Citations

Mayo Clinic

Showing 10 of 108162 citations.

Genetic Counseling for Mental Health Disorders
Pestka, Elizabeth L.

Journal of the American Psychiatric Nurses Association | April 3, 2006 | Volume: 11 | Issue: 6 | Pages: 338-343

10.1177/1078390305284454 Get It

The sequenced map of the DNA base pairs in the human genome is making it easier to understand the biological pathways involved in mental illnesses and to develop better methods of diagnosis, treatment, and ultimately prevention. This article describes the genetic counseling process for psychiatric disorders, including the use of a family pedigree and predicting genetic inheritance risks based on family history. It also addresses client education issues and the health professionals involved in genetics counseling services. Ethical, legal, and social implications of psychiatric genomics are discussed.
A Novel Endocytic Mechanism of Epidermal Growth Factor Receptor Sequestration and Internalization
Orth, James D. , Krueger, Eugene W. , Weller, Shaun G. , McNiven, Mark A.

Cancer Research | April 3, 2006 | Volume: 66 | Issue: 7 | Pages: 3603-3610

10.1158/0008-5472.can-05-2916 | PMID 16585185 Get It

Abstract Cells form transient, circular dorsal ruffles or “waves” in response to stimulation of receptor tyrosine kinases, including epidermal growth factor receptor (EGFR) or platelet-derived growth factor receptor. These dynamic structures progress inward on the dorsal surface and disappear, occurring concomitantly with a marked reorganization of F-actin. The cellular function of these structures is largely unknown. Here we show that EGF-induced waves selectively sequester and internalize ∼50% of ligand-bound EGFR from the cell surface. This process requires receptor phosphorylation, active phosphatidylinositol 3-kinase, and dynamin 2, although clathrin-coated pits or caveolae are not required. Epithelial and fibroblast cells stimulated with EGF sequestered EGFR rapidly into waves that subsequently generated numerous receptor-positive tubular-vesicular structures. Electron microscopy confirmed that waves formed along the dorsal membrane surface and extended numerous tubules into the cytoplasm. These findings characterize a structure that selectively sequesters large numbers of activated EGFR for their subsequent internalization, independent of traditional endocytic mechanisms such as clathrin pits or caveolae. (Cancer Res 2006; 66(7): 3603-10)
Surgical Anatomy Of Dural Defects In Spontaneous Spinal Cerebrospinal Fluid Leaks
Cohen‐Gadol, Aaron , Mokri, Bahram, Piepgras, David G., Meyer, Fredric B. , Atkinson, John L. D.

Operative Neurosurgery | April 3, 2006 | Volume: 58 | Issue: suppl_4 | Pages: ONS-238-ONS-245

10.1227/01.neu.0000204712.16099.fb | PMID 16582646 Get It

Abstract Objective: Spontaneous intracranial hypotension is typically caused by a spontaneous spinal cerebrospinal fluid (CSF) leak. The configuration of the related dural defects can be complex. We describe our experience with the surgical anatomy of these defects. Methods: Thirteen consecutive patients with spontaneous spinal CSF leaks who underwent surgical exploration at Mayo Clinic between 1994 and 2003 were studied. All patients' records, imaging studies, detailed intraoperative findings, and outcomes were reviewed. Results: There were four men and nine women with an average age of 40 years (range, 12–62 yr). Preoperative imaging studies revealed a single site of CSF leak in eight patients, two sites in three patients, and multiple sites in two patients. Intraoperatively, the exact site of leakage could not be found in four patients. Among the other nine patients, primary closure of a meningeal diverticulum was achieved in one patient. Significant regional attenuation of the dura prevented primary repair of the leak site in eight patients. Muscle, fibrin glue, and Gelfoam (Upjohn Co., Kalamazoo, MI) soaked in patient's own blood were commonly used to pack the epidural space in an attempt to seal the site of the leak. Ligation of two nonappendicular nerve roots allowed closure of the leak in one of these patients. Postoperatively, resolution of symptoms occurred in eight patients, significant improvement was noted in three patients, and only transient resolution in two. The mean duration of follow-up was 20.5 months. Conclusion: Surgery for closure of spontaneous spinal CSF leaks may not be straightforward. Even when extradural CSF leakage is discovered preoperatively by imaging studies, it may not always be possible to identify the exact site of the leakage intraoperatively. Furthermore, the anatomy of the dural defects may be complex and not amenable to primary closure. In such cases, the use of adjuvant techniques during surgical exploration may be effective.
Cephalalgic Alopecia Areata
Cutrer, F. Michael , Pittelkow, MR

Cephalalgia | April 3, 2006 | Volume: 26 | Issue: 6 | Pages: 747-751

10.1111/j.1468-2982.2006.01098.x | PMID 16686916 Get It

Management of a Large Intraoperative Type IIIb Endoleak in a Bifurcated Endograft
Hakaim, Albert G., Oldenburg, W. Andrew, Klocker, Josef , McKinney, J. Mark , Paz‐Fumagalli, Ricardo , Biebl, Matthias

Vascular and Endovascular Surgery | March 31, 2006 | Volume: 39 | Issue: 3 | Pages: 267-271

10.1177/153857440503900308 | PMID 15920656 Get It

The purpose of this paper is to describe the intraoperative management of a type IIIb endoleak after deployment of a bifurcated endograft in a patient with narrow iliac access vessels. A 62-year-old man underwent elective endovascular repair (EVAR) of a 53 mm abdominal aortic aneurysm. After device deployment, a large IIIb endoleak, arising from the main body of the device, was visualized. Narrow iliac vessels precluded deployment of a second bifurcated graft, and the endoleak was successfully excluded with an aortomonoiliac device, followed by contralateral iliac occlusion and subsequent creation of a femorofemoral bypass. At 1-year follow-up, the aneurysm remains excluded and is decreasing in size. Type III endoleaks are a known complication of EVAR, requiring immediate treatment through their association with aneurysm enlargement and rupture. If an additional bifurcated graft cannot be used, aortomonoiliac conversion represents a feasible endovascular alternative treatment for type III endoleaks, other than conversion to open surgical repair. Therefore, aortomonoiliac converters with appropriate occluder devices should be readily available during deployment of bifurcated devices.
Most Patients with Abdominal Aortic Aneurysm Are Not Suitable for Endovascular Repair Using Currently Approved Bifurcated Stent-Grafts
Elkouri, Stéphane , Martelli, Eugenio , Gloviczki, Péter , McKusick, Michael A., Panneton, Jean M. , Andrews, James C. , Noel, Audra A., Bower, Thomas C., Sullivan, Timothy M. , Rowland, Charles M. , Cherry, Kenneth J., Hoskin, Tanya L. , Gloviczki, Péter

Vascular and Endovascular Surgery | March 31, 2006 | Volume: 38 | Issue: 5 | Pages: 401-412

10.1177/153857440403800502 | PMID 15490036 Get It

Strict morphologic criteria must be used for patient selection to achieve durable success with endovascular aortic aneurysm repair (EVAR). The goal of this study was to assess morphologic suitability (MS) of abdominal aortic aneurysms (AAAs) for 2 currently approved bifurcated stent grafts and identify reasons for exclusion from EVAR. The authors reviewed the electronic charts of 1,795 consecutive patients who were diagnosed as having AAA between January 1999 and July 2001 at their institution. Three hundred and twenty patients had an AAA with a diameter of =5.0 cm, measured on computed tomography (CT). The records of 301 patients, 254 men, 47 women, with a mean age of 74 years were available for review, and these patients constituted the study cohort. Criteria used for MS included a proximal neck length =15 mm; neck diameter between 18 and 26 mm; neck angulation =60°; common or external iliac artery (CIA or EIA) diameters of 7–16 mm and 8–13 mm, respectively, for AneuRx (Medtronic Ave, Santa Rosa, CA) and Ancure (Guidant Cardiac and Vascular Division, Menlo Park, CA) bifurcated grafts. AAAs were suitable for AneuRx device in 14% of patients (43 of 301; 95% CI = 11–19%) and for Ancure in 5% (16 of 301; 95% CI = 3.1–9%). The main reason for exclusion was an inadequate proximal aortic neck (73%). The neck was too short in 49.5%, too wide in 64% and badly angulated in 12% of the patients. Iliac artery morphology precluded EVAR with AneuRx and Ancure devices in 52% and 80%. Both CIAs were too wide for EVAR in 43% and 77%, respectively. When iliac artery diameter =20 mm was accepted, iliac suitability for AneuRx increased from 49% to 70% and overall suitability increased from 14% to 20%. When more permissive criteria were used for MS (neck length =10 mm, neck diameter =30 mm, CIA =20), 39% of patients became candidates for EVAR. More than three fourths of the patients with an AAA =5.0 cm in size, seen in a tertiary referral center, are morphologically not suitable for EVAR using 2 currently approved bifurcated endografts. The main reasons for exclusion are a short or wide proximal aortic neck. Considerable changes in size of the devices and in proximal attachment techniques have to occur before most AAAs will be suitable for EVAR.
Renal Artery Stenosis and a Functioning Hilar Paraganglioma: A Rare Cause of Renovascular Hypertension
Chandra, V., Thompson, Geoffrey B. , Bower, Thomas C., Taler, Sandra J.

Vascular and Endovascular Surgery | March 31, 2006 | Volume: 38 | Issue: 4 | Pages: 385-390

10.1177/153857440403800413 | PMID 15306959 Get It

Surgically correctable causes of hypertension are uncommon. Simultaneous occurrence of 2 such causes in the same individual is extremely rare. The authors describe a 25-year-old woman with congenital erythrocytosis, renal artery stenosis, and a paraganglioma. The possible mechanisms of renal artery stenosis in the presence of a catecholamine-secreting tumor are discussed.
New Discoveries in Anatomy and New Terminology of Leg Veins: Clinical Implications
Mózes, Gèza, Gloviczki, Péter , Gloviczki, Péter

Vascular and Endovascular Surgery | March 31, 2006 | Volume: 38 | Issue: 4 | Pages: 367-374

10.1177/153857440403800410 | PMID 15306956 Get It

Advances in diagnosis and in endovascular and surgical treatments of both acute and chronic venous diseases have focused attention on several, previously clinically less important, details of venous anatomy. The time has come to standardize venous nomenclature so that general practitioners and specialists in the United States and abroad speak the same language. There is a need to adopt a universal terminology for the saphenous veins, to avoid the myriad of eponyms of perforators and, most importantly, to omit once and for all, the term “superficial” femoral vein when talking about a deep vein of the thigh. New anatomic names, such as the saphenous fascia and saphenous subcompartment, have to gain better recognition. To achieve the desired consensus on venous nomenclature, an international meeting was held in Rome, Italy, in 2001, under the auspices of the International Union of Phlebology. In this review on venous anatomy, we describe the most important previously published clinical recommendations from this conference, and suggest modifications based on their clinical experience using the new terminology.
Stapled Aortic Anastomoses: A Minimally Invasive, Feasible Alternative to Videoscopic Aortic Suturing?
Elkouri, Stéphane , Noel, Audra A., Gloviczki, Péter , Karnicki, Krzysztof, Phelps, Raymond R., Bernard, Geraldine K., Deschamps, Claude, Rowland, C, Douglas, Christopher J. , Prieto, Mikel , Gloviczki, Péter

Vascular and Endovascular Surgery | March 31, 2006 | Volume: 38 | Issue: 4 | Pages: 321-330

10.1177/153857440403800403 | PMID 15306949 Get It

Widespread applications of totally laparoscopic aortic reconstructions have been limited by the long cross-clamp time required to suture the aortic anastomosis despite improvement in instrumentation. The authors' hypothesis was that a “one-step anastomosis concept” using an intraluminal stapler would allow shorter cross-clamp time but similar patency and imperviousness as videoscopic suturing techniques. An intraluminal stapler (Endopath-ILS, Ethicon) with a modified anvil was used to perform videoscopic-assisted thoracic aorta-to-iliac artery bypass with a 21 mm by 8 mm polytetrafluoroethylene (PTFE) graft in 22 sheep through a minimally invasive approach using a 5 cm thoracotomy. The graft-to-iliac artery anastomoses were hand sutured through a flank incision. Twelve sheep were used to establish the technique and 10 subsequent animals constituted the study group. Aortic cross-clamp time, imperviousness, and need for additional sutures were recorded and compared to previously reported data using videoscopic suturing in pigs. Patency was assessed by comparing lower limb arterial pressures. Macroscopic and microscopic examinations of the anastomoses were performed at different time-points within the first 3 months. Videoscopic-assisted stapled anastomoses were also performed on atherosclerotic aortas of 3 human cadavers. Stapled anastomoses between the thoracic aorta and PTFE graft were completed in 8 of 10 animals. Two animals were euthanized after stapler failure and anastomotic bleeding. Sutures to strengthen the anastomosis had to be used in 4 cases. Mean aortic cross-clamp time in 8 successful cases was 4.3 ±2.9 minutes (range 2–11 minutes) and was significantly shorter than clamp time of videoscopic suturing technique (48.7 ±9.4 minutes, p<0.0001). Imperviousness was good or excellent in 4 animals and fair in 4 animals. All anastomoses were patent at the end of the procedure. Examination of the anastomosis of the 2 failed interventions showed medial aortic tear surrounding the anastomosis in 1 case and misfired staples in the other. No graft occlusion was noted during follow-up ranging from 0 to 12 weeks. At the time of harvest, no bleeding was noted after epinephrine and volume infusion to increase mean arterial pressure to 200 mm Hg for 15 minutes. Macroscopic examination of the anastomoses revealed adequate healing with circumferential stapling of the prosthesis to the aortic wall and no stenosis or thrombus except in 1 false aneurysm (1/7, 14%). Surface electron microscopy showed cells coverage of the anastomosis surface. When applied on human cadaver thoracic and abdominal aorta with atherosclerotic changes, clamping times of less than 5 minutes were achieved. However, imperviousness tested with saline was poor. An automatic stapling device allows performance of a graft-to-aorta anastomosis through a minimally invasive approach with shorter clamping time than a videoscopic suturing technique. However, the current technique of aortic stapling is unreliable and further improvements are needed.
Hand-Assisted Laparoscopic Aorto-Aortic Bypass: Initial Experience in a Porcine Model
Elkouri, Stéphane , Gloviczki, Péter , Prieto, Mikel , Park, Woosup M., Noel, Audra A., Gloviczki, Péter

Vascular and Endovascular Surgery | March 31, 2006 | Volume: 38 | Issue: 3 | Pages: 241-248

10.1177/153857440403800308 | PMID 15181506 Get It

Videoscopic surgical techniques have been developed to reduce morbidity of open aortic reconstructions. The advantage of hand-assisted laparoscopic surgery (HALS) technique is the introduction of the surgeon's hand into the peritoneal cavity. The aims of this study were to assess the feasibility and to examine the learning curve, limitations, and pitfalls of the HALS technique to perform aortic reconstruction in a porcine model for training purposes. HALS aorto-aortic 8 mm polytetrafluoroethylene (PTFE) interposition grafts were placed in 12 pigs. Proficiency was judged by measuring operative time points, satisfactory completion of the operation, and the need to convert to open procedure. The strength of the relationship between order number in which a procedure was performed and the various surgical time point measures was described with the Spearman rank correlation. HALS aortic grafting was successful in the last 8 pigs. The first 2 pigs required conversion to open repair, and the graft of the third and fourth animals occluded early. Median operative time was 115 minutes (range: 75 to 205), median intestinal retraction time was 28 minutes (range: 10 to 40), median aortoiliac dissection time was 30 minutes (range: 20 to 60), and median aortic cross-clamp time was 48 minutes (range: 35 to 82). The Spearman rank correlations and p values between the order of the procedure and the intestinal retraction time, aortoiliac dissection time, clamping time, and total operative time were –0.62 (0.06), –0.47 (0.17), –0.69 (0.03), and –0.83 (0.03), respectively. HALS facilitates intestinal retraction and completion of laparoscopic aortoiliac dissection. It offers adequate exposure in pigs for aortic grafting and allows open sutured aortic anastomosis. The learning curve for HALS aortic surgery in a porcine model is short and within reach of surgeons with standard laparoscopic surgery skills, since no laparoscopic suturing is required. Training on this porcine model may be an efficient and safe way to introduce surgeons to HALS for aortoiliac reconstruction.