Citations

Mayo Clinic

Clear

374 citation(s) found for "Vargas, A".

Feasibility, Safety, and Efficacy of Pulsed Field Ablation for Ventricular Arrhythmias: Insights From a Large Health System Registry in the United States
Fatunde, Olubadewa A. , Vemulapalli, Hema Srikanth , Rodriguez, Juan F. , Rodriguez-Riascos, Juan F , Vemulapalli, Hema S , Somappa, Aakash , Estrada-Vargas, Camilo A , Fatunde, Olubadewa A , Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J , McLeod, Christopher J , El Masry, Hicham , Deshmukh, Abhishek J , Kella, Danesh K , Killu, Ammar M , Mulpuru, Siva K , Sardana, Mayank , Scott, Luis R , Sugrue, Alan M, Srivathsan, Komandoor , Prasitlumkum, Narut , Rojas, Carlos, Prajapati, Poojan , Vijayakumar, Keerthika , Kapa, Suraj , Nguyen, Duy, Asirvatham, Samuel J. , Madhavan, Malini , McLeod, Christopher J. , Masry, Hicham El , Deshmukh, Abhishek , Kella, Danesh , Killu, Ammar M. , Mulpuru, Siva K. , Scott, Luis R. , Sugrue, Alan , Srivathsan, Komandoor

Journal of Cardiovascular Electrophysiology | September 15, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/jce.70503 | PMID 42743395 Get It

ABSTRACT Background Pulsed field ablation (PFA) is an emerging non‐thermal ablation modality with proven safety in atrial arrhythmia ablation. However, data on its performance for ventricular arrhythmias (VA) remain limited. Objective To evaluate the feasibility, safety, and efficacy of PFA for complex VA in a multicenter real‐world US registry. Methods This retrospective study included consecutive patients undergoing PFA for ventricular tachycardia (VT) or premature ventricular contractions (PVCs) at three Mayo Clinic centers (April 2024 to July 2025). The primary feasibility outcome was the successful delivery of PFA lesions to the intended target substrate. Primary efficacy outcomes included acute procedural success; sustained VT recurrence requiring implantable cardioverter‐defibrillator (ICD) shocks or multiple antitachycardia pacing therapies; and ≥ 80% reduction in PVC burden. Safety outcomes included procedural complications, valvular function, thromboembolic events, renal function, and conduction disturbances. Results Twenty‐six patients were included (13 PVC, 13 VT). Acute success was achieved in all VT ablations (69.2% complete; 30.8% partial) and in 92.3% of PVC ablations. Complications occurred in 11.5% of patients (transient LBBB [ n = 1] and vascular complications [ n = 2]). No thromboembolic events, intracardiac thrombus, or acute kidney injury were observed. Lesions near the mitral valve apparatus did not worsen mitral regurgitation, including in patients with pre‐existing valve disease. After a median follow‐up of 365 days, one patient experienced VT recurrence requiring ICD shocks. Estimated recurrence‐free survival after VT ablation was 61.5% at 12 months; 58.3% of PVC patients achieved ≥ 80% burden reduction. Conclusion PFA for VA appears feasible and acutely effective, with a low rate of procedure‐related complications. While acute success was high, long‐term outcomes were acceptable for VT ablation and relatively modest for PVC ablation, highlighting the need for continued refinement of technology and energy‐delivery strategies. Larger prospective studies are warranted.
Endoscopic Ultrasound-Guided Gastroenterostomy for Gastric Outlet Obstruction: A Comparison of Duodenal Versus Jejunal Placement on Patient Outcomes
Khan, Rishad , Law, Ryan , Guralwar, Chinmay , Bauss, Jacob, Suman, Garima , Han, S, Buttar, Navtej, Song, Louis–Michel Wong Kee, Law, Ryan J, AbiMansour, Jad P. , Vargas, Eric J , Wong Kee Song, Louis-Michel, Storm, Andrew C , Chandrasekhara, Vinay , Bauss, Jacob M. , Han, Samuel, Vargas, Eric J. , Dayyeh, Barham K. Abu , Buttar, Navtej , Storm, Andrew C. , Chandrasekhara, Vinay

Endoscopy International Open | July 11, 2026 | Volume: 14 | Issue: CP | Pages: No page available

10.1055/a-2913-6628 | PMID 42583363 Get It

Abstract Background and Aims EUS-guided gastroenterostomy (EUS-GE) is an effective option to palliate symptoms of gastric outlet obstruction (GOO). While the jejunum is conventionally targeted (EUS-GJ), targeting the duodenum (EUS-GD) may offer clinical advantages. Outcomes were compared for EUS-GJ and EUS-GD. Methods Adult patients who underwent EUS-GE for GOO between 2020 and 2024 were included and categorized as an EUS-GD if the stent entered the transverse or ascending duodenum or an EUS-GJ if the stent entered more distally. The primary outcome was clinical success (soft diet tolerance at 7 days). Secondary outcomes included adverse events (AEs), stent misdeployment, and unplanned endoscopic reintervention. Baseline demographic variables and outcomes were compared with statistical significance at p < 0.05. Results Of the 139 included patients (median age 67 years (IQR 61–74); 41% female), 105 underwent EUS-GJ and 34 underwent EUS-GD. Clinical success was 98% for EUS-GJ and 94% for EUS-GD (p = 0.25). The misdeployment rate was 7% for EUS-GJ and 0% for EUS-GD (p = 0.19). The AE rate was 22% for EUS-GJ and 12% for EUS-GD (p = 0.23). There were no significant differences for stent obstruction (EUS-GJ 12% vs. EUS-GD 6%), bleeding (2% vs. 6%), perforation (4% vs. 0%), stent migration (1% vs. 0%), infection (3% vs. 0%), and unplanned reintervention (14% vs. 9%). Conclusion Both EUS-GJ and EUS-GD demonstrate high clinical success with no significant differences in adverse event rates. These data can support intraprocedural decision-making for endoscopists performing EUS-GE.
Dual Coronary Sinus Lead Strategy to Avoid Tricuspid Valve Traversal in Biventricular Pacing
Baqal, Omar , Liu, Michael B. , Rodriguez, Juan F. , Kanaan, Christopher , Somappa, Aakash , Estrada‐Vargas, Camilo A., Srivathsan, Komandoor, Rodriguez-Riascos, Juan F , Kanaan, Christopher N , Baqal, Omar J , Liu, Michael , Estrada-Vargas, Camilo A , Asirvatham, Samuel J. , Srivathsan, Komandoor

Pacing and Clinical Electrophysiology | July 4, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1111/pace.70348 | PMID 42400389 Get It

ABSTRACT Patients requiring permanent pacing after tricuspid valve intervention present challenges due to the need to cross tricuspid valve prostheses. We report three cases of successful dual coronary sinus (CS) lead implantation for biventricular pacing following a range of tricuspid interventions—surgical tricuspid annuloplasty, transcatheter edge‐to‐edge repair, and transcatheter tricuspid valve replacement. The approach avoided tricuspid valve traversal, was technically feasible and resulted in satisfactory pacing performance without procedural complications. Dual CS lead configurations were individualized based on CS anatomy and pacing characteristics. The degree of QRS narrowing achieved varied according to lead location and ventricular activation patterns, highlighting the importance of individualized lead placement strategies and device programming. Dual CS lead pacing may represent a viable alternative for biventricular pacing in selected patients with prior tricuspid valve interventions. Larger studies are needed to evaluate long‐term outcomes and define the optimal role of this approach among available pacing strategies in this patient population.
Post-ERCP pancreatitis after self-expanding metal stent placement in patients with pancreatic versus non-pancreatic malignant biliary obstruction
AbiMansour, Jad P. , Petersen, Bret T. , Valls, Eric J. Vargas, Law, Ryan, Han, Samuel, AbiMansour, Jad , Vargas Valls, Eric J, Petersen, Bret T. , Vargas, Eric J. , Law, Ryan, Chandrasekhara, Vinay

Therapeutic Advances in Gastrointestinal Endoscopy | June 23, 2026 | Volume: 19 | Issue: No issue available | Pages: No page available

10.1177/26317745261458987 | PMID 42368878 Get It

Background: Self-expanding metal stents (SEMS) are recommended for the endoscopic palliation of distal malignant biliary obstruction (DMBO). Placement of SEMS during endoscopic retrograde cholangiopancreatography (ERCP) has been associated with an increased risk of post-ERCP pancreatitis (PEP). Objectives: The aim of this study is to evaluate rates of PEP in patients who underwent SEMS placement for pancreatic versus non-pancreatic malignancy. Design: Retrospective Cohort Study. Methods: Patients who underwent SEMS placement for DMBO between June 2017 and May 2021 were identified retrospectively from a procedural billing database. PEP incidence was compared between pancreatic and non-pancreatic DMBO groups and multivariate logistic regression was performed to identify risk factors for PEP. Results: A total of 488 individuals were identified, with 395 (80.9%) cases of DMBO due to pancreatic and 93 (19.1%) due to non-pancreatic malignancy. Stent types included 124 (25.4%) fully covered (FCSEMS) and 364 (74.6%) uncovered metal stents (UCSEMS). The overall rate of PEP in the cohort was 6.3% with no significant difference between pancreatic and non-pancreatic etiologies (6.1% vs 7.5%, p = 0.606). When adjusted for age <50 years old, female sex, and pancreatic stent placement, a non-pancreatic malignancy was not associated with an increased risk of PEP (OR 0.83, 95% CI 0.36–2.15). Conclusion: No statistically significant difference in PEP rates was seen after biliary sphincterotomy and SEMS placement for palliation of DMBO in patients with pancreatic versus non-pancreatic malignancies.
Fairness and Bias Management in Health AI: consensus-Based Recommendations for Best Practices Across the AI Lifecycle
Ghane, Merage , Elmore, Matthew , Stapleton, Shawn , Owens, Kellie , Khalid, Sana , Delonay, Allie, Youssef, Alaa , Chisunka, Mwisa, Rariy, Chevon, Vargas, Ariadna, Bonis, Julio , Economou-Zavlanos, Nicoleta , Talby, David , Owens, Kellie , Youssef, Alaa , Bonis, Julio , Economou-Zavlanos, Nicoleta J , Elmore, Matthew , Dankwa‐Mullan, Irene

The American Journal of Bioethics | June 10, 2026 | Volume: No volume available | Issue: No issue available | Pages: 1-6

10.1080/15265161.2026.2677391 | PMID 42267797 Get It

Reverse EUS-GJ: EUS guided decompression of Excluded Stomach Gastric Outlet Obstruction (eGOO) after Roux-en-Y Gastric Bypass Surgery
Valls, E Vargas, Gala, K, Ghanem, O, Abimansour, J, Han, S, Law, E, Dayyeh, B Abu, Chandrasekhara, V, Vargas, Eric J. , Ghanem, Omar M. , AbiMansour, Jad P. , Han, Samuel, Dayyeh, Barham K. Abu , Chandrasekhara, Vinay

Endoscopy | June 5, 2026 | Volume: 58 | Issue: S 03 | Pages: S809-S810

10.1055/s-0046-1822242 Get It

Mechatronic Design and Development of a Lower-Limb Exoskeleton System Based on Knee Joint Biomechanical Principles Using Electro-Pneumatic Actuation with an Embedded EMG Controller for Experimental Validation in Elderly Gait Rehabilitation Support
Nacarino, Adrian , Sanchez, Bryan , Charapaqui, Sandra , Charapaqui, Renzo , Maldonado-Gómez, R. R. , Mendoza-Arias, Leslie M. , Barra, Daira De La , Ccellcaro, Cristina , Cornejo, José , Vargas, Mariela , Castro, Robert, Cornejo, Jorge , Salguero, Robert Castro , Maldonado-Gómez, Renzo R , de la Barra, Daira , Cornejo, Jose , Vargas, Mariela , Cornejo, Jorge , Palomares, Ricardo , Cornejo, Jorge

Bioengineering | June 3, 2026 | Volume: 13 | Issue: 6 | Pages: 644

10.3390/bioengineering13060644 | PMID 42351888 Get It

Stroke is the second leading cause of death globally and a major contributor to lower-limb disability, affecting gait, balance, and functional independence in elderly populations. While robot-assisted rehabilitation has demonstrated effectiveness in motor recovery, access remains limited due to high costs and geographic barriers, particularly in Latin America. This study presents ExoKnee, a low-cost knee exoskeleton designed through biomimetic principles and 3D-printed fabrication as a proof-of-concept device targeting gait rehabilitation in elderly adults. The system integrates a single-degree-of-freedom pneumatic actuator controlled by electromyography (EMG) signals from the quadriceps muscle, enabling knee flexion and extension (90° to 180°). The design was evaluated through finite element analysis and dynamic simulations in MATLAB/Simulink R2024a under constant, stepwise, and sinusoidal reference inputs in a digital-twin environment. Expert validation using the Content Validity Coefficient yielded a mean score of 0.8747, reflecting preliminary expert agreement on the conceptual design’s coherence and relevance. The prototype demonstrated controlled movements through a 6-bar pneumatic system with EMG-triggered relay activation, validated at the proof-of-concept level through simulation and single-subject threshold calibration. ExoKnee addresses critical gaps by offering an anthropometrically informed, biosignal-driven, and locally manufacturable rehabilitation platform for low- and middle-income countries, pending clinical validation. Future work will focus on clinical trials and adaptive EMG control strategies.
Aspirin Use and Liver-Related Outcomes in Metabolic Dysfunction-Associated Steatotic Liver Disease: A Systematic Review and Meta-Analysis
Jamal, Fares , Elshaer, Amani, Claassen, Pierce L., Viggiano, Taylor, Barnhill, Michele , Chascsa, David M. , Aqel, Bashar , Hamad, Abdullah , Chascsa, David M , Aqel, Bashar A. , Lizaola-Mayo, Blanca C, Jamal, Fares , Elshaer, Amani , Viggiano, Taylor , Barnhill, Michele , Vargas, Hugo E. , Lizaola‐Mayo, Blanca

Biomedicines | June 1, 2026 | Volume: 14 | Issue: 6 | Pages: 1249

10.3390/biomedicines14061249 | PMID 42351677 Get It

Background: Given aspirin’s biologic plausibility for antifibrotic and antineoplastic effects, we conducted a systematic review and meta-analysis to examine the association between aspirin use and major liver-related outcomes in metabolic dysfunction-associated steatotic liver disease (MASLD). To our knowledge, this is the first systematic review and meta-analysis restricted exclusively to patients with biopsy- or registry-confirmed MASLD. Methods: A comprehensive search of Ovid MEDLINE, Ovid EMBASE, Scopus, and Web of Science was performed in October 2025. Studies enrolling adults with a confirmed MASLD diagnosis were included; those with viral hepatitis or alcohol-related liver disease were excluded. Outcomes assessed included hepatocellular carcinoma (HCC), fibrosis progression, cirrhosis, all-cause and liver-related mortality, gastrointestinal (GI) bleeding, hemorrhagic stroke, and liver disease progression. Hazard ratios (HRs) with 95% CIs were pooled using random-effects models. Heterogeneity was assessed using I2 statistics. Results: Seven studies met the eligibility criteria, with approximately 720,000 individuals included. Pooled analysis showed that aspirin use was associated with a significantly lower HCC risk (HR 0.59; 95% CI 0.43–0.81; I2 = 83%). No statistically significant association was found between aspirin use and cirrhosis incidence (HR 0.55; 95% CI 0.13–2.37; I2 = 83.4%) or GI bleeding (HR 1.11; 95% CI 0.74–1.66; I2 = 98.9%). Among the two studies that explored all-cause mortality, aspirin was associated with a modest but statistically significant reduction in all-cause mortality (HR 0.86; 95% CI 0.78–0.95; I2 = 0%). Conclusions: Aspirin use is associated with a reduced risk of HCC and all-cause mortality in MASLD without significantly increasing GI bleeding or hemorrhagic strokes. These associations may reflect aspirin’s anti-inflammatory properties in liver disease. Further RCTs are needed to verify the causal role of aspirin in MASLD management.
Efficacy and safety outcomes of biweekly compared with standard triweekly gemcitabine/nab-paclitaxel in advanced pancreatic cancer: A systematic review and meta-analysis.
Castillo, Victor Andres, Salolin-Vargas, Vanessa Pamela, Padilla-Zambrano, Huber, Saldana, Mauricio Alejandro, Cerino-Peñaloza, Maria Susana, Fernandez, Wilfor Diaz , Maaliki, Liya, Ahmed, Abdallfatah, Luján, Mauricio , Vargas, Vanessa Pamela Salolin , Cerino-Peñaloza, María Susana

Journal of Clinical Oncology | May 28, 2026 | Volume: 44 | Issue: 16_suppl | Pages: No page available

10.1200/jco.2026.44.16_suppl.e16405 Get It

e16405 Background: Pancreatic cancer remains one of the most lethal malignancies, with a rising incidence and persistently poor survival outcomes. Gemcitabine plus nab-paclitaxel is an established standard regimen for advanced disease, however, the conventional triweekly schedule is frequently associated with significant toxicity. Biweekly dosing has been proposed to enhance tolerability while maintaining efficacy, although evidence remains limited and heterogeneous. The objective was to evaluate the efficacy and safety of biweekly versus standard gemcitabine/nab-paclitaxel in patients with advanced pancreatic cancer. Methods: A systematic search of PubMed, Embase, and the Cochrane Library was conducted to identify studies comparing Biweekly versus Standard Triweekly: gemcitabine / nab-paclitaxel in patients with advanced pancreatic cancer. The primary outcomes of interest included partial response, and treatment-related toxicities, specifically anemia, neutropenia, and use of growth factors. Statistical analyses were performed using Review Manager. Heterogeneity was assessed using the I 2 statistic, and risk of bias was evaluated using the ROBINS-I tool. Results: A total of 1357 patients from eight observational studies were included. Comparative analysis showed no significant difference in partial response between biweekly and standard triweekly gemcitabine/nab-paclitaxel in patients with advanced pancreatic cancer with a risk ratio (RR) of 0.77 (95% CI 0.57,1.04, p = 0.09). Similarly, no significant differences were observed between regimens in the incidence of anemia (RR = 1.09; 95% CI 0.74–1.59; p = 0.66) or neutropenia (RR = 1.09; 95% CI 0.86–1.37; p = 0.48). however, growth factor use was significantly lower with biweekly dosing (RR = 0.71; 95% CI 0.58–0.87; p = 0.0009). Overall survival was comparable between groups RR = 1.02 (95% CI 0.71, 1.45 p = 0.93). Conclusions: Administration of gemcitabine/nab-paclitaxel biweekly yielded clinical outcomes and safety profiles comparable to the conventional regimen, while significantly reducing the need for growth factors as supportive care. These data suggest that a biweekly regimen could be an effective alternative; however, further prospective randomized studies are necessary to verify these findings and better understand their clinical application.
Noisy probing dose facilitated dose prediction for pencil beam scanning proton therapy: Physics enhances generalizability
Zhang, Lian , Zhang, Xiao, Li, Mingzhu, Vargas, Carlos , Keole, Sameer R., Stützer, Kristin , Liu, Tianming , Wong, William W. , Vora, Sujay A., Feng, Hongying , Holmes, Jason , Zhang, Xiao, Liu, Zhengliang , Li, Mingzhu, Sio, Terence T. , Li, Sheng , Shen, Jiajian , Liu, Wei

Medical Physics | May 27, 2026 | Volume: 53 | Issue: 5 | Pages: No page available

10.1002/mp.70509 | PMID 42192246 Get It

Abstract Background Accurate and efficient dose calculation is essential for online adaptive planning in proton therapy. Deep learning (DL) has shown promising dose prediction results for pencil beam scanning proton therapy (PBSPT) in recent years, but existing DL‐based dose prediction methods still suffer from limited generalizability and an inability to effectively handle outlier clinical cases. This may lead to inaccurate dose delivery to targets or excessive irradiation to organs at risk (OARs), thereby compromising the safety and efficacy of online adaptive proton therapy. Purpose To design a physics‐aware and generalizable AI‐based PBSPT dose prediction method that incorporates underlying physics to enhance generalizability, particularly in handling outlier clinical cases. Methods This study analyzed PBSPT plans of 103 prostate (93 for training and 10 for testing) and 78 lung cancer patients (68 for training and 10 for testing) from our institution, with each case comprising CT images and structure sets. Using the doses generated by our Monte Carlo‐based dose engine as the reference standard, we compared three methods: the region of interest (ROI)‐based method, the beam mask and sliding window method, and the proposed noisy probing dose method, which rapidly generates a low‐statistics dose via uniformly weighted spots on an expanded spot‐placement target volume without optimization. To evaluate the generalizability of these methods to rare treatment planning scenarios, 12 cases with uncommon beam angles or prescription doses were used to assess their performance, which was evaluated using dose‐volume histogram (DVH) indices, 3D Gamma passing rates (3%/2 mm/10%), and Dice coefficients for dose agreement, while prediction times were measured to gauge model efficiency. Results The proposed noisy probing dose method consistently outperformed the ROI‐based and beam mask baselines across all evaluated metrics, with more accurate dose agreement and superior generalizability. For DVH indices, the noisy probing dose method achieved the smallest deviation in clinical target volume (CTV) dose coverage: in prostate cancer, CTV D98 deviation was reduced by 45% (from 0.53 ± 0.22 Gy [RBE] for ROI‐based) and 29% (from 0.41 ± 0.28 Gy [RBE] for beam mask) to 0.29 ± 0.06 Gy [RBE]; in lung cancer, similar improvements were observed, with CTV D98 deviations reduced to 0.34 ± 0.12 Gy [RBE]. The 3D Gamma passing rates improved to 99.65% ± 1.15% for prostate targets and 97.04% ± 1.17% for lung targets. The dice coefficients of the 90% iso‐dose lines were also the highest with the noisy probing dose method (prostate: 0.983 ± 0.005; lung: 0.967 ± 0.01). For the 12 outlier cases, the noisy probing dose method maintained superior generalizability, yielding higher 3D Gamma passing rates (prostate targets: 96.79% ± 0.83%, OARs: 94.29% ± 1.01%; lung targets: 93.38% ± 1.34%, OARs: 93.95% ± 1.32%), demonstrating robust generalizability to rare clinical scenarios. The dose predictions for all testing cases were completed within 0.3 seconds. Conclusions A novel noisy probing dose method was proposed for PBSPT dose prediction in prostate and lung cancer patients. By embedding more proton‐specific physics, this method demonstrated an improvement in the generalizability of dose prediction.