Citations

Mayo Clinic

Clear

162 citation(s) found for "Ehman, R L".

Quantitative assessment of lung stiffness in patients with interstitial lung disease using MR elastography
Marinelli, John P. , Levin, David L. , Hubmayr, Rolf D., McGee, Kiaran P. , Vassallo, Robert , Carter, Rickey E. , Ehman, Richard L.

Journal of Magnetic Resonance Imaging | July 13, 2017 | Volume: 46 | Issue: 2 | Pages: No page available

10.1002/jmri.25805 Get It

PurposeTo investigate the use of magnetic resonance elastography (MRE) in the quantitative assessment of pulmonary fibrosis by comparing quantitative shear stiffness measurements of lung parenchyma in patients diagnosed with fibrotic interstitial lung disease (ILD) and healthy controls.Materials and MethodsA 1.5T spin‐echo, echo planar imaging MRE (SE‐EPI MRE) pulse sequence was utilized to assess absolute lung shear stiffness in 15 patients with diagnosed ILD and in 11 healthy controls. Data were collected at residual volume (RV) and total lung capacity (TLC). Spirometry data were obtained immediately prior to scanning. To test for statistical significance between RV and TLC shear stiffness estimates a two‐sample t‐test was performed. To assess variability within individual subject shear stiffness estimates, the intraclass correlation coefficient (ICC) and Krippendorff's alpha were calculated.ResultsPatients with ILD exhibited an average (±1 standard deviation) shear stiffness of 2.74 (±0.896) kPa at TLC and 1.32 (±0.300) kPa at RV. The corresponding values for healthy individuals were 1.33 (±0.195) kPa and 0.849 (±0.250) kPa, respectively. The difference in shear stiffness between RV and TLC was statistically significant (P < 0.001). At TLC, the ICC and alpha values were 0.909 and 0.887, respectively. At RV, the ICC and alpha values were 0.852 and 0.862, respectively.ConclusionIn subjects with known fibrotic interstitial lung disease, parenchymal shear stiffness is increased when compared to normal controls at both RV and TLC, with TLC demonstrating the most significant difference. MRE‐derived parenchymal shear stiffness is a promising new noninvasive imaging‐based biomarker of interstitial lung disease.Level of Evidence:1J. MAGN. RESON. IMAGING 2017;46:1–1
MR Elastography Demonstrates Unique Regional Brain Stiffness Patterns in Dementias
ElSheikh, Mona M., Arani, Arvin , Perry, Avital , Meyer, Fredric B. , Savica, Rodolfo , ElSheikh, Mona, Boeve, Bradley F. , Ehman, Richard L. , Huston, John , Arani, Arvin

American Journal of Roentgenology | June 1, 2017 | Volume: 209 | Issue: 2 | Pages: 403-408

10.2214/ajr.16.17455 | PMID 28570101 Get It

Automated low‐contrast pattern recognition algorithm for magnetic resonance image quality assessment
Ehman, Morgan O., Bao, Zhonghao , Stiving, Scott O., Kasam, Mallikarjunarao , Lanners, Dianna , Peterson, Teresa, Jonsgaard, Renee , Carter, Rickey E. , McGee, Kiaran P. , Kasam, Mallik, Carter, Rickey, Carter, Rickey E

Medical Physics | May 25, 2017 | Volume: 44 | Issue: 8 | Pages: 4009-4024

10.1002/mp.12370 | PMID 28543961 Get It

PurposeLow contrast (LC) detectability is a common test criterion for diagnostic radiologic quality control (QC) programs. Automation of this test is desirable in order to reduce human variability and to speed up analysis. However, automation is challenging due to the complexity of the human visual perception system and the ability to create algorithms that mimic this response. This paper describes the development and testing of an automated LC detection algorithm for use in the analysis of magnetic resonance (MR) images of the American College of Radiology (ACR) QC phantom.MethodsThe detection algorithm includes fuzzy logic decision processes and various edge detection methods to quantify LC detectability. Algorithm performance was first evaluated using a single LC phantom MR image with the addition of incremental zero mean Gaussian noise resulting in a total of 200 images. A c‐statistic was calculated to determine the role of CNR to indicate when the algorithm would detect ten spokes. To evaluate inter‐rater agreement between experienced observers and the algorithm, a blinded observer study was performed on 196 LC phantom images acquired from nine clinical MR scanners. The nine scanners included two MR manufacturers and two field strengths (1.5 T, 3.0 T). Inter‐rater and algorithm‐rater agreement was quantified using Krippendorff's alpha.ResultsFor the Gaussian noise added data, CNR ranged from 0.519 to 11.7 with CNR being considered an excellent discriminator of algorithm performance (c‐statistic = 0.9777). Reviewer scoring of the clinical phantom data resulted in an inter‐rater agreement of 0.673 with the agreement between observers and algorithm equal to 0.652, both of which indicate significant agreement.ConclusionsThis study demonstrates that the detection of LC test patterns for MR imaging QC programs can be successfully developed and that their response can model the human visual detection system of expert MR QC readers.
Repeatability of MR Elastography of Liver: A Meta-Analysis
Serai, Suraj D. , Obuchowski, Nancy A. , Venkatesh, Sudhakar K. , Miller, Frank H. , Ashton, Edward, Cole, Patricia E., Sirlin, Claude B. , Ehman, Richard L. , Venkatesh, Sudhakar K , Serai, Suraj D , Miller, Frank H

Radiology | May 22, 2017 | Volume: 285 | Issue: 1 | Pages: 92-100

10.1148/radiol.2017161398 | PMID 28530847 Get It

Magnetic resonance elastography measured shear stiffness as a biomarker of fibrosis in pediatric nonalcoholic fatty liver disease
Schwimmer, Jeffrey B. , Behling, Cynthia , Angeles, Jorge E., Paiz, Melissa, Durelle, Janis, Africa, Jonathan A. , Newton, Kimberly P. , Brunt, Elizabeth M. , Lavine, Joel E. , Abrams, Stephanie H., Masand, Prakash, Krishnamurthy, Rajesh , Wong, Kelvin, Yin, Meng , Glaser, Kevin J. , Wolfson, Tanya, Gamst, Anthony, Hooker, Jonathan , Haufe, William, Schlein, Alexandra , Hamilton, Gavin , Middleton, Michael S. , Dzyubak, Bogdan , Ehman, Richard L. , Hamilton, Gavin , Sirlin, Claude B. , Schwimmer, Jeffrey B , Yin, Meng

Hepatology | May 11, 2017 | Volume: 66 | Issue: 5 | Pages: 1474-1485

10.1002/hep.29241 | PMID 28493388 Get It

Magnetic resonance elastography (MRE) is a promising technique for noninvasive assessment of fibrosis, a major determinant of outcome in nonalcoholic fatty liver disease (NAFLD). However, data in children are limited. The purpose of this study was to determine the accuracy of MRE for the detection of fibrosis and advanced fibrosis in children with NAFLD and to assess agreement between manual and novel automated reading methods. We performed a prospective, multicenter study of two‐dimensional (2D) MRE in children with NAFLD. MR elastograms were analyzed manually at two reading centers, and using a new automated technique. Analysis using each approach was done independently. Correlations were determined between MRE analysis methods and fibrosis stage. Thresholds for classifying the presence of fibrosis and of advanced fibrosis were computed and cross‐validated. In 90 children with a mean age of 13.1 ± 2.4 years, median hepatic stiffness was 2.35 kPa. Stiffness values derived by each reading center were strongly correlated with each other (r = 0.83). All three analyses were significantly correlated with fibrosis stage (center 1, ρ = 0.53; center 2, ρ = 0.55; and automated analysis, ρ = 0.52; P < 0.001). Overall cross‐validated accuracy for detecting any fibrosis was 72.2% for all methods (95% confidence interval [CI], 61.8%‐81.1%). Overall cross‐validated accuracy for assessing advanced fibrosis was 88.9% (95% CI, 80.5%‐94.5%) for center 1, 90.0% (95% CI, 81.9%‐95.3%) for center 2, and 86.7% (95% CI, 77.9%‐92.9%) for automated analysis. Conclusion : 2D MRE can estimate hepatic stiffness in children with NAFLD. Further refinement and validation of automated analysis techniques will be an important step in standardizing MRE. How to best integrate MRE into clinical protocols for the assessment of NAFLD in children will require prospective evaluation. (H epatology 2017;66:1474–1485)
Acute pressure changes in the brain are correlated with MR elastography stiffness measurements: initial feasibility in an in vivo large animal model
Arani, Arvin , Min, Hoon‐Ki , Fattahi, Nikoo , Wetjen, Nicholas M. , Trzasko, Joshua D. , Jack, Clifford R. , Lee, Kendall H. , Min, Hoon-Ki Paul , Manduca, Armando , Ehman, Richard L. , Huston, John , Jack, Clifford R , Arani, Arvin

Magnetic Resonance in Medicine | May 10, 2017 | Volume: 79 | Issue: 2 | Pages: 1043-1051

10.1002/mrm.26738 | PMID 28488326 Get It

PurposeThe homeostasis of intracranial pressure (ICP) is of paramount importance for maintaining normal brain function. A noninvasive technique capable of making direct measurements of ICP currently does not exist. MR elastography (MRE) is capable of noninvasively measuring brain tissue stiffness in vivo, and may act as a surrogate to measure ICP. The objective of this study was to investigate the impact of changing ICP on brain stiffness using MRE in a swine model.MethodsBaseline MRE measurements were obtained, and then catheters were surgically placed into the left and right lateral ventricles of three animals. ICP was systematically increased over the range of 0 to 55 millimeters mercury (mmHg), and stiffness measurements were made using brain MRE at vibration frequencies of 60 hertz (Hz), 90 Hz, 120 Hz, and 150 Hz.ResultsA significant linear correlation between stiffness and ICP in the cross‐subject comparison was observed for all tested vibrational frequencies (P ≤ 0.01). The 120 Hz (0.030 ± 0.004 kilopascal (kPa)/mmHg, P < 0.0001) and 150 Hz (0.031 ± 0.008 kPa/mmHg, P = 0.01) vibrational frequencies had nearly identical slopes, which were approximately two‐ to three‐fold higher than the 90 Hz (0.017 ± 0.002 kPa/mmHg, P < 0.0001) and 60 Hz (0.009 ± 0.002 kPa/mmHg, P = 0.001) slopes, respectively.ConclusionIn this study, MRE demonstrated the potential for noninvasive measurement of changes in ICP. Magn Reson Med 79:1043–1051, 2018. © 2017 The Authors Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. on behalf of International Society for Magnetic Resonance in Medicine. This is an open access article under the terms of the Creative Commons Attribution‐NonCommercial‐NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non‐commercial and no modifications or adaptations are made.
How Preferences for Continuity and Access Differ Between Multimorbidity and Healthy Patients in a Team Care Setting
Ehman, Katherine M., Deyo-Svendsen, Mark , Merten, Zachary, Kramlinger, Anne Marie, Garrison, Gregory M.

Journal of Primary Care & Community Health | April 22, 2017 | Volume: 8 | Issue: 4 | Pages: 319-323

10.1177/2150131917704556 | PMID 28434390 Get It

Introduction: Team-based care has become an essential part of modern medical practice. Patient-centered medical homes often struggle to balance the dual competing goals of acute access and continuity of care. Multimorbidity patients may value continuity more than healthy patients, and thus may prefer to wait to see their primary care physician (PCP). Methods: A total of 1700 randomly selected healthy adults and multimorbidity patients were asked to rate satisfaction with care and presented with 4 acute and 4 chronic scenarios to choose an access and continuity preference in an anonymous mailed survey. Results: In all, 770 responses were obtained. All respondents preferred to be seen 2.5 days sooner for acute appointments. Multimorbidity patients preferred to wait 0.28 days longer for acute issues to see their PCP. Patients who were not satisfied with their care team preferred to wait 0.75 days to see their PCP. Those not satisfied with their PCP choose to be seen 0.38 days sooner by their care team or any physician. Conclusions: All patients prefer continuity of care with their PCP for chronic disease management and value quick access to care for acute problems. For acute visits, multimorbidity patients prefer to wait longer to see their PCP than healthy adults. Satisfaction also plays an important role in patients’ willingness to wait for an appointment with their PCP.
Regional assessment of in vivo myocardial stiffness using 3D magnetic resonance elastography in a porcine model of myocardial infarction
Arunachalam, Shivaram P. , Arani, Arvin , Baffour, Francis , Rysavý, J, Rossman, Phillip J. , Glaser, Kevin J. , Lake, David S. , Trzasko, Joshua D. , McGee, Kiaran P. , Araoz, Philip A. , Rysavy, Joseph A, Manduca, Armando , Ehman, Richard L. , Arunachalam, S P , Arani, Arvin , Baffour, Francis I

Magnetic Resonance in Medicine | April 6, 2017 | Volume: 79 | Issue: 1 | Pages: 361-369

10.1002/mrm.26695 | PMID 28382658 Get It

Purpose The stiffness of a myocardial infarct affects the left ventricular pump function and remodeling. Magnetic resonance elastography (MRE) is a noninvasive imaging technique for measuring soft‐tissue stiffness in vivo. The purpose of this study was to investigate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE in a porcine model of myocardial infarction, and compare the results with ex vivo uniaxial tensile testing. Methods Myocardial infarct was induced in a porcine model by embolizing the left circumflex artery. Fourteen days postinfarction, MRE imaging was performed in diastole using an echocardiogram‐gated spin‐echo echo‐planar‐imaging sequence with 140‐Hz vibrations and 3D MRE processing. The MRE stiffness and tensile modulus from uniaxial testing were compared between the remote and infarcted myocardium. Results Myocardial infarcts showed increased in vivo MRE stiffness compared with remote myocardium (4.6 ± 0.7 kPa versus 3.0 ± 0.6 kPa, P = 0.02) within the same pig. Ex vivo uniaxial mechanical testing confirmed the in vivo MRE results, showing that myocardial infarcts were stiffer than remote myocardium (650 ± 80 kPa versus 110 ± 20 kPa, P = 0.01). Conclusions These results demonstrate the feasibility of assessing in vivo regional myocardial stiffness with high‐frequency 3D cardiac MRE. Magn Reson Med 79:361–369, 2018. © 2017 International Society for Magnetic Resonance in Medicine.
PET/MRI: Where might it replace PET/CT?
Ehman, Eric C. , Johnson, Geoffrey B. , Leynes, Andrew P. , Johnson, Geoffrey B. , Villanueva-Meyer, Javier E. , Cha, Soonmee , Larson, Peder E. Z. , Hope, Thomas A. , Johnson, Geoffrey B , Johnson, Geoffrey B

Journal of Magnetic Resonance Imaging | March 31, 2017 | Volume: 46 | Issue: 5 | Pages: 1247-1262

10.1002/jmri.25711 | PMID 28370695 Get It

Simultaneous positron emission tomography and MRI (PET/MRI) is a technology that combines the anatomic and quantitative strengths of MR imaging with physiologic information obtained from PET. PET and computed tomography (PET/CT) performed in a single scanning session is an established technology already in widespread and accepted use worldwide. Given the higher cost and complexity of operating and interpreting the studies obtained on a PET/MRI system, there has been question as to which patients would benefit most from imaging with PET/MRI versus PET/CT. In this article, we compare PET/MRI with PET/CT, detail the applications for which PET/MRI has shown promise and discuss impediments to future adoption. It is our hope that future work will prove the benefit of PET/MRI to specific groups of patients, initially those in which PET/CT and MRI are already performed, leveraging simultaneity and allowing for greater degrees of multiparametric evaluation.Level of Evidence: 5Technical Efficacy: Stage 5J. Magn. Reson. Imaging 2017;46:1247–1262.
Automated liver elasticity calculation for 3D MRE
Dzyubak, Bogdan , Glaser, Kevin J. , Manduca, Armando , Ehman, Richard L. , Dzyubak, Bogdan

SPIE Proceedings | March 3, 2017 | Volume: 10134 | Issue: No issue available | Pages: 101340Y

10.1117/12.2254476 | PMID 29033488 Get It