Abstract 14709: Right Sternal Lead Placement Increases Eligibility for Subcutaneous Defibrillator Implantation in Adults With Congenital Heart Disease
Okamura, Hideo , Bashir, Mohammad U, Webster, Tracy L., Bonnichsen, Crystal R. , Grogan, Martha , Phillips, Sabrina D. , Warnes, Carole A. , Ammash, Naser M., Connolly, Heidi M. , Friedman, Paul A. , McLeod, Christopher J.

Circulation | April 23, 2024 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.14709 Get It

Introduction: The subcutaneous implantable cardioverter defibrillator (S-ICD) is an attractive option for patients with congenital heart disease (CHD) in whom a transvenous system is contraindicated. However, more than 10% of adult patients with CHD fail S-ICD screening due to a large T- to R-wave ratio. We hypothesized right-sternal electrodes may permit S-ICD placement in patients who fail left-sternal screen. Methods: We prospectively screened 40 patients with CHD for S-ICD using the standard proprietary approach. We also screened with right sternal electrodes (with left can electrode position). Results: The mean age of the cohort was 46+/-15 years; 24 males were enrolled. CHD anomalies consisted of tetralogy of Fallot (n=11), Ebstein’s anomaly (n=7), atrial septal defect (n=6), dextro-looped transposition of the great artery (n=5) and other (n=11). Left side screening ECG failed in 9 patients (23%), five of whom passed with right sternal electrodes, increasing the pass rate from 77% to 90%. Figure shows the screening ECG and chest x-ray of a patient who failed in all three vectors on the left side but passed in the alternative vector on the right side and underwent right sided implantation. Conclusions: The addition of right sternal electrodes during screening increases S-ICD eligibility and may avoid thoracotomy for high risk patients with CHD.
Magnetic Resonance Imaging in Nondependent Pacemaker Patients with Pacemakers and Defibrillators with a Nearly Depleted Battery
Okamura, Hideo , Padmanabhan, Deepak , Watson, Robert E. , Dalzell, Connie, Acker, Nancy, Jondal, Mary Lou, ROMME, ABBY L., Cha, Yong‐Mei , Asirvatham, Samuel J. , Felmlee, Joel P. , Friedman, Paul A. , Jondal, Mary, Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | February 7, 2017 | Volume: 40 | Issue: 5 | Pages: 476-481

10.1111/pace.13042 Get It

BackgroundMagnetic resonance imaging (MRI) in patients with non‐MRI‐conditional cardiac implantable electronic devices (CIEDs) has been shown to be safe when performed under closely monitored protocols. However, the safety of MRI in patients with devices with a nearly depleted battery has not been reported.MethodsProspective data were collected between January 2008 and May 2015 in patients with non‐MRI‐conditional CIEDs undergoing clinically indicated MRI under institutional protocol. Patients who were pacemaker dependent were excluded. Patients whose devices were at elective replacement indicator (ERI) at the time of MRI or close to ERI (ERI or replacement for battery depletion within 3 months of scan) were identified through database review and analyzed for clinical events.ResultsMRI scans (n = 569) were performed in 442 patients. Of these, we identified 13 scans performed with a nearly depleted battery in nine patients. All scans with implantable cardioverter defibrillators (ICDs, n = 9) were uneventful. However, two scans with pacemakers close to ERI resulted in a power‐on‐reset (PoR) event. One scan with a pacemaker close to ERI that was programmed to DOO mode reached ERI during MRI and automatically changed to VVI mode. Additionally, one scan with a pacemaker at ERI did not allow programming. All pacemakers with events were implanted before 2005.ConclusionPatients with pacemakers and ICDs with a nearly depleted battery can safely undergo MRI when patients are not pacemaker dependent. Attention should be paid because old devices can result in PoR or ERI during MRI, which may lead to oversensing and inhibition of pacing.
Evaluation of a Unique Defibrillation Unit with Dual‐Vector Biphasic Waveform Capabilities: Towards a Miniaturized Defibrillator
Okamura, Hideo , Killu, Ammar M. , Gilles, Emily J., Tri, Jason , Asirvatham, Roshini, LADEWIG, DEJAE J., Suddendorf, Scott H., Powers, Joanne, Wood‐Wentz, Christina M. , Gray, Peter D., RAYMOND, DOUGLAS M., SAVAGE, SHELLEY J., Savage, Walter T., Asirvatham, Samuel J. , Friedman, Paul A. , Powers, Joanne M, Wood-Wentz, Christina M, Bruce, Charles J. , DeSimone, Christopher V. , GRAY, PETER D., Asirvatham, Samuel J

Pacing and Clinical Electrophysiology | December 19, 2016 | Volume: 40 | Issue: 2 | Pages: 108-114

10.1111/pace.12979 Get It

BackgroundAutomated external defibrillators can provide life‐saving therapies to treat ventricular fibrillation. We developed a prototype unit that can deliver a unique shock waveform produced by four independent capacitors that is delivered through two shock vectors, with the rationale of providing more robust shock pathways during emergent defibrillation. We describe the initial testing and feasibility of this unique defibrillation unit, features of which may enable downsizing of current defibrillator devices.MethodsWe tested our defibrillation unit in four large animal models (two canine and two swine) under general anesthesia. Experimental defibrillation thresholds (DFT) were obtained by delivery of a unique waveform shock pulse via a dual‐vector pathway with four defibrillation pads (placed across the chest). DFTs were measured and compared with those of a commercially available biphasic defibrillator (Zoll M series, Zoll Medical, Chelmsford, MA, USA) tested in two different vectors. Shocks were delivered after 10 seconds of stable ventricular fibrillation and the output characteristics and shock outcome recorded. Each defibrillation series used a step‐down to failure protocol to define the defibrillation threshold.ResultsA total of 96 shocks were delivered during ventricular fibrillation in four large animals. In comparison to the Zoll M series, which delivered a single‐vector, biphasic shock, the energy required for successful defibrillation using the unique dual‐vector biphasic waveform did not differ significantly (P = 0.65).ConclusionsOur early findings support the feasibility of a unique external defibrillation unit using a dual‐vector biphasic waveform approach. This warrants further study to leverage this unique concept and work toward a miniaturized, portable shock delivery system.
Single-Coil Defibrillator Leads Yield Satisfactory Defibrillation Safety Margin in Hypertrophic Cardiomyopathy
Okamura, Hideo , Friedman, Paul A. , Inoue, Yuko , Noda, Takashi , Aiba, Takeshi , Yasuda, Satoshi , Ogawa, Hisao , Kamakura, Shiro, Espinosa, Raúl E. , Aiba, Takeshi , KUSANO, KENGO FUKUSHIMA

Circulation Journal | August 25, 2016 | Volume: 80 | Issue: 10 | Pages: 2199-2203

10.1253/circj.cj-16-0428 Get It

Right Parasternal Lead Placement Increases Eligibility for Subcutaneous Implantable Cardioverter Defibrillator Therapy in Adults With Congenital Heart Disease
Okamura, Hideo , Webster, Tracy L., Bonnichsen, Crystal R. , Grogan, Martha , Phillips, Sabrina D. , Connolly, Heidi M. , Ammash, Naser M., Warnes, Carole A. , Friedman, Paul A. , McLeod, Christopher J. , DeSimone, Christopher V.

Circulation Journal | April 21, 2016 | Volume: 80 | Issue: 6 | Pages: 1328-1335

10.1253/circj.cj-16-0153 Get It