Background Current thermal ablation methods for atrial fibrillation, including radiofrequency and cryoablation, have a suboptimal success rate. To avoid pulmonary vein (PV) stenosis, ablation is performed outside of the PV, despite the importance of triggers inside the vein. We previously reported on the acute effects of a novel direct current electroporation approach with a balloon catheter to create lesions inside the PVs in addition to the antrum. In this study, we aimed to determine whether the effects created by this nonthermal ablation method were associated with irreversible lesions and whether PV stenosis or other adverse effects occurred after a survival period. Methods and Results Initial and survival studies were performed in 5 canines. At the initial study, the balloon catheter was inflated to contact the antrum and interior of the PV. Direct current energy was delivered between 2 electrodes on the catheter in ECG‐gated 100 μs pulses. A total of 10 PVs were treated demonstrating significant acute local electrogram diminution (mean amplitude decrease of 61.2±19.8%). After the survival period (mean 27 days), computed tomography imaging showed no PV stenosis. On histologic evaluation, transmural, although not circumferential, lesions were seen in each treated vein. No PV stenosis or esophageal injury was present. Conclusions Irreversible, transmural lesions can be created inside the PV without evidence of stenosis after a 27‐day survival period using this balloon‐based direct current ablation approach. These early data show promise for an ablation approach that could directly treat PV triggers in addition to traditional PV antrum ablation.
Percutaneous epicardial pacing using a novel transverse sinus device
AbstractBackgroundTransvenous lead implantation has multiple drawbacks and complications that can be overcome by epicardial lead placement. We aimed to design percutaneously implanted epicardial leads that are anchored through the transverse sinus (TS).Methods and resultsWe designed a novel multielectrode pacing device with four bipole electrode pairs. The device is advanced through the TS, with both ends externalized out of the pericardium. We tested the prototype in one proof‐of‐concept and 5 additional acute canine experiments.The TS device recorded ventricular and atrial electrograms. The median amplitude of near‐field ventricular electrograms was 3.3 mA (IQR 2.0–4.3) and of near‐field atrial electrograms was 2.1 mA (IQR 1.3–2.2). The median ventricular threshold (N = 30) was 1.1 mA (IQR 0.7–3.1) at a median pulse width of 0.5 ms (IQR 0.5–0.5). The median atrial threshold (N = 10) was 2.4 mA (IQR 1.1–7.8) at a median pulse width of 0.5 ms (IQR 0.5–0.9). Right and left ventricular and atrial pacing morphologies were noted while pacing electrodes adjacent to these chambers. Simultaneous left (LV) and right ventricular (RV) pacing showed reduction in QRS duration from 116 ms (RV) and 105 ms (LV) to 91 ms. On necropsy, the device was located in the TS in all animals. There were TS abrasions in one animal, and no other acute complications.ConclusionsThis study highlights a novel approach to epicardial pacing harnessing the unique anatomy of the transverse sinus as an anchoring point. Placement of this novel transverse sinus device was safe and feasible, with acceptable atrial and ventricular thresholds.
Right Ventricular Dysfunction and Long-Term Risk of Sudden Cardiac Death in Patients With and Without Severe Left Ventricular Dysfunction
Background: Right ventricular systolic dysfunction (RVD) often coexists with various cardiopulmonary diseases. However, the association between RVD and risk of sudden cardiac death (SCD) has not been well studied. This study examined the risk of SCD associated with RVD in patients with heterogeneous underlying cardiac diseases. Methods: The Mayo Clinic cardiac care unit database included 5463 consecutive patients with complete echocardiographic evaluation to assess right ventricular systolic function and RVD severity. Prospective surveillance follow-up was obtained for all patients. SCD was adjudicated when a malignant ventricular arrhythmia was documented as the primary rhythm leading to death. RESULTS: The prevalence of mild RVD and moderate-severe RVD was 14.9% and 17.1%, respectively. Patients with RVD were more likely to have a history of congestive heart failure, cardiac arrest, pulmonary disease, and lower baseline left ventricular ejection fraction compared with those with normal right ventricular systolic function. During a median follow-up of 14 months, the incidence of SCD was highest in patients with moderate-severe RVD (7.4% versus 4.4% in mild RVD versus 1.6% in normal right ventricular function; P <0.001). After adjustment for baseline characteristics, mild RVD (adjusted hazard ratio, 1.57; P =0.046) and moderate-severe RVD (adjusted hazard ratio, 1.91; P =0.006) were independently associated with an increased risk of SCD. Moderate-severe RVD remained an independent predictor of SCD for patients with left ventricular ejection fraction >35% without or with preexisting implantable cardioverter-defibrillator (adjusted hazard ratio, 4.12; P =0.003 and adjusted hazard ratio, 5.04; P <0.001, respectively). Conclusions: Presence of RVD in patients with a history of preexisting cardiac disease is an independent predictor of SCD irrespective of left ventricular ejection fraction.
Narrow-Complex Tachycardia in a Woman With a 20-Year History of Supraventricular Tachycardia
Background— People with heart failure and preserved ejection fraction develop increases in left ventricular (LV) end-diastolic pressures during exercise that contribute to dyspnea. In normal open-chest animal preparations, the pericardium restrains LV filling when central blood volume increases. We hypothesized that resection of the pericardium using a minimally invasive epicardial approach would mitigate the increase in LV end-diastolic pressure that develops during volume loading in normal and diseased hearts with the chest intact. Methods and Results— Invasive hemodynamic assessment was performed at baseline and after saline load before and after pericardial resection in normal canines with open (n=3) and closed chest (n=5) and in a pig model with features of human heart failure and preserved ejection fraction with sternum intact (n=4). In closed-chest animals, pericardiotomy was performed using a novel subxiphoid procedure. In both experimental preparations of normal dogs, pericardiotomy blunted the increase in LV end-diastolic pressure with saline infusion, while enhancing the saline-mediated increase in LV end-diastolic volume. With chest intact in the pig model, percutaneous pericardial resection again blunted the increase in LV end-diastolic pressure secondary to volume expansion (+4±3 versus +13±5 mm Hg; P =0.014), while enhancing the saline-mediated increase in LV end-diastolic volume (+17±1 versus +10±2 mL; P =0.016). Conclusions— This proof of concept study demonstrates that pericardial resection through a minimally invasive percutaneous approach mitigates the elevation in LV filling pressures with volume loading in both normal animals and a pig model with diastolic dysfunction. Further study is warranted to determine whether this method is safe and produces similar acute and chronic hemodynamic benefits in people with heart failure and preserved ejection fraction.
Beating Heart Validation of Safety and Efficacy of a Percutaneous Pericardiotomy Tool
Percutaneous Pericardiotomy ToolIntroductionEpicardial procedures frequently require pericardial manipulation. We aimed to develop a nonsurgical percutaneous pericardial modification tool that may (1) facilitate epicardial‐based procedures by enabling adhesiolysis or (2) attenuate the myocardial constraining effect of the pericardium.MethodsThree novel devices were developed to enable pericardiotomy, all of which can be deployed in over‐the‐wire fashion following percutaneous epicardial access. The grasper permits us to seize the pericardial membrane providing leverage for incision. The scissors enables anterograde cutting maneuvers. The reverse‐slitter allows retrograde incisions; in addition, this device has a deflectable tip that increases the potential cutting area. We optimized these tools for safety by including electrodes to test for phrenic nerve stimulation as well as myocardial stimulation to determine directionality of the cutting devices. The base of the scissors and reverse‐slitter are also blunt ensuring that the cutting element is always away from the myocardium.ResultsFollowing 5 nonbeating heart bench test experiments for prototype development, 11 animal (9 canine, 2 swine) studies were performed. Of these 2 were proof‐of‐concept open chest studies; the remaining 9 were entirely closed‐chest, percutaneous procedures allowing for remodification of the prototypes. The tools successfully permitted incision of the pericardium in all studies. Hemodynamic measurements were assessed postincision and showed no compromise of systolic function. No coronary artery or phrenic nerve damage was seen in any study.ConclusionPercutaneous pericardiotomy is feasible and appears to be safe. It may provide leverage in epicardial‐based procedures and offer treatment options in disease processes characterized by pericardial restraint.