Back to Authors

An, Kai‐Nan

https://orcid.org/0000-0003-4105-9167

Mayo Clinic

Mayo Clinic

Citations 121

THE EFFECT OF FREEZING ON BIOMECHANICAL PROPERTIES OF THE CARPAL TUNNEL SUBSYNOVIAL CONNECTIVE TISSUE
Filius, Anika , Thoreson, Andrew R. , Dharan, Abhishek, Mara, Kristin C. , An, Kai‐Nan , Zhao, Chunfeng , Amadio, Peter C. , Mara, Kristin C

Journal of Musculoskeletal Research | April 7, 2016 | Volume: 18 | Issue: 04 | Pages: 1550019

10.1142/s0218957715500190 Get It

Biomechanical evaluation of the subsynovial connective tissue (SSCT) provides insight into the causes of carpal tunnel syndrome. Studies of carpal tunnel mechanics have been performed using fresh-frozen cadaver tissue. Freezing can affect mechanical properties of some tissues, but its effect on SSCT is unknown. A total of 16 rabbit paws were harvested from eight New Zealand rabbits and subjected to mechanical testing consisting of three repeated tendon excursions in sets of three different excursion magnitudes. One paw from each animal was unfrozen. The contralateral paw was frozen and thawed before testing. Force, energy and stiffness of the first cycle of each set were evaluated, as were ratios of the second to first cycle for each parameter. Two-factor ANOVA with repeated measures over both factors was performed. No significant interactions between factors were found. There were no significant differences between fresh and frozen paws for any parameters, though there were significant differences between excursion amplitudes. The damage threshold was not different between fresh and frozen paws. This study demonstrated that freezing rabbit subsynovial connective tissue does not significantly change its mechanical properties. The same may be true for human cadaver tissues. Results of cadaver mechanical testing may not be influenced by this preservation technique.
Effect of Off-Axis Fluoroscopy Imaging on Two-Dimensional Kinematics in the Lumbar Spine: A Dynamic In Vitro Validation Study
Zhao, Kristin D. , Ben‐Abraham, Ephraim I., Magnuson, Dixon J., Camp, Jon J. , Berglund, Lawrence J., An, Kai‐Nan , Brønfort, Gert , Gay, Ralph E. , Trentadue, Taylor P

Journal of Biomechanical Engineering | March 14, 2016 | Volume: 138 | Issue: 5 | Pages: No page available

10.1115/1.4032995 Get It

Spine intersegmental motion parameters and the resultant regional patterns may be useful for biomechanical classification of low back pain (LBP) as well as assessing the appropriate intervention strategy. Because of its availability and reasonable cost, two-dimensional (2D) fluoroscopy has great potential as a diagnostic and evaluative tool. However, the technique of quantifying intervertebral motion in the lumbar spine must be validated, and the sensitivity assessed. The purpose of this investigation was to (1) compare synchronous fluoroscopic and optoelectronic measures of intervertebral rotations during dynamic flexion–extension movements in vitro and (2) assess the effect of C-arm rotation to simulate off-axis patient alignment on intervertebral kinematics measures. Six cadaveric lumbar–sacrum specimens were dissected, and active marker optoelectronic sensors were rigidly attached to the bodies of L2–S1. Fluoroscopic sequences and optoelectronic kinematic data (0.15-mm linear, 0.17–0.20 deg rotational, accuracy) were obtained simultaneously. After images were obtained in a true sagittal plane, the image receptor was rotated in 5 deg increments (posterior oblique angulations) from 5 deg to 15 deg. Quantitative motion analysis (qma) software was used to determine the intersegmental rotations from the fluoroscopic images. The mean absolute rotation differences between optoelectronic values and dynamic fluoroscopic values were less than 0.5 deg for all the motion segments at each off-axis fluoroscopic rotation and were not significantly different (P > 0.05) for any of the off-axis rotations of the fluoroscope. Small misalignments of the lumbar spine relative to the fluoroscope did not introduce measurement variation in relative segmental rotations greater than that observed when the spine and fluoroscope were perpendicular to each other, suggesting that fluoroscopic measures of relative segmental rotation during flexion–extension are likely robust, even when patient alignment is not perfect.
The Effect of Quantitative Computed Tomography Acquisition Protocols on Bone Mineral Density Estimation
Giambini, Hugo , Dragomir‐Daescu, Dan , Huddleston, P.M. , Camp, Jon J. , An, Kai‐Nan , Nassr, Ahmad , Huddleston, Paul M

Journal of Biomechanical Engineering | September 10, 2015 | Volume: 137 | Issue: 11 | Pages: No page available

10.1115/1.4031572 Get It

Osteoporosis is characterized by bony material loss and decreased bone strength leading to a significant increase in fracture risk. Patient-specific quantitative computed tomography (QCT) finite element (FE) models may be used to predict fracture under physiological loading. Material properties for the FE models used to predict fracture are obtained by converting grayscale values from the CT into volumetric bone mineral density (vBMD) using calibration phantoms. If there are any variations arising from the CT acquisition protocol, vBMD estimation and material property assignment could be affected, thus, affecting fracture risk prediction. We hypothesized that material property assignments may be dependent on scanning and postprocessing settings including voltage, current, and reconstruction kernel, thus potentially having an effect in fracture risk prediction. A rabbit femur and a standard calibration phantom were imaged by QCT using different protocols. Cortical and cancellous regions were segmented, their average Hounsfield unit (HU) values obtained and converted to vBMD. Estimated vBMD for the cortical and cancellous regions were affected by voltage and kernel but not by current. Our study demonstrated that there exists a significant variation in the estimated vBMD values obtained with different scanning acquisitions. In addition, the large noise differences observed utilizing different scanning parameters could have an important negative effect on small subregions containing fewer voxels.
Effects of lubricant and autologous bone marrow stromal cell augmentation on immobilized flexor tendon repairs
Zhao, Chunfeng , Ozasa, Yasuhiro , Shimura, Haruhiko , Reisdorf, Ramona L., Thoreson, Andrew R. , Jay, Gregory D. , Moran, Steven L. , An, Kai‐Nan, Amadio, Peter C. , An, Kai‐Nan

Journal of Orthopaedic Research | July 16, 2015 | Volume: 34 | Issue: 1 | Pages: 154-160

10.1002/jor.22980 Get It

ABSTRACTThe purpose of the study was to test a novel treatment that carbodiimide‐derivatized‐hyaluronic acid‐lubricin (cd‐HA‐lubricin) combined cell‐based therapy in an immobilized flexor tendon repair in a canine model. Seventy‐eight flexor tendons from 39 dogs were transected. One tendon was treated with cd‐HA‐lubricin plus an interpositional graft of 8 × 105 BMSCs and GDF‐5. The other tendon was repaired without treatment. After 21 day of immobilization, 19 dogs were sacrificed; the remaining 20 dogs underwent a 21‐day rehabilitation protocol before euthanasia. The work of flexion, tendon gliding resistance, and adhesion score in treated tendons were significantly less than the untreated tendons (p < 0.05). The failure strength of the untreated tendons was higher than the treated tendons at 21 and 42 days (p < 0.05). However, there is no significant difference in stiffness between two groups at day 42. Histologic analysis of treated tendons showed a smooth surface and viable transplanted cells 42 days after the repair, whereas untreated tendons showed severe adhesion formation around the repair site. The combination of lubricant and cell treatment resulted in significantly improved digit function, reduced adhesion formation. This novel treatment can address the unmet needs of patients who are unable to commence an early mobilization protocol after flexor tendon repair. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 34:154–160, 2016.
Lubricin in human achilles tendon: The evidence of intratendinous sliding motion and shear force in achilles tendon
Sun, Yulong , Wei, Zhuang, Zhao, Chunfeng , Jay, Gregory D. , Amadio, Peter C. , An, Kai‐Nan, Wei, Zhuang, Schmid, Thomas M , An, Kai‐Nan

Journal of Orthopaedic Research | April 11, 2015 | Volume: 33 | Issue: 6 | Pages: 932-937

10.1002/jor.22897 Get It

ABSTRACTAchilles tendon is one of the most commonly injured tendons. Mechanical force is regarded as a major causative factor. However, the biomechanics of Achilles tendon and mechanical mechanism of the injuries are unclear. Lubricin expresses at regions exposed to sliding motion and shear force in a number of tissues. This study investigated the distribution and concentration of lubricin in human Achilles tendons for better understanding the biomechanics of Achilles tendon. Achilles tendons were harvested from nine cadavers. Lubricin was extracted from various locations proximal to the calcaneal insertion and quantified with ELISA. The distribution of lubricin was investigated with immunohistochemistry. Lubricin was mainly identified at the interfaces of tendon fascicles, especially in the mid‐portion of the tendon. The concentration of lubricin in Achilles tendons varied by individual and the distance from its calcaneal insertion. The distal portion of the tendon had a higher concentration of lubricin than the proximal regions of the tendon. This study suggests the presence of intratendinous sliding motion of fascicles and shear force at interfaces of fascicles in human Achilles tendon. Shear force could be an important mechanical factor for the development of Achilles tendinopathy and rupture. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:932–937, 2015.
Analysis of the Constraint Joint Loading in the Thumb During Pipetting
Wu, John Z. , Sinsel, Erik W. , Zhao, Kristin D. , An, Kai‐Nan , Buczek, Frank L., Trentadue, Taylor P

Journal of Biomechanical Engineering | April 3, 2015 | Volume: 137 | Issue: 8 | Pages: No page available

10.1115/1.4030311 Get It

Dynamic loading on articular joints is essential for the evaluation of the risk of the articulation degeneration associated with occupational activities. In the current study, we analyzed the dynamic constraint loading for the thumb during pipetting. The constraint loading is considered as the loading that has to be carried by the connective tissues of the joints (i.e., the cartilage layer and the ligaments) to maintain the kinematic constraints of the system. The joint loadings are solved using a classic free-body approach, using the external loading and muscle forces, which were obtained in an inverse dynamic approach combined with an optimization procedure in anybody. The constraint forces in the thumb joint obtained in the current study are compared with those obtained in the pinch and grasp tests in a previous study (Cooney and Chao, 1977, “Biomechanical Analysis of Static Forces in the Thumb During Hand Function,” J. Bone Joint Surg. Am., 59(1), pp. 27–36). The maximal compression force during pipetting is approximately 83% and 60% greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. The maximal lateral shear force is approximately six times, 32 times, and 90% greater than those obtained in the tip pinch, key pinch, and grasp, respectively. The maximal dorsal shear force during pipetting is approximately 3.2 and 1.4 times greater than those obtained in the tip pinch and key pinch, respectively, while substantially smaller than that obtained during grasping. Our analysis indicated that the thumb joints are subjected to repetitive, intensive loading during pipetting, compared to other daily activities.
Effect of pregnancy on joint contracture in the rat knee
Ohtera, Kozo, Zobitz, M. E., Luo, Zong‐Ping , Morrey, B.F. , Ramin, Kirk D., An, Kai‐Nan , O’Driscoll, Shawn W.

Journal of Applied Physiology | March 3, 2015 | Volume: 92 | Issue: 4 | Pages: 1494-1498

10.1152/japplphysiol.00614.2001 Get It

As there is evidence that ligamentous laxity is affected by the female hormones, we hypothesized that hormonal changes occurring during pregnancy could have a therapeutic role in preventing the development of a joint contracture. Knee joint contractures were created in pregnant and nonpregnant rats. After 2 wk of immobilization, the degree of contracture was measured with structural properties of the medial collateral and anterior cruciate ligaments and the pubic symphysis. Although not statistically significant, there was a general trend toward reduced contracture in pregnant compared with nonpregnant rats. Cutting the posterior capsule significantly decreased contracture for both the pregnant and nonpregnant groups, confirming the contribution of capsular structures to contracture. Ultimate loads of the medial collateral and anterior cruciate ligaments significantly decreased after immobilization compared with control, but there was no significant effect due to pregnancy. Stiffness and ultimate load of the pubic symphysis were not significantly different between pregnant and nonpregnant groups. The trend toward reduced contracture with pregnancy points toward a possible therapeutic role for female hormones in the prevention of postoperative and/or posttraumatic joint contracture.
Biomechanical evaluation of flexor tendon graft with different repair techniques and graft surface modification
Wu, Jingheng , Thoreson, Andrew R. , Reisdorf, Ramona L., An, Kai‐Nan, Moran, Steven L. , Amadio, Peter C. , Zhao, Chunfeng , An, Kai‐Nan

Journal of Orthopaedic Research | February 9, 2015 | Volume: 33 | Issue: 5 | Pages: 731-737

10.1002/jor.22844 Get It

ABSTRACTThe purpose of this study was to investigate the biomechanical properties of modified repair techniques for flexor tendon reconstruction and the effects of surface modification using carbodiimide‐derivatized synovial fluid plus gelatin (cd‐SF‐G), compared to the traditional repair techniques. The second and fifth digits from 16 canine forepaws were randomly divided into 4 groups: (1) traditional graft repairs (TGR group) including distal Bunnell repair and proximal Pulvertaft weave repair; (2) modified graft repairs (MGR group) including distal graft bony attachment repair and proximal step‐cut repair; (3) group TGR coated with cd‐SF‐G (TGR‐C group); and (4) group MGR coated with cd‐SF‐G (MGR‐C group). Digit normalized work of flexion (nWOF), ultimate failure strength, and stiffness were measured. The nWOF in MGR group was significantly less than TGR group (p < 0.05). The nWOF in groups treated with cd‐SF‐G was significantly less than their untreated counterparts (p < 0.05). Ultimate load to failure of the MGR‐C group was significantly greater than the TGR‐C group (p < 0.05), but no significant difference in stiffness was found between these two groups. The modified techniques cannot only improve tendon gliding abilities but can also improve breaking strength. Additionally, surface modification with cd‐SF‐G significantly decreased the work of flexion. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:731–737, 2015.
The effect of tendon excursion velocity on longitudinal median nerve displacement: Differences between carpal tunnel syndrome patients and controls
Filius, Anika , Thoreson, Andrew R. , Passe, Sandra, Zhao, Chunfeng , An, Kai‐Nan, Amadio, Peter C. , Wang, Yuexiang , An, Kai‐Nan

Journal of Orthopaedic Research | January 29, 2015 | Volume: 33 | Issue: 4 | Pages: 483-487

10.1002/jor.22804 Get It

ABSTRACTThe subsynovial connective tissue (SSCT) is a viscoelastic structure connecting the median nerve (MN) and the flexor tendons in the carpal tunnel. Increased strain rates increases stiffness in viscoelastic tissues, and thereby its capacity to transfer shear load. Therefore, tendon excursion velocity may impact the MN displacement. In carpal tunnel syndrome (CTS) the SSCT is fibrotic and may be ruptured, and this may affect MN motion. In this study, ultrasonography was performed on 14 wrists of healthy controls and 25 wrists of CTS patients during controlled finger motions performed at three different velocities. Longitudinal MN and tendon excursion were assessed using a custom speckle tracking algorithm and compared across the three different velocities. CTS patients exhibited significantly less MN motion than controls (p ≤ 0.002). While in general, MN displacement increased with increasing tendon excursion velocity (p ≤ 0.031). These findings are consistent with current knowledge of SSCT mechanics in CTS, in which in some patients the fibrotic SSCT appears to have ruptured from the tendon surface. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:483–487, 2015.
Collagen gel contraction as a measure of fibroblast function in an animal model of subsynovial connective tissue fibrosis
Yang, Tai‐Hua , Thoreson, Andrew R. , Gingery, Anne , Passe, Sandra, An, Kai‐Nan, Zhao, Chunfeng , Amadio, Peter C. , Larson, Dirk R. , An, Kai‐Nan , Gingery, Anne

Journal of Orthopaedic Research | January 28, 2015 | Volume: 33 | Issue: 5 | Pages: 668-674

10.1002/jor.22835 Get It

ABSTRACTCarpal tunnel syndrome (CTS) is a peripheral neuropathy characterized by non‐inflammatory fibrosis of the subsynovial connective tissues (SSCT). A rabbit model of CTS was developed to test the hypothesis that SSCT fibrosis causes the neuropathy. We used a cell‐seeded collagen‐gel contraction model to characterize the fibrosis in this model in terms of cellular mechanics, specifically to compare the ability of SSCT cells from the rabbit model and normal rabbits to contract the gel, and to assess the effect of transforming growth factor‐β1,which is upregulated in CTS, on these cells. SSCT fibrosis was induced in six retired breeder female rabbits which were sacrificed at 6 weeks (N = 3) and 12 weeks (n = 3). An additional two rabbits served as controls. SSCT was harvested according to a standard protocol. Gels seeded with SSCT cells from rabbits sacrificed at 6 weeks had significantly higher tensile strength (p < 0.001) and Young's modulus (p < 0.001) than gels seeded with cells from rabbits sacrificed at 12 weeks or control animals. TGF‐β1 significantly increased the decay time constant (p < 0.001), tensile strength (p < 0.001), and Young's modulus (p < 0.001) regardless of the cell source. This model may be useful in screening therapeutic agents that may block SSCT fibrosis, identifying possible candidates for CTS treatment. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:668–674, 2015.