy of microsurgical versus endovascular interventions. Additionally, for patients treated with open surgery, the outcomes of bypass were compared to nonbypass techniques. METHODS Three databases were systematically queried for primary studies comparing microsurgery to endovascular therapy and assessing bypass versus nonbypass treatment modalities for blister aneurysms of the ICA. All relevant studies published between 2000 and 2023 were eligible for inclusion. All articles were screened against title and abstract by 2 authors, as were those eligible for full-text assessment. Ultimately, relevant data from all included studies were pooled for meta-analysis in which the Mantel-Haenszel method with random-effects modeling was used. RESULTS Among the 504 cases reported across 24 studies, 182 (35.1%) blister aneurysms of the ICA were surgically treated, whereas 337 (64.9%) involved endovascular treatment. There were 235 (46.6%) female patients in the cohort. Functional outcomes were comparable between groups, with 83% of surgically treated patients and 85% of endovascularly treated patients achieving a favorable outcome (p > 0.05). Among the 7 studies (178 patients) comparing bypass to nonbypass microsurgery, rates of postoperative bleeding, ischemic infarct, vasospasm, recurrence, favorable outcomes, and mortality were comparable for bypass (n = 54, 30.3%) and nonbypass groups (n = 124, 69.7%). CONCLUSIONS Blister aneurysms of the ICA are rare intracranial aneurysms that are difficult to treat with microsurgical and endovascular techniques. Considering only patients treated with open surgery, there appears to be no significant difference in complication profile or functional outcomes between patients undergoing bypass or alternative microsurgical techniques. However, it must be noted that the complex nature of bypass procedures means that much of the data granularity is lost on meta-analysis, suggesting that additional investigations comparing bypass to other open microsurgical techniques may be merited. Similarly, future studies should determine the limitations of dual antiplatelet therapy in endovascular treatment and the efficacy of different numbers and types of overlapping, flow-diverting devices.
CT Motion-Analysis of Implant Loosening in Total Wrist Arthroplasty: A Pilot Study
Kakar, Sanj, Sandberg, Olof , Wretenberg, Per , Sagerfors, Marcus , Sagerfors, Marcus , Reiser, Daniel , Reiser, Daniel

Journal of Wrist Surgery | February 21, 2025 | Volume: 15 | Issue: 03 | Pages: 237-242

10.1055/a-2528-0045 | PMID 42179685 Get It

Abstract Total wrist arthroplasty (TWA) is a motion-preserving treatment option for wrist arthritis. High-precision measurement methods for implant migration such as computed tomography motion-analysis (CTMA) can potentially detect poor implant fixation. The aim of this pilot study was to assess CTMA as a complementary method to diagnose aseptic loosening of TWA. Three patients with a TWA and wrist pain during activity underwent induced displacement CT (CTMA) with alternated provocations as a complement to plain radiographs. Two of the three patients had displacement of the carpal component on CTMA. The radial component was stable in all cases. The tool was adapted to clinical routine use. CT motion-analysis could be a valuable adjunct to plain radiographs in assessing component loosening in TWA.