Citations

Mayo Clinic

Clear

1899 citation(s) found for "Núñez, Sara".

Development and Application of Mass Spectroscopy Assays for Nε-(1-Carboxymethyl)-L-Lysine and Pentosidine in Renal Failure and Diabetes
O’Grady, Katherine , Bondar, Olga P., Atkinson, Elizabeth J. , Achenbach, Sara J., Eckhardt, Brittany, Thicke, Brianne S, Tweed, Amanda, Volkman, Tammie L., Hines, Jolaine M., O'Grady, Katherine L, Farr, Joshua N. , Eckhardt, Brittany A, Tweed, Amanda J, Drake, Matthew T. , Khosla, Sundeep , Singh, Ravinder J.

The Journal of Applied Laboratory Medicine | January 29, 2020 | Volume: 5 | Issue: 3 | Pages: 558-568

10.1093/jalm/jfaa023 | PMID 32445362 Get It

AbstractBackgroundAdvanced glycation end products (AGEs) are formed via the nonenzymatic glycation of sugars with amino acids. Two AGEs, Nε-(1-carboxymethyl)-L-Lysine (CML) and pentosidine, have been observed to be elevated in subjects suffering from a multitude of chronic disease states, and accumulation of these compounds may be related to the pathophysiology of disease progression and aging.MethodsWe describe here the development and validation of a specific and reproducible LC-MS/MS method to quantify CML and pentosidine in human serum with lower limits of quantitation of 75 ng/mL and 5 ng/mL, respectively. The analyte calibration curve exhibited excellent linearity at a range of 0–10 900 ng/mL for CML and 0–800 ng/mL for pentosidine. High-low linearity of 5 serum pairs was assessed, with a mean recovery of 103% (range 94—116%) for CML, and 104% (range 97—116%) for pentosidine.ResultsSerum concentrations of CML and pentosidine were quantified in 30 control and 30 subjects with chronic renal insufficiency. A significant increase in both analytes was observed in renal failure compared to control subjects (2.1-fold and 8.4-fold, respectively; P < 0.001 for both). In a separate cohort of 49 control versus 95 subjects with type 2 diabetes mellitus (T2DM), serum CML but not serum pentosidine, was significantly elevated in the T2DM patients, and CML was also correlated with glycemic control, as assessed by hemoglobin A1c (r = 0.34, P < 0.001).ConclusionsThese mass spectroscopy-based assays for serum CML and pentosidine should be useful in accurately evaluating circulating levels of these key AGEs in various disease states.
Spondylolysis in Young Athletes: An Overview Emphasizing Nonoperative Management
Goetzinger, Sara, Courtney, Selen, Yee, Kathy, Welz, Matthew E., Kalani, Maziyar A. , Neal, Matthew T. , Welz, Matthew, Kalani, Maziyar, Neal, Matthew

Journal of Sports Medicine | January 24, 2020 | Volume: 2020 | Issue: No issue available | Pages: 1-15

10.1155/2020/9235958 | PMID 32047822 Get It

Lumbar spondylolysis is a unilateral or bilateral defect of the pars interarticularis, an isthmus of bone connecting the superior and inferior facet surfaces in the lumbar spine at a given level. Spondylolysis is common in young athletes participating in sports, particularly those requiring repetitive hyperextension movements. The majority of young athletes are able to return to full sport participation following accurate diagnosis and conservative management, including a structured treatment program. Surgical intervention for isolated pars injuries is seldom necessary. A progressive physical therapy (PT) program is an important component of recovery after sustaining an acute pars fracture. However, there is a paucity of literature detailing PT programs specific to spondylolysis. Here, we provide an overview of the epidemiology, natural history, radiographic evaluation, and management of pars fractures in young athletes. In addition, a detailed description of a physiotherapy program for this population that was developed at a spine center within an academic medical center is provided.
Defining current gaps in quality measures for cancer immunotherapy: consensus report from the Society for Immunotherapy of Cancer (SITC) 2019 Quality Summit
Pai, Sara I. , Blaisdell, David, Brodie, R.R., Carlson, Robert W. , Finnes, Heidi D. , Galioto, Michele, Valuck, Tom , Sepulveda, Antonia R. , Finnes, Heidi, Brodie, Rachel, Jensen, Roxanne E. , Kaufman, Howard L.

Journal for ImmunoTherapy of Cancer | January 16, 2020 | Volume: 8 | Issue: 1 | Pages: e000112

10.1136/jitc-2019-000112 | PMID 31949040 Get It

Background Quality measures are important because they can help improve and standardize the delivery of cancer care among healthcare providers and across tumor types. In an environment characterized by a rapidly shifting immunotherapeutic landscape and lack of associated long-term outcome data, defining quality measures for cancer immunotherapy is a high priority yet fraught with many challenges. Methods Thus, the Society for Immunotherapy of Cancer convened a multistakeholder expert panel to, first, identify the current gaps in measures of quality cancer care delivery as it relates to immunotherapy and to, second, advance priority concepts surrounding quality measures that could be developed and broadly adopted by the field. Results After reviewing the existing quality measure landscape employed for immunotherapeutic-based cancer care, the expert panel identified four relevant National Quality Strategy domains (patient safety, person and family-centered care, care coordination and communication, appropriate treatment selection) with significant gaps in immunotherapy-based quality cancer care delivery. Furthermore, these domains offer opportunities for the development of quality measures as they relate to cancer immunotherapy. These four quality measure concepts are presented in this consensus statement. Conclusions This work represents a first step toward defining and standardizing quality delivery of cancer immunotherapy in order to realize its optimal application and benefit for patients.
Characteristics and quality of rotation-specific resident learning goals: a prospective study
Sawatsky, Adam P. , Halvorsen, Andrew J. , Daniels, Paul R. , Bonnes, Sara L. , Issa, Meltiady , Ratelle, John T. , Stephenson, Christopher R. , Beckman, Thomas J.

Medical Education Online | January 16, 2020 | Volume: 25 | Issue: 1 | Pages: No page available

10.1080/10872981.2020.1714198 | PMID 31941433 Get It

Deep inspirations attenuate postprandial airway inflammation in college-aged adults with elevated baseline exhaled nitric oxide: A pilot study
Kurti, Stephanie P. , Smith, Joshua R. , Rosenkranz, Sara K. , Emerson, Sam R. , Edwards, Elizabeth S. , Jurrens, Kayla, Laughlin, A., Kurti, S P , Edwards, E S , Smith, Joshua R , Harms, Craig A.

Experimental Lung Research | January 16, 2020 | Volume: 46 | Issue: 1-2 | Pages: 32-43

10.1080/01902148.2020.1713923 | PMID 31941389 Get It

An international multi-center serum protein electrophoresis accuracy and M-protein isotyping study. Part II: limit of detection and follow-up of patients with small M-proteins
Jacobs, Joannes F.M. , Turner, Katherine A., Graziani, Maria Stella , Frinack, Jody L. , Ettore, Michael, Tate, Jillian R., Booth, Ronald A. , McCudden, Christopher R. , Keren, David F. , Delgado, Julio C., Zemtsovskaja, Galina , Fullinfaw, Robert O., Caldini, Anna, Malmanche, Theo de , Katakouzinos, Katina, Burke, Matthew J. , Altinier, Sara, Zaninotto, Martina, Righetti, G, Melki, Marie Therese, Bell, Stephen C., Ettore, Michael W, Willrich, Maria Alice Vieira, Palladini, Giovanni , Melki, Marie‐Thérèse, Willrich, Maria Alice V.

Clinical Chemistry and Laboratory Medicine (CCLM) | January 15, 2020 | Volume: 58 | Issue: 4 | Pages: 547-559

10.1515/cclm-2019-1105 | PMID 31940285 Get It

Abstract Background Electrophoretic methods to detect, characterize and quantify M-proteins play an important role in the management of patients with monoclonal gammopathies (MGs). Significant uncertainty in the quantification and limit of detection (LOD) is documented when M-proteins are <10 g/L. Using spiked sera, we aimed to assess the variability in intact M-protein quantification and LOD across 16 laboratories. Methods Sera with normal, hypo- or hyper-gammaglobulinemia were spiked with daratumumab or elotuzumab, with concentrations from 0.125 to 10 g/L (n = 62) along with a beta-migrating sample (n = 9). Laboratories blindly analyzed samples according to their serum protein electrophoresis (SPEP)/isotyping standard operating procedures. LOD and intra-laboratory percent coefficient of variation (%CV) were calculated and further specified with regard to the method (gel/capillary electrophoresis [CZE]), gating strategy (perpendicular drop [PD]/tangent skimming [TS]), isotyping (immunofixation/immunosubtraction [ISUB]) and manufacturer (Helena/Sebia). Results All M-proteins ≥1 g/L were detected by SPEP. With isotyping the LOD was moderately more sensitive than with SPEP. The intensity of polyclonal background had the biggest negative impact on LOD. Independent of the method used, the intra-laboratory imprecision of M-protein quantification was small (mean CV = 5.0%). Low M-protein concentration and high polyclonal background had the strongest negative impact on intra-laboratory precision. All laboratories were able to follow trend of M-protein concentrations down to 1 g/L. Conclusions In this study, we describe a large variation in the reported LOD for both SPEP and isotyping; overall LOD is most affected by the polyclonal immunoglobulin background. Satisfactory intra-laboratory precision was demonstrated. This indicates that the quantification of small M-proteins to monitor patients over time is appropriate, when subsequent testing is performed within the same laboratory.
An international multi-center serum protein electrophoresis accuracy and M-protein isotyping study. Part I: factors impacting limit of quantitation of serum protein electrophoresis
Turner, Katherine A., Frinack, Jody L. , Ettore, Michael, Tate, Jillian R., Graziani, Maria Stella , Jacobs, Joannes F.M. , Booth, Ronald A. , McCudden, Christopher R. , Keren, David F. , Delgado, Julio C., Zemtsovskaja, Galina , Fullinfaw, Robert O., Caldini, Anna, Malmanche, Theo de , Katakouzinos, Katina, Burke, Matthew J. , Altinier, Sara, Zaninotto, Martina, Righetti, G, Melki, Marie Therese, Bell, Stephen C., Ettore, Michael W, Willrich, Maria Alice Vieira, Palladini, Giovanni , Melki, Marie‐Thérèse, Willrich, Maria Alice V.

Clinical Chemistry and Laboratory Medicine (CCLM) | January 15, 2020 | Volume: 58 | Issue: 4 | Pages: 533-546

10.1515/cclm-2019-1104 | PMID 31940284 Get It

Abstract Background Serum protein electrophoresis (SPEP) is used to quantify the serum monoclonal component or M-protein, for diagnosis and monitoring of monoclonal gammopathies. Significant imprecision and inaccuracy pose challenges in reporting small M-proteins. Using therapeutic monoclonal antibody-spiked sera and a pooled beta-migrating M-protein, we aimed to assess SPEP limitations and variability across 16 laboratories in three continents. Methods Sera with normal, hypo- or hypergammaglobulinemia were spiked with daratumumab, Dara (cathodal migrating), or elotuzumab, Elo (central-gamma migrating), with concentrations from 0.125 to 10 g/L (n = 62) along with a beta-migrating sample (n = 9). Provided with total protein (reverse biuret, Siemens), laboratories blindly analyzed samples according to their SPEP and immunofixation (IFE) or immunosubtraction (ISUB) standard operating procedures. Sixteen laboratories reported the perpendicular drop (PD) method of gating the M-protein, while 10 used tangent skimming (TS). A mean percent recovery range of 80%–120% was set as acceptable. The inter-laboratory %CV was calculated. Results Gamma globulin background, migration pattern and concentration all affect the precision and accuracy of quantifying M-proteins by SPEP. As the background increases, imprecision increases and accuracy decreases leading to overestimation of M-protein quantitation especially evident in hypergamma samples, and more prominent with PD. Cathodal migrating M-proteins were associated with less imprecision and higher accuracy compared to central-gamma migrating M-proteins, which is attributed to the increased gamma background contribution in M-proteins migrating in the middle of the gamma fraction. There is greater imprecision and loss of accuracy at lower M-protein concentrations. Conclusions This study suggests that quantifying exceedingly low concentrations of M-proteins, although possible, may not yield adequate accuracy and precision between laboratories.
Letter: Nonepileptic, Stereotypical, and Intermittent Symptoms (NESIS) in Patients With Subdural Hematoma: Proposal for a New Clinical Entity With Therapeutic and Prognostic Implications
Marcellino, Chris , Gompel, Jaime J Van, Hocker, Sara E. , Gompel, Jamie J. Van , Van Gompel, Jaime J, Hocker, Sara, Van Gompel, Jamie J , Marcellino, Christopher

Neurosurgery | January 9, 2020 | Volume: 86 | Issue: 5 | Pages: E484-E484

10.1093/neuros/nyaa010 | PMID 31980823 Get It

Sex-Specific 99th Percentile Upper Reference Limits for High Sensitivity Cardiac Troponin Assays Derived Using a Universal Sample Bank
Apple, Fred S. , Wu, Alan H.B. , Sandoval, Yader , Sexter, Anne, Love, Sara A., Myers, Gary L., Schulz, Karen , Duh, Show‐Hong, Christenson, Robert H.

Clinical Chemistry | January 2, 2020 | Volume: 66 | Issue: 3 | Pages: 434-444

10.1093/clinchem/hvz029 | PMID 32109298 Get It

Abstract Background How to select healthy reference subjects in deriving 99th percentiles for cardiac troponin assays still needs to be clarified. To assist with global implementation of high sensitivity (hs)-cardiac troponin (cTn) I and hs-cTnT assays in clinical practice, we determined overall and sex-specific 99th percentiles in 9 hs-cTnI and 3 hs-cTnT assays using a universal sample bank (USB). Methods The Universal Sample Bank (USB) comprised healthy subjects, 426 men and 417 women, screened using a health questionnaire. Hemoglobin A1c (&gt;URL 6.5%), NT-proBNP (&gt;URL 125 ng/L) and eGFR (&lt;60 mL/min), were used as surrogate biomarker exclusion criteria along with statin use. 99th percentiles were determined by nonparametric, Harrell--Davis bootstrap, and robust methods. Results Subjects were ages 19 to 91 years, Caucasian 58%, African American 27%, Pacific Islander/Asian 11%, other 4%, Hispanic 8%, and non-Hispanic 92%. The overall and sex-specific 99th percentiles for all assays, before and after exclusions (n = 694), were influenced by the statistical method used, with substantial differences noted between and within both hs-cTnI and hs-cTnT assays. Men had higher 99th percentiles (ng/L) than women. The Roche cTnT and Beckman and Abbott cTnI assays (after exclusions) did not measure cTn values at ≥ the limit of detection in ≥50% women. Conclusions Our findings have important clinical implications in that sex-specific 99th percentiles varied according to the statistical method and hs-cTn assay used, not all assays provided a high enough percentage of measurable concentrations in women to qualify as a hs-assay, and the surrogate exclusion criteria used to define normality tended to lower the 99th percentiles.