Objectives The aim of this work was to devise mitigation strategies for addressing a range of image artifacts on a clinical 7 T magnetic resonance imaging scanner using the regulatory-approved single-channel radiofrequency transmit mode and vendor-supplied radiofrequency coils to facilitate clinical scanning within reasonable scan times. Materials and Methods Optimized imaging sequence protocols were developed for routine musculoskeletal knee and neurological imaging. Sources of severe image nonuniformities were identified, and mitigation strategies were devised. A range of custom-made high permittivity dielectric pads were used to compensate for B1 + and B1 − inhomogeneities, and also for magnetic susceptibility-induced signal dropouts particularly in the basal regions of the temporal lobes and in the cerebellum. Results Significant improvements in image uniformity were obtained using dielectric pads in the knee and brain. A combination of small voxels, reduced field of view B0 shimming, and high in-plane parallel imaging factors helped to minimize signal loss in areas of high susceptibility-induced field distortions. The high inherent signal-to-noise ratio at 7 T allowed for high receiver bandwidths and thin slices to minimize chemical shift artifacts. Intermittent artifacts due to radiofrequency inversion pulse limitations (power, bandwidth) were minimized with dielectric pads. A patient with 2 implanted metallic cranial fixation devices located within the radiofrequency transmit field was successfully imaged, with minimal image geometric distortions. Conclusions Challenges relating to severe image artifacts at 7 T using single-channel radiofrequency transmit functionality in the knee and brain were overcome using the approaches described in this article. The resultant high diagnostic image quality paves the way for incorporation of this technology into the routine clinical workflow. Further developmental efforts are required to expand the range of applications to other anatomical areas, and to expand the evidence- and knowledge-base relating to the safety of scanning patients with implanted metallic devices.
Putative mechanisms for spread and transformation of cutaneous T‐cell lymphoma to neurolymphomatosis
The authors present the cases of 3 patients with severe injuries affecting the peroneal nerve combined with loss of tibialis posterior function (inversion) despite preservation of other tibial nerve function. Loss of tibialis posterior function is problematic, since transfer of the tibialis posterior tendon is arguably the best reconstructive option for foot drop, when available. Analysis of preoperative imaging studies correlated with operative findings and showed that the injuries, while predominantly to the common peroneal nerve, also affected the lateral portion of the tibial nerve/division near the sciatic nerve bifurcation. Sunderland’s fascicular topographic maps demonstrate the localization of the fascicular bundle subserving the tibialis posterior to the area that corresponds to the injury. This has clinical significance in predicting injury patterns and potentially for treatment of these injuries. The lateral fibers of the tibial division/nerve may be vulnerable with long stretch injuries. Due to the importance of tibialis posterior function, it may be important to perform internal neurolysis of the tibial division/nerve in order to facilitate nerve action potential testing of these fascicles, ultimately performing split nerve graft repair when nerve action potentials are absent in this important portion of the tibial nerve.
Uniform combined reconstruction of multichannel 7T knee MRI receive coil data without the use of a reference scan
BackgroundMR image intensity nonuniformity is often observed at 7T. Reference scans from the body coil used for uniformity correction at lower field strengths are typically not available at 7T.PurposeTo evaluate the efficacy of a novel algorithm, Uniform Combined Reconstruction (UNICORN), to correct receive coil‐induced nonuniformity in musculoskeletal 7T MRI without the use of a reference scan.Study TypeRetrospective image analysis study.SubjectsMRI data of 20 subjects was retrospectively processed offline.Field Strength/Sequence: Knees of 20 subjects were imaged at 7T with a single‐channel transmit, 28‐channel phased‐array receive knee coil. A turbo‐spin‐echo sequence was used to acquire 33 series of images.AssessmentThree fellowship‐trained musculoskeletal radiologists with cumulative experience of 42 years reviewed the images. The uniformity, contrast, signal‐to‐noise ratio (SNR), and overall image quality were evaluated for images with no postprocessing, images processed with N4 bias field correction algorithm, and the UNICORN algorithm.Statistical TestsIntraclass correlation coefficient (ICC) was used for measuring the interrater reliability. ICC and 95% confidence intervals (CIs) were calculated using the R statistical package employing a two‐way mixed‐effects model based on a mean rating (k = 3) for absolute agreement. The Wilcoxon signed‐rank test with continuity correction was used for analyzing the overall image quality scores.ResultsUNICORN was preferred among the three methods evaluated for uniformity in 97.9% of the pooled ratings, with excellent interrater agreement (ICC of 0.98, CI 0.97–0.99). UNICORN was also rated better than N4 for contrast and equivalent to N4 in SNR with ICCs of 0.80 (CI 0.72–0.86) and 0.67 (CI 0.54–0.77), respectively. The overall image quality scores for UNICORN were significantly higher than N4 (P < 6 × 10‐13), with good to excellent interrater agreement (ICC 0.90, CI 0.86–0.93).Data ConclusionWithout the use of a reference scan, UNICORN provides better image uniformity, contrast, and overall image quality at 7T compared with the N4 bias field‐correction algorithm.Level of Evidence: 4Technical Efficacy: Stage 1J. Magn. Reson. Imaging 2019;50:1534–1544.
Innervation of the anconeus epitrochlearis muscle: MRI and cadaveric studies
ABSTRACT BACKGROUND Management of intraneural perineuriomas remains controversial, largely due to the lack of knowledge regarding the natural history of these lesions. OBJECTIVE To describe the typical radiological growth pattern of intraneural perineuriomas and to determine how the pattern of growth relates to clinical progression. METHODS We performed a retrospective review of the magnetic resonance imaging (MRI) studies and serial clinical examinations of a cohort of patients with biopsy-proven intraneural perineuriomas who had 2 MRI studies at least 2 yr apart. The outcome of interest was radiological growth in length or width of the intraneural perineurioma. Radiological growth was tested for association with clinical progression. RESULTS Twenty patients were included in the study. By width, the lesions were on average larger on repeat imaging ( P = .009). By absolute length, the lesions were on average longer on repeat imaging ( P = .02). By lesion:landmark ratio, there was no difference in length of the lesions between sequential images ( P = .09), with 10 (50%) lesions being shorter and 7 (35%) showing no change. No lesions grew to involve a new nerve or division of a nerve on sequential imaging. None of the variables tested were associated with clinical progression. CONCLUSION We found that intraneural perineuriomas only rarely grow in length, do not grow to involve new nerves or nerve divisions, and growth does not correlate with clinical progression. These findings have significant ramifications for management of these tumors.
Adventitial cysts of the radial artery are joint connected
OBJECTIVEDesmoid-type fibromatosis (DTF) presents a therapeutic dilemma. While lacking metastatic potential, it is a locally aggressive tumor with a strong propensity for occurrence near nerve(s) and recurrence following resection. In this study, the authors introduce the association of an occult neuromuscular choristoma (NMC) identified in patients with DTF.METHODSAfter experiencing a case of DTF found to have an occult NMC, the authors performed a retrospective database review of all other cases of biopsy-proven DTF involving the extremities or limb girdles in patients with available MRI data. Two musculoskeletal radiologists with expertise in peripheral nerve imaging reviewed the MRI studies of the eligible cases for evidence of previously unrecognized NMC.RESULTSThe initial case of a patient with an occult sciatic NMC is described. The database review yielded 40 patients with DTF—18 (45%) in the upper limb and 22 (55%) in the lower limb. Two cases (5%) had MRI findings of NMC associated with the DTF, one in the proximal sciatic nerve and the other in the proximal tibial and sural nerves.CONCLUSIONSThe coexistence of NMC may be under-recognized in a subset of patients with extremity DTF. This finding poses implications for DTF treatment and the likelihood of recurrence after resection or biopsy. Further study may reveal crucial links between the pathogenesis of NMC and DTF and offer novel therapeutic strategies.