Abstract Objectives The aim of this literature review was to establish consensus with respect to the anatomic features of the articular branches innervating the hip joint and the distribution of sensory receptors within its capsule. Methods Five electronic databases were queried, with the search encompassing articles published between January 1945 and June 2019. Twenty-one original articles providing a detailed description of sensory receptors around the hip joint capsule (n=13) and its articular branches (n=8) were reviewed. Results The superior portions of the anterior capsule and the labrum were found to be the area of densest nociceptive innervation. Similar to the distribution of nociceptors, mechanoreceptor density was found to be higher anteriorly than posteriorly. Hip joint capsular innervation was found to consistently involve the femoral and obturator nerves, which supply the anterior capsule, and the nerve to the quadratus femoris, which supplies the posterior capsule. The femoral, obturator, and superior gluteal nerves supply articular branches to the most nociceptor-rich region of the hip capsule. Conclusions The femoral and obturator nerves and the nerve to the quadratus femoris were found to consistently supply articular branches to both the anterior and posterior capsule of the hip joint. The anterior capsule, primarily supplied by the femoral and obturator nerves, and the superior labrum appear to be the primary pain generators of the hip joint, given their higher density of nociceptors and mechanoreceptors. Level of Evidence Anatomy study, literature review.
Background: Suprascapular nerve (SSN) block using bone reference points (BARO) is a technique that in principle is accessible to practitioners without experience in locoregional anesthesia or ultrasound guidance. The primary objective was to validate the feasibility of SSN BARO by an orthopedic surgeon. The secondary objective was to provide a description of the path of the sensory branches from the SSN to the shoulder. Methods: A BARO was performed on 15 cadaveric shoulders by an intern in orthopedic surgery. Ten ml of methylene blue and 0.75% ropivocaine were injected around the SSN. 2.5ml of a red latex solution were also injected to identify the injection site. The distribution of the sensory branches of the NSS was also described. Results: The average distance between the SSN and the injection site was 1.5cm (0-4.5cm). The most frequent injection site was the proximal third of the scapular neck. Fifteen SSNs were marked upstream of the origin of the sensory branches. The 15 SSN produced 3 sensory branches that innervate the posterior glenohumeral capsule, the subacromial bursa, and the coracoclavicular and acromioclavicular ligaments. Conclusion: SSN BARO by an orthopedic surgeon is a simple, reliable, and accurate technique. Injection near the suprascapular notch is recommended to mark the SSN upstream of its three sensory branches.
Sensory innervation of the human elbow joint and surgical considerations
Abstract Based on the currently available literature, total denervation of the elbow joint is considered impossible. However, consensus with respect to the anatomic location of sensory branches is lacking. The aim of this literature review was to establish consensus with respect to the anatomic features of the articular branches innervating the elbow joint, as well as the distribution of sensory receptors about its capsule. Four electronic databases were queried, between January 1945 and June 2019. Twenty‐one original articles providing a detailed description of the distribution of sensory receptors about the elbow joint capsule (5) and its articular branches (16) were reviewed. The posterior capsule was found to be primarily innervated by the ulnar and radial nerves via combined articular branches and sensory branches of the medial antebrachial cutaneous nerve. The anterior capsule was found to be primarily innervated by a plexus of articular ramifications from muscular branches of mixed nerves (ulnar, musculocutaneous, radial, and median nerves). A higher density of nociceptors and mechano‐receptors was identified within the posterior and anterior capsules, respectively. Thorough denervation, via the technique proposed herein, is likely to be sufficient in eliminating pain from degenerative conditions of the elbow joint.
Evolution of Hip Dysplasia in Pediatric Patients With Prader-Willi Syndrome Treated With Growth Hormone Early in Development
Background: Prader-Willi syndrome (PWS) is a rare genetic disorder characterized by obesity, hypotonia, feeding difficulties, obesity, musculoskeletal manifestations including scoliosis, and hip dysplasia (HD). The aim of this study was to characterize the clinical and radiographic evolution of HD in the pediatric PWS population. Methods: The authors performed a retrospective cohort study of 72 patients (147 anteroposterior pelvic radiographs) between January 2004 and December 2016. Center-edge angle (CEA) of Wiberg, acetabular index (AI), and neck-shaft angle (NSA) were measures in all hips. The relationship between radiographic and demographic parameters of age, sex, and body mass index z-score (BMIzs) were assessed. Results: A total of 274 radiographic measurements were performed and analyzed in 72 patients. The mean CEA, AI, and NSA were 21.8±7.1 degrees (range, 5 to 35 degrees), 16.7±7 degrees (range, 5 to 45 degrees), and 142±8.5 degrees (range, 128 to 165 degrees), respectively. HD was diagnosed in 79 (29%) hip radiographs and varied significantly between the age groups (P<0.01). A statistically significant association was identified between age and CEA [β coef, 0.80; 95% confidence interval (CI), 0.6-1; P<0.01], AI (β coef, −0.90; 95% CI, −1.1 to −0.7; P<0.01), and NSA (β coef, −1.11; 95% CI, −1.4 to −0.9; P<0.01) angles. Sex and BMIzs were not identified as independent predictors of radiographic hip angles (P>0.1). Conclusions: The present study demonstrated favorable evolution of hip radiographic parameters in the PWS population treated with growth hormone early in development. This finding should prompt orthopedists to consider observation alone in the management algorithm for HD in patients with PWS. Levels of Evidence: Level III—a retrospective comparative study.
Ultrasound‐Guided Versus Landmark‐Based Approach to the Distal Suprascapular Nerve Block: A Comparative Cadaveric Study
Purpose To compare the accuracy of distal suprascapular nerve (dSSN) blockade performed with the use of ultrasound‐guided regional anesthesia (USRA) versus with a landmark‐based approach (LBA). A secondary aim was to describe the anatomic features of the sensory branches of the dSSN. Methods USRA and LBA were performed in 15 shoulders each from 15 cadavers (total of 30 shoulders). Then, 10 mL of methylene blue‒infused ropivacaine 0.75% was injected into the dSSN. Simultaneously, 2.5 mL of red latex solution was injected to identify the position of the needle tip. The division and distribution of the sensory branches originating from the SSN were described. Results The tip of the needle was identified at 1.3 cm (range, 0‐5.2 cm) and 1.5 cm (range, 0‐4.5 cm) with USRA and the LBA, respectively ( P = .90). Staining diffused past the origin of the most proximal sensory branch in 27 cases. The most proximal sensory branch arose 2.5 cm from the suprascapular notch. Among the 3 failures that occurred in the USRA group, the sensory branches also failed to be marked. All 30 dSSNs gave off 3 sensory branches, which innervated the posterior glenohumeral capsule, the subacromial bursa, and the coracoclavicular and acromioclavicular ligaments. Conclusions An LBA is as reliable and accurate as US guidance for anesthetic blockade of the dSSN. Marking of the suprascapular nerve must be proximal to the suprascapular notch to involve the 3 sensory branches in the anesthetic blockade. Clinical Relevance The present study demonstrates that a landmark‐based approach to anesthetic blockade of the distal suprascapular nerve is accurate and can be performed by orthopaedic surgeons lacking experience in ultrasound‐guided anesthetic techniques.
Ultrasound-Guided Proximal and Distal Suprascapular Nerve Blocks: A Comparative Cadaveric Study
Abstract Objectives The primary aim of our study was to evaluate and compare the accuracy of ultrasound (US)-guided distal suprascapular nerve (dSSN) and proximal SSN (pSSN) blocks. Secondary aims were to compare the phrenic nerve involvement between groups and to describe the anatomical features of the sensory branches of the dSSN. Methods pSSN and dSSN blocks were performed in 14 cadavers (28 shoulders). Ten mL of 0.2% ropivacaine colored with methylene blue was injected under US guidance. Accuracy was determined using SSN staining and the distance between predefined anatomical landmarks and the targeted SSN. The phrenic nerve (PN) was judged to be colored or not. The distribution of the sensory branches that originate from the 14 dSSNs is described. Quantitative data are expressed as median (range). Results The pSSN was dyed more frequently than the dSSN (13 vs 11, P = 0.59). The targeted SSN was close to the suprascapular notch (1.3 [0–5.2] cm) and the origin of the SSN (1.4 [0.2–4.5] cm) for dSSN and pSSN blocks, respectively (P = 0.62). For dSSN blocks, the most frequent injection site was the supraspinous fossa. Three PNs were marked in pSSN blocks, compared with none in dSSN blocks (P = 0.22). Three sensory branches were identified for all 14 dSSNs: the medial subacromial branch, the lateral subacromial branch, and the posterior glenohumeral branch. Conclusions US-guided pSSN and dSSN blocks can be realized with accuracy. A distal approach to the SSN could be an alternative to interscalene brachial plexus block for the management of postoperative pain after shoulder surgery in high–respiratory risk patients.
Midterm outcomes of 146 EVOLVE Proline modular radial head prostheses: a systematic review
Introduction The EVOLVE implant (Wright Medical Technology, Arlington, TN, USA) is a modular loose-fitting radial head prosthesis. The primary objective was to synthesize all available literature investigating the midterm clinical outcomes of the EVOLVE implant. Materials and methods An electronic literature search in Pubmed/Medline, Scopus, EMBASE, and Cochrane library was performed querying for studies published in 2000–2017. Articles describing clinical and radiographical outcomes as well as reoperation were included. Outcomes of interest included range of motion, Mayo Elbow Performance Score, Disabilities of the Arm Shoulder and Hand, radiographic outcome, and reason for reoperation. Results A total of five articles consisting of 146 patients with EVOLVE implants were included. Mean patient age was 57.4 years (range 22–84), and 43.8% were males (n = 64). Mean follow-up was 4.8 years (range 1–14). Mean Mayo Elbow Performance Score and Disabilities of the Arm Shoulder and Hand score were 87.6 (range 30–100) and 18.9 (range 0–82), respectively. Midterm clinical results were good or excellent (Mayo Elbow Performance Score > 74) in 94 patients. Reoperation was observed in 12 patients, with implant revision required in 2 patients. The primary reason for reoperation was persistent stiffness (n = 9). Conclusion Midterm outcomes of EVOLVE radial head prosthesis are satisfactory, and associated complication rates are low. Loose-fit implant method appears to be a reliable approach to avoid failure of radial head prosthesis by painful loosening.
Recurrent desmoid-type fibromatosis associated with underlying neuromuscular choristoma
OBJECTIVEDesmoid-type fibromatosis (DTF) presents a therapeutic dilemma. While lacking metastatic potential, it is a locally aggressive tumor with a strong propensity for occurrence near nerve(s) and recurrence following resection. In this study, the authors introduce the association of an occult neuromuscular choristoma (NMC) identified in patients with DTF.METHODSAfter experiencing a case of DTF found to have an occult NMC, the authors performed a retrospective database review of all other cases of biopsy-proven DTF involving the extremities or limb girdles in patients with available MRI data. Two musculoskeletal radiologists with expertise in peripheral nerve imaging reviewed the MRI studies of the eligible cases for evidence of previously unrecognized NMC.RESULTSThe initial case of a patient with an occult sciatic NMC is described. The database review yielded 40 patients with DTF—18 (45%) in the upper limb and 22 (55%) in the lower limb. Two cases (5%) had MRI findings of NMC associated with the DTF, one in the proximal sciatic nerve and the other in the proximal tibial and sural nerves.CONCLUSIONSThe coexistence of NMC may be under-recognized in a subset of patients with extremity DTF. This finding poses implications for DTF treatment and the likelihood of recurrence after resection or biopsy. Further study may reveal crucial links between the pathogenesis of NMC and DTF and offer novel therapeutic strategies.
Ultrasound‐guided proximal suprascapular nerve block: A cadaveric study
Aims The pathogenesis of intraneural ganglion cysts is controversial. Recent reports in the literature described medial plantar intraneural ganglion cysts (mIGC) with articular branches to subtalar joints. The aim of the current study was to provide further support for the principles underlying the articular theory, and to explain the successes and failures of treatment of mICGs. Patients and Methods Between 2006 and 2017, five patients with five mICGs were retrospectively reviewed. There were five men with a mean age of 50.2 years (33 to 68) and a mean follow-up of 3.8 years (0.8 to 6). Case history, physical examination, imaging, and intraoperative findings were reviewed. The outcomes of interest were ultrasound and/or MRI features of mICG, as well as the clinical outcomes. Results The five intraneural cysts followed the principles of the unifying articular theory. Connection to the posterior subtalar joint (pSTJ) was identified or suspected in four patients. Re-evaluation of preoperative MRI demonstrated a degenerative pSTJ and denervation changes in the abductor hallucis in all patients. Cyst excision with resection of the articular branch (four), cyst incision and drainage (one), and percutaneous aspiration/steroid injection (two) were performed. Removing the connection to the pSTJ prevented recurrence of mIGC, whereas medial plantar nerves remained cystic and symptomatic when resection of the communicating articular branch was not performed. Conclusion Our findings support a standardized treatment algorithm for mIGC in the presence of degenerative disease at the pSTJ. By understanding the pathoanatomic mechanism for every cyst, we can improve treatment that must address the articular branch to avoid the recurrence of intraneural ganglion cysts, as well as the degenerative pSTJ to avoid extraneural cyst formation or recurrence. Cite this article: Bone Joint J 2018;100-B:183–9.