Citations

Mayo Clinic

Clear

155 citation(s) found for "Wu, Herman".

Accumulation of 5-oxoproline in myocardial dysfunction and the protective effects of OPLAH
Pol, Atze van der , Gil, Andrés , Silljé, Herman H.W. , Tromp, Jasper , Ovchinnikova, Ekaterina S. , Vreeswijk‐Baudoin, Inge, Hoes, Martijn F. , Domian, Ibrahim J., Sluis, Bart van de , Deursen, Jan M. van , Veldhuisen, Dirk J. van , Gilst, Wiek H. van , Berezikov, Eugène , Harst, Pim van der , Boer, Rudolf A. de , Bischoff, Rainer , Meer, Peter van der , van der Pol, Atze , van Deursen, Jan M , van Gilst, Wiek H , Berezikov, Eugene , van der Harst, Pim , de Boer, Rudolf A , Bischoff, Rainer , van der Meer, Peter , van de Sluis, Bart , Voors, Adriaan A.

Science Translational Medicine | November 8, 2017 | Volume: 9 | Issue: 415 | Pages: No page available

10.1126/scitranslmed.aam8574 | PMID 29118264 Get It

OPLAH is cardioprotective for myocardial infarction, and its substrate 5-oxoproline is a putative circulating marker for heart failure.
Microdosimetric measurements of a clinical proton beam with micrometer‐sized solid‐state detector
Anderson, Sarah , Tran, Linh T. , Chartier, Lachlan, Petasecca, Marco , Lerch, Michael , Prokopovich, Dale A., Reinhard, Mark I., Perevertaylo, Vladimir L. , Rosenfeld, Anatoly , Herman, Michael , Beltran, Chris , Anderson, Sarah E, Furutani, Keith M. , Herman, Michael G., Rosenfeld, A B , Beltran, Chris J , Anderson, Sarah E.

Medical Physics | September 14, 2017 | Volume: 44 | Issue: 11 | Pages: 6029-6037

10.1002/mp.12583 | PMID 28905399 Get It

PurposeMicrodosimetry is a vital tool for assessing the microscopic patterns of energy deposition by radiation, which ultimately govern biological effect. Solid‐state, silicon‐on‐insulator microdosimeters offer an approach for making microdosimetric measurements with high spatial resolution (on the order of tens of micrometers). These high‐resolution, solid‐state microdosimeters may therefore play a useful role in characterizing proton radiotherapy fields, particularly for making highly resolved measurements within the Bragg peak region. In this work, we obtain microdosimetric measurements with a solid‐state microdosimeter (MicroPlus probe) in a clinical, spot‐scanning proton beam of small spot size.MethodsThe MicroPlus probe had a 3D single sensitive volume on top of silicon oxide. The sensitive volume had an active cross‐sectional area of 250 μm × 10 μm and thickness of 10 μm. The proton facility was a synchrotron‐based, spot‐scanning system with small spot size (σ ≈ 2 mm). We performed measurements with the clinical beam current (≈1 nA) and had no detected pulse pile‐up. Measurements were made in a water‐equivalent phantom in water‐equivalent depth (WED) increments of 0.25 mm or 1.0 mm along pristine Bragg peaks of energies 71.3 MeV and 159.9 MeV, respectively. For each depth, we measured lineal energy distributions and then calculated the dose‐weighted mean lineal energy, . The measurements were repeated for two field sizes: 4 × 4 cm2 and 20 × 20 cm2.ResultsFor both 71.3 MeV and 159.9 MeV and for both field sizes, increased with depth toward the distal edge of the Bragg peak, a result consistent with Monte Carlo calculations and measurements performed elsewhere. For the 71.3 MeV, 4 × 4 cm2 beam (range at 80% distal falloff, R80 = 3.99 cm), we measured keV/μm at WED = 2 cm, and keV/μm at WED = 3.95 cm. For the 71.3 MeV, 20 × 20 cm2 beam, we measured keV/μm at WED = 2.6 cm, and keV/μm at WED = 3 cm. For the 159.9 MeV, 4 × 4 cm2 beam (R80 = 17.7 cm), keV/μm at WED = 5 cm, and keV/μm at WED = 17.6 cm. For the 159.9 MeV, 20 × 20 cm2 beam, keV/μm at WED = 5 cm, and keV/μm at WED = 17.6 cm.ConclusionsWe performed microdosimetric measurements with a novel solid‐state, silicon‐on‐insulator microdosimeter in a clinical spot‐scanning proton beam of small spot size and unmodified beam current. For all of the proton field sizes and energies considered, the measurements of were in agreement with expected trends. Furthermore, we obtained measurements with a spatial resolution of 10 μm in the beam direction. This spatial resolution greatly exceeded that possible with a conventional gaseous tissue‐equivalent proportional counter and allowed us to perform a high‐resolution investigation within the Bragg peak region. The MicroPlus probe is therefore suitable for applications in proton radiotherapy.
Technical Note: Using experimentally determined proton spot scanning timing parameters to accurately model beam delivery time
Shen, Jiajian , Tryggestad, E., Younkin, James E. , Keole, Sameer R., Kang, Yixiu, Herman, Michael , Bues, Martin , Tryggestad, Erik, Furutani, Keith M. , Herman, Michael G., Shen, Jiajian , Bues, Martin

Medical Physics | August 4, 2017 | Volume: 44 | Issue: 10 | Pages: 5081-5088

10.1002/mp.12504 | PMID 28777447 Get It

PurposeTo accurately model the beam delivery time (BDT) for a synchrotron‐based proton spot scanning system using experimentally determined beam parameters.MethodsA model to simulate the proton spot delivery sequences was constructed, and BDT was calculated by summing times for layer switch, spot switch, and spot delivery. Test plans were designed to isolate and quantify the relevant beam parameters in the operation cycle of the proton beam therapy delivery system. These parameters included the layer switch time, magnet preparation and verification time, average beam scanning speeds in x‐ and y‐directions, proton spill rate, and maximum charge and maximum extraction time for each spill. The experimentally determined parameters, as well as the nominal values initially provided by the vendor, served as inputs to the model to predict BDTs for 602 clinical proton beam deliveries. The calculated BDTs (TBDT) were compared with the BDTs recorded in the treatment delivery log files (TLog): ∆t = TLog−TBDT.ResultsThe experimentally determined average layer switch time for all 97 energies was 1.91 s (ranging from 1.9 to 2.0 s for beam energies from 71.3 to 228.8 MeV), average magnet preparation and verification time was 1.93 ms, the average scanning speeds were 5.9 m/s in x‐direction and 19.3 m/s in y‐direction, the proton spill rate was 8.7 MU/s, and the maximum proton charge available for one acceleration is 2.0 ± 0.4 nC. Some of the measured parameters differed from the nominal values provided by the vendor. The calculated BDTs using experimentally determined parameters matched the recorded BDTs of 602 beam deliveries (∆t = −0.49 ± 1.44 s), which were significantly more accurate than BDTs calculated using nominal timing parameters (∆t = −7.48 ± 6.97 s).ConclusionsAn accurate model for BDT prediction was achieved by using the experimentally determined proton beam therapy delivery parameters, which may be useful in modeling the interplay effect and patient throughput. The model may provide guidance on how to effectively reduce BDT and may be used to identifying deteriorating machine performance.
Early‐life decline in neurogenesis markers and age‐related changes of TrkB splice variant expression in the human subependymal zone
Weissleder, Christin , Kondo, Mari , Yang, Chunhui , Fung, Samantha J., Rothmond, Debora A. , Wong, Matthew Wai Kin , Halliday, Glenda M. , Herman, Mary M., Weickert, Cynthia Shannon , Kleinman, Joel E , Webster, Maree J. , Halliday, Glenda , Weissleder, Christin

European Journal of Neuroscience | June 14, 2017 | Volume: 46 | Issue: 2 | Pages: 1768-1778

10.1111/ejn.13623 | PMID 28612959 Get It

AbstractNeurogenesis in the subependymal zone (SEZ) declines across the human lifespan, and reduced local neurotrophic support is speculated to be a contributing factor. While tyrosine receptor kinase B (TrkB) signalling is critical for neuronal differentiation, maturation and survival, little is known about subependymal TrkB expression changes during postnatal human life. In this study, we used quantitative PCR and in situ hybridisation to determine expression of the cell proliferation marker Ki67, the immature neuron marker doublecortin (DCX) and both full‐length (TrkB‐TK+) and truncated TrkB receptors (TrkB‐TK‐) in the human SEZ from infancy to middle age (n = 26–35, 41 days to 43 years). We further measured TrkB‐TK+ and TrkB‐TK‐ mRNAs in the SEZ from young adulthood into ageing (n = 50, 21–103 years), and related their transcript levels to neurogenic and glial cell markers. Ki67, DCX and both TrkB splice variant mRNAs significantly decreased in the SEZ from infancy to middle age. In contrast, TrkB‐TK‐ mRNA increased in the SEZ from young adulthood into ageing, whereas TrkB‐TK+ mRNA remained stable. TrkB‐TK‐ mRNA positively correlated with expression of neural precursor (glial fibrillary acidic protein delta and achaete‐scute homolog 1) and glial cell markers (vimentin and pan glial fibrillary acidic protein). TrkB‐TK+ mRNA positively correlated with expression of neuronal cell markers (DCX and tubulin beta 3 class III). Our results indicate that cells residing in the human SEZ maintain their responsiveness to neurotrophins; however, this capability may change across postnatal life. We suggest that TrkB splice variants may differentially influence neuronal and glial differentiation in the human SEZ.
Meeting Report of the Fifth International Cancer Epigenetics Conference in Beijing, China, October 2016
Gao, Dan , Herman, James G. , Cui, Hengmi , Jen, Jin , Fuks, François , Brock, Malcolm V., Ushijima, Toshikazu , Guo, Mingzhou , Croce, Carlo Maria , Akiyama, Yoshimitsu

Epigenomics | May 22, 2017 | Volume: 9 | Issue: 7 | Pages: 937-941

10.2217/epi-2017-0030 | PMID 28530839 Get It

External Arrhythmia Ablation Using Photon Beams
Deisher, A., Takami, Mitsuru , Kruse, Jon J. , Song, Limin, Anderson, Sarah , Cusma, Jack T., Parker, Kay D., Johnson, Susan B., Asirvatham, Samuel J. , Miller, Robert C. , Herman, Michael , Packer, Douglas L. , Lehmann, H. Immo , Deisher, Amanda J, Anderson, Sarah E, Herman, Michael G., Asirvatham, Samuel J

Circulation: Arrhythmia and Electrophysiology | April 13, 2017 | Volume: 10 | Issue: 4 | Pages: No page available

10.1161/circep.116.004304 | PMID 28408649 Get It

Background— This study sought to investigate external photon beam radiation for catheter-free ablation of the atrioventricular junction in intact pigs. Methods and Results— Ten pigs were randomized to either sham irradiation or irradiation of the atrioventricular junction (55, 50, 40, and 25 Gy). Animals underwent baseline electrophysiological evaluation, cardiac gated multi-row computed tomographic imaging for beam delivery planning, and intensity-modulated radiation therapy. Doses to the coronary arteries were optimized. Invasive follow-up was conducted ≤4 months after the irradiation. A mean volume of 2.5±0.5 mL was irradiated with target dose. The mean follow-up length after irradiation was 124.8±30.8 days. Out of 7 irradiated animals, complete atrioventricular block was achieved in 6 animals of all 4 dose groups (86%). Using the same targeting margins, ablation lesion size notably increased with the delivered dose because of volumetric effects of isodose lines around the target volume. The mean macroscopically calculated atrial lesion volume for all 4 dose groups was 3.8±1.1 mL, lesions extended anteriorly into the interventricular septum. No short-term side effects were observed. No damage was observed in the tissues of the esophagus, phrenic nerves, or trachea. However, histology revealed in-field beam effects outside of the target volume. Conclusions— Single-fraction doses as low as 25 Gy caused a lesion with interruption of cardiac impulse propagation using this respective target volume. With doses of ≤55 Gy, maximal point-doses to coronary arteries could be kept <7Gy, but target conformity of lesions was not fully achieved using this approach.
2016 American College of Rheumatology/European League Against Rheumatism Criteria for Minimal, Moderate, and Major Clinical Response in Adult Dermatomyositis and Polymyositis: An International Myositis Assessment and Clinical Studies Group/Paediatric Rheum
Rider, Lisa G. , Ruperto, Nicolino , Bayat, Nastaran, Amato, Anthony A. , Dastmalchi, Maryam, Katz, James D. , Mammen, Andrew L. , Visser, Marianne de, Ytterberg, Steven R. , Lundberg, Ingrid E. , Chung, Lorinda, Dankó, Katalin , Torre, Ignacio García‐De La , Villa, Luca, Rinaldi, Mariangela, Rockette, Howard E., Lachenbruch, Peter A., Miller, Frederick W. , Vencovský, Jiří , Rouster‐Stevens, Kelly , Huber, Adam M. , Selva-O’Callaghan, Albert , Rutkove, Seward B. , Dimachkie, Mazen M. , Olesińska, Marzena , Chung, Leland W.K. , Shinjo, Samuel Katsuyuki , Ramchandren, Sindhu , Saketkoo, Lesley Ann , Mann, H. , Aggarwal, Rohit , Erman, Brian , Feldman, Brian Michael , Oddis, Chester V. , Chinoy, Hector , Cooper, Robert G. , Fiorentino, David Franklin , Isenberg, David , Visser, Marianne de, Chung, Lorinda, Song, Yeong Wook , Mann, Heřman , Vencovsky, Jiri , Shinjo, Samuel Katsuyuki , Selva O'Callaghan, Albert , Chung, Lorinda , García-De La Torre, Ignacio , Dimachkie, Mazen M , Lundberg, Ingrid E , Pistorio, Angela

Arthritis & Rheumatology | April 6, 2017 | Volume: 69 | Issue: 5 | Pages: 898-910

10.1002/art.40064 | PMID 28382787 Get It

ObjectiveTo develop response criteria for adult dermatomyositis (DM) and polymyositis (PM).MethodsExpert surveys, logistic regression, and conjoint analysis were used to develop 287 definitions using core set measures. Myositis experts rated greater improvement among multiple pairwise scenarios in conjoint analysis surveys, where different levels of improvement in 2 core set measures were presented. The PAPRIKA (Potentially All Pairwise Rankings of All Possible Alternatives) method determined the relative weights of core set measures and conjoint analysis definitions. The performance characteristics of the definitions were evaluated on patient profiles using expert consensus (gold standard) and were validated using data from a clinical trial. The nominal group technique was used to reach consensus.ResultsConsensus was reached for a conjoint analysis–based continuous model using absolute percent change in core set measures (physician, patient, and extramuscular global activity, muscle strength, Health Assessment Questionnaire, and muscle enzyme levels). A total improvement score (range 0–100), determined by summing scores for each core set measure, was based on improvement in and relative weight of each core set measure. Thresholds for minimal, moderate, and major improvement were ≥20, ≥40, and ≥60 points in the total improvement score. The same criteria were chosen for juvenile DM, with different improvement thresholds. Sensitivity and specificity in DM/PM patient cohorts were 85% and 92%, 90% and 96%, and 92% and 98% for minimal, moderate, and major improvement, respectively. Definitions were validated in the clinical trial analysis for differentiating the physician rating of improvement (P < 0.001).ConclusionThe response criteria for adult DM/PM consisted of the conjoint analysis model based on absolute percent change in 6 core set measures, with thresholds for minimal, moderate, and major improvement.
Characterization of relative biological effectiveness for conventional radiation therapy: a comparison of clinical 6 MV X-rays and 137Cs
Howard, Michelle E. , Beltran, Chris , Herman, Michael , Sarkaria, Jann, Herman, Michael G., Sarkaria, Jann N. , Beltran, Chris J

Journal of Radiation Research | April 5, 2017 | Volume: 58 | Issue: 5 | Pages: 608-613

10.1093/jrr/rrx018 | PMID 28444207 Get It

ABSTRACT Various types of radiation are utilized in the treatment of cancer. Equal physical doses of different radiation types do not always result in the same amount of biological damage. In order to account for these differences, a scaling factor known as the relative biological effectiveness (RBE) can be used. 137Cesium (137Cs) has been used as a source of radiation in a significant body of radiation therapy research. However, high-energy X-rays, such as 6 MV X-rays, are currently used clinically to treat patients. To date, there is a gap in the literature regarding the RBE comparison of these two types of radiation. Therefore, the purpose of this study was to investigate the RBE of 137Cs relative to that of 6 MV X-rays. To determine the RBE, five cell lines were irradiated [Chinese hamster ovary (CHO); human lung adenocarcinoma (A549); human glioma (U251); human glioma (T98); and human osteosarcoma (U2OS)] by both types of radiation and assessed for cell survival using a clonogenic assay. Three of the five cell lines resulted in RBE values of ~1.00 to within 11% for all survival fractions, showing the physical and biological dose for these two types of radiation were equivalent. The other two cell lines gave RBE values differing from 1.00 by up to 36%. In conclusion, the results show the range in biological effect seen between cell lines, and therefore cell type must be considered when characterizing RBE.
Treatment planning for metals using an extended CT number scale
Mullins, John, Herman, Michael , Brinkmann, Debra H. , Antolak, John A. , Mullins, John P, Grams, Michael P.

Journal of Applied Clinical Medical Physics | February 28, 2017 | Volume: 17 | Issue: 6 | Pages: 179-188

10.1120/jacmp.v17i6.6153 | PMID 27929492 Get It

Metal implants which saturate the CT number scale may require dosimetrist and physicist involvement to manually contour and assign an appropriate value to the metal for accurate dose calculation. This study investigated dose calculation based directly on extended CT scale images for different metals and geometries. The aim was to evaluate extended CT accuracy as a suitable alternative to standard CT methods in the presence of high‐Z materials and artifacts, despite the reduced HU resolution of extended CT. Gafchromic film measurements were made for comparison to calculated doses. The method of direct dose calculation on extended CT scale was compared to our institution's standard method of manually contouring and assigning metal values on saturated CT images for each of the metal samples. Clinical patient plans with metal implants were investigated and DVHs were compared between standard CT and extended CT dose calculations. Dose calculations showed agreement within 2% between the two methods of metal characterization and the film measurement in the case of the strongest metal attenuator, cobalt‐chromium. In the clinical treatment plans, the greatest dose discrepancy between the two methods was 1.2%. This study suggests that direct dose calculation on an extended scale CT image in the presence of metal implants can produce accurate clinically viable treatment plans, thereby improving efficiency of clinical workflow and eliminating a potential source of human error by manual CT number assignment.PACS number(s): 87.55.dk