Back to Authors

Bitzer, Anna C

Mayo Clinic

Mayo Clinic

Citations 3

Total Copper and Labile Bound Copper Fraction as a Selective and Sensitive Tool in the Evaluation of Wilson Disease
Bornhorst, Joshua A. , Bitzer, Anna C, Day, Patrick L. , Wermers, Michelle, Smith, Carin Y. , Pazdernik, Vanessa K, Pelto, Ryan, Sankaran, Banu, Quicquaro, Adam Michael , Jannetto, Paul J. , Smith, Carin Y , Day, Patrick , Bornhorst, Joshua , Pazdernik, Vanessa K

The Journal of Applied Laboratory Medicine | September 3, 2024 | Volume: 9 | Issue: 6 | Pages: 1014-1027

10.1093/jalm/jfae090 Get It

Abstract Background A dual filtration-based method for determination of serum labile bound copper (LBC) and LBC fraction (LBC/total copper) was developed. Reduced total copper, elevated LBC, and elevated LBC fraction have been reported in Wilson disease (WD). Methods To evaluate the diagnostic performance of these markers, samples were obtained from 21 WD treatment-naïve (WD-TN, no WD treatment or <28 days of treatment) patients, 46 WD standard-of-care–treated (WD-SOC) patients, along with 246 patients representing other potential disorders of copper status. These were then compared to 213 reference interval population patients. Results Receiver operating characteristic curves for the reference population vs WD-TN yielded areas under the curve for total copper, LBC, and LBC fraction, of 0.99, 0.81, and 0.98, respectively. Using Youden cutoffs, sensitivity/specificity for WD-TN was 95%/97% for total copper, 71%/85% for LBC, and 95%/94% for LBC fraction. LBC values, but not total copper and LBC fraction, differed substantially between WD-TN and WD-SOC cohorts. We propose a dual model wherein total copper and LBC fraction results must agree to be classified as a “positive” or “negative” result for WD. This correctly classified 19/21 WD-TN patients as positive, and 194/213 reference interval patients as negative. The remaining “indeterminate” patients (representing approximately 9% of the reference and the WD-TN populations) exhibited conflicting total copper and LBC fraction results. When indeterminate results are excluded, this model exhibited apparent 100% sensitivity/specificity. Conclusions Agreement of total serum copper and LBC fraction classification may constitute an effective “rule-in” and “rule-out” assessment for WD-TN patients.
Evaluation of polypropylene CSF low-bind collection tubes for trace metal contamination
Bitzer, Anna C, Jannetto, Paul J. , Bornhorst, Joshua A. , Bornhorst, Joshua

Laboratory Medicine | August 13, 2024 | Volume: 56 | Issue: 1 | Pages: 64-69

10.1093/labmed/lmae067 Get It

Abstract Background Due to the ability of metal ions to cross the blood–brain barrier, there has been interest in analyzing cerebrospinal fluid (CSF) for trace element concentrations to investigate possible correlations with neurodegenerative diseases. In this study, Sarstedt polypropylene CSF collection tubes were analyzed to determine the contamination levels of aluminum, titanium, chromium, manganese, cobalt, nickel, molybdenum, gadolinium, vanadium, arsenic, cadmium, mercury, lead, thallium, selenium, copper, zinc, and iron. Methods Sarstedt polypropylene CSF collection tubes from 2 separate lots (n = 10 per lot) were filled with a 2 mL aliquot of a CSF pool with known element concentrations. After 24 hours of leaching at room temperature, all 18 elements were analyzed via inductively coupled plasma mass spectrometry (ICP-MS). Results were subtracted from the initial pool concentration to determine contamination levels. Results No detectable contamination above the assay limit of detection was found in 11 analytes. Molybdenum and selenium contamination was measured in all tubes, and aluminum, titanium, manganese, thallium, and zinc had minimal levels of sporadic detectable contamination in 25% or fewer of the tubes tested. Conclusions Sarstedt polypropylene CSF tubes are an acceptable collection tube for the analysis of most assessed metals in CSF.
Establishment of a Labile Bound Copper Reference Interval in a Healthy Population via an Inductively Coupled Plasma Mass Spectrometry Dual Filtration–Based Assay
Bitzer, Anna C, Fox, Jessica, Day, Patrick L. , Wermers, Michelle, Jannetto, Paul J. , Bornhorst, Joshua A. , Bornhorst, Joshua , Fox, Jessica, Day, Patrick , Pazdernik, Vanessa , Smith, Carin Y.

Archives of Pathology & Laboratory Medicine | October 23, 2023 | Volume: 148 | Issue: 7 | Pages: 818-827

10.5858/arpa.2023-0259-oa Get It

Context.— Clinical testing for Wilson disease (WD) is potentially challenging. Measuring the fraction of labile bound copper (LBC) to total copper may be a promising alternative diagnostic tool with better sensitivity and specificity than some current biomarker approaches. A dual filtration–based inductively coupled mass spectrometry (ICP-MS) assay to measure LBC in serum was developed. Objective.— To establish a reference interval for LBC and LBC to total copper (LBC fraction) in a healthy adult population, and to examine associations between total copper, LBC, and LBC fraction with age, sex, menopausal status, hormone replacement therapy, and supplement use. Design.— Serum samples were collected from healthy male (n = 110) and female (n = 104) patients between the ages of 19 and 80 years. Total copper and LBC were analyzed using ICP-MS. Results were used to calculate the LBC fraction. Reference intervals were calculated for the 2.5th and 97.5th percentiles for both LBC and LBC fraction. Results.— The reference intervals for LBC were determined to be 13 to 105 ng/mL and 12 to 107 ng/mL for female and male patients, respectively. The reference intervals for the LBC fraction were 1.0% to 8.1% and 1.2% to 10.5% for female and male patients, respectively. No significant associations were found regarding age, menopausal status, hormone replacement therapy, or vitamin and supplement use. Conclusions.— Sex-specific reference intervals have now been established for LBC and LBC fraction. These data in conjunction with further testing of WD populations can be used to assess the sensitivity and specificity of LBC fraction in screening, monitoring, and diagnosis.