Citations

Mayo Clinic

Clear

162 citation(s) found for "Ehman, R L".

P4‐332: Regional brain stiffness changes across the Alzheimer's disease spectrum
Murphy, Matthew C. , Glaser, Kevin J. , Felmlee, Joel P. , Huston, John , Jack, Clifford R. , Jones, David T. , Senjem, Matthew L. , Manduca, Armando , Ehman, Richard L.

Alzheimer's & Dementia | March 29, 2014 | Volume: 8 | Issue: 4S_Part_21 | Pages: No page available

10.1016/j.jalz.2013.08.113 Get It

Feasibility of using 3D MR elastography to determine pancreatic stiffness in healthy volunteers
Shi, Yu , Glaser, Kevin J. , Venkatesh, Sudhakar K. , Ben‐Abraham, Ephraim I., Ehman, Richard L. , Venkatesh, Sudhakar K

Journal of Magnetic Resonance Imaging | February 5, 2014 | Volume: 41 | Issue: 2 | Pages: 369-375

10.1002/jmri.24572 | PMID 24497052 Get It

Purpose To evaluate the feasibility of using three‐dimensional (3D) MR elastography (MRE) to determine the stiffness of the pancreas in healthy volunteers. Materials and Methods Twenty healthy volunteers underwent 1.5 Tesla MRE exams using an accelerated echo planar imaging (EPI) pulse sequence with low‐frequency vibrations (40 and 60 Hz). Stiffness was calculated with a 3D direct inversion algorithm. The mean shear stiffness in five pancreatic subregions (uncinate, head, neck, body, and tail) and the corresponding liver stiffness were calculated. The intrasubject coefficient of variation (CV) was calculated as a measure of the reproducibility for each volunteer. Results The mean shear stiffness (average of values obtained in different pancreatic subregions) was (1.15 ± 0.17) kPa at 40 Hz, and (2.09 ± 0.33) kPa at 60 Hz. The corresponding liver stiffness was higher than the pancreas stiffness at 40 Hz ([1.60 ± 0.21] kPa, mean pancreas‐to‐liver stiffness ratio: 0.72), but similar at 60Hz ([2.12 ± 0.23) kPa, mean ratio: 0.95). The mean intrasubject CV for each pancreatic subregion was lower at 40 Hz than 60 Hz ( P < 0.05 for all subregions, range: 11.9–15.7% at 40 Hz and 16.5–19.6% at 60 Hz). Conclusion The 3D pancreatic MRE can provide promising and reproducible stiffness measurements throughout the pancreas, with more consistent data acquired at 40 Hz. J. Magn. Reson. Imaging 2015;41:369–375. © 2013 Wiley Periodicals, Inc .
Estimation of the absolute shear stiffness of human lung parenchyma using 1 H spin echo, echo planar MR elastography
Glaser, Kevin J. , Levin, David L. , Vassallo, Robert , Hubmayr, Rolf D., Mottram, Carl, McGee, Kiaran P. , Mariappan, Yogesh K. , Ehman, Richard L. , Vassallo, Robert

Journal of Magnetic Resonance Imaging | November 13, 2013 | Volume: 40 | Issue: 5 | Pages: 1230-1237

10.1002/jmri.24479 | PMID 24390975 Get It

Purpose To develop a rapid proton MR elastography (MRE) technique that can quantify the absolute shear stiffness of lung parenchyma, to investigate the ability to differentiate respiration‐dependent stiffness variations of the lung, and to demonstrate clinical feasibility. Materials and Methods A spin‐echo echo planar imaging MRE sequence (SE‐EPI MRE) with a very short echo time was developed and tested in a series of five healthy volunteers at three different lung volumes: (i) residual volume (RV), (ii) total lung capacity (TLC), (iii) and midway between RV and TLC (MID). At each volume, lung density was quantified using a MR‐based density mapping sequence. For reference, data were acquired using the previously described spin‐echo lung MRE sequence (SE‐MRE). MRE data were also acquired in a patient with proven Idiopathic Pulmonary Fibrosis (IPF) to test clinical feasibility. Results The SE‐EPIMRE sequence reduced total acquisition time by a factor of 2 compared with the SE‐MRE sequence. Lung parenchyma median shear stiffness for the 5 volunteers quantified with the SE‐EPI MRE sequence was 0.9 kPa, 1.1 kPa, and 1.6 kPa at RV, MID, and TLC, respectively. The corresponding values obtained with the SE‐MRE sequence were 0.9 kPa, 1.1 kPa, and 1.5 kPa. Absolute shear stiffness was also successfully measured in the IPF patient. Conclusion The results indicate that stiffness variations due to respiration could be measured with the SE‐EPIMRE technique and were equivalent to values generated by the previously described SE‐MRE approach. Preliminary data obtained from the patient demonstrate clinical feasibility. J. Magn. Reson. Imaging 2014;40:1230–1237 . © 2013 Wiley Periodicals, Inc .
Recent developments in the characterization of anisotropic, biological media utilizing magnetic resonance elastography
Romano, Anthony J., Valdivia, Nicolas , Abraham, Philip B., Bucaro, Joseph A., Rossman, Philip J., Ehman, Richard L.

The Journal of the Acoustical Society of America | October 23, 2013 | Volume: 117 | Issue: 4_Supplement | Pages: 2615-2615

10.1121/1.4778119 Get It

In this paper, we present recent developments in the characterization of anisotropic, biological media utilizing displacements measured with dynamic MRE. In one approach, a waveguide constrained analysis is applied to physical structures (such as muscle), which evaluates the velocities of wave propagation along arbitrarily oriented fibers or fiber bundles in a local fashion, utilizing a spectral filter and a sliding window, spatial Fourier transform. In a second approach, the anisotropic equations of elasticity, in variational form, are inverted for a determination of the complex moduli comprising the medium. Issues concerning ill-conditioning, the effects of boundary conditions, and multiaspect excitation requirements will be addressed, as well as a discussion concerning the models which are appropriate for various physical situations. These two complementary methods of analysis will be demonstrated utilizing both phantom as well as in vivo dynamic displacement measurements.
Magnetic resonance elastography
Ehman, Richard L. , Manduca, Armando

The Journal of the Acoustical Society of America | October 23, 2013 | Volume: 117 | Issue: 4_Supplement | Pages: 2587-2587

10.1121/1.4777170 Get It

The goal of our research is to develop MRI-based methods for assessing the mechanical properties of tissues in vivo. We have focused on a novel MRI technique for visualizing propagating acoustic shear waves [Science 269, 1854–1857 (1995)]. Suitable dynamic shear stress for Magnetic Resonance Elastography (MRE) can be generated by surface drivers, inertial effects, acoustic radiation pressure, or endogenous physiologic mechanisms. The MRE acquisition sequence is capable of visualizing cyclic tissue motion of less than 1 micron in displacement amplitude, with imaging times ranging from 100 ms to several minutes. Inversion algorithms based on continuum mechanics are used to process the acquired data to generate maps of mechanical properties such as depict stiffness, viscosity, attenuation, and anisotropic behavior. We have applied MRE to assess specimens of a variety of tissues, ranging in stiffness from lung to cartilage. Human studies have demonstrated that it is feasible to apply MRE to quantitatively image the mechanical properties of skeletal muscles, gray and white matter in the brain, thyroid, kidney, liver, and skin. Our preliminary clinical studies have to date applied MRE to observe changes in tissue mechanical properties in patients with breast, brain, and thyroid tumors, liver fibrosis, and diffuse diseases of skeletal muscle.
Magnetic Resonance Elastography of the Liver in Patients Status-Post Fontan Procedure: Feasibility and Preliminary Results
Serai, Suraj D. , Wallihan, Daniel B., Venkatesh, Sudhakar K. , Sticka, Joshua , Marino, Bradley S. , Podberesky, Daniel J. , Ehman, Richard L. , Campbell, Kathleen M , Venkatesh, Sudhakar K , Serai, Suraj D

Congenital Heart Disease | October 17, 2013 | Volume: 9 | Issue: 1 | Pages: 7-14

10.1111/chd.12144 | PMID 24134059 Get It

IC‐P‐177: MR elastography of frontotemporal dementia
Murphy, Matthew C. , Huston, John , Jones, David T. , Jack, Clifford R. , Boeve, Bradley F. , Ehman, Richard L.

Alzheimer's & Dementia | October 9, 2013 | Volume: 9 | Issue: 4S_Part_2 | Pages: No page available

10.1016/j.jalz.2013.05.174 Get It

P1–329: MR elastography of frontotemporal dementia
Murphy, Matthew C. , Huston, John , Jones, David T. , Jack, Clifford R. , Boeve, Bradley F. , Ehman, Richard L.

Alzheimer's & Dementia | October 9, 2013 | Volume: 9 | Issue: 4S_Part_7 | Pages: No page available

10.1016/j.jalz.2013.05.555 Get It

Assessment of in vivo laser ablation using MR elastography with an inertial driver
Woodrum, David A. , Glaser, Kevin J. , Murphy, Matthew C. , Gorny, Krzysztof R. , Chen, Jun , Ehman, Richard L.

Magnetic Resonance in Medicine | July 31, 2013 | Volume: 72 | Issue: 1 | Pages: 59-67

10.1002/mrm.24891 | PMID 23904298 Get It

MR elastography derived shear stiffness-a new imaging biomarker for the assessment of early tumor response to chemotherapy
Pepin, Kay , Glaser, Kevin J. , Mariappan, Yogesh K. , Reuland, Brian, Ziesmer, Steven C., Carter, Rickey E. , Ansell, Stephen M. , McGee, Kiaran P. , Chen, Jun , Ehman, Richard L. , Carter, Rickey E , Mariappan, Yogesh Kannan

Magnetic Resonance in Medicine | June 25, 2013 | Volume: 71 | Issue: 5 | Pages: 1834-1840

10.1002/mrm.24825 | PMID 23801372 Get It