Diagnostic performance of plasma p‐tau217 and Aβ42/40 biomarkers in the outpatient memory clinic
Piura, Yoav , Lachner, Christian, Bornhorst, Joshua A. , Algeciras‐Schimnich, Alicia , Graff‐Radford, Neill R., Day, Gregory S. , Algeciras-Schimnich, Alicia , Piura, Yoav D, Figdore, Daniel J. , Day, Gregory S , Bornhorst, Joshua , Lachner, Christian , Graff‐Radford, Neill R.

Alzheimer's & Dementia | June 6, 2025 | Volume: 21 | Issue: 6 | Pages: No page available

10.1002/alz.70316 Get It

Abstract INTRODUCTION Plasma biomarkers of Alzheimer's disease (AD) represent accessible alternatives to positron emission tomography (PET) and cerebrospinal fluid (CSF)‐based biomarkers in well‐characterized cohorts. It remains to be determined whether performance is maintained in outpatient clinics comprised of patients with multiple causes of cognitive impairment. METHODS Plasma phosphorylated tau217 (p‐tau217) and amyloid beta (Aβ) 42/40 were measured in 509 patients evaluated in a tertiary‐care memory clinic. Biomarker performance was compared across diagnoses, referencing established cutpoints for positive and negative biomarkers. RESULTS Plasma p‐tau217 distinguished patients with diagnoses of symptomatic AD with 95% sensitivity and 82% specificity. Integration of Aβ42 measurements (p‐tau217/Aβ42) incrementally improved specificity (86%). Plasma p‐tau217 and p‐tau217/Aβ42 concentrations closely associated with established CSF biomarkers of AD (area under the curve [AUC]: 0.94 and 0.96, respectively). Reduced kidney function associated with elevated plasma p‐tau217 and p‐tau217/Aβ42 concentrations in patients without AD (referencing CSF biomarkers). DISCUSSION Plasma p‐tau217 and p‐tau217/Aβ42 concentrations demonstrated robust diagnostic performance in a heterogeneous clinical cohort; interpretation requires consideration of kidney function. Highlights Plasma phosphorylated tau217 (p‐tau217) reliably identified clinic patients with Alzheimer's disease. A two‐cutpoint strategy yielded definitive results in 86% of patients. Integration of plasma amyloid beta (Aβ; p‐tau217/Aβ42) minimally improved diagnostic performance. Plasma p‐tau217 levels were increased in patients with kidney dysfunction.
Differences in Alzheimer's disease blood biomarker stability: Implications for the use of tau/amyloid ratios
Schuder, Bethany J., Ashrafzadeh‐Kian, Susan , Gronquist, Tina, Bornhorst, Joshua A. , Algeciras‐Schimnich, Alicia , Algeciras-Schimnich, Alicia , Figdore, Daniel J. , Ashrafzadeh-Kian, Susan, Bornhorst, Joshua

Alzheimer's & Dementia | May 1, 2025 | Volume: 21 | Issue: 4 | Pages: No page available

10.1002/alz.70173 Get It

AbstractINTRODUCTIONWe compare the stability of phosphorylated tau (p‐tau)217, amyloid beta (Aβ)42, Aβ40, Aβ42/40, and p‐tau217/Aβ42 at different storage temperatures.METHODSTen ethylenediaminetetraacetic acid–plasma sample aliquots stored at frozen, refrigerated, and ambient temperatures were tested at various timepoints up to 30 days. The mean percent change from baseline was calculated.RESULTSAβ42 and Aβ40 concentrations decreased by >15% after 6 hours at ambient temperature and after 24 hours refrigerated, while p‐tau217 remained stable over 72 hours with < 10% deviation from baseline at either storage temperature. The Aβ42/40 ratio remained relatively constant as each analyte concentration decreased concurrently, while the p‐tau217/Aβ42 ratio deviated from baseline over time. All biomarkers were stable up to 30 days frozen.DISCUSSIONDifferences in the stability of Aβ42 and p‐tau217 may lead to altered p‐tau217/Aβ42 ratio results if samples are not handled properly during the pre‐analytical testing phase. Ideally, samples should be frozen promptly and sent to the laboratory frozen.Highlights Plasma phosphorylated tau (p‐tau)217, amyloid beta (Aβ)42, Aβ40, Aβ42/40, and p‐tau217/Aβ42 stability was assessed. P‐tau217 was stable, but Aβ42 and Aβ40 started decreasing by 6 hours at ambient temperature. The analyte stability differences led to falsely increased p‐tau217/Aβ42 ratios. Increases > 15% were seen in p‐tau217/Aβ42 after 6 hours at ambient temperature or 24 hours at 4°C.
AI-Augmented Kidney Stone Composition Analysis with Auto-Release Improves Quality, Efficiency, Cost–Effectiveness, and Staff Satisfaction
Day, Patrick L. , Rokke, Denise, Schneider, Laura, Abbott, Jillian, Holmen, Brenda, Wieczorek, Mikolaj A. , Carter, Rickey E. , Bornhorst, Joshua A. , Jannetto, Paul J. , Johnson, Patrick, Carter, Rickey E , Bornhorst, Joshua , Day, Patrick , Schneider, Laura, Holmen, Brenda, Johnson, Patrick W. , Kunze, Katie L.

The Journal of Applied Laboratory Medicine | December 19, 2024 | Volume: 10 | Issue: 2 | Pages: 305-314

10.1093/jalm/jfae146 Get It

Abstract Background We sought to evaluate key performance indicators related to an internally developed and deployed artificial intelligence (AI)-augmented kidney stone composition test system for potential improvements in test quality, efficiency, cost-effectiveness, and staff satisfaction. Methods We compared quality, efficiency, staff satisfaction, and financial data from the 6 months after the AI-augmented laboratory test system was deployed (test period) with data from the same 6-month period in the previous year (control period) to determine if AI-augmentation improved key performance indicators of this laboratory test. Results In the 6 months following the deployment (test period) of the AI-augmented kidney stone composition test system, 44 830 kidney stones were analyzed. Of these, 92% of kidney stones were eligible for AI-assisted interpretation. Out of these AI-eligible stones, 45% were able to be auto-released by the AI-augmented test system without human secondary review. Furthermore, the new AI-augmented kidney stone test system resulted in an apparent 40% reduction in incorrect laboratory results. Additionally, the new AI-augmented test system improved laboratory efficiency by 20%, improved staff satisfaction, and reduced the average analysis cost per kidney stone by $0.23. Conclusions The AI-augmented test system improved test quality, efficiency, cost-effectiveness and staff satisfaction related to this kidney stone composition test.
Performance Characteristics of a Calculated Index Control Method for the phi Multianalyte Assay with Algorithmic Analysis
Ewaisha, Radwa , Flieth, Tifani L., Ness, Karl M. , Bornhorst, Joshua A. , Algeciras-Schimnich, Alicia , Bornhorst, Joshua , Algeciras‐Schimnich, Alicia

The Journal of Applied Laboratory Medicine | November 8, 2024 | Volume: 10 | Issue: 2 | Pages: 221-234

10.1093/jalm/jfae110 Get It

Abstract Background Multianalyte assays with algorithmic analysis (MAAAs), such as the Prostate Health Index (phi), are increasingly utilized for generating disease risk scores. Currently, imprecision and bias in phi are not directly monitored by quality control (QC) assessment of the index but rather by QC assessment of individual components. This may not be adequately controlling for imprecision and bias in the calculated multicomponent phi value itself. Methods Inter- and intra-assay phi precision was compared to precision of the individual component assays. QC measurements from total prostate-specific antigen (PSA), free PSA, and p2PSA were used to calculate a single calculated phi QC metric (PHIc). The frequency of QC failure of PHIc, relative to individual components QC by Westgard rules (13S and 22S), was determined. The effects of varying analyte component assay bias on the resulting PHIc metric were also examined. Results Average measured phi imprecision (6.7% CV) was higher than individual phi analyte component imprecision (3.9–4.5% CV) across 2 Beckman Coulter Unicel DxI 800 instruments. A retrospective examination of PHIc QC over 84 quality control determinations was concurrently carried out for both PHIc and component assay failure patterns, which were dependent on SDs utilized for Westgard evaluation. Finally, reinforcing nonlinear changes in PHIc were observed in select cases of introduced simulated bias of individual component measurements. Conclusions An additional calculated phi QC measure can be introduced to monitor MAAA precision/bias, and in principle calculated index controls may represent a complementary supplemental QC method that could be applied to other MAAA indices.
Circulating Chromogranin A as a Surveillance Biomarker in Patients with Carcinoids—The CASPAR Study
Meng, Qing H. , Hálfdánarson, Þorvarður R. , Bornhorst, Joshua A. , Jann, Henning , Shaheen, Shagufta , Shi, Run‐Zhang , Schwabe, Andrej , Stade, Katrin , Halperin, Daniel M. , Halfdanarson, Thorvardur R , Bornhorst, Joshua

Clinical Cancer Research | October 25, 2024 | Volume: 30 | Issue: 24 | Pages: 5559-5567

10.1158/1078-0432.ccr-24-1875 Get It

Abstract Purpose: Gastroenteropancreatic neuroendocrine tumors (GEP-NET) are relatively indolent but can be more aggressive. The current recommendations for using serum chromogranin A (CgA) for patients with GEP-NET are equivocal. This study was designed to validate an automated CgA immunofluorescence assay for monitoring disease progression in patients with GEP-NET. Patients and Methods: A prospective, multicenter, blinded observational study was designed to validate an automated CgA immunofluorescence assay for monitoring disease progression in patients with GEP-NET. Tumor progression was evaluated with RECIST 1.1 by CT/MRI. An increase ≥50% above the prior CgA concentration to a value &gt;100 ng/mL in the following CgA concentration was considered positive. Results: A total of 153 patients with GEP-NET were enrolled. Using the prespecified cut-off of CgA change for tumor progression, specificity was 93.4% (95% confidence interval, 90.4%–95.5%; P &lt; 0.001), sensitivity 34.4% (25.6%–44.3%), positive predictive value 57.9% (45.0–69.8), negative predictive value 84.3% (80.5–87.6), and AUC 0.73 (0.67–0.79). Conclusions: Changes in serial measurements of serum CgA had a favorable specificity and negative predictive value, making this test a useful adjunct to routine radiographic monitoring.
Total Copper and Labile Bound Copper Fraction as a Selective and Sensitive Tool in the Evaluation of Wilson Disease
Bornhorst, Joshua A. , Bitzer, Anna C, Day, Patrick L. , Wermers, Michelle, Smith, Carin Y. , Pazdernik, Vanessa K, Pelto, Ryan, Sankaran, Banu, Quicquaro, Adam Michael , Jannetto, Paul J. , Smith, Carin Y , Day, Patrick , Bornhorst, Joshua , Pazdernik, Vanessa K

The Journal of Applied Laboratory Medicine | September 3, 2024 | Volume: 9 | Issue: 6 | Pages: 1014-1027

10.1093/jalm/jfae090 Get It

Abstract Background A dual filtration-based method for determination of serum labile bound copper (LBC) and LBC fraction (LBC/total copper) was developed. Reduced total copper, elevated LBC, and elevated LBC fraction have been reported in Wilson disease (WD). Methods To evaluate the diagnostic performance of these markers, samples were obtained from 21 WD treatment-naïve (WD-TN, no WD treatment or &lt;28 days of treatment) patients, 46 WD standard-of-care–treated (WD-SOC) patients, along with 246 patients representing other potential disorders of copper status. These were then compared to 213 reference interval population patients. Results Receiver operating characteristic curves for the reference population vs WD-TN yielded areas under the curve for total copper, LBC, and LBC fraction, of 0.99, 0.81, and 0.98, respectively. Using Youden cutoffs, sensitivity/specificity for WD-TN was 95%/97% for total copper, 71%/85% for LBC, and 95%/94% for LBC fraction. LBC values, but not total copper and LBC fraction, differed substantially between WD-TN and WD-SOC cohorts. We propose a dual model wherein total copper and LBC fraction results must agree to be classified as a “positive” or “negative” result for WD. This correctly classified 19/21 WD-TN patients as positive, and 194/213 reference interval patients as negative. The remaining “indeterminate” patients (representing approximately 9% of the reference and the WD-TN populations) exhibited conflicting total copper and LBC fraction results. When indeterminate results are excluded, this model exhibited apparent 100% sensitivity/specificity. Conclusions Agreement of total serum copper and LBC fraction classification may constitute an effective “rule-in” and “rule-out” assessment for WD-TN patients.
Evaluation of polypropylene CSF low-bind collection tubes for trace metal contamination
Bitzer, Anna C, Jannetto, Paul J. , Bornhorst, Joshua A. , Bornhorst, Joshua

Laboratory Medicine | August 13, 2024 | Volume: 56 | Issue: 1 | Pages: 64-69

10.1093/labmed/lmae067 Get It

Abstract Background Due to the ability of metal ions to cross the blood–brain barrier, there has been interest in analyzing cerebrospinal fluid (CSF) for trace element concentrations to investigate possible correlations with neurodegenerative diseases. In this study, Sarstedt polypropylene CSF collection tubes were analyzed to determine the contamination levels of aluminum, titanium, chromium, manganese, cobalt, nickel, molybdenum, gadolinium, vanadium, arsenic, cadmium, mercury, lead, thallium, selenium, copper, zinc, and iron. Methods Sarstedt polypropylene CSF collection tubes from 2 separate lots (n = 10 per lot) were filled with a 2 mL aliquot of a CSF pool with known element concentrations. After 24 hours of leaching at room temperature, all 18 elements were analyzed via inductively coupled plasma mass spectrometry (ICP-MS). Results were subtracted from the initial pool concentration to determine contamination levels. Results No detectable contamination above the assay limit of detection was found in 11 analytes. Molybdenum and selenium contamination was measured in all tubes, and aluminum, titanium, manganese, thallium, and zinc had minimal levels of sporadic detectable contamination in 25% or fewer of the tubes tested. Conclusions Sarstedt polypropylene CSF tubes are an acceptable collection tube for the analysis of most assessed metals in CSF.
Optimizing cutpoints for clinical interpretation of brain amyloid status using plasma p‐tau217 immunoassays
Griswold, Michael , Bornhorst, Joshua A. , Graff‐Radford, Jonathan , Lowe, Val J. , Jack, Clifford R. , Petersen, Ronald , Algeciras‐Schimnich, Alicia , Algeciras-Schimnich, Alicia , Figdore, Daniel J. , Jack, Clifford R , Bornhorst, Joshua , Ramanan, Vijay K. , Vemuri, Prashanthi , Knopman, David S.

Alzheimer's & Dementia | July 19, 2024 | Volume: 20 | Issue: 9 | Pages: 6506-6516

10.1002/alz.14140 Get It

Abstract INTRODUCTION We aimed to evaluate clinical interpretation cutpoints for two plasma phosphorylated tau (p‐tau)217 assays (ALZpath and Lumipulse) as predictors of amyloid status for implementation in clinical practice. METHODS Clinical performance of plasma p‐tau217 against amyloid positron emission tomography status was evaluated in participants with mild cognitive impairment or mild dementia ( n = 427). RESULTS Using a one‐cutpoint approach (negative/positive), neither assay achieved ≥ 90% in both sensitivity and specificity. A two‐cutpoint approach yielding 92% sensitivity and 96% specificity provided the desired balance of false positives and false negatives, while categorizing 20% and 39% of results as indeterminate for the Lumipulse and ALZpath assays, respectively. DISCUSSION This study provides a systematic framework for selection of assay‐specific cutpoints for clinical use of plasma p‐tau217 for determination of amyloid status. Our findings suggest that a two‐cutpoint approach may have advantages in optimizing diagnostic accuracy while minimizing potential harm from false positive results. Highlights Phosphorylated tau (p‐tau)217 cutpoints for detection of amyloid pathology were established. A two‐cutpoint approach exhibited the best performance for clinical laboratory use. p‐tau217 assays differed in the percentage of results categorized as intermediate.
Proteomic Identification of Plasma Proteins Associated with Future Dementia Development
Bornhorst, Joshua A. , Bornhorst, Joshua , Algeciras‐Schimnich, Alicia

Clinical Chemistry | May 14, 2024 | Volume: 70 | Issue: 9 | Pages: 1092-1095

10.1093/clinchem/hvae004 Get It