Clinical and safety outcomes of laparoscopic nephrectomy with renal autotransplantation for the loin pain‐hematuria syndrome: a 14‐year longitudinal cohort study
AbstractObjectiveThe objective of this study is to assess clinical and safety outcomes after laparoscopic nephrectomy with autotransplantation for loin pain‐hematuria syndrome (LPHS).MethodsWe conducted telephone interviews using structured questionnaires and retrospectively reviewed data on all patients who underwent laparoscopic nephrectomy with autotransplantation for LPHS between January 2000 and May 2014.ResultsA total of 24 laparoscopic nephrectomies with renal autotransplantation of 21 patients with LPHS were reviewed. Eighty‐three per cent were female with a mean age of 31 years. Postoperatively, graft loss resulting in subsequent nephrectomy occurred in two patients; However, no patients died (median follow‐up = 22 months, range 5 to 78 months) or required dialysis (median follow‐up = 10 months, range 0.2 to 178 months). There was no significant difference in estimated glomerular filtration rate (eGFR) before and after surgery (100 ± 22 vs. 97 ± 23 mL/min/1.73 m2; P = 0.37). Among 14 patients (16 autotransplantation) with telephone follow‐up, 14 (88%) resulted in pain relief and no operation resulted in worsening pain. All procedures resulted in immediate pain relief; pain recurrence was reported after two procedures. However, those patients had pain‐free period up to 36 months. The quality of life was better after 15 (94%) autotransplantation with higher employment rate (44% vs. 69%; P = 0.04). Two patients with graft loss reported better pain control and quality of life.ConclusionsRenal autotransplantation is a possible treatment option for LPHS refractory to conservative medical treatment. It can offer pain relief and better quality of life. Despite postoperative risk, it seems to be safe for survival and renal outcomes.
Stapled Aortic Anastomoses: A Minimally Invasive, Feasible Alternative to Videoscopic Aortic Suturing?
Widespread applications of totally laparoscopic aortic reconstructions have been limited by the long cross-clamp time required to suture the aortic anastomosis despite improvement in instrumentation. The authors' hypothesis was that a “one-step anastomosis concept” using an intraluminal stapler would allow shorter cross-clamp time but similar patency and imperviousness as videoscopic suturing techniques. An intraluminal stapler (Endopath-ILS, Ethicon) with a modified anvil was used to perform videoscopic-assisted thoracic aorta-to-iliac artery bypass with a 21 mm by 8 mm polytetrafluoroethylene (PTFE) graft in 22 sheep through a minimally invasive approach using a 5 cm thoracotomy. The graft-to-iliac artery anastomoses were hand sutured through a flank incision. Twelve sheep were used to establish the technique and 10 subsequent animals constituted the study group. Aortic cross-clamp time, imperviousness, and need for additional sutures were recorded and compared to previously reported data using videoscopic suturing in pigs. Patency was assessed by comparing lower limb arterial pressures. Macroscopic and microscopic examinations of the anastomoses were performed at different time-points within the first 3 months. Videoscopic-assisted stapled anastomoses were also performed on atherosclerotic aortas of 3 human cadavers. Stapled anastomoses between the thoracic aorta and PTFE graft were completed in 8 of 10 animals. Two animals were euthanized after stapler failure and anastomotic bleeding. Sutures to strengthen the anastomosis had to be used in 4 cases. Mean aortic cross-clamp time in 8 successful cases was 4.3 ±2.9 minutes (range 2–11 minutes) and was significantly shorter than clamp time of videoscopic suturing technique (48.7 ±9.4 minutes, p<0.0001). Imperviousness was good or excellent in 4 animals and fair in 4 animals. All anastomoses were patent at the end of the procedure. Examination of the anastomosis of the 2 failed interventions showed medial aortic tear surrounding the anastomosis in 1 case and misfired staples in the other. No graft occlusion was noted during follow-up ranging from 0 to 12 weeks. At the time of harvest, no bleeding was noted after epinephrine and volume infusion to increase mean arterial pressure to 200 mm Hg for 15 minutes. Macroscopic examination of the anastomoses revealed adequate healing with circumferential stapling of the prosthesis to the aortic wall and no stenosis or thrombus except in 1 false aneurysm (1/7, 14%). Surface electron microscopy showed cells coverage of the anastomosis surface. When applied on human cadaver thoracic and abdominal aorta with atherosclerotic changes, clamping times of less than 5 minutes were achieved. However, imperviousness tested with saline was poor. An automatic stapling device allows performance of a graft-to-aorta anastomosis through a minimally invasive approach with shorter clamping time than a videoscopic suturing technique. However, the current technique of aortic stapling is unreliable and further improvements are needed.