Back to Authors

O'Grady, Katherine L

Mayo Clinic

Mayo Clinic College of Medicine, Rochester, MN.

Citations 2

Chemical Characterization and Quantification of Circulating Intact PTH and PTH Fragments by High-Resolution Mass Spectrometry in Chronic Renal Failure
Kritmetapak, Kittrawee , Losbanos, Louis, Hines, Jolaine M., O’Grady, Katherine , Ulmer, Candice Z. , Vesper, Hubert W. , Losbanos, Louis A, O'Grady, Katherine L, Enders, Felicity T, Enders, Felicity , Singh, Ravinder J. , Kumar, Rajiv

Clinical Chemistry | January 20, 2021 | Volume: 67 | Issue: 6 | Pages: 843-853

10.1093/clinchem/hvab013 Get It

Abstract Background The precise concentrations of full-length parathyroid hormone (PTH1-84) and the identity and concentrations of PTH fragments in patients with various stages of chronic renal failure are unknown. Methods We developed a liquid chromatography-high resolution mass spectrometry (LC-HRMS) method to characterize and quantify PTH1-84 and PTH fragments in serum of 221 patients with progressive renal dysfunction. Following capture by matrix-bound amino-terminal or carboxyl-terminal region-specific antibodies and elution from matrix, PTH1-84 and PTH fragments were identified and quantitated using LC-HRMS. PTH was simultaneously measured using an intact PTH (iPTH) immunoassay. Results Full-length PTH1-84 and 8 PTH fragments (PTH28-84, 34-77, 34-84, 37-77, 37-84, 38-77, 38-84, and 45-84) were unequivocally identified and were shown to increase significantly when an eGFR declined to ≤17-23 mL/min/1.73m2. Serum concentrations of PTH1-84 were similar when measured by LC-HRMS following capture by amino-terminal or carboxyl-terminal immunocapture methods. In patients with an eGFR of <30 mL/min/1.73 m2, serum PTH concentrations measured using LC-HRMS were significantly lower than PTH measured using an iPTH immunoassay. PTH7-84 and oxidized forms of PTH1-84 were below the limit of detection (30 and 50 pg/mL, respectively). Conclusions LC-HRMS identifies circulating PTH1-84, carboxyl-terminal PTH fragments, and mid-region PTH fragments, in patients with progressive renal failure. Serum PTH1-84 and its fragments markedly rise when an eGFR decreases to ≤17-23 mL/min/1.73 m2. PTH concentrations measured using LC-HRMS tend to be lower than those measured using an iPTH immunoassay, particularly in severe chronic renal failure. Our data do not support the existence of circulating PTH7-84 and oxidized PTH1-84.
Development and Application of Mass Spectroscopy Assays for Nε-(1-Carboxymethyl)-L-Lysine and Pentosidine in Renal Failure and Diabetes
O’Grady, Katherine , Bondar, Olga P., Atkinson, Elizabeth J. , Achenbach, Sara J., Eckhardt, Brittany, Thicke, Brianne S, Tweed, Amanda, Volkman, Tammie L., Hines, Jolaine M., O'Grady, Katherine L, Farr, Joshua N. , Eckhardt, Brittany A, Tweed, Amanda J, Drake, Matthew T. , Khosla, Sundeep , Singh, Ravinder J.

The Journal of Applied Laboratory Medicine | January 29, 2020 | Volume: 5 | Issue: 3 | Pages: 558-568

10.1093/jalm/jfaa023 Get It

AbstractBackgroundAdvanced glycation end products (AGEs) are formed via the nonenzymatic glycation of sugars with amino acids. Two AGEs, Nε-(1-carboxymethyl)-L-Lysine (CML) and pentosidine, have been observed to be elevated in subjects suffering from a multitude of chronic disease states, and accumulation of these compounds may be related to the pathophysiology of disease progression and aging.MethodsWe describe here the development and validation of a specific and reproducible LC-MS/MS method to quantify CML and pentosidine in human serum with lower limits of quantitation of 75 ng/mL and 5 ng/mL, respectively. The analyte calibration curve exhibited excellent linearity at a range of 0–10 900 ng/mL for CML and 0–800 ng/mL for pentosidine. High-low linearity of 5 serum pairs was assessed, with a mean recovery of 103% (range 94—116%) for CML, and 104% (range 97—116%) for pentosidine.ResultsSerum concentrations of CML and pentosidine were quantified in 30 control and 30 subjects with chronic renal insufficiency. A significant increase in both analytes was observed in renal failure compared to control subjects (2.1-fold and 8.4-fold, respectively; P < 0.001 for both). In a separate cohort of 49 control versus 95 subjects with type 2 diabetes mellitus (T2DM), serum CML but not serum pentosidine, was significantly elevated in the T2DM patients, and CML was also correlated with glycemic control, as assessed by hemoglobin A1c (r = 0.34, P < 0.001).ConclusionsThese mass spectroscopy-based assays for serum CML and pentosidine should be useful in accurately evaluating circulating levels of these key AGEs in various disease states.