Back to Authors

Schmid, Thomas M

0000-0003-2745-7273

Mayo Clinic

Rush University

Citations 2

Lubricin in human achilles tendon: The evidence of intratendinous sliding motion and shear force in achilles tendon
Sun, Yulong , Wei, Zhuang, Zhao, Chunfeng , Jay, Gregory D. , Amadio, Peter C. , An, Kai‐Nan, Wei, Zhuang, Schmid, Thomas M , An, Kai‐Nan

Journal of Orthopaedic Research | April 11, 2015 | Volume: 33 | Issue: 6 | Pages: 932-937

10.1002/jor.22897 Get It

ABSTRACTAchilles tendon is one of the most commonly injured tendons. Mechanical force is regarded as a major causative factor. However, the biomechanics of Achilles tendon and mechanical mechanism of the injuries are unclear. Lubricin expresses at regions exposed to sliding motion and shear force in a number of tissues. This study investigated the distribution and concentration of lubricin in human Achilles tendons for better understanding the biomechanics of Achilles tendon. Achilles tendons were harvested from nine cadavers. Lubricin was extracted from various locations proximal to the calcaneal insertion and quantified with ELISA. The distribution of lubricin was investigated with immunohistochemistry. Lubricin was mainly identified at the interfaces of tendon fascicles, especially in the mid‐portion of the tendon. The concentration of lubricin in Achilles tendons varied by individual and the distance from its calcaneal insertion. The distal portion of the tendon had a higher concentration of lubricin than the proximal regions of the tendon. This study suggests the presence of intratendinous sliding motion of fascicles and shear force at interfaces of fascicles in human Achilles tendon. Shear force could be an important mechanical factor for the development of Achilles tendinopathy and rupture. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:932–937, 2015.
Effects of trypsinization and mineralization on intrasynovial tendon allograft healing to bone
Alphen, Nick A. van, Thoreson, Andrew R. , Chen, Qingshan , An, Kai‐Nan, Amadio, Peter C. , Zhao, Chunfeng , Qu, Jin, Qu, Jin , An, Kai‐Nan , Schmid, Thomas M

Journal of Orthopaedic Research | January 21, 2015 | Volume: 33 | Issue: 4 | Pages: 468-474

10.1002/jor.22779 Get It

ABSTRACTThe purpose of the current study was to develop a novel technology to enhance tendon‐to‐bone interface healing by trypsinizing and mineralizing (TM) an intrasynovial tendon allograft in a rabbit bone tunnel model. Eight rabbit flexor digitorum profundus (FDP) tendons were used to optimize the trypsinization process. An additional 24 FDP tendons were stratified into control and TM groups; in each group, 4 tendons were used for in vitro evaluation of TM and 8 were transplanted into proximal tibial bone tunnels in rabbits. The samples were evaluated histologically and with mechanical testing at postoperative week 8. Maximum failure strength and linear stiffness were not significantly different between the control and TM tendons. A thin fibrous band of scar tissue formed at the graft‐to‐bone interface in the control group. However, only the TM group showed obvious new bone formation inside the tendon graft and a visible fibrocartilage layer at the bone tunnel entrance. This study is the first to explore effects of TM on the intrasynovial allograft healing to a bone tunnel. TM showed beneficial effects on chondrogenesis, osteogenesis, and integration of the intrasynovial tendon graft, but mechanical strength was the same as the control tendons in this short‐term in vivo study. © 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 33:468–474, 2015.