Back to Authors

Bondar, Olga P.

Mayo Clinic

Immunochemical Core Laboratory,

Citations 7

Accelerated osteocyte senescence and skeletal fragility in mice with type 2 diabetes
Eckhardt, Brittany, Rowsey, Jennifer L. , Thicke, Brianne S, Fraser, Daniel G., O’Grady, Katherine , Bondar, Olga P., Hines, Jolaine M., Thoreson, Andrew R. , Rakshit, Kuntol, Lagnado, Anthony B. , Passos, João F. , Matveyenko, Aleksey V. , Farr, Joshua N. , Passos, João F , Singh, Ravinder , Vella, Adrian , Khosla, Sundeep , Monroe, David G.

JCI Insight | April 8, 2020 | Volume: 5 | Issue: 9 | Pages: No page available

10.1172/jci.insight.135236 Get It

The worldwide prevalence of type 2 diabetes (T2D) is increasing. Despite normal to higher bone density, patients with T2D paradoxically have elevated fracture risk resulting, in part, from poor bone quality. Advanced glycation endproducts (AGEs) and inflammation as a consequence of enhanced receptor for AGE (RAGE) signaling are hypothesized culprits, although the exact mechanisms underlying skeletal dysfunction in T2D are unclear. Lack of inducible models that permit environmental (in obesity) and temporal (after skeletal maturity) control of T2D onset has hampered progress. Here, we show in C57BL/6 mice that a onetime pharmacological intervention (streptozotocin, STZ) initiated in adulthood combined with high-fat diet–induced (HFD-induced) obesity caused hallmark features of human adult-onset T2D, including prolonged hyperglycemia, insulin resistance, and pancreatic β cell dysfunction, but not complete destruction. In addition, HFD/STZ (i.e., T2D) resulted in several changes in bone quality that closely mirror those observed in humans, including compromised bone microarchitecture, reduced biomechanical strength, impaired bone material properties, altered bone turnover, and elevated levels of the AGE CML in bone and blood. Furthermore, T2D led to the premature accumulation of senescent osteocytes with a unique proinflammatory signature. These findings highlight the RAGE pathway and senescent cells as potential targets to treat diabetic skeletal fragility.
Development and Application of Mass Spectroscopy Assays for Nε-(1-Carboxymethyl)-L-Lysine and Pentosidine in Renal Failure and Diabetes
O’Grady, Katherine , Bondar, Olga P., Atkinson, Elizabeth J. , Achenbach, Sara J., Eckhardt, Brittany, Thicke, Brianne S, Tweed, Amanda, Volkman, Tammie L., Hines, Jolaine M., O'Grady, Katherine L, Farr, Joshua N. , Eckhardt, Brittany A, Tweed, Amanda J, Drake, Matthew T. , Khosla, Sundeep , Singh, Ravinder J.

The Journal of Applied Laboratory Medicine | January 29, 2020 | Volume: 5 | Issue: 3 | Pages: 558-568

10.1093/jalm/jfaa023 Get It

AbstractBackgroundAdvanced glycation end products (AGEs) are formed via the nonenzymatic glycation of sugars with amino acids. Two AGEs, Nε-(1-carboxymethyl)-L-Lysine (CML) and pentosidine, have been observed to be elevated in subjects suffering from a multitude of chronic disease states, and accumulation of these compounds may be related to the pathophysiology of disease progression and aging.MethodsWe describe here the development and validation of a specific and reproducible LC-MS/MS method to quantify CML and pentosidine in human serum with lower limits of quantitation of 75 ng/mL and 5 ng/mL, respectively. The analyte calibration curve exhibited excellent linearity at a range of 0–10 900 ng/mL for CML and 0–800 ng/mL for pentosidine. High-low linearity of 5 serum pairs was assessed, with a mean recovery of 103% (range 94—116%) for CML, and 104% (range 97—116%) for pentosidine.ResultsSerum concentrations of CML and pentosidine were quantified in 30 control and 30 subjects with chronic renal insufficiency. A significant increase in both analytes was observed in renal failure compared to control subjects (2.1-fold and 8.4-fold, respectively; P < 0.001 for both). In a separate cohort of 49 control versus 95 subjects with type 2 diabetes mellitus (T2DM), serum CML but not serum pentosidine, was significantly elevated in the T2DM patients, and CML was also correlated with glycemic control, as assessed by hemoglobin A1c (r = 0.34, P < 0.001).ConclusionsThese mass spectroscopy-based assays for serum CML and pentosidine should be useful in accurately evaluating circulating levels of these key AGEs in various disease states.
Serum Concentrations of Prostate-Specific Antigen Measured Using Immune Extraction, Trypsin Digestion, and Tandem Mass Spectrometry Quantification of LSEPAELTDAVK Peptide
Klee, Eric W. , Bondar, Olga P., Goodmanson, Marcia K., Trushin, Sergey A., Bergstralh, Eric J., Anderson, N. Leigh , Klee, George G., Singh, Ravinder J.

Archives of Pathology and Laboratory Medicine | September 30, 2014 | Volume: 138 | Issue: 10 | Pages: 1381-1386

10.5858/arpa.2013-0462-oa Get It

Context.— Prostate-specific antigen (PSA) is a 34-kDa glycoprotein with chymotrypsin-like enzyme activity that circulates both in free forms and complexed to various enzyme inhibitors including antichymotrypsin and α 2 -macroglobulin. Prostate-specific antigen bound to α 2 -macroglobulin is not detected by commercial PSA immunoassays. Objective.— To develop a mass spectrometry assay that detects the same forms of PSA as the immunoassays, which could serve as a reference for harmonizing PSA immunoassays. Design.— Prostate-specific antigen was immune extracted from serum, trypsin was digested, and the LSEPAELTDAVK peptide was quantitated on an API 5000 spectrometer. Calibrators were made by adding 10% free and 90% antichymotrypsin-bound PSA to female sera. The assay was standardized to the World Health Organization 96/670 reference standard. Validation of clinical utility and comparisons with 2 immunoassays (Roche cobas and Beckman Access) were performed using frozen sera aliquots from 100 men undergoing prostate biopsy (50 negative, 50 with cancer) and 5 serial samples collected over time from 5 men with advanced prostate cancer. Results.— The antibody extraction efficiency was greater than 99%. The assay has an analytic range from 1.2 to 76 ng/mL, with precision ranging from 8.6% at 1.5 ng/mL to 5.4% at 27 ng/mL. The mass spectrometry assay correlated well with 2 immunoassays. All 3 assays showed statistically equivalent separation of prostate cancer from benign disease using receiver operating characteristic curve analysis. Conclusions.— This mass spectrometry assay can reliably measure PSA concentrations in human serum and could serve as a reference standard for harmonizing PSA immunoassays.
Mass Spectrometry Measurements of Prostate-Specific Antigen (PSA) Peptides Derived From Immune-Extracted PSA Provide a Potential Strategy for Harmonizing Immunoassay Differences
Klee, Eric W. , Bondar, Olga P., Goodmanson, Marcia K., Trushin, Sergey A., Anderson, N. Leigh , Klee, George G., Singh, Ravinder J.

American Journal of Clinical Pathology | March 11, 2014 | Volume: 141 | Issue: 4 | Pages: 527-533

10.1309/ajcp8pel0yxahdvk Get It

Immunological and Mass Spectrometric Assays of SHBG: Consistent and Inconsistent Metabolic Associations in Healthy Men
Veldhuis, Johannes D. , Bondar, Olga P., Dyer, Roy B. , Trushin, Sergey A., Klee, Eric W. , Klee, George G., Singh, Ravinder J.

The Journal of Clinical Endocrinology & Metabolism | November 8, 2013 | Volume: 99 | Issue: 1 | Pages: 184-193

10.1210/jc.2013-2642 Get It

Candidate Serum Biomarkers for Prostate Adenocarcinoma Identified by mRNA Differences in Prostate Tissue and Verified with Protein Measurements in Tissue and Blood
Klee, Eric W. , Bondar, Olga P., Goodmanson, Marcia K., Dyer, Roy B. , Erdoğan, Sibel , Bergstralh, Eric J., H., Robert Bergen, Sebo, Thomas J., Klee, George G.

Clinical Chemistry | January 13, 2012 | Volume: 58 | Issue: 3 | Pages: 599-609

10.1373/clinchem.2011.171637 Get It

Abstract BACKGROUND Improved tests are needed for detection and management of prostate cancer. We hypothesized that differential gene expression in prostate tissue could help identify candidate blood biomarkers for prostate cancer and that blood from men with advanced prostate disease could be used to verify the biomarkers presence in circulation. METHODS We identified candidate markers using mRNA expression patterns from laser-capture microdissected prostate tissue and confirmed tissue expression using immunohistochemistry (IHC) for the subset of candidates having commercial antisera. We analyzed tissue extracts with tandem mass spectrometry (MS/MS) and measured blood concentrations using immunoassays and MS/MS of trypsin-digested, immunoextracted peptides. RESULTS We selected 35 novel candidate prostate adenocarcinoma biomarkers. For all 13 markers having commercial antisera for IHC, tissue expression was confirmed; 6 showed statistical discrimination between nondiseased and malignant tissue, and only 5 were detected in tissue extracts by MS/MS. Sixteen of the 35 candidate markers were successfully assayed in blood. Four of 8 biomarkers measured by ELISA and 3 of 10 measured by targeted MS showed statistically significant increases in blood concentrations of advanced prostate cancer cases, compared with controls. CONCLUSIONS Seven novel biomarkers identified by gene expression profiles in prostate tissue were shown to have statistically significant increased concentrations in blood from men with advanced prostate adenocarcinoma compared with controls: apolipoprotein C1, asporin, cartilage oligomeric matrix protein, chemokine (C-X-C motif) ligand 11 (CXCL11), CXCL9, coagulation factor V, and proprotein convertase subtilisin/kexin 6.
LC-MS/MS Quantification of Zn-α2 Glycoprotein: A Potential Serum Biomarker for Prostate Cancer
Bondar, Olga P., Barnidge, David R. , Klee, Eric W. , Davis, Brian J. , Klee, George G., Davis, Brian J

Clinical Chemistry | February 23, 2007 | Volume: 53 | Issue: 4 | Pages: 673-678

10.1373/clinchem.2006.079681 Get It

AbstractBackground: Zn-α2 glycoprotein (ZAG) is a relatively abundant glycoprotein that has potential as a biomarker for prostate cancer. We present a high-flow liquid chromatography–tandem mass spectrometry (LC-MS/MS) method for measuring serum ZAG concentrations by proteolytic cleavage of the protein and quantification of a unique peptide.Methods: We selected the ZAG tryptic peptide 147EIPAWVPEDPAAQITK162 as the intact protein for quantification and used a stable isotope-labeled synthetic peptide with this sequence as an internal standard. Standards using recombinant ZAG in bovine serum albumin, 50 g/L, and a pilot series of patient sera were denatured, reduced, alkylated, and digested with trypsin. The concentration of ZAG was calculated from a dose–response curve of the ratio of the relative abundance of the ZAG tryptic peptide to internal standard.Results: The limit of detection for ZAG in serum was 0.08 mg/L, and the limit of quantification was 0.32 mg/L with a linear dynamic range of 0.32 to 10.2 mg/L. Replicate digests from pooled sera run during a period of 3 consecutive days showed intraassay imprecision (CV) of 5.0% to 6.3% and interassay imprecision of 4.4% to 5.9%. Mean (SD) ZAG was higher in 25 men with prostate cancer [7.59 (2.45) mg/L] than in 20 men with nonmalignant prostate disease [6.21 (1.65) mg/L, P = 0.037] and 6 healthy men [3.65 (0.71) mg/L, P = 0.0007].Conclusions: This LC-MS/MS assay is reproducible and can be used to evaluate the clinical utility of ZAG as a cancer biomarker.