Citations

Mayo Clinic

Clear

112 citation(s) found for "Quaintance, Kerryl Greenwood".

Evaluation of the FilmArray Blood Culture ID Panel on Biofilms Dislodged from Explanted Arthroplasties for Prosthetic Joint Infection Diagnosis
Vasoo, Shawn , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Hanssen, Arlen D. , Osmon, Douglas R. , Berbari, Elie F. , Patel, Robin , Abdel, Matthew P. , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | May 28, 2015 | Volume: 53 | Issue: 8 | Pages: 2790-2792

10.1128/jcm.01333-15 | PMID 26019200 Get It

Antibiofilm Activity of Low-Amperage Continuous and Intermittent Direct Electrical Current
Schmidt-Malan, Suzannah M., Karau, Melissa J. , Cede, Julia , Greenwood‐Quaintance, Kerryl E. , Brinkman, Cassandra L., Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Antimicrobial Agents and Chemotherapy | May 27, 2015 | Volume: 59 | Issue: 8 | Pages: 4610-4615

10.1128/aac.00483-15 | PMID 26014944 Get It

ABSTRACT Bacterial biofilms are difficult to treat using available antimicrobial agents, so new antibiofilm strategies are needed. We previously showed that 20, 200, and 2,000 μA of electrical current reduced bacterial biofilms of Staphylococcus aureus , Staphylococcus epidermidis , and Pseudomonas aeruginosa . Here, we tested continuous direct current at lower amperages, intermittent direct current, and combinations of surface materials (Teflon or titanium) and electrode compositions (stainless steel, graphite, titanium, or platinum) against S. aureus , S. epidermidis , and P. aeruginosa biofilms. In addition, we tested 200 or 2,000 μA for 1 and 4 days against biofilms of 33 strains representing 13 species of microorganisms. The logarithmic reduction factor was used to measure treatment effects. Using continuous current delivery, the lowest active amperage was 2 μA for 1, 4, or 7 days against P. aeruginosa and 5 μA for 7 days against S. epidermidis and S. aureus biofilms. Delivery of 200 μA for 4 h a day over 4 days reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on Teflon or titanium discs. A reduction of P. aeruginosa , S. aureus , and S. epidermidis biofilms was measured for 23 of 24 combinations of surface materials and electrode compositions tested. Four days of direct current delivery reduced biofilms of 25 of 33 strains studied. In conclusion, low-amperage current or 4 h a day of intermittent current delivered using a variety of electrode compositions reduced P. aeruginosa , S. aureus , and S. epidermidis biofilms on a variety of surface materials. The electricidal effect was observed against a majority of bacterial species studied.
Superantigens produced by catheter-associated Staphylococcus aureus elicit systemic inflammatory disease in the absence of bacteremia
Greenwood‐Quaintance, Kerryl E. , Karau, Melissa J. , Tilahun, Ashenafi Y. , Khaleghi, Shahryar, Chowdhary, Vaidehi , David, Chella S., Patel, Robin , Rajagopalan, Govindarajan , Chung, Jin-Won, Tilahun, Ashenafi, Khaleghi, Shahryar Rostamkolaei, Chowdhary, Vaidehi R, Chung, Jin-Won , Patel, Robin

Journal of Leukocyte Biology | May 16, 2015 | Volume: 98 | Issue: 2 | Pages: 271-281

10.1189/jlb.4a1214-577rr | PMID 25979434 Get It

Abstract SAgs, produced by Staphylococcus aureus, play a major role in the pathogenesis of invasive staphylococcal diseases by inducing potent activation of the immune system. However, the role of SAgs, produced by S. aureus, associated with indwelling devices or tissues, are not known. Given the prevalence of device-associated infection with toxigenic S. aureus in clinical settings and the potency of SAgs, we hypothesized that continuous exposure to SAgs produced by catheter-associated S. aureus could have systemic consequences. To investigate these effects, we established a murine in vivo catheter colonization model. One centimeter long intravenous catheters were colonized with a clinical S. aureus isolate producing SAgs or isogenic S. aureus strains, capable or incapable of producing SAg. Catheters were subcutaneously implanted in age-matched HLA-DR3, B6, and AEo mice lacking MHC class II molecules and euthanized 7 d later. There was no evidence of systemic infection. However, in HLA-DR3 transgenic mice, which respond robustly to SSAgs, the SSAg-producing, but not the nonproducing strains, caused a transient increase in serum cytokine levels and a protracted expansion of splenic CD4+ T cells expressing SSAg-reactive TCR Vβ8. Lungs, livers, and kidneys from these mice showed infiltration with CD4+ and CD11b+ cells. These findings were absent in B6 and AEo mice, which are known to respond poorly to SSAgs. Overall, our novel findings suggest that systemic immune activation elicited by SAgs, produced by S. aureus colonizing foreign bodies, could have clinical consequences in humans.
Clinical Characteristics and Outcomes of Prosthetic Joint Infection Caused by Small Colony Variant Staphylococci
Tande, Aaron J. , Osmon, Douglas R. , Greenwood‐Quaintance, Kerryl E. , Mabry, Tad M. , Hanssen, Arlen D. , Patel, Robin , Tande, Aaron , Patel, Robin

mBio | October 1, 2014 | Volume: 5 | Issue: 5 | Pages: No page available

10.1128/mbio.01910-14 | PMID 25271290 Get It

ABSTRACT Small colony variants (SCVs) are naturally occurring subpopulations of bacteria. The clinical characteristics and treatment outcomes of patients with prosthetic joint infection (PJI) caused by staphylococcal SCVs are unknown. This study was a retrospective series of 113 patients with staphylococcal PJI, with prospective testing of archived sonicate fluid samples. SCVs were defined using two-investigator review. Treatment failure was defined as (i) subsequent revision surgery for any reason, (ii) PJI after the index surgery, (iii) prosthesis nonreimplantation due to ongoing infection, or (iv) amputation of the affected limb. There were 38 subjects (34%) with SCVs and 75 (66%) with only normal-phenotype (NP) bacteria. Subjects with SCVs were more likely to have been on chronic antimicrobials prior to surgery ( P = 0.048), have had prior surgery for PJI ( P = 0.03), have had a longer duration of symptoms ( P = 0.0003), and have had a longer time since joint implantation ( P = 0.007), compared to those with only NP bacteria. Over a median follow-up of 30.6 months, 9 subjects (24%) with SCVs and 23 (32%) with only NP bacteria experienced treatment failure ( P = 0.51). Subjects infected with Staphylococcus aureus were more likely to fail than were those infected with Staphylococcus epidermidis (hazard ratio [HR], 4.03; 95% confidence interval [CI], 1.80 to 9.04). While frequently identified in subjects with PJI and associated with several potential predisposing factors, SCVs were not associated with excess treatment failure compared to NP infections in this study, where they were primarily managed with two-stage arthroplasty exchange. IMPORTANCE Bacteria with the small colony variant (SCV) phenotype are described in small case series as causing persistent or relapsing infection, but there are insufficient data to suggest that they should be managed differently than infection with normal-phenotype bacteria. In an effort to investigate the clinical importance of this phenotype, we determined whether SCVs were present in biofilms dislodged from the surfaces of arthroplasties of patients with staphylococcal prosthetic joint infection and assessed the clinical outcomes associated with detection of SCVs. We found that prosthetic joint infection caused by SCV staphylococci was associated with a longer duration of symptoms and more prior treatment for infection but not with an increased rate of treatment failure, compared to infection caused by normal-phenotype staphylococci.
Prevention of Staphylococcus Epidermidis Biofilm Formation Using Electrical Current
Pozo, José Luís del , Rouse, Mark S., Euba, Gorane , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Del Pozo, Jose L, Patel, Robin

Journal of Applied Biomaterials & Functional Materials | September 5, 2014 | Volume: 12 | Issue: 2 | Pages: 81-83

10.5301/jabfm.5000208 | PMID 25097026 Get It

A technique for the prevention of staphylococcal adhesion by electrical current exposure was investigated. Teflon coupons were exposed to a continuous flow of 10 3 cfu/ml Staphylococcus epidermidis with or without 2000 microA DC electrical current delivered by electrodes on opposite sides of a coupon, touching neither each other nor the coupon. A mean 3.46 (SD, 0.20) and 5.70 (SD, 1.03) log 10 cfu/cm 2 were adhered to the non-electrical current exposed coupons after 4 h and 24 h, respectively. A mean 2.46 (SD, 0.31) and 1.47 (SD, 0.73) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by graphite electrodes. A mean 2.21 (SD, 0.14) and 0.55 (SD, 0.00) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by stainless steel electrodes. Electrical current may be useful in the prevention of staphylococcal adhesion to biomaterials.
Detection of Prosthetic Joint Infection by Use of PCR-Electrospray Ionization Mass Spectrometry Applied to Synovial Fluid
Melendez, Dante P. , Uhl, James R., Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Sampath, Rangarajan , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | April 10, 2014 | Volume: 52 | Issue: 6 | Pages: 2202-2205

10.1128/jcm.00570-14 | PMID 24719438 Get It

ABSTRACT PCR coupled with electrospray ionization mass spectrometry applied to synovial fluid specimens had an 81% sensitivity and a 95% specificity for the diagnosis of prosthetic joint infection.
Diagnosis of Prosthetic Joint Infection by Use of PCR-Electrospray Ionization Mass Spectrometry
Greenwood‐Quaintance, Kerryl E. , Uhl, James R., Hanssen, Arlen D. , Sampath, Rangarajan , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | November 28, 2013 | Volume: 52 | Issue: 2 | Pages: 642-649

10.1128/jcm.03217-13 | PMID 24478503 Get It

ABSTRACT We compared PCR-electrospray ionization mass spectrometry (PCR-ESI/MS) to culture using sonicate fluid from 431 subjects with explanted knee ( n = 270) or hip ( n = 161) prostheses. Of these, 152 and 279 subjects had prosthetic joint infection (PJI) and aseptic failure, respectively. The sensitivities for detecting PJI were 77.6% for PCR-ESI/MS and 69.7% for culture ( P = 0.0105). The specificities were 93.5 and 99.3%, respectively ( P = 0.0002).
Microbial Biofilms and Breast Tissue Expanders
Karau, Melissa J. , Greenwood‐Quaintance, Kerryl E. , Schmidt, Suzannah M., Tran, Nho V. , Convery, Phyllis A., Jacobson, Steven R., Bite, Uldis, Clay, Ricky P., Petty, Paul M., Johnson, C. H. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin

BioMed Research International | July 16, 2013 | Volume: 2013 | Issue: No issue available | Pages: 1-6

10.1155/2013/254940 | PMID 23956974 Get It

We previously developed and validated a vortexing-sonication technique for detection of biofilm bacteria on the surface of explanted prosthetic joints. Herein, we evaluated this technique for diagnosis of infected breast tissue expanders and used it to assess colonization of breast tissue expanders. From April 2008 to December 2011, we studied 328 breast tissue expanders at Mayo Clinic, Rochester, MN, USA. Of seven clinically infected breast tissue expanders, six (85.7%) had positive cultures, one of which grewPropionibacteriumspecies. Fifty-two of 321 breast tissue expanders (16.2%, 95% CI, 12.3–20.7%) without clinical evidence of infection also had positive cultures, 45 growingPropionibacteriumspecies and ten coagulase-negative staphylococci. While vortexing-sonication can detect clinically infected breast tissue expanders, 16 percent of breast tissue expanders appear to be asymptomatically colonized with normal skin flora, most commonly,Propionibacteriumspecies.
Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection
Cazanave, Charles , Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Karau, Melissa J. , Schmidt, Suzannah M., Urena, Eric O. Gomez, Mandrekar, Jayawant N. , Osmon, Douglas R. , Lough, Lindsay E., Pritt, Bobbi S. , Steckelberg, James M., Patel, Robin , Patel, Robin , Pritt, Bobbi S

Journal of Clinical Microbiology | May 9, 2013 | Volume: 51 | Issue: 7 | Pages: 2280-2287

10.1128/jcm.00335-13 | PMID 23658273 Get It

ABSTRACT We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee ( n = 272) or hip ( n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture ( P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure.
Prosthetic Joint Infection Diagnosis Using Broad-Range PCR of Biofilms Dislodged from Knee and Hip Arthroplasty Surfaces Using Sonication
Gomez, Eric, Cazanave, Charles , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Steckelberg, James M., Uhl, James R., Hanssen, Arlen D. , Karau, Melissa J. , Schmidt, Suzannah M., Osmon, Douglas R. , Berbari, Elie F. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | August 16, 2012 | Volume: 50 | Issue: 11 | Pages: 3501-3508

10.1128/jcm.00834-12 | PMID 22895042 Get It

ABSTRACT Periprosthetic tissue and/or synovial fluid PCR has been previously studied for prosthetic joint infection (PJI) diagnosis; however, few studies have assessed the utility of PCR on biofilms dislodged from the surface of explanted arthroplasties using vortexing and sonication (i.e., sonicate fluid PCR). We compared sonicate fluid 16S rRNA gene real-time PCR and sequencing to culture of synovial fluid, tissue, and sonicate fluid for the microbiologic diagnosis of PJI. PCR sequences generating mixed chromatograms were decatenated using RipSeq Mixed. We studied sonicate fluids from 135 and 231 subjects with PJI and aseptic failure, respectively. Synovial fluid, tissue, and sonicate fluid culture and sonicate fluid PCR had similar sensitivities (64.7, 70.4, 72.6, and 70.4%, respectively; P > 0.05) and specificities (96.9, 98.7, 98.3, and 97.8%, respectively; P > 0.05). Combining sonicate fluid culture and PCR, the sensitivity was higher (78.5%, P < 0.05) than those of individual tests, with similar specificity (97.0%). Thirteen subjects had positive sonicate fluid culture but negative PCR, and 11 had negative sonicate fluid culture but positive PCR (among which 7 had prior use of antimicrobials). Broad-range PCR and culture of sonicate fluid have equivalent performance for PJI diagnosis.