Aims The aim of this study was to achieve consensus for important topics related to periprosthetic infection (PJI) in orthopaedic oncology, and to identify areas for future research. Methods In January 2024, the Birmingham Orthopaedic Oncology Meeting (BOOM) held in Birmingham, UK, gathered 309 delegates from 53 countries to debate 20 consensus statements on PJI in orthopaedic oncology using a modified Delphi process. Results Of 20 questions and statements on PJI in orthopaedic oncology, none achieved unanimous consensus, 18 achieved strong consensus, one achieved moderate consensus, and one achieved weak consensus. The statements that reached consensus with notable agreement were on the prophylaxis of infection, management of leaking wounds, and surgical strategies for the treatment of PJI. Short-duration antibiotic prophylaxis was deemed as effective as longer courses for lower-risk reconstructions, and aggressive management was recommended for wounds draining beyond five to seven days to prevent deep infection. Furthermore, single-stage, two-stage, and 1.5-stage revision were recognized as valid strategies, with two-stage revision remaining the most reliable. The statements that did not achieve consensus were on the role of debridement, antibiotics, and implant retention and prolonged antibiotic use post-revision. Conclusion The BOOM meeting achieved consensus for important topics on periprosthetic infection in orthopaedic oncology, but highlighted the low quality of the underlying evidence. This study has provided recommendations for the treatment of leaky wounds, duration of postoperative antibiotic prophylaxis, and choice of revision strategy. Cite this article: Bone Joint J 2025;107-B(12):1352–1359.
Identifying consensus and areas for future research in chondrosarcoma
AimsThe Birmingham Orthopaedic Oncology Meeting (BOOM), held in January 2024, convened 309 delegates from 53 countries to discuss and refine 21 consensus statements on the optimal management of chondrosarcoma.MethodsWith representation from Europe (43%; n = 133), North America (17%; n = 53), South America (16%; n = 49), Asia (13%; n = 40), Australasia (5%; n = 16), the Middle East (4%; n = 12), and Africa (2%; n = 6), the combined experience of treating bone sarcomas among attendees totalled approximately 30,000 cases annually, equivalent to 66 years of experience in the UK alone. The meeting’s process began with the formation of a local organizing committee, regional leads, and a scientific committee comprising representatives from 150 specialist units across 47 countries. Supported by major orthopaedic oncology organizations, the meeting used a modified Delphi process to develop consensus statements through online questionnaires, thematic groupings, narrative reviews, and anonymous pre-meeting polling.ResultsStrong (> 80%) consensus was achieved on 19 out of 21 statements, reflecting agreement among delegates. Key areas of consensus included the role of radiology in diagnosis and surveillance, the management of locally recurrent disease, and the treatment of dedifferentiated chondrosarcoma. Notably, there was agreement that routine chemotherapy has no role in chondrosarcoma treatment, and radiological surveillance is safe for intraosseous chondrosarcomas. Despite the overall consensus, areas of controversy remain, particularly regarding the treatment of atypical cartilage tumours and surgical margins. These unresolved issues underscore the need for further research and collaboration within the orthopaedic oncology community.ConclusionBOOM represents the largest global consensus meeting in orthopaedic oncology, providing valuable guidance for clinicians managing chondrosarcoma worldwide. The consensus statements offer a reference for clinical practice, highlight key research priorities, and aim to improve patient outcomes on a global scale.Cite this article: Bone Joint J 2025;107-B(2):246–252.
Analysis of 101 Mechanical Failures in Distal Femur Fractures Treated with 3 Generations of Precontoured Locking Plates
Objectives: To evaluate mechanical treatment failure in a large patient cohort sustaining a distal femur fracture treated with a distal femoral locking plate (DFLP). Design: This retrospective case–control series evaluated mechanical treatment failures of DFLPs. Setting: The study was conducted at 8 Level I trauma centers from 2010 to 2017. Patients and Participants: One hundred one patients sustaining OTA/AO 33-A and C distal femur fractures were treated with DFLPs that experienced mechanical failure. Intervention: The intervention included the treatment of a distal femur fracture with a DFLP, affected by mechanical failure (implant failure by loosening or breakage). Main Outcome Measure: The main outcome measures included injury and DFLP details; modes and timing of failure were studied. Results: One hundred forty-six nonunions were found overall (13.4%) including 101 mechanical failures (9.3%). Failures occurred in different manners, locations, and times depending on the DFLPs. For example, 33 of 101 stainless steel (SS) plates (33%) failed by bending or breaking in the working length, whereas no Ti plates failed here ( P < 0.05). Eleven of 12 failures with titanium-Less Invasive Stabilization System (92%) occurred by lost shaft fixation, mostly by the loosening of unicortical screws (91%). Sixteen of 44 variable –angled–LCP failures (36%) occurred at the distal plate–screw junction, whereas only 5 of 61 other DFLPs (8%) failed this way ( P < 0.05). Distal failures occurred on average at 23.7 weeks compared with others that occurred at 38.4 weeks ( P < 0.05). Variable –angled–LCP distal screw–plate junction failures occurred earlier (mean 21.4 weeks). Conclusion: Nonunion and mechanical failure occurred in 14% and 9% of patients, respectively, in this large series of distal femur fracture treated with a DFLP. The mode, location, presence of a prosthesis, and timing of failure varied depending on the characteristics of DFLP. This information should be used to optimize implant usage and design to prolong the period of stable fixation before potential implant failures occur in patients with a prolonged time to union. Level of Evidence: Economic Level IV. See Instructions for Authors for a complete description of levels of evidence.
Ultrasound-Guided Proximal and Distal Suprascapular Nerve Blocks: A Comparative Cadaveric Study
Abstract Objectives The primary aim of our study was to evaluate and compare the accuracy of ultrasound (US)-guided distal suprascapular nerve (dSSN) and proximal SSN (pSSN) blocks. Secondary aims were to compare the phrenic nerve involvement between groups and to describe the anatomical features of the sensory branches of the dSSN. Methods pSSN and dSSN blocks were performed in 14 cadavers (28 shoulders). Ten mL of 0.2% ropivacaine colored with methylene blue was injected under US guidance. Accuracy was determined using SSN staining and the distance between predefined anatomical landmarks and the targeted SSN. The phrenic nerve (PN) was judged to be colored or not. The distribution of the sensory branches that originate from the 14 dSSNs is described. Quantitative data are expressed as median (range). Results The pSSN was dyed more frequently than the dSSN (13 vs 11, P = 0.59). The targeted SSN was close to the suprascapular notch (1.3 [0–5.2] cm) and the origin of the SSN (1.4 [0.2–4.5] cm) for dSSN and pSSN blocks, respectively (P = 0.62). For dSSN blocks, the most frequent injection site was the supraspinous fossa. Three PNs were marked in pSSN blocks, compared with none in dSSN blocks (P = 0.22). Three sensory branches were identified for all 14 dSSNs: the medial subacromial branch, the lateral subacromial branch, and the posterior glenohumeral branch. Conclusions US-guided pSSN and dSSN blocks can be realized with accuracy. A distal approach to the SSN could be an alternative to interscalene brachial plexus block for the management of postoperative pain after shoulder surgery in high–respiratory risk patients.