Abstract Objective Using a US Food and Drug Administration (FDA) emergency use authorization (EUA) reverse transcription polymerase chain reaction (RT-PCR) method, we examined the analytic performance accuracy of saliva specimens as compared to nasopharyngeal (NP) specimens in symptomatic patients. Correlation between test results and symptoms was also evaluated. Methods Over a 5-week period in 2020, 89 matched saliva and nasopharyngeal swabs were collected from individuals exhibiting symptoms consistent with SARS-CoV-2. Specimens were tested with an FDA EUA-approved RT-PCR method, and performance characteristics were compared. Results The concordance rate between saliva and nasopharyngeal testing was 93.26%. The mean cycle threshold value of saliva when compared to the NP specimen was 3.56 cycles higher. As compared to NP swab, saliva testing demonstrates acceptable agreement but lower sensitivity. Conclusion When compared to a reference method using NP swabs, the use of saliva testing proved to be a reliable method. Self-collected saliva testing for SARS-CoV-2 allows for a viable option when trained staff or collection materials are in short supply.
Ultrafast dynamic computed tomography myelography for the precise identification of high-flow cerebrospinal fluid leaks caused by spiculated spinal osteophytes
OBJECT Precise localization and understanding of the origin of spontaneous high-flow spinal CSF leaks is required prior to targeted treatment. This study demonstrates the utility of ultrafast dynamic CT myelography for the precise localization of high-flow CSF leaks caused by spiculated spinal osteophytes. METHODS This study reports a series of 14 patients with high-flow CSF leaks caused by spiculated spinal osteophytes who underwent ultrafast dynamic CT myelography between March 2009 and December 2010. There were 10 male and 4 female patients, with an average age of 49 years (range 37–74 years). The value of ultrafast dynamic CT myelography in depicting the CSF leak site was qualitatively assessed. RESULTS In all 14 patients, ultrafast dynamic CT myelography was technically successful at precisely demonstrating the site of the CSF leak, the causative spiculated osteophyte piercing the dura, and the relationship of the implicated osteophyte to adjacent structures. Leak sites included 3 cervical, 11 thoracic, and 0 lumbar levels, with 86% of the leaks occurring from C-5 to T-7. Information obtained from the ultrafast dynamic CT myelogram was considered useful in all treated CSF leaks. CONCLUSIONS Spinal osteophytes piercing the dura are a more frequent cause of high-flow CSF leaks than previously recognized. Ultrafast dynamic CT myelography adds value beyond standard dynamic myelography or digital subtraction myelography in the diagnosis and anatomical characterization of high-flow spinal CSF leaks caused by these osteophytes. This information allows for appropriate planning for percutaneous or surgical treatment.
Immediate Cerebral Angiography and Mechanical Fragmentation of Cerebral Embolus after Percutaneous Myocardial Revascularization
Background and objective Sacroplasty has emerged as a treatment option for patients with painful osteoporotic sacral insufficiency fractures. We report short-term outcomes in a consecutive cohort of patients treated with sacroplasty. Methods We retrospectively reviewed 57 patients treated with sacroplasty for painful osteoporotic sacral fractures at our institution between 2004 and 2011. An 11-point numerical rating scale pain score was recorded at rest and at activity pre- and post-procedure. Opioids prescribed to the patient both pre- and post-procedure were recorded. Results Mean duration of pain prior to sacroplasty was 3 weeks (IQR 2–5). Procedural complications were minimal. Median post-procedure follow-up time was 2.5 weeks (IQR 1–5) among 45 patients with available data. Thirty-seven (82%) of the 45 patients experienced a numerical or descriptive decrease from initial pain at follow-up. Median activity pain scores collected from 13 patients decreased from 10 (IQR 8.5–10) pre-procedure to 6 (IQR 4–6.8) post-procedure (p<0.0001), and median rest pain scores collected from 29 patients decreased from 7 (IQR 4–8.5) to 2 (IQR 1–3.5)(p<0.0001). Twenty-two (76%) of 29 patients had at least a 30% decrease in rest pain scores. The median number of opioids prescribed per patient decreased from 1 (IQR 1–2) pre-procedure to 0 (IQR 0–1) post-procedure (p<0.0001). Thirty-four of 57 patients (60%) had decreased opioid usage, 15 (26%) patients had unchanged usage and 8 (14%) had increased usage. Conclusions Our series demonstrates that sacroplasty is a safe and effective treatment in patients with painful osteoporotic insufficiency fractures.
The Role of Digital Subtraction Myelography in the Diagnosis and Localization of Spontaneous Spinal CSF Leaks
Abstract Vertebroplasty alters spinal biomechanics and may lead to incident vertebral fractures. The endplate localization of prevalent and incident fractures was evaluated in 86 patients. In the absence of vertebroplasty, superior endplate fractures predominate. After the procedure, inferior endplate fractures are disproportionately common in adjacent vertebrae immediately above the treated level, potentially supporting a causative relationship between vertebroplasty and incident fractures. Introduction: To determine retrospectively whether new-onset fractures after vertebroplasty tend to cluster in the endplate immediately adjacent to the cemented vertebra. Materials and Methods: Institutional Review Board approval and patient consent for use the use of medical records were obtained for this study. We performed a retrospective review of patients with new (incident) vertebral fractures after vertebroplasty. The median age for these patients was 72.5 years, and 58 (67.4%) were women. Fractures were diagnosed on the basis of MRI or bone scan and were catalogued based on their location within the vertebral body (superior endplate, inferior endplate, or holo-vertebral). χ2 and generalized estimating equation (GEE) analyses were used to compare the distribution of fracture subtypes among pre-existing (prevalent) and incident fractures. Results: The patients had 313 prevalent osteoporotic vertebral fractures and were treated at 137 vertebral levels. Among prevalent fractures, superior endplate fractures predominated (57% superior, 11% inferior; p < 0.0001). After vertebroplasty, 186 incident fractures developed in these 86 patients. Seventy-seven (41%) of these incident fractures occurred adjacent to treated vertebrae. Nonadjacent, incident fractures, like prevalent fractures, occurred predominantly along superior endplate. Incident fractures immediately above treated levels, however, localized disproportionately to the inferior endplate (30% superior, 57% inferior; p < 0.0001). Conclusions: There are an increased number of inferior endplate fractures of the vertebral body immediately cephalad to the treated level.