Back to Authors

Del Pozo, Jose L

Mayo Clinic

2 Infectious Diseases Research Laboratory, Mayo Clinic College of Medicine, Rochester, Minnesota - USA.

Citations 1

Prevention of Staphylococcus Epidermidis Biofilm Formation Using Electrical Current
Pozo, José Luís del , Rouse, Mark S., Euba, Gorane , Greenwood‐Quaintance, Kerryl E. , Mandrekar, Jayawant N. , Steckelberg, James M., Patel, Robin , Del Pozo, Jose L, Patel, Robin

Journal of Applied Biomaterials & Functional Materials | September 5, 2014 | Volume: 12 | Issue: 2 | Pages: 81-83

10.5301/jabfm.5000208 Get It

A technique for the prevention of staphylococcal adhesion by electrical current exposure was investigated. Teflon coupons were exposed to a continuous flow of 10 3 cfu/ml Staphylococcus epidermidis with or without 2000 microA DC electrical current delivered by electrodes on opposite sides of a coupon, touching neither each other nor the coupon. A mean 3.46 (SD, 0.20) and 5.70 (SD, 1.03) log 10 cfu/cm 2 were adhered to the non-electrical current exposed coupons after 4 h and 24 h, respectively. A mean 2.46 (SD, 0.31) and 1.47 (SD, 0.73) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by graphite electrodes. A mean 2.21 (SD, 0.14) and 0.55 (SD, 0.00) log 10 cfu/cm 2 were adhered after 4 h and 24 h with exposure to 2000 microA electrical current delivered by stainless steel electrodes. Electrical current may be useful in the prevention of staphylococcal adhesion to biomaterials.