Back to Authors

Sloan, Lynne M.

Mayo Clinic

Mayo Clinic

Citations 28

Borrelia mayonii sp. nov., a member of the Borrelia burgdorferi sensu lato complex, detected in patients and ticks in the upper midwestern United States
Pritt, Bobbi S. , Respicio-Kingry, Laurel, Sloan, Lynne M., Schriefer, Martin E., Replogle, Adam J., Bjork, Jenna , Liu, Gong‐Ping , Kingry, Luke C. , Mead, Paul S. , Neitzel, David F., Schiffman, Elizabeth , Johnson, Diep K. Hoang, Davis, Jeffrey P., Paskewitz, Susan M. , Boxrud, David, Deedon, Alecia, Lee, Xia , Miller, Tracy K., Feist, Michelle, Steward, Christopher R., Theel, Elitza S. , Patel, Robin , Irish, Cole L., Petersen, Jeannine M., Patel, Robin , Kingry, Luke , Pritt, Bobbi S

International Journal of Systematic and Evolutionary Microbiology | August 24, 2016 | Volume: 66 | Issue: 11 | Pages: 4878-4880

10.1099/ijsem.0.001445 Get It

First Reported Case of Ehrlichia ewingii Involving Human Bone Marrow
Allen, Mr, Pritt, Bobbi S. , Sloan, Lynne M., Paddock, Christopher D. , Musham, Chaitanya K., Ramos, Jeanette M., Cetin, Neslihan, Rosenbaum, Eric , Pritt, Bobbi S

Journal of Clinical Microbiology | September 4, 2014 | Volume: 52 | Issue: 11 | Pages: 4102-4104

10.1128/jcm.01670-14 Get It

ABSTRACT A 65-year-old female with a history of multiple tick bites presented with fever and pancytopenia. Intracytoplasmic rickettsial morulae were detected on peripheral smear and bone marrow biopsy specimens, and PCR amplified Ehrlichia ewingii DNA from both specimens. To our knowledge, this is the first report of E. ewingii infection of human bone marrow.
Comparative Evaluation of Two Commercial Multiplex Panels for Detection of Gastrointestinal Pathogens by Use of Clinical Stool Specimens
Khare, Reeti , Espy, Mark J., Cebelinski, Elizabeth , Boxrud, David, Sloan, Lynne M., Cunningham, Scott A. , Pritt, Bobbi S. , Patel, Robin , Binnicker, Matthew J. , Patel, Robin , Pritt, Bobbi S , Cunningham, Scott A

Journal of Clinical Microbiology | August 7, 2014 | Volume: 52 | Issue: 10 | Pages: 3667-3673

10.1128/jcm.01637-14 Get It

ABSTRACT The detection of pathogens associated with gastrointestinal disease may be important in certain patient populations, such as immunocompromised hosts, the critically ill, or individuals with prolonged disease that is refractory to treatment. In this study, we evaluated two commercially available multiplex panels (the FilmArray gastrointestinal [GI] panel [BioFire Diagnostics, Salt Lake City, UT] and the Luminex xTag gastrointestinal pathogen panel [GPP] [Luminex Corporation, Toronto, Canada]) using Cary-Blair stool samples ( n = 500) submitted to our laboratory for routine GI testing (e.g., culture, antigen testing, microscopy, and individual real-time PCR). At the time of this study, the prototype (non-FDA-cleared) FilmArray GI panel targeted 23 pathogens (14 bacterial, 5 viral, and 4 parasitic), and testing of 200 μl of Cary-Blair stool was recommended. In contrast, the Luminex GPP assay was FDA cleared for the detection of 11 pathogens (7 bacterial, 2 viral, and 2 parasitic), but had the capacity to identify 4 additional pathogens using a research-use-only protocol. Importantly, the Luminex assay was FDA cleared for 100 μl raw stool; however, 100 μl Cary-Blair stool was tested by the Luminex assay in this study. Among 230 prospectively collected samples, routine testing was positive for one or more GI pathogens in 19 (8.3%) samples, compared to 76 (33.0%) by the FilmArray and 69 (30.3%) by the Luminex assay. Clostridium difficile (12.6 to 13.9% prevalence) and norovirus genogroup I (GI)/GII (5.7 to 13.9% prevalence) were two of the pathogens most commonly detected by both assays among prospective samples. Sapovirus was also commonly detected (5.7% positive rate) by the FilmArray assay. Among 270 additional previously characterized samples, both multiplex panels demonstrated high sensitivity (>90%) for the majority of targets, with the exception of several pathogens, notably Aeromonas sp. (23.8%) by FilmArray and Yersinia enterocolitica (48.1%) by the Luminex assay. Interestingly, the FilmArray and Luminex panels identified mixed infections in 21.1% and 13.0% of positive prospective samples, respectively, compared to only 8.3% by routine methods.
Inhibition Controls for Qualitative Real-Time PCR Assays: Are They Necessary for All Specimen Matrices?
Buckwalter, Seanne P., Sloan, Lynne M., Cunningham, Scott A. , Espy, Mark J., Uhl, J. R., Jones, Mary F. , Vetter, Emily A., Mandrekar, Jayawant N. , Cockerill, Franklin R., Pritt, Bobbi S. , Patel, Robin , Wengenack, Nancy L. , Patel, Robin , Pritt, Bobbi S , Cunningham, Scott A

Journal of Clinical Microbiology | April 16, 2014 | Volume: 52 | Issue: 6 | Pages: 2139-2143

10.1128/jcm.03389-13 Get It

ABSTRACT A retrospective analysis of 386,706 specimens representing a variety of matrix types used in qualitative real-time PCR assays determined the overall inhibition rate to be 0.87% when the inhibition control was added preextraction to 5,613 specimens and 0.01% when the inhibition control was added postextraction but preamplification in 381,093 specimens. Inhibition rates of ≤1% were found for all specimen matrix types except urine and formalin-fixed, paraffin-embedded tissue.
Cutaneous Manifestations of a Zoonotic Onchocerca Species in an Adult Male, Acquired in Nova Scotia, Canada
Lai, Jonathan, Walsh, Noreen M. , Pritt, Bobbi S. , Sloan, Lynne M., Gibson, Lawrence E. , Desormeau, Leon, Haldane, David, Pritt, Bobbi S

Journal of Clinical Microbiology | February 6, 2014 | Volume: 52 | Issue: 5 | Pages: 1768-1770

10.1128/jcm.03358-13 Get It

ABSTRACT A 65-year-old male with known hypertension and hypercholesterolemia sought medical attention because of a 3-month history of skin swelling on his upper back. Histopathology and molecular techniques were employed and identified an organism in the Onchocerca genus. This represents a very uncommon example of cutaneous infection by a zoonotic Onchocerca species.
Real-Time Qualitative PCR for 57 Human Adenovirus Types from Multiple Specimen Sources
Buckwalter, Seanne P., Teo, Rose, Espy, Mark J., Sloan, Lynne M., Smith, Thomas F., Pritt, Bobbi S. , Pritt, Bobbi S

Journal of Clinical Microbiology | December 15, 2011 | Volume: 50 | Issue: 3 | Pages: 766-771

10.1128/jcm.05629-11 Get It

ABSTRACT Human adenoviruses (HAdVs) are ubiquitous double-stranded DNA viruses that cause a wide array of diseases in humans including pharyngitis, pneumonia, gastroenteritis, hemorrhagic cystitis, and keratoconjunctivitis. They also cause life-threatening opportunistic infections in immunocompromised individuals and are responsible for outbreaks in certain populations. Diagnosis is traditionally by cell culture or antigen detection methods. However, some HAdVs can take up to 4 weeks to isolate, and diarrheagenic types 40 and 41 will not grow in routine cell culture. Therefore, the goal of this study was to design a rapid, real-time PCR assay to detect all known 57 HAdV types from multiple different specimen sources. Primers and fluorescence resonance energy transfer hybridization probes were designed to target a 185-bp region of the penton base gene of HAdV. The analytical sensitivity was determined to be 10 copies/μl for HAdV types showing exact primer/probe homology in specimen matrix. Using whole-virus strains, the analytical sensitivity for representative HAdV types ranged from 10 −1 to 10 3 50% tissue culture infective dose (TCID 50 )/ml. The assay demonstrated 100% sensitivity and 99% specificity. This real-time PCR assay provides a rapid method for the detection of all 57 known HAdV types from respiratory specimens, blood, stool, urine, and ocular swabs.
Three-Hour Molecular Detection of Campylobacter, Salmonella, Yersinia, and Shigella Species in Feces with Accuracy as High as That of Culture
Sloan, Lynne M., Nyre, Lisa M., Vetter, Emily A., Mandrekar, Jayawant N. , Patel, Robin , Cunningham, Scott A. , Patel, Robin

Journal of Clinical Microbiology | September 29, 2011 | Volume: 49 | Issue: 10 | Pages: 3725-3725

10.1128/jcm.05079-11 Get It

Comparison of Two Commercial Molecular Assays to a Laboratory-Developed Molecular Assay for Diagnosis of Clostridium difficile Infection
Karre, Tess, Sloan, Lynne M., Patel, Robin , Mandrekar, Jayawant N. , Rosenblatt, Jon E., Patel, Robin

Journal of Clinical Microbiology | December 2, 2010 | Volume: 49 | Issue: 2 | Pages: 725-727

10.1128/jcm.01028-10 Get It

ABSTRACT We compared two commercial PCR assays, the Prodesse ProGastro CD assay and the BD GeneOhm Cdiff assay, with a laboratory-developed Clostridium difficile toxin PCR assay with previously established performance characteristics. Results of all methods were in agreement for 333 (96%) of 346 stool specimens. No significant difference in performance among the assays was found ( P values, >0.05).
Three-Hour Molecular Detection of Campylobacter , Salmonella , Yersinia , and Shigella Species in Feces with Accuracy as High as Tha
Cunningham, Scott A. , Sloan, Lynne M., Nyre, Lisa M., Vetter, Emily A., Mandrekar, Jayawant N. , Patel, Robin , Patel, Robin , Cunningham, Scott A

Journal of Clinical Microbiology | June 3, 2010 | Volume: 48 | Issue: 8 | Pages: 2929-2933

10.1128/jcm.00339-10 Get It

ABSTRACT Campylobacter jejuni and Salmonella , Shigella , and Yersinia species (along with Shiga toxin-producing Escherichia coli ) are the most common causes of acute bacterial diarrheal disease in the United States. Current detection techniques are time-consuming, limiting usefulness for patient care. We developed and validated a panel of rapid PCR assays for the detection and identification of C. jejuni , C. coli , Salmonella , and Yersinia species and Shigella and enteroinvasive E. coli in stool samples. A total of 392 archived stool specimens, previously cultured for enteric pathogens, were evaluated by PCR. Overall, 104 stool specimens had been culture positive ( C. jejuni / coli [ n = 51], Salmonella species [ n = 42], Shigella species [ n = 6], and Yersinia species [ n = 5]). Compared to culture, the overall sensitivity and specificity of PCR detection of these organisms were 92 and 98% (96/104 and 283/288), respectively, from fresh or Cary Blair stool ( P = 0.41); 87 and 98% (41/47 and 242/246), respectively, from fresh stool ( P = 0.53); and 96 and 98% (55/57 and 41/42), respectively, from Cary Blair stool ( P = 0.56). For individual genera, PCR was as sensitive as the culture method, with the exception of Salmonella culture using selenite enrichment for which PCR was less sensitive than culture from fresh, but not Cary Blair ( P = 0.03 and 1.00, respectively) stools. This PCR assay panel for the rapid diagnosis of acute infectious bacterial diarrheal pathogens has a sensitivity and specificity equivalent to that of culture for stools in Cary Blair transport medium. Paired with reflexive culture of stools testing positive, this should provide an improvement in care for patients with acute infectious diarrheal disease.
Rapid and Sensitive Detection of Shiga Toxin-Producing Escherichia coli from Nonenriched Stool Specimens by Real-Time PCR in Comparison to Enzyme Immunoassay and Culture
Grys, Thomas E. , Sloan, Lynne M., Rosenblatt, Jon E., Patel, Robin , Patel, Robin , Grys, Thomas E

Journal of Clinical Microbiology | May 14, 2009 | Volume: 47 | Issue: 7 | Pages: 2008-2012

10.1128/jcm.02013-08 Get It

ABSTRACT Shiga toxin (Stx)-producing Escherichia coli (STEC) bacteria are a frequent cause of food-borne gastroenteritis, hemorrhagic colitis, and hemolytic uremic syndrome. Because antimicrobial agents are generally contraindicated in patients infected with STEC, a sensitive and specific diagnostic test with rapid turnaround is essential. Current culture methods may fail to detect non-O157 STEC. We evaluated a Stx gene real-time PCR assay using hybridization probes and the LightCycler instrument with 204 prospectively collected stool specimens, which were also tested for Stx by enzyme immunoassay (EIA) (ProSpecT STEC; Remel, Lenexa, KS) and by culturing on chromogenic agar (Chromagar O157; BD BBL, Sparks, MD). In addition, 85 archived stool specimens previously tested for Stx (by EIA) and/or E. coli O157:H7 (by culture) were tested by PCR. Sample preparation for PCR included mixing the stool in sterile water and extraction of nucleic acid using the MagNA Pure LC instrument (Roche Diagnostics). The PCR assay had 100% sensitivity and specificity compared to EIA and culture for specimens collected prospectively (4 of 204 specimens were positive) and compared to culture and/or EIA for archival specimens (42 of 85 specimens were positive). Both the EIA and PCR produced positive results from a specimen containing an O103 serotype STEC in the prospective specimens, and the PCR test detected three positive specimens that contained nonviable STEC in the archived specimens. The PCR assay demonstrated 100% sensitivity and specificity compared to EIA and/or culture and more rapid turnaround than either EIA or culture.