Back to Authors

Ollivier, Matthieu

https://orcid.org/0000-0002-6910-0873

Mayo Clinic

Centre National de la Recherche Scientifique

Citations 11

Managing the meniscus Part 2: Traumatic tear patterns, biologic augmentation, transplantation, innovation and future research
Runer, Armin , Kolevar, Matthew P. , Kopf, Sebastian, Krych, Aaron J, Getgood, Alan, Spalding, Tim , Prill, Robert, Tuca, Maria, Ollivier, Matthieu, Siebenlist, Sebastian, Tapasvi, Sachin, Musahl, Volker, Spalding, Tim , Nazzal, Ehab M. , Hughes, Jonathan Daniel , Kopf, Sebastian , Krych, Aaron J. , Hirschmann, Michael T. , LaPrade, Robert F. , Getgood, Alan , Prill, Robert , Tuca, María , Ollivier, Matthieu , Siebenlist, Sebastian , Tapasvi, Sachin Ramchandra , Musahl, Volker

Knee Surgery, Sports Traumatology, Arthroscopy | January 31, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1002/ksa.70314 Get It

Abstract Acute, traumatic meniscus tears are common and should be repaired whenever possible. However, the biological age of the patient, along with the specific tear morphology, may significantly influence the selection of the repair technique, expected clinical outcomes and the postoperative rehabilitation protocol. Risk factors for failure of meniscus repair, such as ligament laxity, need to be addressed to improve the healing potential of the meniscus. Biologic augmentation strategies, including bone marrow stimulation, platelet‐rich plasma, fibrin clot, mesenchymal stem cells or meniscal wrapping, can be used to enhance healing and reduce failure of meniscus repair rates. However, the clinical evidence remains limited and of low quality. As such, the routine use of biologic augmentation in meniscus repair warrants critical evaluation. In patients with post‐meniscectomy syndrome, meniscus allograft transplantation (MAT) may be a viable option to reduce pain and joint degeneration and improve knee function. Meniscus implants provide alternatives to traditional MAT; however, their long‐term efficacy, chondroprotective effects and integration within the knee joint require further research. Meniscus reconstruction using tendon autografts has been described as an alternative treatment option in patients with meniscus loss. Emerging methods, such as gene therapy and repurposed drugs, demonstrate in vitro potential for advancing meniscal repair, although their clinical applications are still in their infancy. Future research is necessary to optimize meniscal repair techniques, enhance clinical efficacy, and ultimately, improve outcomes in patients. Level of Evidence Level V.
Slope‐Reducing Tibial Plateau‐Leveling Osteotomy
Ollivier, Matthieu , Hoffer, Alexander J , Onishi, Shintaro , Brilhault, J. , Frey-Ollivier, Solenne, Godshaw, Brian , Kley, Kristian

Arthroscopy Techniques | September 23, 2024 | Volume: 14 | Issue: 3 | Pages: No page available

10.1016/j.eats.2024.103264 Get It

Abstract Increased posterior tibial slope (PTS) is a risk factor for anterior cruciate ligament (ACL) tear and ACL reconstruction failure. Anterior closing‐wedge osteotomy (ACWO) decreases the PTS and the risk of reinjury after revision ACL reconstruction. ACWO techniques include supratubercular, transtubercular, or infratubercular. However, there are limitations to the amount of slope correction an ACWO can achieve in the context of a massively abnormal slope. If the necessary slope correction is greater than 20°, a supratubercular ACWO cannot achieve the required correction without high risk of brittle fixation, a transtubercular ACWO would introduce increased morbidity of a secondary osteotomy and change the biomechanics of the patellofemoral joint resulting in significant patella alta, and an infratubercular ACWO would require a major anterior tibial metaphysodiaphyseal resection. The tibial plateau leveling osteotomy (TPLO) is an alternative curved osteotomy commonly used in canines that avoids the adverse events associated with a large ACWO. Further benefits of TPLO for massive slope correction include improved maintenance of native soft‐tissue tension, avoidance of major recurvatum, and the ability to control the correct degree. We describe an open technique for a TPLO to decrease the PTS and the risk of recurrent ACL injury. Technique Video video See video under supplementary data.
Choosing the appropriate measure of central tendency: mean, median, or mode?
Khorana, Arjun, Pareek, Ayoosh , Ollivier, Matthieu , Madjarova, Sophia J., Nwachukwu, Benedict U. , Marigi, Erick M. , Kunze, Kyle N. , Karlsson, Jón , Williams, Riley J.

Knee Surgery, Sports Traumatology, Arthroscopy | November 2, 2022 | Volume: 31 | Issue: 1 | Pages: 12-15

10.1007/s00167-022-07204-y Get It

AbstractMean, median, and mode are among the most basic and consistently used measures of central tendency in statistical analysis and are crucial for simplifying data sets to a single value. However, there is a lack of understanding of when to use each metric and how various factors can impact these values. The aim of this article is to clarify some of the confusion related to each measure and explain how to select the appropriate metric for a given data set. The authors present this work as an educational resource, ensuring that these common statistical concepts are better understood throughout the Orthopedic research community.
Factors Affecting the Risk of Aseptic Patellar Complications in Primary TKA Performed with Cemented All-Polyethylene Patellar Resurfacing
Limberg, Afton K. , Tibbo, Meagan E. , Ollivier, Matthieu , Tammachote, Nattapol , Abdel, Matthew P. , Berry, Daniel J. , Abdel, Matthew P , Berry, Daniel J , Limberg, Afton K. , Tibbo, Meagan E. , Ollivier, Matthieu , Tammachote, Nattapol

Journal of Bone and Joint Surgery | December 21, 2021 | Volume: 104 | Issue: 5 | Pages: 451-458

10.2106/jbjs.21.00356 Get It

Background: Patellar complications are a consequential cause of failure of primary total knee arthroplasty (TKA). The purpose of this study was to evaluate the association of demographic and patient factors with the long-term risk of patellar complications as a function of time in a very large cohort of primary TKAs performed with patellar resurfacing. Methods: We identified 27,192 primary TKAs utilizing cemented all-polyethylene patellar components that were performed at a single institution from 1977 through 2015. We evaluated the risk of any aseptic patellar complication and any aseptic patellar reoperation or revision, subanalyzed risks of reoperation or revision for loosening, maltracking/instability, and wear, and evaluated the risk of clinical diagnosis of patellar fracture and clunk/crepitus. The mean age at TKA was 68 years (range, 18 to 99 years); 57% of the patients were female. The mean body mass index (BMI) was 32 kg/m 2 . The primary diagnosis was osteoarthritis in 83%, and 70% of the TKAs were posterior-stabilized. Median follow-up was 7 years (range, 2 to 40 years). Risk factors for each outcome were evaluated with Cox regression models. Results: Nine hundred and seventy-seven knees with all-polyethylene patellae developed patellar complications. Survivorship free from any aseptic patellar complication was 93.3% at 20 years. Twenty-year survivorship free from any aseptic patellar reoperation was 97.3% and free from any aseptic patellar revision was 97.4%. Fifteen-year survivorship for the same end points for procedures performed from 2000 to 2015 was 95.7%, 99.2% and 99.3% respectively, representing substantial improvements compared with implants placed before 2000. Univariate analysis demonstrated that male sex (hazard ratio [HR], 1.4), an age of <65 years (HR, 1.3), and a BMI of ≥30 kg/m 2 (HR, 1.2) were associated with increased risk of patellar complications (all p ≤0.01). Posterior-stabilized designs were associated with fewer patellar reoperations and revisions overall (HR, 0.4 and 0.4; p < 0.001) but higher risk of patellar clunk/crepitus (HR, 14.1; p < 0.001). Conclusions: The 20-year survivorship free from any aseptic patellar complication in this series of cemented all-polyethylene patellae was 93%. Important risk factors for any aseptic patellar complication were male sex, an age of <65 years, a BMI of ≥30 kg/m 2 , and a patella implanted before 2000. Level of Evidence: Prognostic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Antimicrobial properties of antibiotic-loaded implants
Griseti, Quentin, Jacquet, Christophe , Sautet, Pierre, Parratte, Sébastien , Ollivier, Matthieu , Abdel, Matthew P. , Argenson, Jean‐Noël

The Bone & Joint Journal | May 31, 2020 | Volume: 102-B | Issue: 6_Supple_A | Pages: 158-162

10.1302/0301-620x.102b6.bjj-2019-1636.r1 Get It

Aims The aim of this study was to compare the ability of tantalum, 3D porous titanium, antibiotic-loaded bone cement, and smooth titanium alloy to inhibit staphylococci in an in vitro environment, based on the evaluation of the zone of inhibition (ZOI). The hypothesis was that there would be no significant difference in the inhibition of methicillin-sensitive or methicillin-resistant Staphylococcus aureus (MSSA/MRSA) between the two groups. Methods A total of 30 beads made of three different materials (tantalum/3D porous titanium and smooth titanium alloy) were bathed for one hour in a solution of 1 g vancomycin in 20 ml of sterile water for injection (bath concentration: 50 mg/mL). Ten 1 cm3 cylinders of antibiotic-loaded cement were also created by mixing standard surgical cement with 1 g of vancomycin in standardized sterile moulds. The cylinders were then placed on agar plates inoculated with MSSA and MRSA. The ZOIs were measured each day and the cylinders were transferred onto a new inoculated plate. Results For MSSA and MRSA, no inhibitory effect was found in the control group, and antibiotic-loaded smooth titanium alloy beads showed a short inhibitory effect until day 2. For MSSA, both tantalum and 3D porous titanium beads showed significantly larger mean ZOIs than cement beads (all p < 0.01) each day until day 7 for tantalum and until day 3 for 3D porous titanium. After six days, antibiotic-loaded cement had significantly larger mean ZOIs than the 3D porous titanium (p = 0.027), but no significant difference was found with tantalum (p = 0.082). For MRSA, both tantalum and 3D porous titanium beads had significantly larger mean ZOIs than antibiotic-loaded cement each day until day 6 for tantalum (all p < 0.01) and until day 3 for 3D porous titanium (all p < 0.04). Antibiotic-loaded cement had significantly larger mean ZOIs than tantalum and 3D porous titanium from day 7 to 9 (all p < 0.042). Conclusion These results show that porous metal implants can deliver local antibiotics over slightly varying time frames based on in vitro analysis. Cite this article: Bone Joint J 2020;102-B(6 Supple A):158–162.
Antibiotic-loaded tantalum may serve as an antimicrobial delivery agent
Sautet, P., Parratte, Sébastien , Mékidèche, Thibaut, Argenson, J-N., Ollivier, Matthieu , Sautet, P., Abdel, Matthew P. , Flécher, Xavier

The Bone & Joint Journal | June 30, 2019 | Volume: 101-B | Issue: 7 | Pages: 848-851

10.1302/0301-620x.101b7.bjj-2018-1206.r1 Get It

Aims The aims of this study were to compare the mean duration of antibiotic release and the mean zone of inhibition between vancomycin-loaded porous tantalum cylinders and antibiotic-loaded bone cement at intervals, and to evaluate potential intrinsic antimicrobial properties of tantalum in an in vitro medium environment against methicillin-sensitive Staphylococcus aureus (MSSA). Materials and Methods Ten porous tantalum cylinders and ten cylinders of cement were used. The tantalum cylinders were impregnated with vancomycin, which was also added during preparation of the cylinders of cement. The cylinders were then placed on agar plates inoculated with MSSA. The diameter of the inhibition zone was measured each day, and the cylinders were transferred to a new inoculated plate. Inhibition zones were measured with a Vernier caliper and using an automated computed evaluation, and the intra- and interobserver reproducibility were measured. The mean inhibition zones between the two groups were compared with Wilcoxon’s test. Results MSSA was inhibited for 12 days by the tantalum cylinders and for nine days by the cement cylinders. At day one, the mean zone of inhibition was 28.6 mm for the tantalum and 19.8 mm for the cement group (p < 0.001). At day ten, the mean zone of inhibition was 3.8 mm for the tantalum and 0 mm for the cement group (p < 0.001). The porous tantalum cylinders soaked only with phosphate buffered solution showed no zone of inhibition. Conclusion Compared with cement, tantalum could release antibiotics for longer. Further studies should assess the advantages of using antibiotic-loaded porous tantalum implants at revision arthroplasty. Cite this article: Bone Joint J 2019;101-B:848–851.
Vancomycin elution kinetics from porous tantalum metal
Sautet, Pierre, Mékidèche, Thibaut, Guilhaumou, Romain , Parratte, Sébastien , Ollivier, Matthieu , Abdel, Matthew P. , Argenson, Jean‐Noël

Journal of Orthopaedic Research | October 16, 2018 | Volume: 37 | Issue: 2 | Pages: 308-312

10.1002/jor.24160 Get It

ABSTRACTRevisions TKAs are being completed with uncemented constructs more frequently. We hypothesized that tantalum cones could be an efficient carrier of antibiotics in uncemented procedures. We aimed to compare the release of vancomycin between (i) tantalum and smooth stainless cylinders; (ii) different concentrations of vancomycin; and (iii) different durations of bathing. Specifically designed tantalum cylinders were bathed in a vancomycin solution with various durations of baths. We investigated rinses between each interval as well as the dose of vancomycin. Vancomycin concentrations were determined in each group by fluorescence polarization immunoassay at different intervals (1 h, days 1, 2, 3, 5). At 1 h, the mean vancomycin concentration for the 1‐hour soaking group was 3,172 μg/ml, whereas mean concentration for the smooth stainless steel group was 39.37 μg/ml (p < 0.001). The rinsing group showed a significantly lower concentration at 1 h and 1 day (p < 0.05). The 2‐gram vancomycin group showed no difference at days 1, 2, and 3 compared to the 1‐hour group. The 5, 15, and 30‐minute bathing groups showed significantly lower vancomycin concentrations at all‐time points. All vancomycin concentrations at day 3 were superior to the minimal inhibitory concentration of Staphyloccocus aureus. The mean concentration of vancomycin depends on the material, duration of bathing, the rinsing effect, and the drug dose. Our in‐vitro study is the first to show that porous tantalum cylinders allow antibiotic carriage and progressive release. If appearing in vivo, in a similar extent, this intrinsic property might be useful to prevent and/or treat peri‐prosthetic joint infection. © 2018 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 37:308–312, 2019.
Effect of Postoperative Mechanical Axis Alignment on Survival and Functional Outcomes of Modern Total Knee Arthroplasties with Cement
Abdel, Matthew P. , Ollivier, Matthieu , Parratte, Sébastien , Trousdale, Robert T. , Berry, Daniel J. , Pagnano, Mark W. , Abdel, Matthew P , Berry, Daniel J

Journal of Bone and Joint Surgery | March 21, 2018 | Volume: 100 | Issue: 6 | Pages: 472-478

10.2106/jbjs.16.01587 Get It

Abstract: We previously compared the 15-year survivorship of total knee arthroplasty (TKA) implants that were mechanically aligned (0° ± 3° relative to the mechanical axis) compared with those that were outside that range and considered outliers. The original publication included 398 TKAs (292 in the aligned group and 106 in the outlier group) performed from 1985 to 1990. At the time of follow-up in the previous study, 138 patients (155 TKAs) had died and 59 knees had been revised. Since that publication, 49 additional patients (87 knees) have died. At 20 years, 57 (19.5%) of the 292 knees in the mechanically aligned group had been revised compared with 16 (15.1%) of the 106 knees in the outlier group (p = 0.97). Postoperative alignment within 0° ± 3° of the mechanical axis did not provide a functional advantage at 1, 5, 10, 15, and/or 20 years postoperatively as demonstrated by the Knee Society scores being similar between the groups (p ≥ 0.2 at all intervals). At 20 years, we once again did not find that neutral mechanical alignment provided better implant survivorship than that found in the outlier group. Level of Evidence: Therapeutic Level III . See Instructions for Authors for a complete description of levels of evidence.
Repeat Two-Stage Exchange Arthroplasty for Periprosthetic Knee Infection Is Dependent on Host Grade
Fehring, Keith A. , Ollivier, Matthieu , Mabry, Tad M. , Hanssen, Arlen D. , Abdel, Matthew P.

Journal of Bone and Joint Surgery | January 6, 2017 | Volume: 99 | Issue: 1 | Pages: 19-24

10.2106/jbjs.16.00075 Get It

Background: Two-stage exchange arthroplasty after a previous, failed 2-stage exchange procedure is fraught with difficulties, and there are no clear guidelines for treatment or prognosis given the heterogeneous group of patients in whom this procedure has been performed. The Musculoskeletal Infection Society (MSIS) staging system was developed in an attempt to stratify patients according to infection type, host status, and local soft-tissue status. The purpose of this study was to report the results of 2-stage exchange arthroplasty following a previous, failed 2-stage exchange protocol for periprosthetic knee infection as well as to identify risk factors for failure. Methods: We retrospectively identified 45 patients who had undergone 2 or more 2-stage exchange arthroplasties for periprosthetic knee infection from 2000 to 2013. Patients were stratified according to the MSIS system, and risk factors for failure were analyzed. The minimum follow-up was 2 years (mean, 6 years; range, 24 to 132 months). Results: At the time of follow-up, twenty-two (49%) of the patients had undergone another revision due to infection and 28 (62%) had undergone another revision for any reason. The infection recurred in 6 (75%) of 8 substantially immunocompromised hosts (MSIS type C) and in 3 (30%) of 10 uncompromised hosts (type A) following the second 2-stage exchange arthroplasty (p = 0.06). The infection recurred in 4 (80%) of 5 patients with compromise of the extremity (MSIS type 3) and 3 (33%) of 9 patients with an uncompromised extremity (type 1) (p = 0.27). Both extremely compromised hosts with an extremely compromised extremity (type C3) had recurrence of the infection whereas 3 (30%) of the 10 uncompromised patients with no or less compromise of the extremity (type A1 or A2) did. Five patients in the failure group underwent a third 2-stage exchange arthroplasty following reinfection, and 3 of them were infection-free at the time of the latest follow-up. Conclusions: Uncompromised hosts (MSIS type A) with an acceptable wound (MSIS type 1 or 2) had a 70% rate of success (7 of 10) after a repeat 2-stage exchange arthroplasty, whereas type-B2 hosts had a 50% success rate (10 of 20). The repeat 2-stage exchange procedure failed in both type-C3 hosts; thus, alternative salvage procedures should be considered for such patients. Level of Evidence: Therapeutic Level IV . See Instructions for Authors for a complete description of levels of evidence.
Anatomical Findings in Patients Undergoing Total Hip Arthroplasty for Idiopathic Femoral Head Osteonecrosis
Ollivier, Matthieu , Lunebourg, Alexandre , Parratte, Sébastien , Abdel, Matthew P. , Argenson, Jean‐Noël

Journal of Bone and Joint Surgery | April 20, 2016 | Volume: 98 | Issue: 8 | Pages: 672-676

10.2106/jbjs.14.01099 Get It

Background: Osteonecrosis of the femoral head has a host of etiologies. However, in 30% of the cases, no underlying etiology is identified and the process is considered “idiopathic.” Our hypothesis was that osseous anatomical abnormalities might be frequently found in patients with femoral head osteonecrosis. Methods: A retrospective, 1:2 matched, case-control study was undertaken to compare ninety patients with idiopathic osteonecrosis who had undergone lower-limb computed tomography (CT) prior to undergoing total hip arthroplasty with 180 control patients matched for age, sex, and body mass index (BMI) who had undergone lower-limb computed tomography scanning at our radiology department for any reason except articular or bone disease. Preoperative CT scans were performed for all patients to evaluate femoral offset, femoral neck-shaft angle, femoral neck version, femoral head diameter, acetabular coverage estimated with use of the lateral center-edge angle, acetabular version, and acetabular diameter. The mean age was forty-five years, 69% of the patients were men, and the mean BMI was 26 kg/m 2 . Results: Anatomical “abnormalities” associated with osteonecrosis were determined to be a femoral neck-shaft angle of <129° (likelihood ratio [LR] = 3.6), femoral neck version of >17° (LR = 3.8), a lateral center-edge angle of <32° (LR = 5.7), and acetabular version of <19° (LR = 1.38). A combination of three of the four anatomical “abnormalities” was found in 73% of the patients with osteonecrosis but only 11% of the control cases (LR = 6). Conclusions: This 1:2 matched, anatomical study suggests that acetabular and femoral anatomical factors, in isolation or combination, can be found in a large percentage of cases of “idiopathic” osteonecrosis. Clinical Relevance: In this study, isolated or combined abnormalities of the hip were observed in the group of patients with osteonecrosis. Those elements may help surgeons to understand the process underlying idiopathic osteonecrosis and thus require further investigation.