Back to Authors

Cazanave, Charles

https://orcid.org/0000-0002-4613-3963

Mayo Clinic

Mayo Clinic

Citations 4

Rapid Molecular Microbiologic Diagnosis of Prosthetic Joint Infection
Cazanave, Charles , Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Karau, Melissa J. , Schmidt, Suzannah M., Urena, Eric O. Gomez, Mandrekar, Jayawant N. , Osmon, Douglas R. , Lough, Lindsay E., Pritt, Bobbi S. , Steckelberg, James M., Patel, Robin , Patel, Robin , Pritt, Bobbi S

Journal of Clinical Microbiology | May 9, 2013 | Volume: 51 | Issue: 7 | Pages: 2280-2287

10.1128/jcm.00335-13 Get It

ABSTRACT We previously showed that culture of samples obtained by prosthesis vortexing and sonication was more sensitive than tissue culture for prosthetic joint infection (PJI) diagnosis. Despite improved sensitivity, culture-negative cases remained; furthermore, culture has a long turnaround time. We designed a genus-/group-specific rapid PCR assay panel targeting PJI bacteria and applied it to samples obtained by vortexing and sonicating explanted hip and knee prostheses, and we compared the results to those with sonicate fluid and periprosthetic tissue culture obtained at revision or resection arthroplasty. We studied 434 subjects with knee ( n = 272) or hip ( n = 162) prostheses; using a standardized definition, 144 had PJI. Sensitivities of tissue culture, of sonicate fluid culture, and of PCR were 70.1, 72.9, and 77.1%, respectively. Specificities were 97.9, 98.3, and 97.9%, respectively. Sonicate fluid PCR was more sensitive than tissue culture ( P = 0.04). PCR of prosthesis sonication samples is more sensitive than tissue culture for the microbiologic diagnosis of prosthetic hip and knee infection and provides same-day PJI diagnosis with definition of microbiology. The high assay specificity suggests that typical PJI bacteria may not cause aseptic implant failure.
Prosthetic Joint Infection Diagnosis Using Broad-Range PCR of Biofilms Dislodged from Knee and Hip Arthroplasty Surfaces Using Sonication
Gomez, Eric, Cazanave, Charles , Cunningham, Scott A. , Greenwood‐Quaintance, Kerryl E. , Steckelberg, James M., Uhl, James R., Hanssen, Arlen D. , Karau, Melissa J. , Schmidt, Suzannah M., Osmon, Douglas R. , Berbari, Elie F. , Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | August 16, 2012 | Volume: 50 | Issue: 11 | Pages: 3501-3508

10.1128/jcm.00834-12 Get It

ABSTRACT Periprosthetic tissue and/or synovial fluid PCR has been previously studied for prosthetic joint infection (PJI) diagnosis; however, few studies have assessed the utility of PCR on biofilms dislodged from the surface of explanted arthroplasties using vortexing and sonication (i.e., sonicate fluid PCR). We compared sonicate fluid 16S rRNA gene real-time PCR and sequencing to culture of synovial fluid, tissue, and sonicate fluid for the microbiologic diagnosis of PJI. PCR sequences generating mixed chromatograms were decatenated using RipSeq Mixed. We studied sonicate fluids from 135 and 231 subjects with PJI and aseptic failure, respectively. Synovial fluid, tissue, and sonicate fluid culture and sonicate fluid PCR had similar sensitivities (64.7, 70.4, 72.6, and 70.4%, respectively; P > 0.05) and specificities (96.9, 98.7, 98.3, and 97.8%, respectively; P > 0.05). Combining sonicate fluid culture and PCR, the sensitivity was higher (78.5%, P < 0.05) than those of individual tests, with similar specificity (97.0%). Thirteen subjects had positive sonicate fluid culture but negative PCR, and 11 had negative sonicate fluid culture but positive PCR (among which 7 had prior use of antimicrobials). Broad-range PCR and culture of sonicate fluid have equivalent performance for PJI diagnosis.
Corynebacterium Prosthetic Joint Infection
Cazanave, Charles , Greenwood‐Quaintance, Kerryl E. , Hanssen, Arlen D. , Patel, Robin , Patel, Robin

Journal of Clinical Microbiology | February 15, 2012 | Volume: 50 | Issue: 5 | Pages: 1518-1523

10.1128/jcm.06439-11 Get It

ABSTRACT Identification of Corynebacterium species may be challenging. Corynebacterium species are occasional causes of prosthetic joint infection (PJI), but few data are available on the subject. Based on the literature, C. amycolatum , C. aurimucosum , C. jeikeium , and C. striatum are the most common Corynebacterium species that cause PJI. We designed a rapid PCR assay to detect the most common human Corynebacterium species, with a specific focus on PJI. A polyphosphate kinase gene identified using whole-genome sequence was targeted. The assay differentiates the antibiotic-resistant species C. jeikeium and C. urealyticum from other species in a single assay. The assay was applied to a collection of human Corynebacterium isolates from multiple clinical sources, and clinically relevant species were detected. The assay was then tested on Corynebacterium isolates specifically associated with PJI; all were detected. We also describe the first case of C. simulans PJI.
Identification of Non-diphtheriae Corynebacterium by Use of Matrix-Assisted Laser Desorption Ionization–Time of Flight Mass Spectrometry
Alatoom, Adnan, Cazanave, Charles , Cunningham, Scott A. , Ihde, Sherry M., Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | November 11, 2011 | Volume: 50 | Issue: 1 | Pages: 160-163

10.1128/jcm.05889-11 Get It

ABSTRACTWe evaluated the Bruker Biotyper matrix-assisted laser desorption ionization–time of flight (MALDI-TOF) mass spectrometry for identification of 92 clinical isolates ofCorynebacteriumspecies in comparison to identification usingrpoBor 16S rRNA gene sequencing. Eighty isolates (87%) yielded a score of ≥1.700, and all of these were correctly identified to the species level with the exception ofCorynebacterium aurimucosumbeing misidentified as the closely relatedCorynebacterium minutissimum.