Abstract Acute carotid terminus occlusion (CTO) is responsible for up to 5% of acute ischemic strokes secondary to emergent large vessel occlusion (ELVO) and up to 20% of acute internal carotid artery (ICA) occlusions. 1 The term “CTO” has also been used to describe occlusions in the supra-clinoid segment or at the bifurcation of the ICA. Compared to other ELVOs, patients with CTO present with higher stroke severity and larger infarct volume, likely to be a result of disruption of direct Circle of Willis collaterals across the anterior communicating artery (AComA) and posterior communicating artery (PComA). 2,3 Similary, CTO is usually associated with worse prognosis compared to other ELVOs in general. With regard to response to treatment, previous studies have reported significantly lower recanalization rates with intravenous alteplase with CTO compared to M1 segment occlusion. With regard to the safety and efficacy of mechanical thrombectomy, prior reports provide conflicting results with some reporting lower successful recanalization rates with CTO compared to M1 occlusion, and others reporting similar results. In our experience, we have found that successful recanalization of CTO can be achieved with a similar approach to M1 occlusions utilizing a direct aspiration first pass technique (ADAPT). 3,4 Herein, we present a case of CTO for which we performed mechanical thrombectomy using ADAPT. This procedure was an emergent standard of care procedure for which a consent was not required and so not obtained.
Carotid In-Stent Stenosis: Cutting Balloon Angioplasty: 2-Dimensional Operative Video
Abstract In-stent stenosis has a reported prevalence of 14% to 19% at 1-yr follow-up after carotid stenting and is associated with an increased risk of acute ischemic stroke. 1,2 Risk factors include female sex, diabetes, and dyslipidemia. Cutting balloon angioplasty is a safe and effective treatment modality for the treatment of carotid in-stent stenosis, and alternative treatment options include observation with medical management and placement of another stent. 3,4 The authors present the case of a 61-yr-old man with carotid in-stent restenosis and progressive worsening on serial imaging with ultrasound. The patient had a history of carotid stenting for symptomatic stenosis 6 mo prior and was maintained on aspirin and clopidogrel. In light of the progressive worsening, the in-stent stenosis was confirmed on computed tomography (CT) angiogram. The options were discussed with the patient and he consented for treatment with cutting balloon angioplasty. Final angiogram showed improvement of the luminal diameter with a residual stenosis of 15%. The patient tolerated the procedure well and was discharged home on postoperative day 1. Follow-up ultrasound demonstrated moderate improvement in peak systolic velocities, and the plan is to continue observation with a clinical follow-up and repeat carotid Dopplers at 3 mo.
Crossing the Carotid Siphon: Techniques to Facilitate Distal Access in Tortuous Anatomy: 2-Dimensional Operative Video
Abstract As capabilities for endovascular treatment of intracranial vascular pathologies continue to expand, the need for access to the distal internal carotid artery with rigid support catheter systems continues to increase. One of the dominant factors limiting this access is patient anatomy, specifically vessel tortuosity. Increased tortuosity of the carotid siphon is a frequently encountered anatomic variant and may complicate endovascular procedures in adults and children. 1,2 Failed attempts to navigate the carotid siphon with a distal access catheter carry a risk of vessel injury and treatment failure. For this reason, techniques that aid in supporting safe advancement of a distal access catheter across a tortuous carotid siphon are essential. 3,4 In this video, we demonstrate 2 ways in which this may be accomplished. The first technique uses a larger diameter microcatheter, such as the AXS Offset catheter (Stryker, Kalamazoo, Michigan), to increase support for the distal access catheter, while the second uses a buddy wire technique to accomplish this increased support. Both of these techniques can help increase the safety of navigating a tortuous carotid siphon and increase the likelihood of successful treatment. The procedures shown were performed with the informed consent of the patients.
Management of Thromboembolic Complications During Aneurysm Coiling: 2-Dimensional Operative Video
Abstract Thromboembolic complications during aneurysm coiling are rare, with higher rates noted in ruptured aneurysms as patients are not usually premedicated with dual antiplatelet therapy. 1,2 Management includes a series of escalating strategies, including medical therapy and intra-arterial thrombolysis. 3-6 Additional strategies include mechanical thrombectomy with suction aspiration and stent retrievers. 3 Intracranial stenting can be used as a last resource, especially in ruptured cases given the need for dual antiplatelets to prevent stent thrombosis. 2 We present the case of a 42-yr-old man with a ruptured left internal carotid artery aneurysm with associated intracranial and intraventricular hemorrhage. The patient was initially presented to an outside facility after he was found in bed unable to speak and with right hemiparesis. The patient consented for surgery and underwent external ventricular drain (EVD) placement for the treatment of obstructive hydrocephalus, followed by diagnostic cerebral angiogram and aneurysm coiling. After the deployment of the last coil, control angiogram showed a small filling defect at the interface between the aneurysm neck and the distal vessel. The patient received intravenous heparin for therapeutic ACT and aspirin load. After progressive enlargement of the thrombus, the patient received intra-arterial glycoprotein (GP) IIB/IIIA inhibitors with a microcatheter positioned proximal to the thrombus. As the thrombus mass continued to enlarge, mechanical thrombectomy with an aspiration catheter was performed twice. Follow-up angiogram 20 min after the second aspiration demonstrated near-complete resolution of the thrombus. The patient recovered from his right hemiparesis, and he was discharged to rehabilitation on POD #21.
Transarterial Embolization of a Transverse Sinus Dural Arteriovenous Fistula: 2-Dimensional Operative Video
Abstract A 40-yr-old male with no significant past medical history presented with sudden onset right-sided retro-orbital headache associated with vision loss after a session of strenuous exercise. Initial assessment with noncontrast head computed tomography at the local emergency department revealed a right sided occipital intracranial hemorrhage (ICH). On arrival the patient ad a left quadrantopsia with Glasgow Coma Scale of 15 and an ICH score of 0. A computed tomographic angiography showed a high density 6 × 9 mm vascular lesion associated with 2 tortuous vessels. Cerebral angiography revealed a right sided dural arteriovenous fistula, Cognard Type IV, with arterial feeders arising from dural branches of the right vertebral artery, the posterior division of the right middle meningeal artery and meningeal branches distal to the neuromeningeal trunk of the left ascending pharyngeal artery. 1 Four days after the ICH event the patient was treated with endovascular Onyx embolization of the fistula, through a transradial approach. Immediate angiographic assessment showed complete obliteration of the dAVF. The patient was discharged home and recovered his visual field deficit over 3 mo. The following operative video includes a discussion of the endovascular technique and treatment nuances associated with the transarterial management of a dural arteriovenous fistula. Patient consent was given prior to the procedure and consent and approval for this operative video was waived due to the retrospective nature of this manuscript and the anonymized video material.
Distal Access to Wide-Necked Aneurysms—‘Around the World’ Technique: 2-Dimensional Operative Video
Abstract Wide-necked aneurysms often pose challenges for distal access to the distal vasculature. This 64-yr-old woman without neurological deficits presented with atypical headaches of gradual onset. MRI revealed a large, symptomatic, unruptured carotid terminus aneurysm incorporating the origin of both the middle (MCA) and anterior cerebral arteries (ACA). Its wide neck created significant risks to coil prolapse and parent vessel compromise, risking stroke. With other options of higher risks, we recommended an around-the-world technique. Standard transfemoral access was used to the right internal carotid artery (ICA) with a 6F-Shuttle sheath and intracranial carotid with a 6F-Sofia distal access catheter. With dual-microcatheter access, 1 catheter was placed in the aneurysm dome, a second in the MCA for stent placement. Advancing the wire around the aneurysm first formed a loop from the lateral to medial wall for access to the MCA. The microcatheter was then advanced around the wire into the MCA, keeping the loop within the dome. With the loop's distal tip anchored, the distal end of the stent was deployed and anchored into the MCA. Both pitfalls (ie, lack of sufficient distal access, collapse of stent device during deployment) were resolved using a balloon catheter. With the balloon positioned and inflated as the anchor, the wire and catheter were pulled together. The loop in the aneurysm's dome straightened out across the neck, the stent was advanced into the MCA, and coiling proceeded. A large neck remnant had partially closed on 6-mo follow-up angiogram. Patient consented to undergo the procedure. Illustrations in video published/printed with permission from Mayfield Clinic.
Letter: An International Investigation Into the COVID-19 Pandemic and Workforce Depletion in Highly Specialized Neurointerventional Units – Insights From Stroke Thrombectomy and Aneurysm Registry and Endovascular Neurosurgery Research Group
Abstract Background Flow diversion is a common endovascular treatment for cerebral aneurysms, but studies comparing different types of flow diverters are scarce. Objective To perform a propensity score matched cohort study comparing the Pipeline Embolization Device (PED) and Flow Redirection Intraluminal Device (FRED) for posterior circulation aneurysms. Methods Consecutive aneurysms of the posterior circulation treated at 25 neurovascular centers with either PED or FRED were collected. Propensity score matching was used to control for age, duration of follow-up imaging, adjunctive coiling, and aneurysm location, size, and morphology; previously ruptured aneurysms were excluded. The two devices were compared for the following outcomes: procedural complications, aneurysm occlusion, and functional outcome. Results A total of 375 aneurysms of the posterior circulation were treated in 369 patients. The PED was used in 285 (77.2%) and FRED in 84 (22.8%) procedures. Aneurysms treated with the PED were more commonly fusiform and larger than those treated with FRED. To account for these important differences, propensity score matching was performed resulting in 33 PED and FRED unruptured aneurysm pairs. No differences were found in occlusion status and neurologic thromboembolic or hemorrhagic complications between the two devices. The proportion of patients with favorable functional outcome was higher with FRED (100% vs 87.9%, p=0.04). Conclusion Comparative analysis of PED and FRED for the treatment of unruptured posterior circulation aneurysms did not identify significant differences in aneurysm occlusion or neurologic complications. Variations in functional outcomes warrant additional investigations.
Early postmarket results with PulseRider for treatment of wide-necked intracranial aneurysms: a multicenter experience
OBJECTIVE Traditionally, stent-assisted coiling and balloon remodeling have been the primary endovascular treatments for wide-necked intracranial aneurysms with complex morphologies. PulseRider is an aneurysm neck reconstruction device that provides parent vessel protection for aneurysm coiling. The objective of this study was to report early postmarket results with the PulseRider device. METHODS This study was a prospective registry of patients treated with PulseRider at 13 American neurointerventional centers following FDA approval of this device. Data collected included clinical presentation, aneurysm characteristics, treatment details, and perioperative events. Follow-up data included degree of aneurysm occlusion and delayed (> 30 days after the procedure) complications. RESULTS A total of 54 aneurysms were treated, with the same number of PulseRider devices, across 13 centers. Fourteen cases were in off-label locations (7 anterior communicating artery, 6 middle cerebral artery, and 1 A 1 segment anterior cerebral artery aneurysms). The average dome/neck ratio was 1.2. Technical success was achieved in 52 cases (96.2%). Major complications included the following: 3 procedure-related posterior cerebral artery strokes, a device-related intraoperative aneurysm rupture, and a delayed device thrombosis. Immediately postoperative Raymond-Roy occlusion classification (RROC) class 1 was achieved in 21 cases (40.3%), class 2 in 15 (28.8%), and class 3 in 16 cases (30.7%). Additional devices were used in 3 aneurysms. For those patients with 3- or 6-month angiographic follow-up (28 patients), 18 aneurysms (64.2%) were RROC class 1 and 8 (28.5%) were RROC class 2. CONCLUSIONS PulseRider is being used in both on- and off-label cases following FDA approval. The clinical and radiographic outcomes are comparable in real-world experience to the outcomes observed in earlier studies. Further experience is needed with the device to determine its role in the neurointerventionalist’s armamentarium, especially with regard to its off-label use.